HomeMy WebLinkAboutCHRIST FELLOWSHIP CHURCH LOT 1 3850 ZIEGLER ROAD - Filed CS-COMMENT SHEETS - 2003-07-07City of Fort Collins
Planniina
DATE: ii Dc-�- lgq-s-
PROJECT
COMMENTSHEET
DEPARTMENT:
PROJECT: OA,-,S Fei�o�s�..;� CL,�•�� s���,�,s,�y
PLANNER: 7—,.,,4 s�P���el
All comments must be received by: k�eGo ���-_ aS
No Problems
a —problems or Concerns (see below)
-see ,A bqe-kee-1
Date: Signature:
CHECK IF YOU WISH TO RECEIVE [jam Pb4T
COPIES OF REVISIONS: SITE
❑ LANDSCAPE
(� UTILITY
DEVELOPMENT SERVICES 281 NORTH COLLEGE P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580
PLANNING DEPARTMENT (303)221-6750
REVISION
COMMENT SHEET
DATE:October 6, 2000
DEPT: Engineering
PROJECT: #29-94B, Christ Fellowship Church (LDGS)
All comments must be received no later than the staff review meeting:
Wednesday, October 4, 2000
S1tiv4Talte 8coc� 0..1qoer3
4 .-Need to obtain signaturte of irrigation company or share holders for new ditch/plpe
4! Provide detail of structure/manholes with pipe under street to 18 ADS pipe DE-rq+ic. ou S14E67--7
f� Show cross section of same showing connection as it relates to sidewalk at the
intersection We aId.. ( L pla, sti ( pv le d� to )'#6 aJ rA{c-k/L.
4--Is easement 20 or 22 feet in width? Ir is zL' F eEr. X co,ee Berge v
6—Make changes as requested by water/wastewater, stormwater and engineering and
submit mylars with revised bluelines
Date: 0 16 '400-0 Signature:
Please send copies of marked revisions 'Prat mite
%."lity _1 aedscape
Ift-
City of Fort Collins
STAFF PROJECT REVIEW
Cihof Fart Collins
STEWART & ASSOCIATES Date: 6/27/2003
DICK RUTHERFORD
103 S. MELDRUM
FT. COLLINS, CO 80521
Staff has reviewed your submittal for CHRIST FELLOWSHIP CHURCH PDP - TYPE
II (LUC), and we offer the following comments:
ISSUES:
Department: Engineering Issue Contact: Dave Stringer
Topic: utility plans
t_,Ntlmber: 1 Created: 6/2/2003
Revision to signed set of plans should be numbered as sheet 3A of 13 Cloud the
area's being `c�hanged and use number of revision in a triangle, show in revision
block 0 "-d e- ( ttl 4,4ce -re r 1:� c,, = euG tiv{ p ! TSerf: cy Z e4/c. ',
Number: 2 Created: 6/2/2003
vAdd note : Phase II to be constructed at future date
WE:-4DDE> Nere O,v SHEET 3A P 13
Number: 3 Created: 6/2/2003
Show surface material on 2nd point of acces(southern most) off of Ziegler Road
WE:ABEGEG DZrv5 wAy Ass ArPiJAI-7.
Department: Light & Power Issue Contact: Doug Martine
Topic: Light & Power
Number: 19 Created: 6/9/2003
A landscape plan showing planned streetlights has been sent to
Ted Shepard to be forwarded to the applicant. These planned streetlights must be
shown on the landscape plan, and the street tree locations adjusted to provide 40 ft.
minimum clearance between the trees and each streetlight (15 ft. if the tree is an
ornamental). S will 4.rk t'<a [ a4dre.loc Arc1,;'rc ! ��o.f ;Lc ffr«1L�,a;
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Grading Plan
Number: 37 Created: 6/12/2003
Plan should show how the proposed grading would tie into existing elevations,
currently the plans do not call out or show existing contours on the subject property,
the future phase, or surrounding property. The currently submitted plan is
inAadequate for a complete and thorough review toy � be done. -M add, A he_ pr opv;e_ (
e-'rij cA co•,fv'fr or PhjeZ. &hd kJ,,; `ACI 7n10 JkPo PAaje i B,dt•
L-Topic: Off -site easements
Number: 36 Created: 6/12/2003
Please provide a copy of an existing off -site easement if one was obtained with the
original plan approval. If not then an off -site drainage easement is required.
Page 1
Topic: Utility plans
Number: 35 Created: 6/12/2003
4:1+ease provide revisions to the originally approved plans.
