HomeMy WebLinkAboutCOUNCIL - AGENDA ITEM - 04/05/2022 - ITEMS RELATED TO THE ADOPTION OF THE 2021 INTERNATItem # 15 Page 1
AGENDA ITEM SUMMARY
Agenda Item 16
April 5, 2022
CDNS-Building Code Services
STAFF
Marcus Coldiron, Chief Building Official
Kirk Longstein, Project Manager
Aaron Guin, Legal
SUBJECT
Items Related to the Adoption of the 2021 International Building Codes, the Colorado Plumbing Code, and
Local Amendments.
EXECUTIVE SUMMARY
A.Second Reading of Ordinance No. 021, 2022, Amending Chapter 5, Article II, Division 2 of the Code of the
City of Fort Collins for the Purpose of Repealing the 2018 International Building Code and Adopting the
2021 International Building Code, with Amendments.
B.Second Reading of Ordinance No. 022, 2022, Amending Chapter 5, Article II, Division 2 of the Code of the
City of Fort Collins for the Purpose of Repealing the 2018 International Energy Conservation Code and
Adopting the 2021 International Energy Conservation Code, with Amendments.
C.Second Reading of Ordinance No. 023, 2022, Amending Chapter 5, Article II, Division 2 of the Code of the
City of Fort Collins for the Purpose of Repealing the 2018 International Residential Code and Adopting the
2021 International Residential Code, with Amendments.
D.Second Reading of Ordinance No. 024, 2022, Amending Chapter 5, Article II, Division 2 of the Code of the
City of Fort Collins for the Purpose of Repealing the 2018 International Existing Building Code and
Adopting the 2021 International Existing Building Code, with Amendments.
E.Second Reading of Ordinance No. 025, 2022, Amending Chapter 5, Article II, Division 2 of the Co de of the
City of Fort Collins for the Purpose of Repealing the 2018 International Swimming Pool and Spa Code and
Adopting the 2021 International Swimming Pool and Spa Code, with Amendments.
F.Second Reading of Ordinance No. 026, 2022, Amending Chapter 5 , Article II, Division 3 of the Code of the
City of Fort Collins for the Purpose of Repealing the 2006 International Property Maintenance Code and
Adopting the 2021 International Property Maintenance Code, with Amendments.
G.Second Reading of Ordinance No. 027, 2022, Amending Chapter 5, Article IV of the Code of the City of
Fort Collins for the Purpose of Repealing the 2018 International Mechanical Code and Adopting the 2021
International Mechanical Code, with Amendments.
H.Second Reading of Ordinance No. 028, 2022, Amending Chapter 5, Article IV of the Code of the City of
Fort Collins for the Purpose of Repealing the 2018 International Fuel Gas Code and Adopting the 2021
International Fuel Gas Code, with Amendments.
I.Second Reading of Ordinance No. 029, 2022, Amending Chapter 5, Article V, Division 1 of the Code of the
City of Fort Collins for the Purpose of Amending the Colorado Plumbing Code.
These Ordinances, unanimously adopted on First Reading on February 15, adopt the most up-to-date,
comprehensive, and fully integrated body of building codes, collectively referred to as the “2021 I -Codes,”
regulating building construction to safeguard the public health, safety, and general welfare by regulating
structural strength and stability, sanitation, ligh t and ventilation, energy conservation, and property protection
from hazards attributed to the built environment within the City of Fort Collins.
Agenda Item 16
Item # 15 Page 2
The 2021 I-Codes will replace the 2018 editions which were adopted on January 12, 2019. These codes are
reviewed and voted on by code officials and construction industry professionals from across the country and
published every three years under the oversight of the International Code Council (“ICC”). These core 2021 I-
Codes represent the latest construction publications from the ICC.
STAFF RECOMMENDATIONS
Staff recommends adoption of the Ordinances on Second Reading.
BACKGROUND/DISCUSSION
At first reading on February 15, 2022, Council adopted all nine of the above -listed ordinances, including local
amendments. In addition to a number of requests from Councilmembers for follow -up information, feedback
received from Council on February 15 and during the Council work session on March 8, 2022, directed staff to
propose updates to regulations related to electric ve hicle (“EV”) charging infrastructure in Ordinance No. 021,
2022, Amending Chapter 5, Article II, Division 2 of the Code for the Purpose of Repealing the 2018
International Building Code and Adopting the 2021 International Building Code, with Amendments.
During its meeting on February 15, Council requested that staff modify restroom requirements in Section
2902.2 of the proposed 2021 IBC to require that single-user restrooms be designated as gender-neutral while
allowing multi-user restrooms to be either gender-neutral or separate-sex restrooms. This new requirement
would apply to all new builds, renovations, additions, and change of occupancy projects that require a building
permit. This change would result in more gender -neutral restrooms for buildings/projects that need a permit,
since most small and mid-size buildings include single-user restrooms.
Staff’s recommended changes to the 2021 International Building Code (“IBC”) and local amendments in
Ordinance No. 021, 2022, since February 15 include:
•EV charging definitions. Based on stakeholder feedback, staff updated the EV charging definitions to
provide clarity and limit the possibility of future reinterpretation of the Code’s intent. These updates clarify
the physical space requirements within the bui lding’s electrical room for EV-Capable parking spaces and
integrate the existing definition of Electric Vehicle Load Management System (“EVLMS”) to allow more
flexibility within future electrical system design per the National Electric Code. The updated de finitions also
provide choices intended to reduce construction costs and electrical service demand. Although EVLMS is
more clearly defined within the National Electric Code, staff included this definition and integrated EVLMS
within the definitions in Chapter 36 of the IBC so that the Code provides a better cross reference and
eliminates ambiguity to preclude future reinterpretation. These updates are depicted within Section 3604.2
of the IBC in Ordinance No. 021, 2022:
o Add Affordable Housing reference as defined by Sec. 5.1 of the Land Use Code
o Provide reference to the National Electric Code and clarify the physical space requirements in the
electrical room.
o Integrate the definition of EVLMS and allow for more flexibility within future electrical system d esign
per the National Electric Code.
•Alternate options for EV charging infrastructure for affordable housing developments . For Council’s
consideration and final determination at second reading, staff have prepared four options that vary the
percentages of different EV parking space types required as noted below. In Ordinance No. 021, 2022,
these options will be found as different percentages in the row titled “Affordable housing” within Table
3604.5:
o Option 1: 10% EV-Capable (Attachment 1 and reflected in the second reading Ordinance as-
published)
o Option 2: 10% EV-Capable + 10% EV-Ready (Attachment 2)
Agenda Item 16
Item # 15 Page 3
o Option 3: 10% EV-Capable + 10% EV-Ready + One Electric Vehicle Supply Equipment (“EVSE”)
installed (Attachment 3)
o Option 4: 20% EV-Capable + 15% EV-Ready (Attachment 4)
Should Council desire to select one of Options 2-4 (in lieu of Option 1, which is included in the published
second reading Ordinance No. 021, 2022), then Council may consider a motion to amend Table 3604.5 to
read as set forth in Attachments 2, 3, or 4.
Gender-neutral bathrooms. A local amendment requiring all new single-user restrooms be designated as
gender neutral has been made to the restroom requirements in Section 2902.2 of the 2021 IBC.
Highlighted language is shown in numbered paragraph 50 of Ordinance No. 021, 022, presented for
adoption on second reading. If the highlighted language is acceptable to Council, no further amendment of
the Ordinance is required.
Follow-up requested during the Council Meeting on February 15
Incremental Cost
Cost implications associated with adoption of the 2021 I-Codes and local amendments were addressed in the
November 9, 2021, Work Session Item submitted by staff, particularly with regard to impact on construction
costs [11/9/2021 Work Session AIS pp. 5-6, Attachment 2, and Attachment 7 (slides 7, 15-16, 38)], costs to
consumers and utility rate payers [11/9/2021 Work Session AIS Attachment 7 (slides 8, 39)], and impacts on
commercial real estate [11/9/2021 Work Session AIS Attachment 7 (slide 40)].
During Council’s work session on March 8, staff presented cost ranges per parking space and scenarios for
the Oak140 affordable housing project as an example of the proposed EV charging code requirements.
City staff from multiple service areas compiled building scenarios for the cumulative City costs associated with
development and have provided this information to Council under separate cover.
Plumbing Codes for Graywater
Adoption of the proposed I-Codes include the Colorado Plumbing Code, which will enable graywater use with
design and installation standards, following adoption of a graywater ordinance by City Council. A graywater
ordinance has been drafted that is consistent with the direction provided by the Council at its work session on
November 23, 2021. Engagement and communications regarding the draft graywater ordinance currently are
underway and are planned to be completed in June 2022. Upon completion of community engagement, it is
anticipated that an ordinance will be presented to City Council for first reading on August 16, 2022. Other tasks
associated with this project include developing the implementation and permitting process and creating design
guideline documents.
Follow-up requested during Council’s March 8 work session
Utilities capacity fees and transformer upgrades
Electric capacity fees were included in the EV parking space costs presented during the March 8 work session.
Because Utilities retains ownership of distribution transformers, however, the “cost” of an upgrade is t he labor
necessary to swap out the transformer. For a typical three-phase commercial transformer, this cost would be
$1,500.
EV charging infrastructure requirements within the IBC include the review and inspection of the electrical plans
and requirements defined by the National Electric Code. Electrical service capacity is based on Utilities’ review
of requests for electric service for all commercial projects. Over the past several years, as a result of
involvement with the City’s development review process, Utilities staff has confirmed that most applications
requiring new service already can accommodate between one and five additional Level 2 EV charging stations
Agenda Item 16
Item # 15 Page 4
without any changes to existing infrastructure plans. More EV chargers may require that serv ice capacities
increase, however, as noted in the cost estimates per parking space.
EV charging and electricity bills
Configuration of EV charging will determine how Utilities bills customers for EV charging electricity use based
on the applicable rate structure. Utilities does not prescribe how a building owner approaches recouping
electricity costs for EV charging. Options range from simply charging monthly or annual fees for typical EV
charging use, to established EVSE and/or software-based solutions. Utilities is prepared to support commercial
building owners in navigating this rapidly evolving landscape.
EV charging infrastructure and financial support for affordable housing projects
During the March 8 work session, Councilmembers suggested that staff add a fourth option for affordable
housing projects to include 20% EV-Capable + 15% EV-Ready. Additionally, Councilmembers expressed
interest in how greater requirements for EV charging infrastructure could be paired with financial support to
offset increased costs. Through the development review process, staff have identified an additional six
affordable housing projects with an additional 237 units that likely will be ready for building permits before the
end of 2022. Using the same assumptions from the March 8 work session, staff estimate the marginal cost of
increasing the EV charging infrastructure requirements under the new Option 4 would be an additional
$150,000-200,000 across all six projects.
The recommended Code package, including local amendments, aligns with Citywide policies including the City
Plan, Our Climate Future plan, the Housing Strategic Plan, and the Water Efficiency Plan:
•City Plan (2019) includes a focus on promoting sustainable development practices and policies that seek
to reduce net energy and water use in new and existing development.
•Our Climate Future (2021) plan includes Big and Next Moves spanning energy, housing, and resilience
(Efficient, Emissions Free Buildings; 100% Renewable Electricity; Healthy Affordable H ousing). This plan
includes specific guidance for adoption of the latest building codes and direction for developing energy
performance paths to zero carbon building by 2030 and the strategy to update codes to address indoor
and outdoor water efficiency for existing and new developments.
•The Housing Strategic Plan (2021) includes a vision that “[e]veryone has healthy, stable housing they can
afford,” and includes specific strategies to promote visitability, affordability, and connecting housing and
health, all of which align with Our Climate Future.
•The Water Efficiency Plan (2015) includes a goal of reducing use to 130 gallons per capita per day by
2030. One of the five strategic focus areas of this Plan is to encourage greater integration of water
efficiency into land use planning and building codes.
•Electric Vehicle Readiness Roadmap (2018) establishes a vision, goals, and clearly defined roles for City
of Fort Collins Departments, the private sector, and the Fort Collins community to inform polic ies to
increase EV charging infrastructure.
BOARD / COMMISSION AND PUBLIC ENGAGEMENT
Staff has engaged in additional public engagement since February 15 to gather additional input about EV
requirements for affordable housing developments:
•Affordable Housing Focus Group – 2/18/2022
•Housing Catalyst – 2/24/2022 and 3/8/2022
•Affordable Housing Board – 3/3/2022 (ATTACHMENT 5)
•Downtown Development Authority – 3/25/2022
Overall, suggestions from these groups encouraged staff to provide an option for affordabl e housing that was
aligned with the current requirements of the Colorado Housing Finance Authority (CHFA). Option 2 reflects
Agenda Item 16
Item # 15 Page 5
this suggestion. Staff also heard that requirements above and beyond Option 3 should include a mechanism to
offset the additional cost for affordable housing developments above and beyond what is available through the
Colorado Energy Office and Charge Ahead Colorado.
Presentations to City Boards and Commissions and other community groups:
City Boards and Commissions
Building Review Commission (9/30/21) Poudre Fire Authority Board (10/5/21)
Affordable Housing Board (10/7/21) Planning and Zoning Commission (10/15/21)
Energy Board (10/15/21 & 1/13/2022) Natural Resource Advisory Board (10/20/21)
Water Commission (10/21/21) Commission on Disability (10/21/21)
External groups:
Fort Collins Chamber of Commerce (9/24/21) Fort Collins Board of Realtors (10/12/21)
Northern Colorado Home Builders Association
(10/1/21)
Affordable Housing Focus Group (12/17/2021)
ATTACHMENTS
1.Option 1 (PDF)
2.Option 2 (PDF)
3.Option 3 (PDF)
4.Option 4 (PDF)
5.Affordable Housing Board Minutes (draft)(PDF)
6.Powerpoint Presentation (PDF)
7.Ordinance No. 021, 2022 (PDF)
8.Ordinance No. 022, 2022 (PDF)
9.Ordinance No. 023, 2022 (PDF)
10.Ordinance No. 024, 2022 (PDF)
11.Ordinance No. 025, 2022 (PDF)
12.Ordinance No. 026, 2022 (PDF)
13.Ordinance No. 027, 2022 (PDF)
14.Ordinance No. 028, 2022 (PDF)
15.Ordinance No. 029, 2022 (PDF)
ATTACHMENT 1
OPTION 1: 10% EV-CAPABLE FOR AFFORDABLE HOUSING
(As shown in IBC Table 3604.5 set forth in numbered paragraph 51 of
Ordinance No. 021, 2022 published for second reading)
TABLE 3604.5
City of Fort Collins
Occupancy
Classification for EV
Charging Infrastructure
EVSE -
installed EV-Ready EV-Capable
Tier 1
Residential 10% 20% 40%
Affordable housing N/A N/A 10%
Tier 2
Mercantile 5% 15% 20%
Assembly 5% 15% 20%
Institutional 5% 15% 20%
Business 5% 15% 20%
Educational 5% 15% 20%
Factory 5% 15% 20%
Tier 3
High hazard 1% 5% 15%
Storage 1% 5% 15%
Utility and misc. group 1% 5% 15%
ATTACHMENT 2
OPTION 2: 10% EV-CAPABLE +
10% EV-READY FOR AFFORDABLE HOUSING
(Replaces IBC Table 3604.5 set forth in numbered paragraph 51 of
Ordinance No. 021, 2022 adopting the 2021 IBC)
TABLE 3604.5
City of Fort Collins
Occupancy
Classification for EV
Charging Infrastructure
EVSE -
installed EV-Ready EV-Capable
Tier 1
Residential 10% 20% 40%
Affordable housing N/A 10% 10%
Tier 2
Mercantile 5% 15% 20%
Assembly 5% 15% 20%
Institutional 5% 15% 20%
Business 5% 15% 20%
Educational 5% 15% 20%
Factory 5% 15% 20%
Tier 3
High hazard 1% 5% 15%
Storage 1% 5% 15%
Utility and misc. group 1% 5% 15%
ATTACHMENT 3
OPTION 3: 10% EV-CAPABLE + 10% EV-READY + ONE EVSE INSTALLED
FOR AFFORDABLE HOUSING
(Replaces IBC Table 3604.5 set forth in numbered paragraph 51 of
Ordinance No. 021, 2022 adopting the 2021 IBC)
TABLE 3604.5
City of Fort Collins
Occupancy
Classification for EV
Charging Infrastructure
EVSE -
installed EV-Ready EV-Capable
Tier 1
Residential 10% 20% 40%
Affordable housing Minimum of 1
space 10% 10%
Tier 2
Mercantile 5% 15% 20%
Assembly 5% 15% 20%
Institutional 5% 15% 20%
Business 5% 15% 20%
Educational 5% 15% 20%
Factory 5% 15% 20%
Tier 3
High hazard 1% 5% 15%
Storage 1% 5% 15%
Utility and misc. group 1% 5% 15%
ATTACHMENT 4
OPTION 4: 20% EV-CAPABLE + 15% EV-READY
FOR AFFORDABLE HOUSING
(Replaces IBC Table 3604.5 set forth in numbered paragraph 51 of
Ordinance No. 021, 2022 adopting the 2021 IBC)
TABLE 3604.5
City of Fort Collins
Occupancy
Classification for EV
Charging Infrastructure
EVSE -
installed EV-Ready EV-Capable
Tier 1
Residential 10% 20% 40%
Affordable housing N/A 15% 20%
Tier 2
Mercantile 5% 15% 20%
Assembly 5% 15% 20%
Institutional 5% 15% 20%
Business 5% 15% 20%
Educational 5% 15% 20%
Factory 5% 15% 20%
Tier 3
High hazard 1% 5% 15%
Storage 1% 5% 15%
Utility and misc. group 1% 5% 15%
AFFORDABLE HOUSING BOARD
REGULAR MEETING
3 /3/2022 – MINUTES - Excerpt Page 1
March 3, 2022, 4:00-6:00pm
Remote/Online via Zoom due to COVID-19 DRAFT
CALL TO ORDER
At 4:02 the meeting was called to order by Tatiana Zentner
1.ROLL CALL
•Board Members Present: Tatiana Zentner, John Singleton, Kristin Fritz, Bob Pawlikowski, Seth Forwood
and Stefanie Berganini joined in progress.
