HomeMy WebLinkAboutCENTRE FOR ADVANCED TECHNOLOGY PUD NINETEENTH - Filed CS-COMMENT SHEETS - 2003-07-31PROJECT
COMMENT SHEET
City of Fort Collins
Current Planninf
DATE: September 2, 1997 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D. (Steele's)
PLANNER: Ted Shepard
ENGINEER: Michael K. Dean
All comments must be received by: 09/03/97
No Problems
Problems or Concerns (see below or attached)
GENERAL COMMENTS
- Make corrections and additions to General Notes as shown on redlines.
- Submit plans to be reviewed for Drake Rd. improvements with this project. Drake Rd.
Improvements received on 8/28/97 need to be resubmitted for review along with C.A.T. 19
resubmittal.
- Submit plans to be reviewed for Centre Ave. completion with this project.
- Include plat as part of utility plans.
- Coordinate any changes with site and landscape plans.
PLAT
- Worthington Circle Cul-de-Sac R.O.W. needs a 50.5' Radius not 49' as platted.
- Two areas on the plat are labeled as Lot 1.
- SW corner of plat does not have a radius.
- Show power line easement.
- Dedicate R.O.W. to arterial standards of 115' or to back of sidewalk, along Shields and
Drake whichever is greater. Additional R.O.W. needed for auxiliary lanes and turn island.
UTILITY
- Retaining wall @ NW corner of Drake Rd. and Worthington Ave. Show details of wall and
pipe penetration.
- Area adjacent to retaining wall shown as parking on utility plans is shown as a scored
concrete Market Plaza on the Site and Landscape Plans. If area doubles as parking clarify
on all plans, looking at landscape plans this area does not have sufficient screening from
the intersection of Drake Rd. and Worthington Ave.
- North section of Storm line A is not labeled. Size? Type? Length?
- SE corner of property shows an existing Storm Manhole, need to show existing Storm
lines.
- Show intersection details for Shields/Drake and 1000' beyond project boundaries.
- Modify intersection details for Drake/Davidson Dr.
- Clarify conflicting data concerning the OHP pole locations.
GRADING
- Any grading failing outside the plat boundary will require off -site grading easements.
- Label contour ]lines so one can easily identify elevations.
Date:
3 I99F
Signature:
PLEASE SEND COPIES OF MARKED REVISIONS
EJ V LAT
VITE
TILITY
LANDSCAPE
PROJECT
COMMENT SHEET
City of Fort Collins
Current Planninf
DATE: September 12, 1997 DEPT: Engineering
PROJECT:#53-85AQ C.A.T., 19th Filing - Drake Rd. Improvements
PLANNER:Ted Shepard
ENGINEER: Michael 1C Dean
All comments must be received by: 9/17/97
®No Problems
Problems or Concerns (see below or attached)
GENERAL COY MENTS
- Submitt plans through Planning Departments submittal process.
- Reference Centre for Advanced Technology 19th Filing on title page.
- Provide erosion control plans.
- Show intersection details at all intersections.
- Show typical sections detailing median excavation, topsoil tree wellsand moisture barrier
fabric.
- Show Rt. Turn island ramps possible conflict with existing OHP pole.
- Relocate stormline at median conflicts with sanitary line location and tree planting.
- Additional continents and concerns detailed on redlines.
Date: /5. / 9E F Signature:
PLEASE SEND COPIES OF MARKED REVISIONS: ❑ PLAT
SITE
UTILITY
b LANDSCAPE
s
BZs� firer
a
DATE: November 3, 1997 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D. (Steele's)
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than the staff review meeting:
Wednesday, November 5, 1997
PLAT
Worthington Circle Cul-de-Sac needs a 50.5' Radius not 49' as platted.
UTILITY PLAN
- Drive entrances from public streets cannot exceed 35' in width as per standard D-10.
- Show and label decorative scored concrete locations and boundaries to match what is
shown on the current site plan.
- Show parking; stall locations and dimensions on overall utility plan or on a separate
striping plan.
- Retaining wall @ NW corner of Drake Rd. and Worthington Ave. Show details of wall
and pipe penetration.
- Area adjacent to retaining wall shown as parking on utility plans is shown as a scored
concrete Market Plaza on the Site and Landscape Plans. If area doubles as parking clarify
on all plans.
- SE corner of property shows an existing Storm Manhole, need to show existing Storm
lines entering and exiting the manhole.
- Worthington Circle Cul-de-Sac needs a 50.5' Radius not 49'.
** See redline plans for additional comments **
Date: Signature: XS! /-;14�2'
Please send copies of marked revisions _✓Plat Site
Utility Landscape
City of Fort Collins
REVISION
COMMENT SHEET
DATE: November 3, 1997 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Drake Road Improvements
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than the staff review meeting:
Wednesday, November 5, 1997
GENERAL CQ]V ENTS
- Submit plans through Planning Departments submittal process along with Market
Centre portion.