.�._ C. . •t�¢•J „ti .i.•; ....._ .'t_✓�: .. ., G, d( Yc.;.:r'c.. k.: iyM�..'. i �'i!%t '% r%+�y.
,Provide a phasing plan showing what improvements will be done with each Phase.
-r -;' r.,- ,,,If _•a- G'. FnS<.'C +. . :ear ,_ "f: CT :.,
:The currently submitted plans do not show where the drainage qufall is, please,
clarify. a J c := - r.s... 1 .. — .'•J, t w r.: y'p aY ... f'•,1 e ,.
L-Piease provide an erosion control plan for this particular phase of development.
..-
LSince these plans are part of a new PDP, newer regulations such as water quality
requirements are now in effect. Please either provide some water quality treatment
or request a variance. u; -
Provide a drainage and erosion control report addendum discussing drainage,
detention requirements, erosion etc..., and how site requirements are being satisfied
for this first phase submittal.
Department: Traffic Operations Issue Contact: Ward Stanford
Topic: General
Number: 18 Created: 6/4/2003
The TIS for this project was done in 1995. Unfortunately since this development has %tip
not started in so many years, the study needs to be revised to reflect current growth.
Topic: Transportation C7
Number: 33 Created: 6/11/2003
The 1995 TIS needs to be revised to account for current and future area
development. If the project is to be phased, the revision should include discussion
cophefn.ing_.the overall ci ' t' d pCs elements cf-the development.
/
A .. -4 Y-v ;. wrf �'✓.,^:, :� f: ;'ri, l-GYo�iG,,,,. a.r -r=.-c.. `_"c. i:a•-r�ndr aay{.r ^-C-PA4iGi k. ,h
-Vutuber:34 Created:6/11/2003
Only received a grading plan. A plan set indicating all improvements by phase would
be appropriate. 7111 :_ dr ?3-A -u -,kn ,, 1--frt--e—c,s
Department: Transportation Planning Issue Contact: Tom Reiff
Topic: Transportation
;Number: 22 Created: 6/11 /2003
The proposed handicap parking spaces need to be designed to ADA standards - 96"
minimum stall width and either a 60" or 96" accessible aisle adjacent to the stall
along with an accessible ramp. The wider aisle is for a van accessible stall.
'3
Page 2
Number: 25 Created: 6/11/2003
According to the LCUASS, directional access ramps are required for intersections
with detached walks. Please replace the proposed radial stlye ramps at Ziegler and
Charlie Lane with three directional ramps (see red lines). Please note that there are
new ADA standards for access ramps
t✓L:� h {, �. ��__ Pi-s �-. _ .J(� :L.. :1r.: G:,. FL •.. �. ."f :rC�� .el Yi M�
L,Nu rube r: 26 Created: 6/11/2003
Please include a vicinity map on the site plan.
zNumber: 27 Created: 6/11 /2003
According to section 3.2.2 of the City's LUC, bicycle parking needs to be provided.
Please include enough bike parking for 4 bikes near the building's entrance in a
visible secure location and near an accessible ramp. See red lines for suggested
location. L�06. _ f a`e_J
Number: 28 Created: 6/11/2003
The proposed dr'Iveway approach from Charlie Lane needs to be replaced with the
standard driveway approach for local streets. See drawings 706 (Type 1 for
detached sidewalk) and 1601 in the LCUASS for the correct driveway and sidewalk
design. ,-
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: General
(-Number: 20 Created: 6/11/2003
If this project is to be a revision to the approved utility plans then provide all sheets
of the approved plans which show a revision, bubble the revision and note the
revision. If it is not a revision to the approved plans then provide a complete set of
utility plans (i.e. sanitary sewer profile, type,_details� etc.).
Number: 21 Created: 6/11/2003
The water main in Charlie Lane was installed and according to our records no stubs
were installed for this site. Connections to an existing water main should be made
with wet taps not tees. Correct the notes pertaining to the tees on the fire line and
fire hydrant. _ , •, ;� ,' �.
1�iumber: 23 Created: 6/11/2003
Place the proposed curb stop 1 foot from the rear of the utility easement and the
meter pit no more than 2 feet downstream of the curb stop.
See utility and landscape plan for other comments. f • r' ti » L::.
Department: Water Wastewater Issue Contact: Roger Buffington
Topic: Landscape plan
Number: 31 Created: 6/11/2003
Show the 24-inch water main and the fire hydrant near Ziegler on the landscape
plan. There is currently a conflict between the 24-inch main and the row of trees
47
P3eP 3
along Ziegler as shown. Water Utilities and Forestry have agreed upon the following
adjustments to address this conflict. The trees are to be changed to ornamentals
and are to be located 5 feet west of the sidewalk.