•Board Members Absent: Jennifer Bray
•Staff Members Present:
Sue Beck-Ferkiss, Staff Liaison – City of Fort Collins
Taylor Reynolds, Minutes – City of Fort Collins
•Guests Present:
Ryan Jones – RCH Jones Consulting
Michele Christensen & Traci McGraw – Housing Catalyst
*******Excerpt Related to this Resolution Begins Below*******
5.NEW BUSINESS
b.Housing Strategic Plan – Sue Beck-Ferkiss
•Building Code Update
•Sue presented an overview of the building code updates approved adopted by City Council on
first reading in October 2021February 15, 2022. The updates were based on the 2021
International Building Code and Energy Conservation Code (IBC). At that time, City Council also
requested additional information specifically about how electric vehicle (EV) charging
requirements would affect affordable housing and City staff provided three alternative options
to the IBC code.
ATTACHMENT 5
AFFORDABLE HOUSING BOARD
REGULAR MEETING
3 /3/2022 – MINUTES - Excerpt Page 2
• 2021 IBC Reference: 10% EV installed, 20% EV ready, 40% EV capable
• Alternative Options for Affordable Housing:
• Option 1 – 10% EV Capable
• Option 2 – 10% EV Capable + 10% EV Ready
• Option 3 – 10% EV Capable + 10% EV Ready + One EVSE Installed
• Board members engaged in a thoughtful discussion regarding the upfront costs of installations and
higher costs of retrofitting for charging stations in the future at affordable housing developments.
• The Affordable Housing Board thanks City Council for considering alternatives to the IBC 2021 EV
requirements in order to facilitate the development of more affordable housing units. Providing
lower standards for affordable housing projects, which each of the staff options represented,
removes a potential barrier to creating more affordable housing.
Motion by Stefanie Berganini. Seconded by Seth Forwood.
Approved 6-0.
2021 Building Code Update
April 5, 2022
Marcus Coldiron
Chief Building Official
Kirk Longstein
Project Manager
Brad Smith
Project Manager -Energy Code
Russ Hovland
Senior Plans Examiner
ATTACHMENT 6
2CityPlan and Policy Alignment
3Staff Recommendation
Background
•Nine ordinances were adopted on first reading February 15; EV Work Session March 8
•Code's Purpose: Safeguard public health, safety, and general welfare by regulating structural strength
and stability, sanitation, light and ventilation, and energy conservation
Recommendation
•Staff recommend adoption of the Code package including changes to Ordinance No. 021, 2022
(included in published Ordinance)
•Add Single User Gender Neutral Restrooms
•Select EV Infrastructure Option for Affordable Housing
•Option 1 (Included in published Ordinance)
•Option 2-4 (See AIS attachments 2-4)
•Other Business Item: Provide direction for additional resources to support EV requirements in 2022
4Benefits
Community-wide Benefits of staying current
on Building Code Adoption Cycle
•Smaller incremental construction costs
•More efficient building and lower utility bills
•Avoided retrofit cost
•Respond to the Climate Emergency by reducing carbon emissions
5Code Impact -Example
$0
$20
$40
$60
$80
$100
$120
$140
$160
2015 2018 2021
Cost of Construction Increase due to code updates
Building Codes account for a
3% average increase to the
total cost of construction.
Building Codes account for a
3% average increase to the
total cost of construction.
Multi Family Development Scenario
To tal Cost of Construction/Sq Ft 2015-2018
6Changes since First Reading Adoption
Three Changes Since First Reading Adoption
•Add Single User Gender Neutral Restrooms
•Clarify Electrical Vehicle Charging Definitions
•Select Alternative EV Infrastructure Option for Affordable Housing
7Changes Since First Reading Adoption
Clarify Electrical Vehicle Charing Definitions
•Add Affordable Housing reference as defined by Sec. 5.1 of the Land Use Code
•Provide reference to the National Electric Code and clarify the physical space
requirements in the electrical room.
•Integrate the definition of Electric Vehicle Load Management System and allow
for more flexibility within future electrical system design per the National Electric
Code.
8Changes Since First Reading Adoption
Select Alternative EV Infrastructure Option for Affordable Housing
1.Option 1 –10% EV Capable (reflected in the second reading Ordinance as-published)
2.Option 2 –10% EV Capable + 10% EV Ready
3.Option 3 –10% EV Capable + 10% EV Ready + One EVSE Installed
4.Option 4 -20% EV Capable + 15% EV Ready
Key Considerations
1.Option 1 -Carries forward the current 2018 Building Code requirements for Affordable Housing projects.
2.Option 2 -Aligns with Colorado Housing and Finance Authority (CHFA).
3.Option 3 -Eligible for the $9,000 grant from the State of Colorado.
4.Option 4 –Council suggested requirements with recognition that additional resources should be considered
9Changes Since First Reading Adoption
Stakeholder Feedback
•Overall support for the EV charging infrastructure and appreciate alternative options that reduces cost.
•Support alternative options that align with the current requirements of the Colorado Housing Finance Authority.
•Any EV requirements above and beyond Option 3 should include a mechanism to offset the additional cost.
•Seeking more Utilities resources and business education to support ongoing operations of EV chargers.
10Discussion
Recommendations
1) Adoption of the Code package including published changes to Ordinance No. 021, 2022
•Add Single User Gender Neutral Restrooms (included in published Ordinance)
•Clarify Electrical Vehicle Charging Definition (included in published Ordinance)
•Select EV Infrastructure Option for Affordable Housing
•Option 1 (included in published Ordinance)
•Option 2-4 (See AIS attachments 2-4)
2) Other Business Item: Provide direction to staff regarding off-cycle funding that supports cost-sharing
of EV requirements for affordable housing projects this year.
Back up Slides
12Gender-neutral restrooms
Floorplan examples for the Suggested Gender-Neutral Bathroom amendments
Single User Bathroom
13Electric Vehicle Charging Infrastructure -Definitions
·EVSE-INSTALLED –Ty pe 2 charging stations, installed during construction.
·EV READY -Full circuit installations including 208/240V, 40-amp panel capacity, raceway, wiring,
receptacle, and overprotection devices similar to a dryer circuit.
·EV CAPA BLE –Installation of panel space and conduit (raceway) to accommodate the future build-out of
EV charging with 208/240 V, 40-amp circuits EV Infrastructure.
·Electric Vehicle Load Management System. A s ystem designed to allocate charging capacity among
multiple electric vehicle supply equipment that complies with the current National Electric Code (NEC). If
an Electric Vehicle Load Management System is specified, then the electrical service requirements for each parking
space requirement may be adjusted per the current NEC.
14EV Charging Building Code requirements for Af fordable Housing
City of Fort Collins Occupancy
Classification for EV Charging
Infrastructure
EVSE -installed EV -Ready EV –capable
Tier 1 •••
Residential 10%20%40%
Tier 2
Affordable Housing XX%XX%XX%
Tier 3 •••
Mercantile 5%15%20%
Assembly 5%15%20%
Institutional 5%15%20%
Business 5%15%20%
Educational 5%15%20%
Factory 5%15%20%
Tier 4 •••
High hazard 1%5%15%
Storage 1%5%15%
Utility and misc. group 1%5%15%
Building Code Updates –Multi-family
15
For a multi-family residence of 55 units, it is estimated that 87 parking spaces would be required by the LUC. Assuming
Tier 1 implementation of the proposed local amendment for EVE charging infrastructure, an estimated $125k -$232k
would be added to the cost of construction. This would represent an increase in cost of 1.9% -3.5%.
$0
$1,000,000
$2,000,000
$3,000,000
$4,000,000
$5,000,000
$6,000,000
$7,000,000
$8,000,000
Without EV Charging
Infrastrucutre
Amendment
With EV Charging
Infrastructure
Amendment (LOW)
With EV Charging
Infrastructure
Amendment (HIGH)
2021/2022 Total Cost of Construction
Cost of Construction Cost of Compliance Cost of Compliance - EV Charging Infrastructure
EV Charging and Electricity Bills
•EV charging is considered a “product” not a “service”
•Electricity use typically tied to commercial building meter
•Options for managing EV electricity costs –
“behind the meter” building owner decisions
ü Include as operating expense
ü Design fee structure to charge individual users
Fort Collins Utilities
Commercial Rate
Electric Preferred vs Electric Ready
Electric-Preferred:
Extra efficiency or renewable
requirements for new construction with
natural gas.
Demonstrate extra efficiency through
performance path modeling.
Electric Ready:
Buildings constructed with natural gas
must be pre-wired for future electric
systems and appliances and electric
panel must provide capacity for future
electric systems and appliances.
vs
ELECTRIC HEAT.Code requires a primary heat source that is electric. If all-electric, a ground-source electric heat
pump or a cold climate heat pump designed to heat at the Winter Outdoor, Design Temp is required.
Building electrification. All newly constructed buildings shall be constructed as an all-electric building or a *mixed-
fuel building that is pre-wired for future electric space heating, water heating, cooking and clothes drying equipment.
City of Fort Collins Electric Ready proposal
*mixed-fuel: natural gas and electric
Cost to the Utilities Rate Payer
Adopting energy codes result in a steady
lowering of utility costs.
Without remaining current on building code adoption
over the last two cycles,the average household monthly
utility costs would have been $20 higher
Efficiency gains have been largely stagnant
since 2012 energy code adoption.
19Plumbing Codes for Greywater
11 /23/21
Council Work
Session
Jan-Feb 2022
•Draft Ordinance
•Stakeholder
Engagement
04/05/22
Adopt plumbing
codes to prepare
for graywater
ord.
April-June 2022
Public &
Stakeholder
Engagement
08/16/22
Council
Ordinance 1st
reading
Ad option of the proposed codes include the Colorado Plumbing Code
•Enables graywater with design and installation standards, following adoption of a
graywater ordinance by City Council.
Graywater Ordinance Timeline
Fort Collins Building Permits
Notes:
Building permit numbers reflect national and regional market trends not building code adoption cycles
New permit rebound in 2021 since the Governor ’s 2020 COVID orders.
Fort Collins buildable land area is constrained by the GMA.
Fort Collins receives more permit applications for Multifamily dwelling units compared to neighboring communities.
21I-Codes + Local Amendment Community Feedback
Council work
session or
adoptionConcerns…………………………….……………………………………SupportConcerns…………………………….……………………………………Support
Uncertainty with Utilities capacity
to meet increased EV and electric
ready building loads
Reduce utility bills
Increased first year construction
costs
Housing Affordability
Land Use Code Parking
Requirements
Concerns…………………………….……………………………………SupportConcerns…………………………….……………………………………Support
More resilient building product,
consumer choices, and avoided
retrofit costs
ORDINANCE NO. 021, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 2 OF THE
CODE OF THE CITY OF FORT COLLINS FOR THE PURPOSE OF
REPEALING THE 2018 INTERNATIONAL BUILDING CODE AND
ADOPTING THE 2021 INTERNATIONAL BUILDING CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both to align the publication years of the codes and
because the 2021 publications contain improvements in construction code regulation; and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interests of the health,
safety and welfare of the City and its residents that the 2021 International Building Code, be
adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter Article II, Section 7, City Council may enact any
ordinance which adopts a code by reference in whole or in part provided that before adoption of
such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
- 2 -
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Building Code
(“IBC”) and hereby adopts 2021 IBC as amended by this Ordinance.
Section 3. That Section 5-26(a) of the Code of the City of Fort Collins is hereby
amended to read as follows:
(a) Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-
16-202 and Article II, Section 7 of the Charter, the City Council has adopted the 2021
International Building Code (2021 IBC) published by the International Code Council, as
amended by the City, which shall have the same force and effect as though set forth in full
herein. The subject matter of the codes adopted herein includes comprehensive provisions
and standards regulating the erection, construction, enlargement, alteration, repair, moving,
removal, conversion, demolition, occupancy, equipment, use, height, area and maintenance
of buildings and structures exclusive of detached one- and two-family dwellings and
multiple single-family dwellings (townhouses) not more than three (3) stories above grade
and their accessory structures, for the purpose of protecting the public health, safety and
general welfare. As provided in the 2021 International Building Code, Appendices are not
adopted except as expressly set forth in § 5-27.
Section 4. That Section 5-27 of the Code of the City of Fort Collins is hereby repealed
and reenacted to read as follows:
Sec. 5-27. Amendments and Deletions to the 2021 International Building Code.
The 2021 International Building Code adopted in §5-26 is hereby amended to read as
follows:
1. Section 101. Title is hereby amended to read as follows:
101.1. Title. These regulations shall be known as the Building Code of the City of Fort
Collins, hereinafter referred to as “this code.”
- 3 -
2. Sections 101.4.1 through 101.4.7 Referenced codes, are hereby deleted in their
entirety and replaced with the following:
[A] 101.4 Referenced codes. The other codes specified in Sections 101.4.1 through
101.4.11 and referenced elsewhere in this code shall be considered to be part of the
requirements of this code to the prescribed extent of each such reference.
101.4.1 Gas. All references to the International Fuel Gas Code shall mean the fuel gas
code currently in effect as enacted by the City.
101.4.2 Mechanical. All references to the International Mechanical Code shall mean
the mechanical code currently in effect as enacted by the City.
101.4.3 Plumbing. All references to the International Plumbing Code shall mean the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code
currently in effect as enacted by the City.
101.4.4 Property Maintenance. All references to the International Property
Maintenance Code shall mean the property maintenance code currently in effect as
enacted by the City.
101.4.5 Fire Prevention. All references to the International Fire Code shall mean the
fire code currently in effect as enacted by the City.
101.4.6 Energy. All references to the International Energy Conservation Code shall
mean the energy code currently in effect as enacted by the City.
101.4.7 Existing buildings. All references to existing buildings shall be regulated
pursuant to the adopted International Property Maintenance Code or the International
Existing Building Code currently in effect as enacted by the City.
101.4.8 Residential. All references to the International Residential Code shall mean
the residential code currently in effect as enacted by the City.
101.4.9 Areas prone to flooding. All references to “flood hazard” and “areas prone to
flooding” in this code and appendices adopted therewith subject to applicable
regulations and requirements set forth in the City Code, “Chapter 10, Flood Prevention
and Protection.”
101.4.10 Electrical. All references to the City of Fort Collins Electrical Code shall
mean the National Electrical Code currently in effect as enacted by the City.
101.4.11 Pool and Spa. All references to the Pool and Spa Code shall mean the
International Swimming Pool and Spa Code currently in effect as enacted by the City.
- 4 -
3. Section 103 CODE COMPLIANCE AGENCY is hereby deleted in its entirety and
replaced with the following:
SECTION 103 CODE ADMINISTRATION
103.1 Entity charged with code administration. The Community Development and
Neighborhood Services Department (CDNS) is charged with the administration and
enforcement of this code.
The building official, appointed by the City Manager, is charged with the direct overall
administration and enforcement of this code and, in the performance of said duties, may
delegate the necessary authority to the appropriate technical, administrative, and
compliance staff under the supervision the building official.
4. Section 105.2 Work exempt from permit, Building, is hereby amended to read as
follows; however, the subsections for Electrical, Gas, Mechanical and Plumbing are
retained in their entirety: 105.2 Work exempt from permit. Exemptions from permit requirements of this code shall not be deemed to grant authorization for any work to be done in any manner in violation of the provisions of this code or any other laws or ordinances of this jurisdiction. Permits shall not be required for the following:
Building:
1. One-story, detached, accessory structures used for lawn and garden equipment
storage, tool storage and similar uses, including arbors, pergolas, and similar
structures, provided that the floor area is not greater than 120 square feet (11
m2) nor greater than 8 feet (2.438 m) in height measured from grade, the
structures do not house flammable liquids in quantities exceeding 10 gallons
(38 L) per building, and the structures are located at least 3 feet (0.914 m) from
an adjoining property line.
2. Fences not over 6 feet (1829 mm) high.
3 Oil derricks
4. Retaining walls that are not over 4 feet (1219 mm) in height measured from the
low side grade to the top of the wall, unless supporting a surcharge provided
the horizontal distance to the next uphill retaining wall shall be at least equal to
the total height of the lower retaining wall.
5. Water tanks supported directly upon grade if the capacity is not greater than
5,000 gallons (18,927 L) and the ratio of height to diameter or width is not
greater than 2:1.
- 5 -
6. Sidewalks and driveways not more than 30 inches (762 mm) above adjacent
grade, and not over any basement or story below and are not part of an
accessible route.
7. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish
work.
8. Temporary motion picture, television and theater stage sets and scenery.
9. Prefabricated swimming pools accessory to a Group R-3 occupancy that are less
than 24 inches (610 mm) deep, are not greater than 5,000 gallons (18 925 L)
and are installed entirely above ground.
10. Shade cloth structures constructed for nursery or agricultural purposes, not
including service systems. Hoop houses constructed with a flexible frame such
as PVC tubing used for starting plants.
11. Swings and other playground equipment or play structures accessory to
detached one- and two-family dwellings provided that the floor area is not
greater than 120 square feet (11.15 m2) nor greater than 8 feet (2.438 m) in
height measured from grade, including no more than one elevated playhouse or
play structure per lot designed, and said equipment or structure is used
exclusively for play. Elevated play houses or play structures shall not exceed
64 square feet (5.9 m2) of floor area nor 6 feet (1.82 m) in height as measured
from the floor to the highest point of such structure.
12. Window awnings supported by an exterior wall that do not project more than
54 inches (1372 mm) from the exterior wall and do not require additional
support. Storm windows, storm doors, and rain gutter installation except that,
for structures fifty years of age or older, historic review pursuant to Chapter 14
of the City Code first must be completed.
13. Nonfixed and movable fixtures, cases, racks, counters and partitions not over 5
feet 9 inches (1753 mm) in height.
14. Decks not exceeding 200 square feet (18.58 m2) in area that are not more than
30 inches (762 mm) above grade, are not attached to a building, and do not
serve an exit door required by Chapter 10.
15. Roofing repair or replacement work not exceeding one square (100 square feet)
of covering per building.
16. Replacement of nonstructural siding that is not part of a fire-rated assembly
when the removal of siding is performed in accordance with State laws
regarding asbestos and lead paint except that, for structures fifty years of age or
older, historic review pursuant to Chapter 14 of the City Code first must be
completed.