- Provide erosion control plans.
- Show intersection details at all intersections.
- Show typical sections detailing median excavation, topsoil tree wells and moisture
barrier fabric, and splash block.
- Intersection of Drake and Shields needs to be re -engineered with no right turn
island. This turn island was originally designed in order to avoid relocating the
O.H.P. pole. The City Transportation Staff has determined this pole conflicts with
safe pedestrian movements across the turn island and will be relocated
approximately 20' to the East. With the new position of the pole and increasing
the mast arm length we feel the intersections geometry can accommodate all the
necessary lanes without constructing the right turn lane. ( See the attached sketch
for our ideas and design accordingly.)
** See redline plans for additional comments **
Date: 11 3 9 Signature:
Please send copies of marked revisions Plat _✓Site
Utility ✓Landscape
City of Fort Collins
REVISION
COMMENT SHEET
DATE: February 10, 1998 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D.
Drake Road Improvements
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than the staff review meeting:
Wednesday, February 11, 1998
UTILITY PLAN
- Provide locations for the water taps needed to irrigate the planted medians.
- Revise Cross -Sections at Station 17+00 and Station 22+00.
- Station 38+59.59 to Station 41+84.59 the Glue Down Median is below the existing crown of
Drake Rd.. Look at drainage of this section, what will the flows be at Station 41+84.59 during
the 100 year storm? Will there be any problems with cross drainage at this location?
- Comments or, Redlines from Street Oversizing also should be addressed, make note of the
Median Details provided.
Please return all redlines with the next submittal.
** See redline plans for additional comments **
Date: ,Z Z10 9F3 Signature:
Please send copies of marked revisions ✓Plat Re
✓Utility _ andscape x
City of Fort Collins
REVISION
COMMENT SHEET
DATE: February 10, 1998 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D. (Steele's)
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than the staff review meeting:
Wednesday, February 11, 1998
PLAT
Title of Plat should read "A Plat of Centre For Advanced Technology P.U.D. Nineteenth
Filing".
Provide a statement of ownership and maintenance for all tracts.
Worthington .Ave. is shown as an access easement to be vacated by separate document, this street
is already built and should be dedicated as Right of Way over its entire length from Drake Rd. to
Centre Ave.. If the office park portion of C-A.T. 19 is to be separated from this project and
submitted as C.A.T. 21 the remaining portion of Worthington Ave. could be dedicated at that
time.
UTILITY PLAN
- Drive entrances off of Worthington Ave. should align directly across from each other, as
noted on sheet 2/20.
- Provide a horizontal control plan for entire project.
- Provide Request for Variance letters for the driveway widths in excess of 35 feet.
- Provide a separate 8.5"xl 1" sheet with the Worthington Ave./Drake Rd. intersection in order for
the City to design the traffic signal.
** See redline plans for additional comments **
Date: 2 IZ 104178 Signature:
Please send copies of marked revisions ,Plat ,/ Site
ZUtility , andscape
Citv of Fort Collins
rREVISION
COMMENT
DATE: March 6, 1998 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D. (Steele's)
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than:
Friday, March 6, 1998
PLAT
Title of Plat ,should read "A Plat of Centre For Advanced Technology P.U.D. Nineteenth
Filing".
Provide a statement of ownership and maintenance for all tracts.
Worthington Ave. is shown as an access easement to be vacated by separate document, this street
is already buillt and should be dedicated as Right of Way over its entire length from Drake Rd. to
Centre Ave..
UTILITY PLAN
Provide Retaining Wall Details. Retaining Walls 32" in height and over need to be engineered.
The Concrete Encasement Detail and Concrete Collar Detail do not appear to be correct. Use the
Standard Detail for Sewer Joint Encasement Detail and Collar Detail.
** See redline plans for additional comments **
Date: 3Z6/ �� Signature: �•
Please send copies of marked revisions plat _ Site
/Utility _Landscape
City of Fort Collins
x
REVISION
COMMENT
DATE: March 6, 1998 DEPT: Engineering
PROJECT: #53-85AQ C.A.T., 19th Filing, Market Centre P.U.D.
Drake Road Improvements
PLANNER: Ted Shepard
ENGINEER: Michael Dean
All comments must be received no later than:
Friday, March 6, 1998
UTILITY PLAN
Sta. 17+00 on the Drake Road Plan and Profile Sht. 3/12 remove or label line on Plan view.
Revise Cross -Sections at Station 17+00.
Add stations where Glue Down Median drainage break occurs, show on both Plan and Profile
views.
Striping Plan will need to be reviewed by Eric Bracke The City of Fort Collins Traffic Engineer
prior to Mylair submittal. Please provide an additional set of these plans for his review.
Redlines from Street Oversizing will follow and comments should be addressed.
** See redline plans for additional comments **
Date: /"n' 2
_ _ 6 A6 Signature.
Please send copies of marked revisions _Plat _ Site
_ Utility _Landscape
City of Fort Collins