Topic: Utility pans
Number: 29 Created: 6/11 /2003
Show thrust block on the fire line and the curb stop/meter pit on the domestic water
service. < �; fa ,_ r .', l rt., j ' 7 c .. +=/ r,t i
'Number: 30 Created: 6/11 /2003
The sewer service elevation at the sewer main would be more than 0.02 feet (or 0.2
feet) higher than the invert of the sewer. Refer to the sewer service connection
detail. J c>r-1 - :, r<
4-Number: 32 Created: 6/11 /2003
Clarify that the sanitary sewer for the first phase goes to Manhole #5 which is
beyond the line labeled "End Construction". u_-_--`{�-' r� �c �1. �;."• n'` : u, -{
Department: Zoning Issue Contact: Jenny Nuckois
Topic: ZONING
4INt tuber: 4 Created: 6/2/2003
There is nct a separate site plan - if landscape and site are to be combined in one ,
please note as such on the plan �; _6 . _ - t.-' ,• 1 T:�" :.%•_-:.
LNumber: 5 Created: 6/2/2003
Handicap spaces are not the correct size - should be 13 feet wide since they are not
next to a pedrwalk way that is at the same grade as the stall. 3.2.2(K)(5)(a)
A�Iumber: 6 Created: 6/2/2003
Show placement of and label bike rack(s)
Number: 7 Created: 6/2/2003
z_ W is the grass area directly south of the building surrounded by a 3' tall chain link
fence? � l P �s y f� p 1 ., ,o-, f
Number: 8 Created: 6/2/2003
'Why are there 6' privacy fences surrounding little 9 x 14 areas - what are those
areas for? (Directly west of building) } JAC. Uns, N V A C_
'Number: 9 Created: 6/2/2003
Is there going to be a trash enclosure anywhere?
rig<.. ��:4...iwvr 4 ��. 4: N0,4
Number: 10 Created: 6/2/2003
Show handicap ramps at the entrance off of Zeigler
Ova
Page 4
„'Number: 11 Created: 6/2/2003
No foundation plantings are being shown, see section 3
y.g2..1(E)(2)(d)
Z w'6.i . Li. `.1..i.. .�L l:T'`�`�'i�\.:•(fR1'�%.t. �!••YJ1�gfii•
Number: 12 a J)+ Created: 6/2/2003
Need to see building envelope, footprint, dimensions, distances to property lines
Number: 13 dY` Created: 6/2/2003
` Building does not meet build -to line requirements, future building envelope won't
meet buiid-to-lines either.
(sue-. (W:1, 4° to �+t �+..•d1
Number. 14 f ° �tQ' P Created: 6/2/2003
Landscape plan needs to include the landscape assurances clause.
z.!Number: 15 Created: 6/2/2003
Building square footage isn't noted anywhere number of parking spaces isn't noted.
Need to show typical stall dimensions, back-up distance etc. �a+u
rr,
rFG �- r a.
Number: 16 4°' � � ” Created: 6/2/2003 _ I
This is in the neighborhood sign district - if any signage is proposed to be b"n iiie' l
building, its LOCATION needs to be shown on the elevations not the the actual
signage, just the sign locations. rr ` ; Y , •'" , el'` I- ` "
t,f�l�t �:nw..,i,o.�
i-Be-sure and return all of your redlined plans when you re -submit. 'cis-
If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at (970) 221-6750.
Sincerely:
Ted Shepard
Chief Planner
:'a *e 5
Project Comments Sheet
City of Fns Selected Departments
ort Colli
Department: Engineering
Date: June 2, 2003
Project: CHIRIST FELLOWSHIP CHURCH PDP - TYPE II (LUC)
All comments must be received by Ted Shepard in Current Planning, no later than
the staff review meeting:
June 11, 2003
Note - Please identify your redlines for future reference
Issue Contact: Dave Stringer
Topic: utility plans
•Ncrmber: 1 Created: 6/2/2003
Revision to signed set of plans should be numbered as sheet 3A of 13 Cloud the
area's being changed and use number of revision in a triangle, show in revision
block W@ Cloy 1-d tkg"riJio,s 0, ji J10Ae4 pla1S: U✓L "deaf
14,ee+3--A aftA 3-3 1�owi.� thcie/ f,I-c04-e &i/..-
Number: 2 Created: 6/2/2003
Ldd note : Phase II to be constructed at future date we. aLLe-! vote
9i
IN -umber: 3 Created: 6/2/2003
Show surface material on 2nd point of acces(southern most) off of Ziegler Road
Tr6E AcceJJ 17 rivu F=om Z1;`i4e e6e,al !dill beA pU14-,
Signature
Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat _ Site Drainage Report Other_
Utility _ Redline Utility Landscape
Page 1
Project Comments Sheet
Selected Departments,
City, of fort Collins
Department: Engineering
Date: August 4, 2003
Project: C:HRIST FELLOWSHIP CHURCH PDP -TYPE II (LUC)
All comments must be received by Ted Shepard in Current Planning, no later than
the staff review meeting:
August 06, 2003
Mote - Please identify your redlines for future reference
Issue Contact: Dave Stringer
Topic: utility plans
Number: 45 Created: 8/4/2003
No additional Comments
Signature Date
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
Plat Site Drainage Report Other_
Utility Redline Utility Landscape
Page 1
Comment Sheet
Project: Christ fellowship Church Subdivision Date: 10-30-95
Dept: Engineering
Cover Sheet
1. Please provide 2 benchmarks referenced to the Black Bolt Survey.
Plat
1. Please acid the Township, Range, Section number, and Meridian to the title area.
2. Need to dedicate the emergency access road as an emergency access easement.
Overall Utility Plan
1. Please keep the southern barricade completely within the ROW to eliminate offsite
easement needs.
2. Need to dedicate more ROW to keep the sidewalk within the ROW.
3. Need to taper the pavement to match the width of the gravel road and provide a detail
of the transition from pavement to gravel including how water flows will be taken
from the pavement and away from the gravel travel lanes.
4. Is the temporary turn -a -round easement an existing easement, or being dedicated by
the owner. Please provide the easement documentation.
Charlie Lane. Plan & Profile
1. See # 3, Overall Utility Plan.
2. Please provide curve data for all curves.
3. Please provide a street cross-section for Charlie Lane.
Please provide an intersection detail (Charlie Lane/C.R.9), see Ft. Collins Street
Standard Detail "D-19" for reference and requirements.
4. Please provide street centerline bearings.
5. Please indicate the slope of the existing land on each end of the profile views.
6. Please show the intersection curve returns, on the profile views.
7. Elevation of the road needs to be elevated more, to provide adequate grade along the
remaining dirt road section
C.R. 9, Plan & Profile
1. See # 5, Charlie Lane,...
2. Provide stationing references on the plan view.
3. Vertical curve is too short for arterial street requirements.
Grading and Drainage Plan
1. Need to address erosion control method due to transition taper needs.
2. Please show what is going to be done with the concentrated flows leaving the paved
street.
Detail Sheet
1. Please provide details for the private drives, transition area, intersection and Charlie Lane
cross-section.
PROJECT
City of Fort Co COMMENT SHEET
Current Planning
DATE: 25 July 1995
DEPARTMENT:
PROJECT: 29-94113 CHRIST FELLOWSHIP CHURCH - Final S/D
PLANNER: Ted Shepard
All comments must be received by: Friday, 4 August1995
❑ No Problems
'ff Problems or Concerns (see below)
P LAT
• CORNERS ALONG CHARLIE LANE - ARE THESE DEDICATED ROW?
• THE 30 FOOT TRACT OFF OF THE END OF NITE COURT NEEDS TO BE LABELED AS A
TRACT AND DEFINED - EMERGENCY AND PEDESTRIAN ACCESS EASEMENT
Date: I b SignaturT"
CHECK I YOU WISH TO RECEIVE ❑ PLAT
COPIES OF REVISIONS; ❑ SITE
❑ LANDSCAPE
❑ UTILITY
COMMUNITY PLANNING and
ENVIRONMENTAL SERVICES. . . 281 NORTH COLLEGE, P.O.BOX 580 FORT COLLINS, COLORADO 80522-0580 (303)221-6750
CURRENT PLANNING DEPARTMENT
PROJECT
COMMENT SHEET
City of Fort Collins
Current Planning
DATE: 4-115-96 DEPT.: SW W/WW =ENGWG
PROJECT: Christ Fellowship Church Subdivision
PLANNER: Ted Shepard
All comments must be received by:
❑ No P-oblems
Problems or Concerns (see below or attached)
• PLAT
1. Need to tie the site to two section corners.
• UTILITY PLANS
1. Need to do full length design of Charlie Lane and Nite Court, including the cul-de-sac.
2. Check easement labeling along South boundary.
3. Please provide cross -sections of North side of Charlie Lane and East side of Nite Court
plus profile any existing drives using the two streets.
4. Show full profiles of each street with full descriptive data, and grades beyond tie-ins
with existing or new roads, for min. of 150'.
5. Need to provide design for C.R. 9 for 1000' beyond this projects construction limits and
provide "As Built" centerline profile.