- 6 -
5. A new Section 105.2.1.1 Emergency disaster no-fee permit is hereby added to read
as follows:
105.2.1.1 Emergency disaster no-fee permit. When the building official determines
there is an emergency/disaster event that has caused substantial damage to structures
within the City, the building official can issue a no-fee permit to make temporary
repairs to a structure to address damages caused by the emergency/disaster event to
make the structure safe and/or allow occupancy. A temporary permit will expire after
180 days, at which time a regular building permit will need to be obtained to otherwise
bring the structure into compliance with this code. The building official can extend a
temporary permit under this section for good cause.
6. Section 105.3.2 Time limitation of application is hereby amended to read as follows:
105.3.2 Time limitation of application. An application for a permit for any proposed
work shall be deemed to have been abandoned 180 days after the date of filing, unless
such application has been pursued in good faith or a permit has been issued; except that
the building official is authorized to grant one or more extensions of time for additional
periods not exceeding 180 days each. The extension shall be requested in writing and
justifiable cause demonstrated. Applications that have expired for 30 days or more may
be considered void.
7. Section 105.5 Expiration is hereby amended to read as follows:
105.5 Expiration. Every permit issued shall become invalid unless the work on the site
authorized by such permit is commenced within 180 days after its issuance, or if the
work authorized on the site by such permit is suspended or abandoned for a period of
180 days after the time the work is commenced. The building official is authorized to
grant, in writing, one or more extensions of time, for periods not more than 180 days
each. The extension shall be requested in writing and justifiable cause demonstrated.
Both prior to and subsequent to the effective date of this code, any work authorized by
a permit regulated by this code or any other building construction code administered
by the building official that involves the construction or alteration of an exterior
building component, assembly or finish material, such as the foundation, wall and roof
framing, sheathing, siding, fenestration, and roof covering, shall be fully finished for
permanent outdoor exposure within 24 months of the date of the issuance of such
permit.
8. A new Section 105.8 Transfer of permits is hereby added to read as follows:
105.8 Transfer of permits. A current valid building permit may be transferred from
one party to another upon written application to the building official with consent of
both parties. When any changes are made to the original plans and specifications that
substantially differ from the plans submitted with the permit, as determined by the
- 7 -
building official, a new plan review fee shall be paid as calculated in accordance with
Section 109. A fee of $50 shall be paid to cover administrative costs for all building
permit transfers. No change shall be made to the expiration date of the original permit.
9. SECTION 106 FLOOR AND ROOF DESIGN LOADS is hereby deleted in its
entirety.
10. Section 107.3.1 Approval of construction documents is hereby amended to read as
follows:
107.3.1 Approval of construction documents. When the building official issues a
permit, the construction documents shall be approved, in writing or by stamp indicating
the approved permit number. One set of construction documents so reviewed shall be
retained by the building official. The other set shall be returned to the applicant, shall
be kept at the site of work and shall be open to inspection by the building official or a
duly authorized representative.
11. SECTION 109 FEES is hereby deleted in its entirety and replaced with the following:
SECTION 109 FEES
109.1 Payment of fees. No permit shall be valid until applicable fees prescribed by
Chapter 7.5 of the City Code have been paid, except for emergency permits issued
pursuant to Section 105.2.1.
109.2 Work commencing before permit issuance. In addition to the penalties set
forth in Section 114.4, any person or firm who, before obtaining the necessary
permit(s), commences any construction of, or work on, a building, structure, electrical,
gas, mechanical or plumbing system that is not otherwise exempt from obtaining a
permit, may be subject to a stop work order and a work without a permit fee in addition
to the required permit fee as established by the building official.
12. Section 111.2 Certificate issued is hereby amended to read as follows:
111.2 Certificate issued. After the building official inspects the building or structure
and does not find violations of the provisions of this code or other laws that are enforced
by CDNS, the building official shall issue a certificate of occupancy that may contain
the following:
1. The permit number.
2. The address of the structure.
3. The name and address of the owner or the owner’s authorized agent.
4. A description of that portion of the structure for which the certificate is issued.
5. A statement that the described portion of the structure has been inspected for
compliance with the requirements of this code.
6. The name of the building official.
7. The edition of the code under which the permit was issued.
- 8 -
8. The use and occupancy, in accordance with the provisions of Chapter 3.
9. The type of construction as defined in Chapter 6.
10. The design occupant load.
11. Where an automatic sprinkler system is provided, whether the sprinkler system
is required.
12. Any special stipulations and conditions of the building permit.
13. SECTION 113 MEANS OF APPEALS is hereby deleted in its entirety and replaced
with the following:
SECTION 113 MEANS OF APPEALS
113.1 General. The Building Review Commission (hereafter “Commission”)
established in § 2-173 of the City Code is hereby empowered in accordance with the
procedures set forth in this Section and as authorized under § 2-172 of the City Code
to hear and decide appeals of orders, decisions, or determinations made by the building
official relative to the application and interpretation of this code; to determine the
suitability of alternative materials or alternative methods of construction; and to grant
permit extensions and reinstatements as prescribed by Section 105.5. The building
official shall serve as the Secretary of the Commission. The Commission shall adopt
rules of procedure in accordance with § 2-172 of the City Code for conducting its
business and shall render all decisions and findings in writing.
113.2 Applications/Hearings. When a building permit applicant or a holder of a
building permit desires relief from any decision of the building official related to the
enforcement of this code, except as is otherwise limited in Section 113.4, such building
permit applicant, building permit holder, or representative thereof may appeal the
decision of the building official to the Commission, stating that such decision by the
building official was based on an erroneous interpretation of the building regulations
or that an alternative design, alternative materials and/or the alternative methods of
construction proposed by the appellant are equivalent to those prescribed by this code,
considering structural strength, effectiveness, fire resistance, durability, safety and any
other pertinent factors.
The Commission shall hear and decide all appeals made to it and shall have the
authority to rule in favor of the appellant when the Commission determines that the
interpretation of the building regulations of the City by the building official was
erroneous, or when the Commission determines an alternative design, alternative
materials and/or the alternative methods proposed by the appellant are equivalent to
those prescribed by this code, considering structural strength, effectiveness, fire
resistance, durability, safety and any other pertinent factors. The Commission shall
require that sufficient evidence be submitted to substantiate any claims made regarding
the proposed alternative design, alternative materials and/or alternative methods of
construction.
- 9 -
113.3 Fees and Notification. Persons desiring to appeal to the Commission any
decision of the building official as provided in this Section shall, file a request on the
form promulgated by the building official and pay the applicable fee at the time of
filing. Written notice of hearings shall be given to the Appellant and, with respect to
appeals concerning accessibility under Chapter 11 of this code, to the City staff liaison
for the Disability Advisory Board, at least four days prior to the hearing by delivering
the same to such party's last known email address.
113.4 Limitations. The Building Review Commission shall have no authority with
respect to any of the following functions:
1. The administration of this code except as expressly provided otherwise;
2. Waiving requirements of this code, except as provided in this Section;
3. Modifying the applicable provisions of, or granting variances to, this code, or
approving the use of alternative designs, alternative materials and/or
alternative methods of construction except as provided for in this Section and
based upon a specific appeal from a determination or decision of the building
official on an individual case basis; and
4. Modifying, interpreting, or ruling on the applicability or intent of the zoning
and land use regulations or other laws of the City except as expressly
empowered otherwise.
14. Section 114.4 Violation Penalties is hereby amended to read as follows:
114.4 Violation penalties. Any person who violates a provision of this code or fails to
comply with any of the requirements thereof or who erects, constructs, alters or repairs
a building or structure in violation of the approved construction documents or directive
of the building official, or of a permit or certificate issued under the provisions of this
code, commits a civil infraction and is subject to the provisions contained in § 1-15(f)
of the City Code. Each day that a violation continues shall be deemed a separate
offense.
15. SECTION 202 DEFINITIONS is hereby amended to modify, or add, in alphabetical
order, the following definitions:
SECTION 202 DEFINITIONS
COMMISSIONING. A process to verify and document that the selected building and
systems have been designed, installed, and function in accordance with the construction
documents, manufacturers’ specifications, and minimum code requirements.
DWELLING. A building used exclusively for residential occupancy and for permitted
accessory uses, including single-family dwellings, two-family dwellings and multi-
family dwellings. The term dwelling shall not include hotels, motels, homeless shelters,
seasonal overflow shelters, tents or other structures designed or used primarily for
temporary occupancy. Any dwelling shall be deemed to be a principal building.
- 10 -
DWELLING UNIT. One or more rooms and a single kitchen and at least one
bathroom, designed, occupied or intended for occupancy as separate quarters for the
exclusive use of a single family for living, cooking and sanitary purposes, located in a
single-family, two-family or multi-family dwelling or mixed-use building.
ROOM, SLEEPING (BEDROOM). A habitable room within a dwelling or other
housing unit designed primarily for the purpose of sleeping. The presence of a bed, cot,
mattress, convertible sofa or other similar furnishing used for sleeping purposes shall
be prima facie evidence that such space or room is a sleeping room. The presence of
closets or similar storage facilities shall not be considered relevant factors in
determining whether or not a room is a sleeping room.
TOWNHOUSE. A single-family dwelling unit constructed as part of a group of two
or more attached individual dwelling units each of which is separated from the other
from the foundation to the roof and is located entirely on a separately recorded and
platted parcel of land (site) bounded by property lines, which parcel is deeded
exclusively for such single-family dwelling.
VOLATILE ORGANIC COMPOUND (VOC): Any compound of carbon,
excluding carbon monoxide, carbon dioxide, carbonic acid, metallic carbides or
carbonates, and ammonium carbonate, which participates in atmospheric
photochemical reactions. VOCs include a variety of chemicals, some of which may
have short-and long-term adverse health effects emitted as gases from certain solids or
liquids.
16. Section 310.4.1 Care facilities within a dwelling is hereby amended to read as
follows:
310.4.1 Care facilities within a dwelling. Except as in provided in C.R.S. § 26-6-
104.5 (concerning family child care homes), care facilities for five or fewer persons
receiving care that are within a single-family dwelling are permitted to comply with the
International Residential Code.
17. Section 310.4.2 Lodging houses is hereby amended to read as follows:
310.4.2 Lodging houses. Owner-occupied lodging houses with five or fewer guest
rooms and 10 or fewer total occupants shall be permitted to be constructed in
accordance with the International Residential Code.
18. A new Section 502.2 Premises identification during construction is hereby added to
read as follows:
502.2 Premises identification during construction. The approved permit number
and street address shall be displayed and be plainly visible and legible from the public
- 11 -
street or road fronting the property on which any building is being constructed or
remodeled.
19. A new Section 503.1.2.1 Common ownership is hereby added to read as follows:
503.1.2.1 Common ownership. The fire separation distance and exterior wall/opening
protection requirements of sections 705.5 and 705.8 do not apply for a structure built
and located on or across a property line, provided that the property on both sides of the
property line is held in common ownership and will remain so for the duration that said
building is located across that property line. All other code requirements and fire
separation distances to other property lines and assumed property lines set forth in
section 705.3 shall apply.
20. CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS is hereby
deleted in its entirety and replaced with the following:
CHAPTER 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS.
All Fire Protection and Life Safety Systems regulated by this chapter shall comply
with the applicable provisions of the current International Fire Code as adopted by
the City.
21. Section 1010.1.4 Floor elevation is hereby amended to read as follows:
1010.1.4 Floor elevation. There shall be a floor or landing on each side of a door. Such
floor or landing shall be at the same elevation on each side of the door. Landings shall
be level except for exterior landings, which are permitted to have a slope not to exceed
0.25 unit vertical in 12 units horizontal (2-percent slope). All exterior steps, slabs,
walks, decks and patios serving as exterior door landings or exterior stairs shall be
adequately and permanently secured in place by approved methods to prevent such
landings or stairs from being undermined or subject to significant displacement due to
improper placement of supporting backfill or due to inadequate anchoring methods.
Exceptions:
1. At doors serving individual dwelling units or sleeping units in Groups R-2
and R-3 : a door is permitted to open at the top step of an interior flight of
stairs, provided that the door does not swing over the top step.
2. At exterior doors serving Groups F, H, R-2 and S and where such doors are
not part of an accessible route, the landing at an exterior door shall not be
more than 7 inches (178 mm) below the landing on the egress side of the
door, provided that the door, other than an exterior storm or screen door,
does not swing over the landing.
3. At exterior doors serving Group U and individual dwelling units and sleeping
units in Groups R-2 and R-3, and where such units are not required to be
Accessible units, Type A units or Type B units, the landing at an exterior
- 12 -
doorway shall be not more than 73/4 inches (197 mm) below the landing on
the egress side of the door. Such doors, including storm or screen doors,
shall be permitted to swing over either landing.
4. Variations in elevation due to differences in finish materials, but not more
than 1/2 inch (12.7 mm).
5. Exterior decks, patios or balconies that are part of Type B dwelling units or
sleeping units, that have impervious surfaces and that are not more than 4
inches (102 mm) below the finished floor level of the adjacent interior space
of the dwelling unit or sleeping unit.
6. Doors serving equipment spaces not required to be accessible in accordance
with Section 1103.2.9 and serving an occupant load of five or less shall be
permitted to have a landing on one side to be not more than 7 inches (178
mm) above or below the landing on the egress side of the door.
7. Exterior doors serving individual dwelling units, other than the main
entrance door to a dwelling unit, may open at one intervening exterior step
that is equally spaced between the interior floor level above and exterior
landing below, provided that the step has a minimum tread depth of 12
inches, a maximum riser height of 7 ¾ inches (19.68cm), and a minimum
width equal to the door width, and further provided that the door does not
swing over the step.
22. Section 1011.11 Handrails is hereby amended to read as follows:
1011.11 Handrails. Flights of stairways of more than 1 riser shall have handrails on
each side and shall comply with Section 1014. Where glass is used to provide the
handrail, the handrail shall also comply with Section 2407.
Exceptions:
1. Flights of stairways within dwelling units and flights of spiral stairways are
permitted to have a handrail on one side only.
2. Decks, patios and walkways that have a single change in elevation where the
landing depth on each side of the change of elevation is greater than what
is required for a landing do not require handrails.
3. In Group R-3 occupancies, a change in elevation consisting of a single riser
at an entrance or egress door does not require handrails.
4. Changes in room elevations of three or fewer risers within dwelling units
and sleeping units in Groups R-2 and R-3 do not require handrails.
5. Where a platform lift is in a stationary position and the floor of the platform
lift serves as the upper landing of a stairway, handrails shall not be required
on the stairway, provided that all of the following criteria are met:
5.1. The stairway contains not more than two risers.
5.2. A handhold, positioned horizontally or vertically, is located on one side of
the stairway adjacent to the top landing.
5.3. The handhold is located not less than 34 inches (864 mm) and not more than
42 inches (1067 mm) above the bottom landing of the stairway.
- 13 -
5.4. The handhold gripping surface complies with Section 1014.3, and is not less
than 4.5 inches (114 mm) in length.
23. Section 1015.8 Window openings is hereby amended to read as follows:
1015.8 Window openings. Windows in Group R-2 and R-3 buildings including
dwelling units, where the bottom of the clear opening of an operable window opening
is located less than 24 inches (610 mm) above the finished floor and more than 72
inches (1829 mm) above the finished grade or other surface below on the exterior of
the building, shall comply with one of the following:
1. Operable windows where the top of the sill of the opening is located more than
75 feet (22 860 mm) above the finished grade or other surface below and that
are provided with window fall prevention devices that comply with ASTM
F2006.
2. Operable windows where the openings will not allow a 4-inch-diameter (102
mm) sphere to pass through the opening when the window is in its largest
opened position.
3. Operable windows where the openings are provided with window fall prevention
devices that comply with ASTM F2090.
4. Operable windows that are provided with window opening control devices that
comply with Section 1015.8.1.
24. A new Section 1015.9 Below grade openings is hereby added to read as follows:
1015.9 Below grade openings. All area wells, stair wells, window wells and light wells
attached to any building that are located less than 36 inches from the nearest intended
walking surface and deeper than 30 inches below the surrounding ground level shall
have guards or approved covers for fall protection.
25. Section 1031.2 Where required is hereby retained in its entirety with the following
amendments to Exceptions 1 and 5:
. . .
Exceptions:
1. Basements with a ceiling height of less than 72 inches (1828.8 mm) and do
not contain habitable space shall not be required to have emergency escape
and rescue openings.
. . .
5. Within individual dwelling and sleeping unites in Groups R-2 and R-3,
where the building is equipped throughout with an automatic sprinkler
system installed in accordance with Section 903.3.1.1 of the current
International Fire Code as adopted by the City, sleeping rooms in
- 14 -
basements shall not be required to have emergency escape and rescue
openings provided that the basement has one of the following:
5.1 One means of egress and one emergency escape and rescue opening.
5.2. Two means of egress.
26. A new Section 1031.3.4 Minimum height from floor is hereby added to read as
follows:
1031.3.4 Minimum height from floor. Emergency escape and rescue window
openings that are located more than 72 inches (1829 mm) above the finished grade
shall have a sill height of not less than 24 inches (609 mm) measured from the
finished interior side floor.
27. Section 1031.5.3 Drainage is hereby amended to add Exception 2 to read as follows:
1031.5.3 Drainage. Area wells shall be designed for proper drainage by connecting
to the building’s foundation drainage system required by Section 1805.
Exception:
1. A drainage system for area wells is not required where the foundation is on
well-drained soil or sand-gravel mixture soils in accordance with the United
Soil Classification System, Group I Soils, in accordance with Section
1803.5.1.
2. A drainage system is not required for new window wells on additions to
existing dwellings where no foundation drainage system exists.
28. Section 1102.1 Design is hereby amended to read as follows:
1102.1 Design. Buildings and facilities shall be designed and constructed to be
accessible in accordance with this code and the most recently published edition of ICC
A117.1 as referenced by the building official.
29. Section 1103.1 Where required is hereby amended to read as follows:
1103.1 Where required. Sites, buildings, structures, facilities, elements and spaces,
temporary or permanent, shall be accessible to individuals with disabilities.
When the Building Review Commission considers granting exceptions or variances
either to this chapter pursuant to Section 113 of this code or to C.R.S. § 9-5-103, it shall
require the applicant requesting the exception or variance to demonstrate that the
application of a particular standard or specification relating to access for persons with
disabilities would impose an extraordinary hardship on the subject property. For the
purposes of this Section, an extraordinary hardship shall mean a substantial and unusual
hardship that is the direct result of unique physical site conditions such as terrain,
topography or geology, or that is the direct result of other unique or special conditions
encountered on the subject property, but that are not typically encountered elsewhere
- 15 -
in the City. Constraints, complications or difficulties that may arise by complying with
this chapter and/or with the statutory standards for accessibility but that do not
constitute an extraordinary hardship shall not serve to justify the granting of an
exception or variance. The granting of a variance under this Section does not relieve
the applicant from its obligations under the Americans with Disabilities Act, or any
other applicable law or regulation that addresses accessibility.
30. Section 1107.2 Electrical vehicle charging stations is hereby amended to read as
follows:
1107.2 Electrical vehicle charging stations. Electrical vehicle charging stations
shall comply with Sections 1107.2.1 and 1107.2.2.
31. Section 1107.2.1 Number of accessible vehicle spaces is hereby amended to read as
follows:
Section 1107.2.1 Number of accessible vehicle spaces. Not less than 5 percent of
vehicle spaces on the site served by electrical vehicle charging systems, but not fewer
than one shall be accessible.
32. Section 1108.2 Design is hereby amended to read as follows:
1108.2 Design. Dwelling units and sleeping units that are required to be Accessible
units, Type A units and Type B units shall comply with the applicable portions of
Chapter 11 of ICC A117.1. Units required to be Type A units are permitted to be
designed and constructed as Accessible units. Units required to be Type B units are
permitted to be designed and constructed as Accessible units or as Type A units.
When any building or buildings, classified as Group R, Division 1 or Group R, Division
2 Occupancy, are constructed as a single building project (or any phase thereof) on any
one site, and such building project (or phase) contains one or more accessible dwelling
units as required by this chapter or Colorado law, said building project (or phase) shall
be constructed such that all required accessible dwelling units in such building project
(or phase) provide the same functional features as are provided in the non-accessible
units in such building project (or phase). Furthermore, all such functional features
except dwelling unit bedroom-types shall be provided in the same proportion as in the
non-accessible units. Not less than 50 percent of the required accessible dwelling units
shall be constructed with the distribution of accessible dwelling unit bedroom-types
being proportionally the same as the distribution of non-accessible dwelling unit
bedroom-types, provided that at least one of each dwelling unit bedroom-type
constructed in the building project (or phase) shall be an accessible dwelling unit.
For purposes of this Section the following definitions shall apply: Dwelling unit
bedroom-type shall mean the number of bedrooms within the dwelling unit. Functional
feature shall mean a closet, garage, carport, patio, deck, additional room (such as a
bedroom, bathroom, den, storeroom, laundry or similar room) or any other significant
- 16 -
feature built at the time of original construction that offers occupants improved
convenience or comfort. Aesthetic or decorative features such as colors, architectural
design elements, trim and finish materials, decorative heating appliances not providing
the primary comfort heat source, lighting fixture style, cabinet and hardware style,
plumbing fixture style, the type and location of windows and glazed lights, or any
similar miscellaneous features shall not be construed as functional features.
33. Table 1108.6.1.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS is
hereby amended to read as follows:
TABLE 1108.6.1.1
ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS
TOTAL
NUMBER OF
UNITS
PROVIDED
MINIMUM REQUIRED
NUMBER OF ACCESSIBLE
UNITS WITHOUT ROLL-IN
SHOWERS
MINIMUM
REQUIRED
NUMBER OF
ACCESSIBLE UNITS
WITH ROLL-IN
SHOWERSa
TOTAL NUMBER OF
REQUIRED
ACCESSIBLE UNITS
1 to 25 1 0 1
26 to 50 1 1 2
51 to 75 2 2 4
76 to 100 3 2 5
101 to 150 5 2 7
151 to 200 6 2 8
201 to 300 7 3 10
301 to 400 8 4 12
401 to 500 9 4 13
501 to 1000 2% of total 1% of total 3% of total
Over 1000 20, plus 1 for each 100, or
fraction thereof, over 1000
10, plus 1 for each 100,
or fraction thereof, over
1000
30, plus 1 for each 100,
or fraction thereof, over
1000
aRequired roll-in showers shall be a minimum of 36 inches (91 cm) by 60 inches (152 cm) interior dimension.
34. A new Section 1108.6.2.1.1 R-2 accessible roll-in showers is added to read as follows:
1108.6.2.1.1 R-2 accessible roll-in showers. All roll-in showers provided in R-2
accessible, Type A, or Type B units, shall provide a minimum interior dimension of 36
inches (91 cm) by 60 inches (152 cm).
35. A new Section 1403.9.1 Vinyl siding quality control is hereby added to read as
follows:
1403.9.1 Vinyl siding quality control. Vinyl siding shall be certified and labeled as
conforming to the requirements of ASTM D 3679 by an approved quality control
agency.
36. A new Section 1403.9.2 Vinyl siding on new buildings is hereby added to read as
follows:
- 17 -
1403.9.2 Vinyl siding on new buildings. Vinyl sidings on new buildings shall be
installed over one-hour fire-rated assemblies listed for exterior fire exposure, in both
the vertical and horizontal plane.
37. A new Section 1403.12.1 Polypropylene siding on new buildings is hereby added to
read as follows:
1403.12.1 Polypropylene siding on new buildings. Polypropylene siding on new
buildings shall be installed over one-hour fire-rated assemblies listed for exterior fire
exposure, in both the vertical and horizontal plane.
38. Section 1502.1 General is hereby amended to read as follows:
1502.1 General. All buildings shall have a controlled method of water disposal from
roofs that will collect and discharge roof drainage to the ground surface at least 5 feet
(1524 mm) from foundation walls or to an approved drainage system. Design and
installation of roof drainage systems shall comply with this Section, Section 1611 of
this code and Chapter 11 of the International Plumbing Code.
39. A new Section 1504.8.1 Impact resistance of asphalt shingles is added to read as
follows:
1504.8.1 Impact resistance of asphalt shingles. Asphalt shingles shall be Class 4
impact resistant, comply with UL 2218 and installed in accordance with the
manufacturer’s installation instructions.
Exceptions:
1. When existing asphalt shingles are less than Class 4 impact resistant, and the owner
wishes to replace the existing asphalt shingles with tiles of a similar color or tile, and
there are no Class 4 impact resistance shingles available that are similar color or style
of the existing asphalt shingles, the building official may approve alternate materials
that are less than Class 4 impact resistant; however, the building official will impose
the highest class of impact resistance that are available that match the color or style of
the existing asphalt shingles. If no impact resistant materials are available, the building
official may approve non-impact resistant materials if the alternate materials meet all
other applicable requirements of this Code.
2. When the owner is repairing or adding to existing asphalt singles that are less than
Class 4 impact resistant, the owner may use the same or similar materials as the current
existing asphalt shingles, even if that same or similar material is not impact resistant.
40. Section 1505.1 General is hereby deleted in its entirety and replaced with the
following:
- 18 -
1505.1 New Construction. The roof assemblies classification on any new structure
regulated by this code shall be Class A.
Exceptions:
1. Noncombustible roof coverings as defined in Section 1507.3, 1507.4,
1507.5 may be applied in accordance with the manufacturer's specifications
in place of a fire-retardant roofing assembly.
2. Any Class B or Class C roof coverings may be applied on any new
construction that is added to an existing building classified as a Group R,
Division 3 Occupancy, provided that the roof extremities of such existing
building and new construction are located a minimum distance of 5 feet
from the nearest adjacent property line and are a minimum distance of 10
feet from any other building.
3. Skylights and sloped glazing that comply with Chapter 24 or Section 2610
of this code.
41. Table 1505.1 MINIMUM ROOF COVERING CLASSIFICATIONS FOR TYPES
OF CONSTRUCTION is hereby deleted in its entirety.
42. Section 1507.2.1 Deck requirements is hereby amended to read as follows:
1507.2.1 Deck Requirements. Asphalt shingles shall be fastened to solidly sheathed
decks. Gaps in solidly-sheathed or plank decking shall not exceed 1/8 inch.
43. Section 1512.1 General is hereby amended to read as follows:
1512.1 General. Materials and methods of application used for recovering or replacing
an existing roof covering shall comply with the requirements of Chapter 15. No portion
of an existing nonrated roof covering may be permanently replaced or covered with
more than one square of nonrated roof covering. Any existing roof covering system
may be replaced with a roof covering of the same materials and classification, provided
that the replacement roof covering has a minimum rating of Class C.
Exceptions:
1. Roof replacement or roof recover of existing low-slope roof coverings shall
not be required to meet the minimum design slope requirement of 1/4 unit
vertical in 12 units horizontal (2-percent slope) in Section 1507 for roofs
that provide positive roof drainage.
2. Recovering or replacing an existing roof covering shall not be required to
meet the requirement for secondary (emergency overflow) drains or
scuppers in Section 1502.2 for roofs that provide for positive roof drainage.
For the purposes of this exception, existing secondary drainage or scupper
systems required in accordance with this code shall not be removed unless
- 19 -
they are replaced by secondary drains or scuppers designed and installed in
accordance with Section 1502.2.
44. Section 1608.2 Ground snow loads is hereby deleted in its entirety and replaced with
the following:
1608.2 Ground Snow Loads. The design ground snow load (Pg) shall be 35 psf for
the City of Fort Collins per the Colorado Design Snow Loads, published by the
Structural Engineers Association of Colorado (dated April 2016). The design roof snow
load values shall be determined from Chapter 7, ASCE 7-16, including all applicable
factors, and loading and drifting considerations. In no case shall the final design roof
snow load be less than a uniformly distributed load of 30 psf.
45. Section 1609.3 Basic design wind speed is hereby deleted in its entirety and replaced
with the following:
1609.3 Basic design wind speed. The basic design wind speed, V, in mph, for the
determination of the wind loads shall be 140 miles per hour (Ultimate) for Risk
Category II, 130 miles per hour (Ultimate) for Risk Category I, 150 miles per hour
(Ultimate) for Risk Category III & IV, or shall comply with the Colorado Front Range
Gust Map – ASCE 7-10 Compatible, published by the Structural Engineers Association
of Colorado (dated November 18, 2013).
46. A new Section 1804.4.1 Final Grading is hereby added to read as follows:
1804.4.1 Final Grading. Final grading adjacent to the foundation and above utility
trenches shall be compacted sufficiently and in such a manner that it is not undermined
or subject to significant settlement or displacement due to improper placement of
backfill.
47. A new Section 1811 RADON-RESISTANT CONSTRUCTION is hereby added to
read as follows:
1811 RADON-RESISTANT CONSTRUCTION
1811.1 General. New R-2, R-3, R-4 Occupancies and new I-1 and I-2 nursing homes
shall provide radon reduction systems complying with the 2021 International
Residential Code, Appendix AF, as amended by the City of Fort Collins.
48. Section 2406.4.7 Glazing adjacent to bottom stairway landing is hereby amended
to read as follows:
2406.4.7 Glazing adjacent to stair landings. Glazing adjacent to the stair landings
where the glazing is less than 36 inches (914 mm) above the landing and within 60-
inches (1524 mm) horizontally from the top or bottom tread shall be considered a
hazardous location.
- 20 -
49. A new Section 2902.1.4 Touch-free toilet facilities is hereby added to read as follows:
2902.1.4 Touch-free toilet facilities. Toilet facilities installed for occupancies
associated with food preparation or food service to the public shall be provided with:
1. Automatic touch-free water control valves on lavatories.
2. Automatic touch-free paper towel dispensers.
3. Toilet facilities exit doors that allow exiting without requiring touching by hand
of any door hardware such as knobs, levers, sliding bolts, latches and similar
devices.
Exception: Toilet facilities designed as a single occupant use may be provided
with exit door locking hardware to afford privacy, doors may swing inward or
outward.
50. Section 2902.2 Separate facilities is hereby deleted in its entirety and replaced with
the following:
[P] 2902.2 Separate facilities. Where plumbing fixtures are required, separate
facilities shall be provided for each sex.
Exceptions:
1. Separate facilities shall not be required for dwelling units and sleeping units.
2. Separate facilities shall not be required in structures or tenant spaces with a
total occupant load, including both employees and customers, of 15 or fewer.
3. Separate facilities shall not be required in mercantile occupancies in which
the maximum occupant load is 100 or fewer.
4. Separate facilities shall not be required in business occupancies in which the
maximum occupant load is 25 or fewer.
5. Separate facilities shall not be required to be designated by sex where single-
user toilets rooms are provided in accordance with Section 2902.1.2.
6. Separate facilities shall not be required where rooms having both water
closets and lavatory fixtures are designed for use by both sexes and privacy
for water closets are installed in accordance with Section 405.3.4 of the
International Plumbing Code. Urinals shall be located in an area visually
separated from the remainder of the facility or each urinal that is provided
shall be located in a stall.
2902.2 Required restroom facilities. Restroom fixtures shall be provided in quantities
per Table 2902.1, which shall be achieved by either gender-neutral single-user
restrooms or by multi-user (multi-fixture) restrooms for each sex. Gender-neutral
multi-user restrooms are allowed only where water closets and showers are each
provided in compartments with walls or partitions and a door enclosing the fixtures to
ensure privacy. Urinals must be located in an area visually separated from the
remainder of the facility or each urinal must be located in a stall. The number of fixtures
- 21 -
shall be calculated based on the average of the number of male/female fixtures in table
2902.1.
Exceptions:
1. For mercantile occupancies in which the maximum occupant load is 100 or fewer,
one gender-neutral single-user restroom is allowed.
2. For buildings in which the maximum occupant load is 25 or fewer, one gender-
neutral single-user restroom is allowed.
51. A new CHAPTER 36 SUSTAINABLE BUILDING CONSTRUCTION
PRACTICES is hereby added to read as follows:
CHAPTER 36 SUSTAINABLE BUILDING CONSTRUCTION PRACTICES
Section 3601 General
3601.1 Scope. The provisions of this chapter shall govern sustainable building
construction practices for new construction and additions and remodels over 5,000
square feet that require a building permit, unless otherwise noted.
Section 3602 Resource Efficiency
3602.1 Construction waste management. For remodels and additions over 2,500
square feet, and for all new buildings, a construction waste management plan
acceptable to the building official is required at the time of application for a building
permit. The construction waste management plan shall be implemented and
conspicuously posted on the construction site. All concrete, asphalt, masonry, wood,
metals and cardboard shall be recycled. All mixed construction and demolition
materials (as defined in § 12-16 of the City Code) shall be delivered to any facility
identified in and disposed of in accordance with § 12-22(c) of the City Code.
Compliance shall be certified by inspection and documentation and signed final
construction waste management plans. Substantive changes to the plan are subject to
prior approval by the building official. All roofing permits are required to submit a final
waste management plan and documentation.
3602.1.1 Building demolitions. Buildings or portions of buildings that are removed
shall be processed in such a way as to safely remove all asbestos and lead paint
contaminants. For all demolitions, excluding non-structural demolitions under 1000
square feet, a demolition waste management plan acceptable to the building official
is required at the time of application for a demolition permit. All metals, asphalt,
concrete and masonry that are free of asbestos and lead paint shall be recycled, and
where possible, all remaining materials, such as doors, windows, cabinets, fixtures,
and wood, shall be recycled. All mixed construction and demolition materials (as
defined in § 12-16 of the City Code) shall be delivered to any facility identified in
and disposed of in accordance with § 12-22(c) of the City Code. Compliance shall
- 22 -
be certified by inspection, documentation, and signed final demolition waste
management plans. Substantive changes to the plan are subject to prior approval
by the building official.
3602.1.2 Recycle chutes. New buildings provided with trash chutes or existing
buildings renovated that add a new trash chute shall provide an additional
equivalent chute adjacent to the trash chute for the purpose of recycling. Separate
bins shall be provided in the termination room to prevent recycled items from
entering the trash bin. Chutes must be appropriately labeled “Landfill” and
“Recycle.”
3603 Indoor Environmental Quality (IEQ)
3603.1 Indoor Air Quality (IAQ)
3603.1.1 Heating, Ventilating, and Air Conditioning Design. Prior to and during
construction, reasonable efforts shall be made to minimize the release of
particulates and accumulation of debris, and the specific requirements of this
Section shall apply.
3603.1.2 Air handling system access. The arrangement and location of air
handling system components including, but not limited to, air handler units, fans,
coils and condensate pans, shall allow access for cleaning and repair of the air
handling surfaces of such components. Piping, conduits, and other building
components shall not be located so as to obstruct the required access.
3603.1.3 Durability of air handling surfaces. Surfaces exposed to airflow
within air handling systems shall be constructed of materials that are resistant
to deterioration and will not break away, crack, peel, flake off, or show evidence
of delamination or continued erosion when tested in accordance with the
erosion test in UL 181.
3603.1.4 Airstream surfaces. Materials exposed to airflow within ducts, within
air plenums, or on top of suspended ceilings, shall not break away, crack, peel, flake
off, or show evidence of delamination or continued erosion when tested in
accordance with the erosion test in UL 181.
3603.1.5 New building and first time completed tenant finish spaces pollutant
flush-out. After all interior finishes are installed, the building or space shall be
flushed out by ventilating at a minimum rate of 0.30 cfm per ft2 of outside air or the
design outdoor airflow rate determined from the International Mechanical Code,
whichever is greater, for at least 14 days while maintaining an internal temperature
of at least 60°F, and relative humidity not higher than 60 percent. Occupancy shall
be permitted to start 1 day after start of the flush-out, provided that flush-out
continues for the full 14 days. The building or space shall not be “baked out” by
increasing the temperature of the space above the occupied set point.
- 23 -
Exception: All residential buildings.
3603.2 Acoustical control. Minimum requirements for exterior-to-interior sound
transmission, interior sound transmission, and background sound levels in new
construction and additions, except as noted hereunder, shall be provided as specified
herein.