6. Revise sidewalk ramps.
7. Gravel driveway can not be used by public or private party in the emergency access
easement.
8. See other comments on the plans.
Date: Y-I&- 94 Signature:
CHECK IF YOU WISH TO RECEIVE PLAT
COPIES OF REVISIONS O�SITE
[3-O' LANDSCAPE
UTILITY 0�
REVISION
COMMENT SHEET
DATE: December 9, 1998 TG: Engineering
PROJECT: #29-94B Christ F; '.lowship Church Final
Subdivision
All comments must be received by Ted Shepard no later than the staff
review meeting:
Wednesday, December 30, 1998
❑ No Comment
0 Problems or Concerns (see below or attached)
UTILITY PLAN COMMENTS:
Update the soils report.
You will need to dedicate an additional 7'/2 feet of ROW along County Road 9 (CR 9).
Charlie Lane is considered a Residential Local street. Please modify the ROW and cross
section to reflect this.
.f Nite Court is considered a Residential Local street. Please modify the ROW and cross
section to reflect this.
Please use the correct Attorney's Certificate.
Use a driveway entrance into the site from CR 9 and Charlie Lane.
Reduce the curb return radii off of CR 9 to 20 feet.
Reduce the vertical curve lengths on Charlie Lane to 90 feet and provide all vertical curve
information.
Continued on the next sheet
Date: Signature:
CHECK ME IF YOU WISH TO RECEIVE COPIES OF REVISIONS
✓ Plat _✓ Site Dm*e Report _
✓ Utility ✓ Redlme Utility 7 landscape
City of Fort Collins
Continued from the previous sheet
Remove the pavement options from the utility plans. Just reference the pavement design
if you need to.
Provide a typical cross section of Nite Court.
Provide a flowline curve table for all craves used in the design. Include the radius, chord
length, arc length, angle. bearing, and tangent length.
Provide spot elevations at the intersection of Nite Court with Charlie Lane.
I'm unclear about what happens to the drainage from Charlie Lane. Please clarify. It
appears that it will be draining onto sofneone's property, which is unacceptable.
You will need to provide a preliminary 1,esign of CR 9 for 1000 feet beyond the
construction limits. Include the interim and ultimate improvements.
Provide cross sections showing the interim and ultimate features every 50 feet.
Show both flowline profiles.
Show all of the curb return profiles in the flow line profiles.
Refer to the utility plans for more specific comments and concerns.
REVISION
COMMENT SHEET
DATE: February 1, 2000 TO: Engineering
PROJECT: #29-94B Christ Fellowship Church
All comrnents must be received by Ted Shepard no later than the
staff review meeting: ,
CC Wednesday, February 16, 2000
No Continent
Problems or Concerns (see below or attached)
"PLEASE IDENTIFY YOUR REDLINES FOR FUTURE REFERENCE"
Ce",� _c'--
Date: Signature: T2
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
?` Plat Site _ Drainage Report _ Other
Utility Redline Uti1Gty � dsW
IMKIAWAII
Citv of Fort Collins
REVISION
COMMENT SHEET
DATE: February 1, 2000 TO: Engineering
PROJECT: #29-94B Christ Fellowship Church
All comments must be received by Ted Shepard no later than the
staff review meeting:
CC Wednesday, February 16, 2000
No Conunent
Problems or Concerns (see below or attached)
*PLEASE IDENTIFY YOUR REDLINES FOR FUTURE REFERENCE"
GuG i4 Lcl s.i P�JG
n� 14V.1.FRir-IrAec.Ntrbcr trxvFlq,rTi,ue, f,rEje-AVDlc.f?B fLgA,1•
Date: Signature: �,QL — �2
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
?� Plat Site _Drainage Report _Other 41"I'
Utility Redline Utility Zjzldscge �1
Citv of Fort Collins
REVISION
COMMENT SHEET
DATE:October 6, 2000
DEPT: Engineering
PROJECT: #29-94B, Christ Fellowship Church (LDGS)
All comments must be received no later than the staff review meeting:
Wednesday, October 4, 2000
1. Need to obtain signaturte of irrigation company or share holders for new ditch/pipe
2. Provide detail of structure/manholes with pipe under street to 18 ADS pipe
3. Show cross section of same showing connection as it relates to sidewalk at the
intersection
4. Is easement 20 or 22 feet in width?
5. Make changes as requested by water/wastewater, stormwater and engineering and
submit mylars with revised bluelines
Date: 6 'yP Signature.
Please send copies of marked revisions 'Plat mite
motility _& aadscape
go