3603.2.1 Sound transmission. New buildings shall comply with the following
sound transmission requirements:
3603.2.2 Exterior sound transmission. Where a Group A1, A3, E and I occupancy
building, a Group B occupancy building used for educational purposes, or a Group
R occupancy building is constructed at a location listed herein, the wall assemblies
making up the building thermal envelope or professional analysis of effected walls
shall have a composite sound transmission class (STC) rating of 39 or greater in the
following locations:
1. Within 500 feet (152 m) of a multi-lane highway designed for high-speed
travel by large numbers of vehicles, and having no traffic lights, stop signs,
or other regulations requiring vehicles to stop; fire stations; heavy industrial
or manufacturing areas or facilities; commercial storage facilities with
back-up alarms; outdoor music amphitheaters; or sports arena or stadium;
2. Within 250 feet (76 m) of a roadway containing 4 or more traffic lanes; or
3. Within 1,000 feet (305 m) of an active railway.
3603.2.3 Interior sound transmission. Interior wall and floor/ceiling assemblies,
separating interior rooms and spaces shall be designed in accordance with the
following requirements:
1. Wall and floor-ceiling assemblies separating adjacent tenant spaces, tenant
spaces and public places, hotel rooms, motel rooms, patient rooms in
nursing homes and hospitals, and adjoining classrooms shall have a
composite STC rating of 50 or greater.
2. Wall and floor-ceiling assemblies separating classrooms from rest rooms
and showers shall have a composite STC rating of 53 or greater.
3. Wall and floor-ceiling assemblies separating classrooms from music rooms,
mechanical rooms, cafeterias, gymnasiums, and indoor swimming pools
shall have a composite STC rating of 60 or greater.
Exception: Residential Group R occupancies addressed in Section 1206 of this
code.
- 24 -
Section 3604 Electrical vehicle charging.
3604.1 Scope: The provisions of this Section shall control the design and construction
for Electric Vehicle Charging.
3604.2 Definitions applicable to this Chapter:
Affordable Housing: Residential occupancies that meet the criteria established in
the Land Use Code Section 5.1.2 as affordable housing.
Electric Vehicle (EV): A vehicle registered for on-road use, primarily powered
by an electric motor that draws current from a rechargeable storage source that is
charged by being plugged into an electrical current source.
Electric Vehicle Supply Equipment (EVSE). The electrical conductors and
associated equipment external to the electric vehicle that provide a connection
between the premises wiring and the electric vehicle to provide electric vehicle
charging.
Electric Vehicle Fast Charger. Electric vehicle supply equipment with a minimum
power output of 20 kW.
Electric Vehicle Load Management System. A system designed to allocate
charging capacity among multiple electric vehicle supply equipment that complies
with the current National Electric Codeat a minimum of 8 amps per charger.
Electric Vehicle Capable Space. A designated parking space that is provided with
a minimum conduit of 1” sized for a continuous 40-amp, 208/240-Volt dedicated
branch circuit from a building electrical panelboard to the parking space and with
sufficient physical space in the same building electrical panelboard to
accommodate a 40-amp, dual-pole circuit breaker. A designated parking space or
spaces that are provided with conduit from the parking space to a building electrical
room with sufficient physical space in the electrical room to accommodate the
future installation of type 2 charging equipment (EVSE) to those parking spaces.
Electric Vehicle Ready Space. A parking space that is provided with one
continuous 40-amp, 208/240-Volt dedicated branch circuit for electric vehicle
supply equipment that is terminated at a receptacle or electric vehicle supply
equipment within the parking space. If an Electric Vehicle Load Management
System is specified, then the electrical requirements may be adjusted per the current
National Electric Code.
- 25 -
Electric Vehicle Supply Equipment Installed Space. A parking space or spaces
with minimum of level 2 electric vehicle supply equipment capable of supplying a
minimum 40-amp dedicated branch circuit rated at 240 Volt from a building
electrical panelboard. If an Electric Vehicle Load Management System is specified,
then the electrical requirements may be adjusted per the current National Electric
Code.
3604.3 Electric Vehicle Supply Equipment: All electric vehicle supply
equipment shall be sized and installed in accordance with article 625 of the
currently adopted National Electrical Code.
3604.4 Accessibility: All Electric Vehicle Ready and Electric vehicle supply
equipment installed spaces shall meet all requirements in Chapter 11 of this code.
The total amount of required accessible parking spaces shall be removed from the
total number of available spaces when calculating the required percentage of spaces
for EV.
3604.5 New buildings. All new buildings or buildings undergoing a primary or partial
change of occupancy or use in which more than 50% of the total building area is
changing shall provide electrical vehicle parking spaces based on the minimum number
of parking spaces as defined by the standards in the Land Use Code (LUC). A parking
schedule shall be shown on the submitted plans that lists the required parking spaces
and the provided EV spaces in accordance with the TABLE 3604.5.
Exceptions:
1. Type 2 Chargers can be reduced by up to five, provided that the building
includes not less than one parking space equipped with an electric vehicle
fast charger and not less than one electric vehicle ready space.
2. Parking spaces associated with structures and tenant spaces intended for
quick transactions, including takeout, pickup, and drop-off shall be exempt.
3. All new and existing developments, where the EV-capacity requirements
would require an upgrade of an existing transformer, are exempt.
TABLE 3604.5
City of Fort Collins
Occupancy
Classification for EV
Charging Infrastructure
EVSE -
installed EV - Ready EV – capable
Tier 1
Residential 10% 20% 40%
- 26 -
Affordable housing N/A N/A 10%
Tier 2
Mercantile 5% 15% 20%
Assembly 5% 15% 20%
Institutional 5% 15% 20%
Business 5% 15% 20%
Educational 5% 15% 20%
Factory 5% 15% 20%
Tier 3
High hazard 1% 5% 15%
Storage 1% 5% 15%
Utility and misc. group 1% 5% 15%
3604.6 Existing buildings. Existing buildings that provide on-site parking and undergo
a renovation or alteration in which the scope of work is more than 50% of the total
building area shall provide at least one EVSE-installed space.
52. APPENDIX C GROUP U--AGRICULTURAL BUILDINGS is adopted in its
entirety.
53. APPENDIX E SUPPLEMENTARY ACCESSIBILITY REQUIREMENTS is
adopted in its entirety.
54. APPENDIX I PATIO COVERS is adopted in its entirety.
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
- 27 -
_______________________________
City Clerk
- 28 -
Passed and adopted on final reading on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_______________________________
City Clerk
- 1 -
ORDINANCE NO. 022, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 2 OF THE CODE
OF THE CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE 2018
INTERNATIONAL ENERGY CONSERVATION CODE AND ADOPTING THE
2021 INTERNATIONAL ENERGY CONSERVATION CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes ought to be adopted and that any counterpart International
codes previously adopted should be repealed, both to align the publication years of the codes and
also because the 2021 publications contain improvements in construction code regulation; and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its citizens that the 2021 International Energy Conservation
Code be adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
- 2 -
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Energy
Conservation Code (“IECC”) and hereby adopts the 2021 IECC as amended by this Ordinance.
Section 3. That Section 5-26(b) of the Code of the City of Fort Collins is hereby
deleted in its entirety and all subsequent subparagraphs re-lettered accordingly.
Section 4. That Section 5-26(c) of the Code of the City of Fort Collins is hereby
amended to read as follows:
(b) Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-
16-202 and Article II, Section 7 of the Charter, the City Council has adopted the 2021
International Energy Conservation Code published by the International Code Council, as
amended by the City, which shall have the same force and effect as though set forth in full
herein and which shall apply exclusively to the design and construction of all buildings that
are classified as residential buildings not more than three (3) stories above grade and their
systems; new portions of such existing buildings and their systems; and new systems and
equipment in such existing buildings, exclusive of detached one- and two-family dwellings,
multiple single-family dwellings (townhouses), for the purpose of establishing minimum
requirements for minimum energy efficiency. As provided in the 2021 International
Energy Conservation Code, Appendices are not adopted except as expressly set forth in §
5-31.
Section 5. That Section 5-31 of the Code of the City of Fort Collins is hereby repealed
in its entirety and reenacted to read as follows:
Sec. 5-31. Amendments and deletions to the 2021 International Energy Conservation
Code.
The 2021 INTERNATIONAL ENERGY CONSERVATION CODE adopted in § 5-26(c) is
hereby amended in the following respects:
1. Section C101.1 Title is hereby retained in its entirety with the following amendments:
C101.1 Title. This code shall be known as the International Energy Conservation Code
of the City of Fort Collins, and shall be cited as such. It is referred to herein as “this
code.”
2. A new Section C101.4.2 Energy assessment is hereby added to read as follows:
- 3 -
C101.4.2 Energy assessment. Prior to any alterations, projects shall undergo a City
of Fort Collins Utilities Facility Energy Assessment.
Exceptions: Facility energy assessments are not required in the following cases.
1. Buildings for which the first Certificate of Occupancy was issued after
August 2017.
2. First-time interior finishes.
3. A building that has undergone an energy assessment within the previous
three years.
4. Alterations to the HVAC, lighting, power, exterior walls systems, and
roofing systems or replacement of such with a construction valuation of less
than $50,000.
5. Residential buildings.
3. A new Section C103.7 Permits is hereby added to read as follows:
C103.7 Permits. Procedures related to permits, required inspections, payment of fees
and obtaining required approvals shall be as set forth in Chapter 1 of the adopted
International Building Code.
4. SECTION C104 FEES is hereby deleted in its entirety and replaced with the
following:
C104.1 Fees. All items relating to fees shall be as specified in Section 109 of the
adopted International Building Code, entitled “Fees.”
5. SECTION C110 BOARD OF APPEALS is hereby deleted in its entirety and replaced
with the following:
SECTION C110
MEANS OF APPEALS
C110.1 Means of appeals. Appeals of decisions, determinations and interpretations of
this code shall be made pursuant to the applicable provisions of Section 113 of the
adopted International Building Code, entitled “MEANS OF APPEALS.”
6. A new SECTION C111 VIOLATIONS is hereby added to read as follows:
SECTION C111 VIOLATIONS.
C111.1 Violations. Violations of this code shall be made pursuant to the applicable
provisions of Section 114 of the adopted International Building Code as amended.
7. SECTION C202 GENERAL DEFINITIONS is hereby amended to modify, or add,
in alphabetical order, the following definitions:
ALL-ELECTRIC BUILDING. A building that has no natural gas or propane
plumbing installed within the building, and that uses electricity as the sole source of
- 4 -
energy for its space heating and cooling, water heating (including pools and spas),
cooking appliances, and clothes drying appliances. All-electric buildings may include
solar thermal water and pool heating.
CONTINUOUS AIR BARRIER. The combination of interconnected materials,
assemblies, and flexible sealed joints and components of the building thermal envelope
that provides air tightness to a specified permeability.
ELECTRIC HEAT. An indoor environmental primary heat source that is electric. A
ground-source electric heat pump or a cold climate heat pump specifically designed to
heat at the Winter Outdoor, Design Dry-Bulb temp for Climate Zone 5b as determined
by the DESIGN CRITERIA within this code. The heat pump system shall not be gas
or propane fuel fired. Electric resistance strip heat shall serve only as emergency back-
up heat or supplemental heat at outdoor temperatures below 15oF as necessary.
MIXED-FUEL BUILDING. A building that uses natural gas or propane as fuel for
space heating and cooling, water heating (including pools and spas), cooking
appliances or clothes drying appliances, or is plumbed for such equipment.
8. A new Section C301.5 Exterior and interior local design parameters is hereby
added to read as follows:
Section C301.5 Exterior and Interior Local Design Parameters. The following
thermal design parameters shall be used for mechanical load calculations and designs.
Exterior and Interior Local Design Parameters.
Winter Outdoor, Design Dry-bulb (oF) = 6
Winter Indoor, Design Dry-bulb (oF) = 72
Summer, Outdoor Design Dry-bulb (oF) = 91
Summer, Indoor Design Dry-bulb (oF) = 75
Summer, Outdoor Design Wet-bulb (oF) = 62
Summer, Indoor Design Wet-bulb (oF) = 62
Degree Days heating = 6148
Degree days cooling = 757
Fort Collins is in Climate Zone 5B.
9. A new Section C401.1.1 Building Electrification is hereby added to read as follows:
C401.1.1 Building electrification. All newly constructed buildings shall be
constructed as an all-electric building or a mixed-fuel building that is pre-wired for
future electric space heating, water heating, cooking and clothes drying equipment.
10. Section C401.2.2 ASHRAE 90.1 is hereby amended to read as follows:
C401.2.2 ASHRAE 90.1. Commercial buildings shall comply with the requirements
of ANSI/ASHRAE/IESNA 90.1, Section C401.1.1 Building Electrification, Section
- 5 -
C402.2.4 Slabs-on-grade, Section C402.5 Air leakage-thermal envelope, and
APPENDIX CB SOLAR READY ZONE-COMMERCIAL.
11. Section C402.1.2 Equipment buildings is hereby retained in its entirety, except Item
#3 is amended to read as follows:
. . .
3. Have a heating system capacity not greater than (17,000 Btu/h) (5 kW) and a
heating thermostat setpoint that is restricted to not more than 50oF (10oC) and that
have permanent signage installed at the thermostat as instruction to the thermostat
setpoint limitation.
. . .
12. TABLE C402.1.3 OPAQUE THERMAL ENVELOPE INSULATION
COMPONENT MINIMUM REQUIREMENTS, R-VALUE METHOD is hereby
deleted in its entirety and replaced with the following Table:
TABLE C402.1.3
OPAQUE THERMAL ENVELOPE INSULATION COMPONENT MINIMUM
REQUIREMENTS, R-VALUE METHODa
CLIMATE ZONE 5 All other Group R
Roofs
Insulation entirely above
roof deck R-30ci R-30ci
Metal buildingsb R-19+R-11 LS R-19+R-11 LS
Attic and other R-49 R-49
Walls, above grade
Massf R13ci R-13ci
Metal building R-13+R-15ci R-13+R-15ci
Metal framed R-13+R-10ci R-13+R-10ci
Wood framed and other R-15+R-7.5ci or R-20+5cii R-15+R-7.5ci or R-20+5cii
Walls, below grade
Below-grade walld R-10ci R-10ci
Floors
Masse R-14.6ci R-16.7ci
Floor - steel joist R-30+7.5ci R-30+7.5ci
Wood joist/framing R-38 R-38
Slab-on-grade floors
Unheated slabsh R-15 for 24” below R-20ci for 24” below
Heated slabsg,h R-15 for 36” below+R-5 full slab R-15 for 36” below+R-5 full slab
Opaque doors
- 6 -
Opaque non-swinging doors R-4.75 R-4.75
For SI: 1 inch = 25.4 mm, 1 pound per square foot = 4.88 kg/m2, 1 pound per cubic foot = 16 kg/m3.
ci = Continuous Insulation, NR = No Requirement, LS = Liner System.
a. Assembly descriptions can be found in ANSI/ASHRAE/IESNA 90.1 Appendix A.
b. Where using R-value compliance method, a thermal spacer block shall be provided, otherwise use the U-factor compliance method in
Table C402.1.4.
c. R-5.7ci is allowed to be substituted with concrete block walls complying with ASTM C90, ungrouted or partially grouted at 32 inches
or less on center vertically and 48 inches or less on center horizontally, with ungrouted cores filled with materials having a maximum
thermal conductivity of 0.44 Btu-in/h-f2 °F.
d. Where heated slabs are below grade, below-grade walls shall comply with the exterior insulation requirements for heated slabs.
e. “Mass floors” shall be in accordance with Section C402.2.3.
f. “Mass walls” shall be in accordance with Section C402.2.2.
g. The first value is for perimeter insulation and the second value is for full, under-slab insulation. Perimeter insulation is not required to
extend below the bottom of the slab.
h. Vertical insulation located below grade shall be extended the distance provided in the table or to top of footing.
i. Class 1 vapor retarders shall not be installed on the interior of framed walls where exterior ci value is less than R-7.5.
13. TABLE C402.1.4 OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM
REQUIREMENTS, U-FACTOR METHODa,b is hereby deleted in its entirety and
replaced with the following Table:
TABLE C402.1.4
OPAQUE THERMAL ENVELOPE ASSEMBLY MAXIMUM REQUIREMENTS, U-FACTOR
METHODa,b
CLIMATE ZONE 5 All other Group R
Roofs
Insulation entirely above
roof deck U-0.032 U-0.032
Metal buildings U-0.035 U-0.035
Attic and other U-0.021 U-0.021
Walls, above grade
Massg U-0.68 U-0.068
Metal building U-0.49 U-0.49
Metal framed U-0.052 U-0.052
Wood framed and otherk U-0.046 U-0.046
Walls, below grade
Below-grade wallc U-0.092 U-0.092
Floors
Massd U-0.057 U-0.051
Floor - steel joist U-0.029 U-0.029
Wood joist/framing U-0.027 U-0.027
Slab-on-grade floors
Unheated slabsj F-0.52 F-0.51
Heated slabsf,j F-0.62 F-0.62
Opaque doors
Non-swinging door U-0.31 U-0.31
Swinging doorh U-0.37 U-0.37
Garage door <14% glazingi U-0.31 U-0.31
For SI: 1 pound per square foot = 4.88 kg/m2, 1 pound per cubic foot = 16 kg/m3.
ci = Continuous Insulation, NR = No Requirement, LS = Liner System.
- 7 -
a. Where assembly U-factors, C-factors and F-factors are established in ANSI/ASHRAE/IESNA 90.1 Appendix A, such opaque
assemblies shall be a compliance alternative where those values meet the criteria of this table, and provided that the construction,
excluding the cladding system on walls, complies with the appropriate construction details from ANSI/ASHRAE/ISNEA 90.1
Appendix A.
b. Where U-factors have been established by testing in accordance with ASTM C1363, such opaque assemblies shall be a compliance
alternative where those values meet the criteria of this table. The R-value of continuous insulation shall be permitted to be added to or
subtracted from the original tested design.
c. Where heated slabs are below grade, below-grade walls shall comply with the U-factor requirements for above-grade mass walls.
d. “Mass floors” shall be in accordance with Section C402.2.3.
e. These C-, F- and U-factors are based on assemblies that are not required to contain insulation.
f. The first value is for perimeter insulation and the second value is for full, under-slab insulation.
g. “Mass walls” shall be in accordance with Section C402.2.2.
h. Swinging door U-factors shall be determined in accordance with NFRC-100.
i. Garage doors having a single row of fenestration shall have an assembly U-factor less than or equal to 0.44 in Climate Zones 0
through 6 and less than or equal to 0.36 in Climate Zones 7 and 8, provided that the fenestration area is not less than 14 percent and
not more than 25 percent of the total door area.
j. Vertical insulation located below grade shall be extended the distance provided in the table or to top of footing.
k. Class 1 vapor retarders shall not be installed on the interior of framed walls where exterior ci value is less than R-7.5.
14. Section C402.2 Specific building thermal envelope insulation requirements is
hereby amended to read as follows:
C402.2 Specific building thermal envelope insulation requirements. Insulation in
building thermal envelope opaque assemblies shall comply with Sections C402.2.1
through C402.2.7 and Table C402.1.3. All insulation shall be installed to meet
Residential Energy Services Network (RESNET) Grade I standard.
15. Section C402.5 Air leakage-thermal envelope is hereby amended to read as follows:
C402.5 Air leakage—thermal envelope. The building thermal envelope shall comply
with Sections C402.5.1 through Section C402.5.11.1, and the building thermal
envelope shall be tested in accordance with Section C402.5.2 or C402.5.3.
16. Section C402.5.1 Air barriers is hereby amended to read as follows:
Section C402.5.1 Air barriers. A continuous air barrier shall be provided throughout
the building thermal envelope. The continuous air barriers shall be located on the
inside or outside of the building thermal envelope, located within the assemblies
composing the building thermal envelope, or any combination thereof. The air barrier
boundary limits and size of the surface area (floor, wall, and ceiling or roof) of the
building air barrier, and of the zone or zones to be tested for maximum building air
infiltration and exfiltration, shall be clearly identified on the approved construction
drawings. All air barrier components of each building thermal envelope assembly
shall be clearly identified on construction documents and the joints, interconnections,
and penetrations of the air barrier components shall be detailed and shall comply with
Sections C402.5.1through C402.5.9.
Exception: Air barriers are not required in buildings located in Climate Zone 2B.
17. Section C402.5.1.5 Building envelope performance verification is hereby amended
to read as follows:
- 8 -
Section C402.5.1.5 Building envelope performance verification. The installation of
the continuous air barrier shall be verified by the code official and an approved air
leakage testing agency in accordance with the following:
1. A review of the construction documents and other supporting data shall be
conducted to assess compliance with the requirements in Section C402.5.1.
2. Inspection of continuous air barrier components and assemblies shall be
conducted during construction while the air barrier is still accessible for
inspection and repair to verify compliance with the requirements of Sections
C402.5.1.3 and C402.5.1.4.
3. An air barrier and air sealing inspection report shall be provided for
inspections completed by the approved air leakage testing agency. The air
barrier and air sealing inspection report shall be provided to the building owner
or owner’s authorized agent and the code official at the time of framing and
insulation inspection. The report shall identify deficiencies found during the
review of the construction documents and inspection and details of corrective
measures taken.
18. Section C402.5.2 Dwelling and sleeping unit enclosure testing is hereby deleted in
its entirety and replaced with the following:
C402.5.2 Dwelling and sleeping unit enclosure testing. The building thermal
envelope shall be tested in accordance with ASTM E779, ANSI/RESNET/ICC 380,
ASTM E1827 and City of Fort Collins Building Code Protocol for New Multifamily
Building Air Tightness Testing. Documentation of the testing results shall be submitted
to the building official prior to approval. If the building or dwelling unit fails air leakage
testing, the testing agency is required to perform a diagnostic evaluation in accordance
with ASTM E1186. The testing agency can use additional methods to discover leaks.
Repairs based on these diagnostics and retesting is required prior to submitting results
to the building official. Where compliance is based on such testing, the building also
shall comply with Sections C402.5.6, C402.5.7 and C402.5.8. The air barrier shall
comply with Sections C402.5.1.1, and C402.5.1.2. The measured air leakage shall not
exceed 0.30 cfm/ft2 (1.5 L/s m2) of the testing unit enclosure area at a pressure
differential of 0.2 inch water gauge (50 Pa). Units shall be tested separately with an
unguarded blower door test as follows:
1. Where buildings have fewer than eight testing units, each testing unit shall be
tested.
2. For buildings with eight or more testing units, 20 percent of the testing units in
the building shall be tested, including at least one of each unit type and
approximately an equal number of units on each floor level. For each tested unit
that exceeds the maximum air leakage rate, corrections to the unit must be made
and the unit re-tested until it meets the required air leakage, and an additional
two units of this type in the same building shall be tested and meet the required
air leakage.
- 9 -
19. Section C402.5.3 Building thermal envelope testing is hereby deleted in its entirety
and replaced with the following:
C402.5.3 Building thermal envelope testing. The building thermal envelope shall be
tested in accordance with ASTM E779, ANSI/RESNET/ICC 380, ASTM E3158 or
ASTM E1827 or in accordance with the most current version of the City of Fort Collins
Building Air Leakage Test Protocol for commercial buildings. Documentation of the
testing results shall be submitted to the building official prior to approval. If the
building fails air leakage testing, the testing agency is required to perform a diagnostic
evaluation in accordance with ASTM E1186. The testing agency can use additional
methods to discover leaks. Repairs based on these diagnostics and retesting is required
prior to submitting results to the building official. Where compliance is based on such
testing, the building shall also comply with Sections C402.5.7, C402.5.8 and C402.5.8.
The air barrier shall comply with Sections C402.5.1.1, and C402.5.1.2. The measured
air leakage shall not exceed 0.25 cfm/ft2 (2.0 L/s × m2) of the building thermal
envelope area at a pressure differential of 0.3 inch water gauge (75 Pa).
20. Section C402.5.6 Doors and access openings to shafts, chutes, stairways and
elevator lobbies is hereby amended to read as follows:
C402.5.6 Doors and access openings to shafts, chutes, stairways and elevator
lobbies. Doors and access openings from conditioned space to shafts, chutes, stairways
and elevator lobbies not within the scope of the fenestration assemblies covered by
Section C402.5.4 shall be gasketed, weather-stripped or sealed. Doors and access
openings on vertical walls from conditioned space to unconditioned attic space shall be
insulated to a minimum of R-7.
Exceptions:
1. Door openings required to comply with Section 716 of the International
Building Code.
2. Doors and door openings required to comply with UL 1784 by the
International Building Code.
21. A new Section C403.1.3 Heating electrification is added to read as follows:
C403.1.3 Heating electrification. Space conditioning equipment shall meet the
requirements for an all-electric building or mixed-fuel building within Section
C401.1.1.
22. Section C403.12.3.1 Protection of piping insulation is hereby amended to read as
follows:
C403.12.3.1 Protection of piping insulation. Piping insulation exposed to the weather
shall be protected from damage, including that caused by sunlight, moisture, equipment
maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape and paint products and similar applications
that require maintenance shall not be permitted.
- 10 -
23. A new Section C404.1.1 Water heating electrification is added to read as follows:
Section C404.1.1 Water heating electrification. Service water-heating equipment
shall meet the requirements for an all-electric building or mixed-fuel building within
Section C401.1.1.
24. Section C405.2.5 Specific application controls is hereby retained in its entirety,
except Item #2 is amended to read as follows:
…
2. Sleeping units shall have control devices or systems that are configured to
automatically switch off all permanently installed luminaires, switched
receptacles, televisions, and the heating, ventilating and air conditioning
system set point raised at least 5 degrees Fahrenheit (3 degrees centigrade) in
the cooling mode and lowered at least 5 degrees Fahrenheit (3 degrees
centigrade) in the heating mode whenever the guest room is unoccupied. All
permanently wired luminaires located in bathrooms within sleeping units in
hotels, motels, boarding houses or similar buildings shall be equipped with
occupant sensors that require manual intervention to energize circuits.
Exceptions:
1. Lighting and switched receptacles controlled by card key controls.
2. Spaces where patient care is directly provided.
3. Existing buildings undergoing an occupancy change to R-1 and that have 8
or less sleeping units.
…
25. Section C405.2.7.1 Daylight shutoff is hereby amended to read as follows:
C405.2.7.1 Daylight shutoff. Lights shall be automatically turned off when daylight is
present or within 30 minutes after sunrise.
26. Section 405.2.7.3 Lighting setback is hereby amended to read as follows:
C405.2.7.3 Lighting setback. Lighting that is not controlled in accordance with
Section C405.2.7.2 shall comply with the following:
1. Be controlled so that the total wattage of such lighting is automatically reduced
by not less than 50 percent by selectively switching off or dimming luminaires
at one of the following times:
1.1 From not later than one hour after business closing to not earlier than one hour
before business opening.
1.2 During any time where activity has not been detected for 15 minutes or more.
2. Luminaires serving outdoor parking areas shall be controlled so that the total
wattage of such lighting is automatically reduced by not less than 50 percent
- 11 -
during any time where activity has not been detected for 15 minutes or more.
Not more than 1,500 watts of lighting power shall be controlled together.
27. Section C405.2.8 Parking garage lighting control is hereby retained in its entirety,
except Item #1 is amended to read as follows:
. . .
1. Lighting power of each luminaire shall be automatically reduced by not less than
50 percent when there is no activity detected within a lighting zone for 15 minutes.
. . .
28. Section C405.12 Energy monitoring is hereby amended to read as follows:
C405.12 Energy monitoring. New buildings with greater than or equal to 600 amp
electric service shall be equipped to measure, monitor, record and report energy
consumption data in compliance with Sections 405.12.1 through C405.12.5.
Exception: R-2 occupancies and individual tenant spaces are not required to
comply with this section provided that the space has its own utility services and
meters and has less than 5,000 square feet (464.5 m2) of conditioned floor area.
29. A new Section C405.13 Cooking and clothes drying electrification is hereby added
to read as follows:
C405.13 Cooking and clothes drying electrification. Clothes drying and cooking
equipment shall meet the requirements for an all-electric building or mixed-fuel
building within Section C401.1.1.
30. TABLE C406.1(2) ADDITIONAL ENERGY EFFICIENCY CREDITS FOR
GROUP R AND I OCCUPANCIES is hereby retained in its entirety, except Sections
C406.7.3 and C406.7.4 in Climate Zone 5B only are amended to read as follows:
TABLE C406.1(2)
ADDITIONAL ENERGY EFFICIENCY CREDITS FOR GROUP R AND I OCCUPANCIES
SECTION
CLIMATE ZONE
5B
C406.7.3: Efficient fossil fuel water heaterb 5
C406.7.4: Heat pump water heaterb 9
31. TABLE C406.1(5) ADDITIONAL ENERGY EFFICIENCY CREDITS FOR
OTHER OCCUPANCIES is hereby retained in its entirety, except Sections C406.7.3
and C406.7.4 in Climate Zone 5B only are amended to read as follows:
TABLE C406.1(5)
ADDITIONAL ENERGY EFFICIENCY CREDITS FOR OTHERa OCCUPANCIES
- 12 -
SECTION CLIMATE ZONE
5B
C406.7.3: Efficient fossil fuel water heaterb 5
C406.7.4: Heat pump water heaterb 9
32. Section C406.9 Reduced air infiltration is hereby amended to read as follows:
C406.9 Reduced air infiltration. Air infiltration shall be verified by testing conducted
in accordance with ASTM E779 or ASTM E1827 by an independent third party. The
measured air-leakage rate of the building envelope shall not exceed 0.19 cfm/ft2 (2.0
L/s × m2) under a pressure differential of 0.3 inches water column (75 Pa), with the
calculated surface area being the sum of the above- and below-grade building envelope.
A report that includes the tested surface area, floor area, air by volume, stories above
grade, and leakage rates shall be submitted to the code official and the building owner.
Exception: For buildings having over 250,000 square feet (25 000 m2) of conditioned
floor area, air leakage testing need not be conducted on the whole building where
testing is conducted on representative above-grade sections of the building. Tested
areas shall total not less than 25 percent of the conditioned floor area and shall be tested
in accordance with this section.
33. TABLE C407.2 REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE
is hereby retained in its entirety and amended only to add Sections C402.2.4 and
C401.1.1 under “Envelope”:
TABLE C407.2
REQUIREMENTS FOR TOTAL BUILDNG PERFORMANCE
SECTION TITLE
Envelope
C402.2.4 Slabs-on-grade
C401.1.1 Building electrification
34. Section C408.2 Mechanical systems and service water-heating systems
commissioning and completion requirements is hereby amended to read as follows:
C408.2 Mechanical systems and service water-heating systems commissioning and
completion requirements. Prior to the final mechanical and plumbing inspections, the
registered design professional or approved agency shall provide evidence of
mechanical systems commissioning and completion in accordance with the provisions
of this section.
Construction document notes shall clearly indicate provisions for commissioning and
completion requirements in accordance with this section and are permitted to refer to
specifications for further requirements. Copies of all documentation shall be given to
the owner or owner’s authorized agent and made available to the code official upon
request in accordance with Sections C408.2.4 and C408.2.5.
- 13 -
Exceptions: The following systems are exempt:
1. Mechanical systems and service water-heating systems in buildings where
the gross conditioned floor area is 15,000 square feet or less.
2. Systems included in Section C403.5 that serve individual dwelling units and
sleeping units.
35. Section C408.2.5.2 Final commissioning report is hereby amended to read as
follows:
C408.2.5.2 Final commissioning report. A report of test procedures and results
identified as “Final Commissioning Report” shall be delivered to the building owner or
owner’s authorized agent and shall be made available to the code official upon request.
The report shall be organized with mechanical system and service hot water system
findings in separate sections to allow independent review. The report shall include the
following:
1. Results of functional performance tests.
2. Disposition of deficiencies found during testing, including details of corrective
measures used or proposed.
3. Functional performance test procedures used during the commissioning process
including measurable criteria for test acceptance, provided herein for
repeatability.
Exception: Deferred tests that cannot be performed at the time of report
preparation due to climatic conditions.
36. A new SECTION C409 INTEGRATED DESIGN ASSISTANCE is hereby added
to read as follows:
C409 INTEGRATED DESIGN ASSISTANCE
C409.1 Scope. This section establishes criteria for compliance using ASHRAE 90.1
Appendix G Performance Rating Method in accordance with the City of Fort Collins
Integrated Design Assistance Program referred to herein as “IDAP”.
C409.2 Requirements for Integrated Design Assistance. Participation in this
compliance path requires:
1. The project must be an active participant in IDAP.
2. The project has qualified for the Design Incentive.
C409.3 Documentation. The documentation required for compliance is the energy
report based on the submitted CD drawing package and approved by the IDAP program
manager.
C409.3.1 Compliance report. Permit submittals shall include the energy report
documenting that the proposed design has annual energy costs less than or equal to the
- 14 -
annual energy costs of the baseline building adjusted to current code and in accordance
with IDAP. The report shall include the following information:
1. Address of the building.
2. An inspection checklist documenting the building component characteristics of
the proposed design. The inspection checklist shall show the estimated annual
energy cost for both the baseline building adjusted to current code and the
proposed design.
3. Name of individual completing the compliance report.
4. Name and version of the compliance software tool.
C409.3.2 Additional documentation. The code official may also require the following
production of documentation of the building component characteristics of the Baseline
Building including the code Building Performance Factor and proposed Building
Performance Factor.
37. Section C501.2 Compliance is hereby amended to read as follows:
C501.2 Compliance. Additions, alterations, repairs, and changes of occupancy to, or
relocation of, existing buildings and structures shall comply with Sections C502, C503,
C504 and C505 of this code, as applicable, and with the provisions for alterations,
repairs, additions and changes of occupancy or relocation, respectively, in the
International Building Code, International Existing Building Code, International Fire
Code, International Fuel Gas Code, International Mechanical Code, International
Plumbing Code, to the extent adopted by the Colorado Plumbing Code, International
Property Maintenance Code and NFPA 70, as adopted by the City. Changes where
unconditioned space is changed to conditioned space shall comply with Section C502.
Exceptions:
1. Additions, alterations, repairs or changes of occupancy complying with
ANSI/ASHRAE/IESNA 90.1.
2. Additions, alterations, repairs or changes of occupancy do not need to
comply with the requirements of C402.2.4 Slab-on-grade floors when it
would require the demolition of existing permanent building construction
components.
38. APPENDIX CB SOLAR READY ZONE--COMMERCIAL is hereby adopted in its
entirety.
39. Section R103.2 Information on construction documents is hereby retained in its
entirety, and amended by the additional of a new Item #10 to read as follows:
R103.2 Information on construction documents.
. . .
10. Glazing area square footage as a percentage of individual wall area by specific
elevation.
- 15 -
40. A new Section R103.6 Permits is hereby added to read as follows:
R103.6 Permits. Procedures related to permits, required inspections, payment of fees
and obtaining required approvals shall be as set forth in Chapter 1 of the adopted
International Building Code.
41. SECTION R104 FEES is deleted in its entirety and replaced with the following:
SECTION R104
FEES
All items relating to fees shall be as specified in Section 109 of the adopted
International Building Code, entitled “Fees.”
42. SECTION R110 MEANS OF APPEALS is hereby deleted in its entirety and replaced
as follows:
SECTION R110
MEANS OF APPEALS
Appeals of decisions, determinations and interpretations of this code shall be made
pursuant to the applicable provisions of Section 113 of the adopted International
Building Code, entitled “MEANS OF APPEALS.”
43. A new SECTION R111 VIOLATIONS is hereby added to read as follows:
SECTION R111 VIOLATIONS. Violations of this code shall be made pursuant to
the applicable provisions of Section 114 of the adopted International Building Code as
amended.
44. A new TABLE R402.1 GENERAL PRESCRIPTIVE COMPLIANCE
REQUIREMENTS is hereby added to read as follows:
TABLE R402.1 GENERAL PRESCRIPTIVE COMPLIANCE REQUIREMENTS
SECTION TITLE
Building Thermal Envelope
R402.2.9 Slab-on-grade floors
R402.5 Maximum fenestration U-Factor and SHGC
Mechanical
TABLE R405.4.2(1)
Service water heating
HWDS = factor for the compactness of the hot water
distribution system.
Compactness ratioa factorb HWDS
1 story 2 or more stories
≤ 60% or ≤ 70% stacked Multi-Family units ≤ 30% 0.05
Electrical Power and Lighting Systems
R404.5 Electric readiness
a) The factor for the compactness of the hot water distribution system is the ratio of the area of the rectangle that bounds the source
- 16 -
of hot water and the fixtures that it serves (the “hot water rectangle”) divided by the floor area of the dwelling.
1. Sources of hot water include water heaters, or in multifamily buildings with central water heating systems, circulation
loops or electric heat traced pipes.
2. The hot water rectangle shall include the source of hot water and the points of termination of all hot water fixture supply
piping.
3. The hot water rectangle shall be shown on the floor plans and the areas shall be computed to the nearest square foot.
4. Where there is more than one water heater, and each water heater serves different plumbing fixtures and appliances it is
permissible to establish a separate hot water rectangle for each hot water distribution system and add the area of these
rectangles together to determine the compactness ratio.
5. The basement or attic shall be counted as a story when it contains the water heater.
6. Compliance shall be demonstrated by providing a drawing on the plans that shows the hot water distribution system
rectangle(s), comparing the area of the rectangle(s) to the area of the dwelling and identifying the appropriate compactness
ratio and HWDS factor.
b) Failure to meet compliance with the Compactness ratio factor shall require a hot water distribution loop with a demand button or
recirculation pump with a timer or installation of electric air source heat pump water heater.
45. TABLE R402.1.2 MAXIMUM ASSEMBLY U-FACTORSA AND
FENESTRATION REQUIREMENTS is hereby deleted in its entirety and replaced
with the following:
TABLE R402.1.2
MAXIMUM ASSEMBLY U-FACTORSa AND FENESTRATION REQUIREMENTS
CLIMATE
ZONE
FENESTRATION
U-FACTOR
SKYLIGHT
U-FACTOR
GLAZED
FENESTRATION
SHGCd
CEILING
U-FACTOR
WOOD FRAME
WALL U-
FACTORe
MASS WALL
U-FACTORb
FLOOR
U-FACTOR
BASEMENT
WALL
U-FACTOR
CRAWL SPACE
WALL U-FACTOR
5 0.28/0.25f 0.55 0.35 0.024 0.045 0.082 0.028 0.050 0.050
For SI: 1 foot = 304.8mm
a. Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source.
b. Mass walls shall be in accordance with Section R402.2.5. Where more than half the insulation is on the interior, the mass wall U-
factors shall not exceed 0.17 in Climate Zones 0 and 1, 0.14 in Climate Zone 2, 0.12 in Climate Zone 3, 0.087 in Climate Zone 4
except Marine, 0.065 in Climate Zone 5 and Marine 4, and 0.057 in Climate Zones 6 through 8.
c. In Warm Humid locations as defined by Figure R301.1 and Table R301.1, the basement wall U-factor shall not exceed 0.360.
d. The SHGC column applies to all glazed fenestration.
e. Class 1 vapor retarders shall not be installed on the interior of framed walls where exterior ci value is less than R-7.5.
f. Where the proposed glazing area is more than 30% of the wall area by elevation, as provided per section R103.2 Information on
construction documents, the second U-factor shall be required.
46. TABLE R402.1.3 INSULATION MINIMUM R-VALUES AND
FENESTRATION REQUIREMENTS BY COMPONENT is hereby deleted in its
entirety and replaced with the following:
TABLE R402.1.3
INSULATION MINIMUM R-VALUES AND FENESTRATION REQUIREMENTS BY
COMPONENT
CLIMATE
ZONE
FENESTRATION
U-FACTORb
SKYLIGHT
U-FACTORb
GLAZED
FENESTRATION
SHGCb
CEILING
R-VALUE
WOOD FRAME
WALL R-VALUEg
MASS WALL
R-VALUEf
FLOOR
R-VALUE
BASEMENTc,e
WALL
R-VALUE
SLABd R-
VALUE &
DEPTH
CRAWL SPACEc,e
WALL R-VALUE
5 0.28/0.25h 0.55 0.35 60 30 or 20+5ci or
13+10ci or
0+20ci or 23
+3ci
13/17 38 15ci or 19 or 13
+ 5ci
10ci, 4 ft 15ci or 19 or 13 +
5ci
For SI: 1 foot = 304.8 mm.
ci = continuous insulation
a. R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or
design thickness of the insulation, the installed R-value of the insulation shall be not less than the R-value specified in the table.
b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
c. “5ci or 13” means R-5 continuous insulation (ci) on the interior or exterior surface of the wall or R-13 cavity insulation on the interior
side of the wall. “10ci or 13” means R-10 continuous insulation (ci) on the interior or exterior surface of the wall or R-13 cavity
insulation on the interior side of the wall. “15ci or 19 or 13 + 5ci” means R-15 continuous insulation (ci) on the interior or exterior
- 17 -
surface of the wall; or R-19 cavity insulation on the interior side of the wall; or R-13 cavity insulation on the interior of the wall in
addition to R-5 continuous insulation on the interior or exterior surface of the wall.
d. R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insulation R-value for
slabs. As indicated in the table. The slab-edge insulation for heated slabs shall not be required to extend below the slab. Insulation
located below grade shall be extended the distance provided in the table or to top of footing.
e. The first value is cavity insulation; the second value is continuous insulation. Therefore, as an example, “13 + 5” means R-13 cavity
insulation plus R-5 continuous insulation.
f. Mass walls shall be in accordance with Section R402.2.5. The second R-value applies where more than half of the insulation is on
the interior of the mass wall where more than half the insulation is on the interior, the mass wall U-factor shall be the same as the
frame wall U- factor.
g. Class 1 vapor retarders shall not be installed on the interior of framed walls where exterior ci value is less than R-7.5.
h. Where the proposed glazing area is more than 30% of the wall area by elevation, as provided per section R103.2 Information on
construction documents, the second U-factor shall be required.
47. Section R402.2 Specific insulation requirements is hereby amended to read as
follows:
R402.2 Specific insulation requirements. In addition to the requirements of Section
R402.1, insulation shall meet the specific requirements of Sections R402.2.1 through
R402.2.12. All insulation shall be installed to meet Residential Energy Services
Network (RESNET) Grade I standard.
48. Section R402.2.4 Access hatches and doors is hereby amended only as to Exception
#1 to read as follows:
R402.2.4 Access hatches and doors.
. . .
Exceptions:
1. Vertical entries providing access from conditioned spaces to unconditioned spaces
that are not required to be a swinging door and shall be less than or equal to U-0.10
or have an average insulation R-value of R-10 or greater. If foam plastic insulation
is used, it shall comply with the International Residential Code Section R316.5.3
Attics.
. . .
49. Section R402.2.8.1 Basement wall insulation installation is hereby amended to read
as follows:
R402.2.8.1. Basement wall insulation installation. Where basement walls are
insulated, the insulation shall be installed from the top of the basement wall down to
the basement floor.
50. Section R402.2.9.1 Slab-on-grade floor insulation installation is hereby amended to
read as follows:
R402.2.9.1 Slab-on-grade floor insulation installation. Where installed, the
insulation shall extend downward from the top of the slab on the outside or inside of
the foundation wall. Insulation located below grade shall be extended the distance
provided in Table R402.1.3 as applicable, by any combination of vertical insulation,
- 18 -
insulation extending under the slab or insulation extending out from the building.
Insulation extending away from the building shall be protected by pavement or by not
less than 10 inches (254 mm) of soil. The top edge of the insulation installed between
the exterior wall and the edge of the interior slab shall be permitted to be cut at a 45-
degree (0.79 rad) angle away from the exterior wall.
51. Section R402.2.10.1 Crawl space wall insulation installations is hereby deleted in
its entirety and replaced with the following:
R402.2.10.1 Crawl space wall insulation installations. Where crawl space wall
insulation is installed, it shall be permanently fastened to the interior or exterior wall
and shall extend downward from the top of foundation wall to the footing. Exposed
earth in unvented crawl space foundations shall be covered with a continuous Class I
vapor retarder in accordance with the International Building Code or International
Residential Code, as applicable. Joints of the vapor retarder shall overlap by 6 inches
(153 mm) and be sealed or taped. The edges of the vapor retarder 6 inches (153 mm)
up stem walls and footings and shall be attached and sealed to the stem walls and
footing pads.
52. TABLE R402.4.1.1 AIR BARRIER, AIR SEALING AND INSULATION
INSTALLATIONa is hereby amended as follows:
TABLE R402.4.1.1 AIR BARRIER, AIR SEALING AND INSULATION
INSTALLATIONa
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION
CRITERIA
General requirements
The building’s thermal envelope shall contain a
continuous air barrier that is in alignment with the
insulation on the conditioned and unconditioned side
of the assembly.b
All penetrations, breaks or joints in the air barrier
shall be air sealed.
Air-permeable insulation shall not be used as an air
sealing material.
Air- permeable insulation shall be enclosed inside
the air barrier assemblyᵇ.
. . . . . . . . .
Walls
The junction of the foundation and the sill plate shall
be sealed.
The junction of the top plate and the top of walls
that are adjacent to unconditioned space shall be
sealed.
Knee walls shall have an air barrier installed on both
sides of the insulation and be sealed on all edges.
Cavities within corners and headers of frame walls
shall be insulated by completely filling the cavity with
a material having a thermal resistance, R-value, of not
less than R-3 per inch. Exterior thermal envelope
insulation for framed walls shall be installed in
substantial contact and continuous alignment with the
air barrier.
. . . . . . . . .
Rim joists
Rim joists shall include an exterior air barrierb
The junctions of the rim board to the sill plate and
the rim board and the subfloor shall be air sealed.
Rim joists shall be insulated to a minimum R-15 if
spray foam or R-values indicated for Wood Frame
Walls within TABLE R402.1.3 or the exterior walls
minimum R-value indicated in the Proposed Design
for SECTION R405 TOTAL BUILDING
PERFORMANCE. The insulation shall maintain
permanent contact with the exterior rim board.b
Floors, separating
conditioned from
unconditioned space,
including cantilevered
floors and floors above
garages
The air barrier shall be installed, and air sealed at
any exposed edge of the insulated floor cavity
adjacent to unconditioned space.
Air permeable insulation installed in floor cavities
shall be enclosed in a six-sided cavity.
Floor framing cavity insulation shall be installed in
accordance with the requirements of Section R402.2.7.
. . . . . . . . .
- 19 -
Shower/tub and fireplaces
on exterior walls
The air barrier installed at exterior walls adjacent to
showers and tubs shall separate the wall from the
shower or tub.
Exterior framed walls adjacent to showers, tubs and
fireplaces shall be insulated.
. . . . . . . . .
HVAC Register boots
All HVAC supply and return register boots shall be
sealed to the subfloor, wall covering, or ceiling
penetrated by the boot.
Insulation shall be fitted tightly around HVAC supply
and return register boots located in the building’s
thermal envelope to maintain its required assembly R-
value.
. . . . . . . . .
a. Inspection of log walls shall be in accordance with the provisions for ICC 400.
b. Air barrier and insulation full enclosure is not required in unconditioned/ventilated attic spaces and rim joists.
53. Section R402.4.1.2 Testing is hereby deleted in its entirety and replaced with the
following:
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having
an air leakage rate not exceeding three air changes per hour or 0.16 CFM per square
foot of dwelling unit enclosure area. Testing shall be conducted in accordance with
Section 802 of the RESNET Mortgage Industry National Home Energy Rating
Standards and RESNET/ICC 380, ASTM E779 or ASTM E1827 and the City of Fort
Collins Building Code Air Tightness Testing Protocol, New Attached and Detached
Single Family Dwellings and reported at a pressure of 0.2 inch w.g. (50 Pascals). Where
required by the code official, testing shall be conducted by an approved third party. A
written report of the results of the test shall identify the tester conducting the test, and
their applicable testing certifications, and shall be provided to the code official. Testing
shall be performed at any time after creation of all penetrations of the building thermal
envelope.
Exception: When testing individual dwelling units, an air leakage rate not exceeding
0.30 cubic feet per minute per square foot [0.008 m3/(s × m2)] of the dwelling unit
enclosure area, tested in accordance with ANSI/RESNET/ICC 380, ASTM E779 or
ASTM E1827 and The City of Fort Collins Building Code Protocol for New
Multifamily Building Air Tightness Testing and reported at a pressure of 0.2 inch w.g.
(50 Pa), shall be an accepted alternative permitted in all climate zones for stacked
multiple family building dwelling units.
54. Section R402.4.4 Rooms containing fuel-burning appliances is amended to read as
follows:
R402.4.4 Rooms containing fuel-burning appliances In new construction, where
open combustion fuel-burning appliances are installed, the appliances and combustion
air opening shall be located outside the building thermal envelope or enclosed in a room
that is isolated from inside the thermal envelope. Such rooms shall be sealed and
insulated in accordance with the envelope requirements of Table R402.1.3, where the
walls, floors and ceilings shall meet a minimum of the basement wall R-value
requirement. The door into the room shall be fully gasketed and any water lines and
ducts in the room insulated in accordance with Section R403. The combustion air duct
shall be insulated where it passes through conditioned space to an R-value of not less
than R-8.
Exceptions:
- 20 -
1. Direct vent appliances with both intake and exhaust pipes installed
continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006
of the International Residential Code.
55. Section R402.5 Maximum fenestration U-factor and SHGC is hereby amended to
read as follows:
The area-weighted average maximum fenestration U-factor permitted using tradeoffs
from Section R402.1.5 or R405 shall be 0.32 for vertical fenestration and 0.75 for
skylights. The area-weighted average maximum fenestration SHGC permitted using
tradeoffs from Section R405 shall be 0.35.
Exception: The maximum U-factor and solar heat gain coefficient (SHGC) for
fenestration shall not be required in storm shelters complying with ICC 500.
56. Section R403.3.2 Ducts located in conditioned space is hereby deleted in its entirety
and replaced with the following:
R403.3.2 Ducts located in conditioned space. For ductwork to be considered as inside
conditioned space, the duct system shall be located completely within the continuous
air barrier and within the building thermal envelope.
57. Section R403.3.6 Duct leakage is hereby amended only as to Item #3 to read as
follows:
. . .
3. Test for ducts within thermal envelope: Where all ducts and air handlers are
located entirely within the building thermal envelope, total leakage shall be less
than or equal to 4.0 cubic feet per minute (226.6 L/min) per 100 square feet
(9.29 m2) of conditioned floor area.
58. Section R403.4.1 Protection of piping insulation is hereby amended to read as
follows:
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall
be protected from damage, including that caused by sunlight, moisture, equipment
maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape and paint products and similar applications
that require maintenance shall be prohibited.
59. Section R403.7 Equipment sizing and efficiency rating is hereby amended to read
as follows:
R403.7 Equipment sizing and efficiency rating. Heating and cooling equipment shall
be designed and sized in accordance with International Residential Code Section
- 21 -
M1401.3 and performance will be verified in accordance with International Residential
Code Section M1309.
60. A new Section R404.4 Occupant sensor controls is hereby added to read as follows:
R404.4 Occupant sensor controls. In multifamily buildings, occupant sensor controls
shall be provided to automatically reduce connected lighting power by not less than 50
percent during periods when no occupants are present in common corridors and
common enclosed stairwells.
Lighting in means of egress shall comply with the luminance or uniformity criteria
required by the International Building Code when occupied.
Exception: Automatic power reduction shall not be used to control battery back-up
emergency lighting and exit signage.
61. A new Section R404.5 Electric readiness is added to read as follows:
R404.5 Electric readiness. Water heating, space heating, conventional cooking
equipment and dryers shall meet the requirements of R404.5 through 404.5.8. Unless
otherwise noted herein the equipment shall comply with the National Appliance Energy
Conservation Act of 1987 (NAECA).
R404.5.1 Water heating electrification. All newly constructed residential buildings
shall be constructed with an electric heat pump water heating system or pre-wired to
support an electric heat pump water heating system.
R404.5.2 Future water heating electrical requirements. Residential buildings using
gas or propane as the fuel source for heating domestic water shall include a dedicated
125 volt, 20 amp electrical receptacle that is connected to the electric panel with a
120/240 volt 3 conductor, 12 AWG copper branch circuit within 3 feet from the water
heater and accessible to the water heater with no obstructions.
Exception: Installed conduit with pull string sized to accommodate future water
heating electrical requirements.
R404.5.3 Labeling. Both ends of the unused conductor shall be labeled with the word
“SPARE” and be electrically isolated.
R404.5.4 Circuit. A single pole circuit breaker space shall be reserved in the electrical
panel adjacent to the circuit described in Section R304.1.1 and labeled with the words
“Future 240V Use.”
R404.5.5 Water heating serving multiple dwelling units. Water heating systems
supporting multiple dwelling units shall meet the requirements of Sections R404.5,
R404.2.2, R404.2.3 and Sections C404.3 through C404.7.
- 22 -
R404.5.6 Space heating for electrification. Space heating equipment shall be
constructed with a ground-source electric heat pump or an electric cold climate heat
pump specifically designed to heat at the Winter Outdoor, Design Dry-Bulb temp
defined in Section 301.5 of this code or pre-wired to support the aforementioned
electric heat pump system. Electric resistance strip heat shall only serve as defrost,
emergency back-up heat or supplemental heat at outdoor temperatures less than or
equal to 15oF.
R404.5.7 Future heating and cooling electrical requirements. Residential buildings
using gas or propane as the fuel source for space conditioning shall include a dedicated
208/240 volt, 30 amp or greater electrical circuit connected to the electric panel,
terminating within 3 feet from the designated future location of the compressor unit
and shall comply with:
1. Both ends of the conductor shall be labeled with the word “For Future Heat
Pump Heat/Cooling” and electrically isolated;
2. A double pole circuit breaker in the electrical panel labeled with the words “For
Future Heat Pump Heater”; and
3. Other electrical components, including conductors and receptacles supporting
this section and installed in accordance with the National Electric Code.
Exceptions:
1. Where the heating load is less than or equal to 6.0 Btu/h/ft2 at design
temperature, electric resistance heating shall be permitted.
2. Where the building is provided with a dedicated branch circuit in
compliance with NEC article 440.4 based on heat pump space heating
equipment sized in accordance with R403.7 and terminating
within 3 feet (914 mm) of the location with no obstructions. Both ends of
the branch circuit shall be labeled “For Future Heat Pump Heater.”
3. Where an electrical circuit in compliance with NEC article 440.4 exists for
space cooling equipment.
4. Where conduit with pull string sized to accommodate future heating
electrical requirements is installed.
R404.5.8 Future electric heating and cooling requirements serving multiple
dwelling units. Equipment serving more than one dwelling unit shall include all three
requirements from R404.5.7. The electric capacity, determined at 240 volts per the
National Electrical Code, shall include raceways and service and panel capacity for a
termination point 3 feet from each gas space conditioning outlet.
62. SECTION R405 TOTAL BUILDING PERFORMANCE is hereby amended to read
as follows:
SECTION R405 TOTAL BUILDING PERFORMANCE
R405.1 Scope. This section establishes criteria for compliance using total building
- 23 -
performance analysis. Such analysis shall include heating, cooling, mechanical
ventilation and service water-heating energy only.
Exception: In addition to all required sections, new buildings, additions, or
alterations where the primary heat source is electrical shall utilize a ground-source
electric heat pump or a cold climate heat pump specifically designed to heat at the
Winter Outdoor, Design Dry-Bulb temp defined in Section R301.5 of this code.
Electric resistance strip heat shall only serve as defrost, emergency back-up heat or
supplemental heat at outdoor temperatures less than or equal to 15oF.
63. TABLE R405.2 REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE
is here by retained in its entirety, and amended only to add the information below to
the Sections and Titles:
TABLE R405.2
REQUIREMENTS FOR TOTAL BUILDING PERFORMANCE
SECTION TITLE
. . .
Building Thermal Performance
R402.2.9 Slab-on-grade floors
Mechanical
TABLE R405.4.2(1),
Service water heating
HWDS = factor for the compactness of the hot water
distribution system.
Compactness ratiob factorc HWDS
1 story 2 or more stories
≤ 60% ≤ 30% 0.05
Electrical Power and Lighting Systems
R404.5 Electric readiness
. . .
b. The factor for the compactness of the hot water distribution system is the ratio of the area of the rectangle that bounds the source
of hot water and the fixtures that it serves (the “hot water rectangle”) divided by the floor area of the dwelling.
1. Sources of hot water include water heaters, or in multifamily buildings with central water heating systems, circulation loops
or electric heat traced pipes.
2. The hot water rectangle shall include the source of hot water and the points of termination of all hot water fixture supply piping.
3. The hot water rectangle shall be shown on the floor plans and the areas shall be computed to the nearest square foot.
4. Where there is more than one water heater, and each water heater serves different plumbing fixtures and appliances it is
permissible to establish a separate hot water rectangle for each hot water distribution system and add the area of these
rectangles together to determine the compactness ratio.
5. The basement or attic shall be counted as a story when it contains the water heater.
6. Compliance shall be demonstrated by providing a drawing on the plans that shows the hot water distribution system rectangle(s),
comparing the area of the rectangle(s) to the area of the dwelling and identifying the appropriate compactness ratio and WDS
factor.
c. Failure to meet compliance with the Compactness ratio factor shall require a hot water distribution loop with a demand button or
recirculation pump with a timer or installation of electric air source heat pump water heater.
64. Section R405.3.2.2 Compliance report for certificate of occupancy is hereby
retained in its entirety and amended only by adding Item #8 to read as follows:
…
8. A passing “Confirmed” energy rating report, including the Home Energy
Rating Certificate with corresponding HERS score, reflecting as-built data, is
- 24 -
required to receive a Certificate of Occupancy for final approval of a completed
home.
65. Section R406.2 ERI compliance is hereby amended to read as follows:
R406.2 ERI compliance. Compliance based on the Energy Rating Index (ERI)
requires that the rated design meets all of the following:
1. The requirements of the sections indicated within Table R405.2.
2. Maximum ERI of Table R406.5
66. Section R501.2 Compliance is hereby amended to read as follows:
R501.2 Compliance. Additions, alterations, repairs or changes of occupancy to, or
relocation of, an existing building, building system or portion thereof shall comply with
Section R502, R503, R504 or R505, respectively, in this code. Changes where
unconditioned space is changed to conditioned space shall comply with Section R502.
Exception: Additions, alterations, repairs or changes of occupancy do not need to
comply with the requirements of R402.2.9 Slab-on-grade floors when it would require
the demolition of existing permanent building construction components.
67. Section R502.1 General is hereby amended to read as follows:
R502.1 General. Additions to an existing building, building system or portion thereof
shall conform to the provisions of this code as those provisions relate to new
construction. Additions shall not create an unsafe or hazardous condition or overload
existing building systems.
68. Section R502.3.1 Building envelope is hereby amended to read as follows:
R502.3.1 Building envelope. New building envelope assemblies that are part of the
addition shall comply with Sections R402.1, R402.2, R402.3.1 through R402.3.5, and
R402.4.
Exceptions:
1. Where new construction roof lines for additions are built to match existing
roof lines a minimum of uncompressed R-19 insulation extending over the
wall top plate at the eaves shall be allowed.
2. Where demolition of existing permanent building construction components
is required to meet the requirements of R402.2.9 Slab-on-grade floors.
69. A new Section R502.4 Compliance is hereby added to read as follows:
R502.4 Compliance. An addition shall be deemed to comply with this code where
the existing building with the addition complies prescriptively (using Total UA) or
does not use more energy than the existing building and demonstrates compliance
using either Building Performance energy cost, or ERI compliance option listed
- 25 -
below. Existing building envelope and energy features shall be evaluated per
ANSI/RESNET/ICC 301-2019 or ANSI/BPI 1200-S-2017 standards.
Exceptions: Unaltered portions of the existing building or building system are not
required to comply with this code section if
1. The existing building was constructed to the 2009 International Energy
Conservation Code or later; or
2. The addition is less than 30% of the total conditioned floor area of the
existing building; or
3. The building has undergone a documented energy efficiency upgrades to
the envelope within the last 10 years.
R502.4.1 Existing plus addition (Prescriptive compliance). Total UA compliance
verification in Section R402.1.5 shall demonstrate that the existing building plus the
addition, has a total UA that is less than or equal to the Total UA of the existing building
prior to the addition. This method requires the project to create two Total UA
compliance verification reports as outlined in Section R502.4.1.1.
R502.4.1.1 Reporting.
For permitting, the following are required:
1. A Total UA compliance benchmark report of the existing structure prior to
construction.
2. A Total UA compliance report of the existing building, plus the addition based
on the proposed design.
R502.4.2 Existing building plus addition compliance (Total Building
Performance). Total building performance Section R405 compliance verification shall
demonstrate that the existing building plus the addition uses no more energy than the
existing building did prior to the addition. This method requires the project to create
cost compliance verification at three stages as outlined in Section R502.4.2.2.
R502.4.2.2 Reporting.
For permitting, the following are required:
1. A baseline total building performance cost compliance report of the existing
structure prior to construction.
2. Projected total building performance cost compliance report of the existing
building plus the addition based on the proposed design for the building in its
entirety.
For Certificate of Occupancy, a final confirmed total building performance cost
compliance report shall be submitted prior to final inspection.
R502.4.3 Existing plus addition compliance (Energy Rating Index Alternative).
An ERI score shall demonstrate that the existing building plus the addition uses no
more energy than the existing building did prior to the addition. This method requires
the project to obtain an ERI score at three stages as outlined in Section R502.2.3.1
- 26 -
R502.4.3.1 Reporting.
For permitting, the following are required:
1. For permitting: A baseline ERI of the existing structure prior to construction.
2. For Permitting: A projected ERI of the existing building plus the addition based
on the proposed design for the building in its entirety.
For Certificate of Occupancy, a confirmed ERI report shall be submitted prior to final
inspection.
70. CHAPTER 6 REFERENCED STANDARDS is hereby amended by adding, in
alphabetical order, the following additional referenced standard:
RESNET® reference standard Grade I Insulation and Section 802 of the RESNET
Mortgage Industry National Home Energy Rating Standards Referenced in Amended
2021 IECC Section C402.2 and Section R402.4.1.2.
71. APPENDIX RB SOLAR-READY PROVISIONS--DETACHED ONE- AND
TWO-FAMILY DWELLINGS AND TOWNHOUSES is hereby adopted in its
entirety.
Section 6. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
ORDINANCE NO. 023, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 2 OF THE
CODE OF THE CITY OF FORT COLLINS FOR THE PURPOSE OF
REPEALING THE 2018 INTERNATIONAL RESIDENTIAL CODE AND
ADOPTING THE 2021 INTERNATIONAL RESIDENTIAL CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both to align the publication years of the codes and
because the 2021 publications contain improvements in construction code regulation; and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the 2021 International Residential Code be
adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in the newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
2
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Residential Code
(“IRC”) and hereby adopts the 2021 IRC as amended by this Ordinance.
Section 3. That Section 5-26(d) of the Code of the City of Fort Collins is hereby amended
as to read follows:
(d) Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-16-202
and Article II, Section 7 of the Charter, the City Council has adopted the 2021 International
Residential Code published by the International Code Council, as amended by the City,
which shall have the same force and effect as though set forth in full herein. The subject
matter of the International Residential Code adopted herein includes comprehensive
provisions and standards for the protection of the public health and safety by prescribing
regulations governing the construction, alteration, enlargement, relocation, replacement,
repair, equipment, use and occupancy, location, removal and demolition of, and its
applicability is hereby limited to, individual nonattached one- and two-family dwellings
and multiple single-family dwellings (townhouses) not more than three (3) stories above
grade in height with a separate means of egress, and their accessory structures. As provided
in the 2021 International Residential Code, Appendices are not adopted except as expressly
set forth in Section 5-30.
Section 4. That Section 5-30 of the Code of the City of Fort Collins is hereby repealed
and reenacted to read as follows:
Sec. 5-30. Amendments and Deletions to the 2021 International Residential Code.
The 2021 International Residential Code adopted in Section 5-26 is hereby amended to
read as follows:
1. Section R101.1 Title is hereby amended to read as follows:
R101.1 Title. These provisions shall be known as the Residential Code for One- and
Two-family Dwellings of the City of Fort Collins and shall be cited as such and will be
referred to herein as “this code.”
3
2. Section R102.4 Referenced codes and standards is hereby amended to read as
follows:
R102.4 Referenced codes and standards. The codes and standards referenced in this
code shall be those that are listed in Section 101.4 of the adopted International Building
Code, entitled “Referenced Codes,” and shall be considered part of the requirements of
this code to the prescribed extent of each such reference and as further regulated in
Sections R102.4.1 and R102.4.2.
Exception: Where enforcement of a code provision would violate the conditions
of the listing of the equipment or appliance, the conditions of the listing and
manufacturer’s instructions shall apply.”
3. Section R103 DEPARTMENT OF BUILDING SAFETY is hereby deleted in its
entirety and replaced with the following:
SECTION R103 CODE ADMINISTRATION
R103.1 Entity charged with code administration shall be as determined in
accordance with Section 103 of the adopted International Building Code, entitled
“CODE ADMINISTRATION.”
4. Section R105.2 Work exempt from permit, Building is amended to read as follows;
however, the subsections for Electrical, Gas, Mechanical and Plumbing are retained
in their entirety:
R105.2 Work exempt from permit. Exemption from permit requirements of this code
shall not be deemed to grant authorization for any work to be done in any manner in
violation of the provisions of this code or any other laws or ordinances of this
jurisdiction. Permits shall not be required for the following:
R105.2 Building:
1. Other than storm shelters, one-story detached accessory structures for lawn
and garden equipment storage, tool storage and similar uses, including
arbors, pergolas, and similar structures, provided that the floor area does not
exceed 120 square feet (11.15 m2) or 8 feet (2.438 m) in height, do not house
flammable liquids in quantities exceeding 10 gallons (38 L) per building,
and the structures are located at least 3 feet (0.914 m) from an adjoining
property line.
2. Fences not over 6 feet (1829 mm) high.
3. Retaining walls that are not over 4 feet (1219 mm) in height measured from
the low side grade to the top of the wall, unless supporting a surcharge,
4
provided that the horizontal distance to the next uphill retaining wall is at least
equal to the total height of the lower retaining wall.
4. Water tanks supported directly upon grade if the capacity does not exceed
5,000 gallons (18 927 L) and the ratio of height to diameter or width does not
exceed 2 to 1.
5. Sidewalks and driveways.
6. Painting, papering, tiling, carpeting, cabinets, counter tops and similar finish
work.
7. Prefabricated swimming pools that are less than 24 inches (610 mm) deep.
8. Swings and other playground equipment, or playhouse/play structures not
exceeding 120 square feet (11.15 m2), including no more than one elevated
playhouse or play structure per lot designed, and said equipment or structure
is used exclusively for play. Elevated playhouses or play structures shall not
exceed 64 square feet (5.9 m2) of floor area nor 6 feet (1.82 m) in height
measured from the floor to the highest point of such structure.
9. Window awnings supported by an exterior wall which do not project more than
54 inches (1372 mm) from the exterior wall and do not require additional
support. Storm window, storm door and rain gutter installation except that, for
structures that are fifty years of age or older, historic review pursuant to Chapter
14 of the City Code first must be completed.
10. Decks not exceeding 200 square feet (18.58m2) in area, that are not more than
30 inches (762 mm) above grade at any point, are not attached to a dwelling
and do not serve the exit door required by Section R311.4.
11. Roofing repair or replacement work not exceeding one square (100 square feet)
of covering per building.
12. Replacement of nonstructural siding that is not part of a fire-rated assembly
when removal of siding is performed in accordance with State laws regarding
asbestos and lead paint except that, for structures fifty years of age or older,
historic review pursuant to Chapter 14 of the City Code first must be completed.
13. Shade cloth structures constructed for nursery or agricultural purposes, not
including service systems. Hoop houses not for public use that are constructed
with a flexible frame such as PVC tubing used for starting plants.
5. Section R105.3.2 Time limitation of application is hereby amended to read as
follows:
5
R105.3.2 Time limitation of application An application for a permit for any proposed
work shall be deemed to have been abandoned 180 days after the date of filing unless
such application has been pursued in good faith or a permit has been issued; except that
the building official is authorized to grant one or more extensions of time for additional
periods not exceeding 180 days each. The extension shall be requested in writing and
justifiable cause demonstrated. Applications which have expired for 30 days or more
will be considered void, unless the building official determines, in their reasonable
discretion, that an extension of no more than 180 days should be allowed due to
conditions beyond the applicant’s control.
6. Section R105.5 Expiration is hereby amended by adding a second paragraph to read
as follows:
R105.5 Expiration. Every permit issued shall become invalid unless the work
authorized by such permit is commenced within 180 days after its issuance or after
commencement of work if more than 180 days pass between inspections. The building
official is authorized to grant, in writing, one or more extensions of time, for periods
not more than 180 days each. The extension shall be requested in writing and justifiable
cause demonstrated.
Both prior to and subsequent to the effective date of this code, any work authorized by
a permit regulated by this code or any other building construction code administered
by the building official that involves the construction or alteration of an exterior
building component, assembly or finish material, such as the foundation, wall and roof
framing, sheathing, siding, fenestration, and roof covering, shall be fully finished and
completed for permanent outdoor exposure within 24 months of date of this issuance
of such permit.
7. A new Section R105.10 Premises Identification is hereby added to read as follows:
R105.10 Premises Identification During Construction. The approved permit number
and street address number shall be displayed and plainly visible and legible from the
public street or road fronting the property on which any new building is being
constructed.
8. A new Section R105.11 Transfer of permits is hereby added to read as follows:
R105.11 Transfer of permits. A current valid building permit may be transferred from
one party to another upon written application to the building official with consent of
both parties. When any changes are made to the original plans and specifications that
substantially differ from the plans submitted with the permit, as determined by the
building official, a new plan review fee shall be paid as calculated in accordance with
Section R108. A fee of $50 shall be paid to cover administrative costs for all building
permit transfers. No change shall be made in the expiration date of the original permit.
9. Section R106.1.4 Information for construction in flood hazard areas is hereby
6
deleted its entirety and replaced with the following:
R106.1.4 Information for construction in flood hazard areas. For buildings or
structures regulated under the scope of this code that are in whole or in part located in
flood hazard areas, construction documents shall be submitted in accordance with the
City Code, Chapter 10, entitled “Flood Prevention and Protection.”
10. A new Section R106.1.6 Grading performance plans and certificate is hereby added
to read as follows:
R106.1.6 Grading performance plans and certificate. Every building permit
application for a new building regulated by this code shall be accompanied by a site
drainage/grading performance plan as prescribed by City standards. Drainage plans
shall be submitted to and approved by the City’s Stormwater Utility prior to the
issuance of a permit.
11. Section R106.3.1 Approval of construction documents is hereby amended to read as
follows:
R106.3.1 Approval of construction documents. Where the building official issues a
permit, the construction documents shall be approved in writing or by a stamp
indicating the approved permit number. One set of construction documents so reviewed
shall be retained by the building official. The other set shall be returned to the applicant,
shall be kept at the site of work and shall be open to inspection by the building official
or a duly authorized representative.
12. SECTION R108 FEES is hereby deleted in its entirety and replaced with the
following:
SECTION R108 FEES
R108.1 Fees. All items relating to fees shall be as specified in Section 109 of the
adopted International Building Code, entitled “FEES.”
13. A new Section R109.1.7 Site Survey required is hereby added to read as follows:
R109.1.7 Site Survey required. A survey or improvement location certificate of the
site on which a new building or addition is to be constructed may be required by the
building official to verify that the structure is located in accordance with the approved
plans and any other regulations of the City.
14. Section R110.2 Change in use is hereby amended to read as follows:
R110.2 Change in use. Changes in the character, use and/or occupancy classification
(See Chapter 3 of International Building Code) of an existing structure shall not be
made except as specified in Sections 506 and 507 of the International Existing Building
7
Code, approved by the building official and the structure is in conformance with this
code and the Building Code enacted by the City.
15. SECTION R112 BOARD OF APPEALS is hereby deleted in its entirety and replaced
with the following:
R112 BOARD OF APPEALS
R112.1 General. Appeals of decisions, determinations and interpretations of this code
shall be made pursuant to applicable provisions as set forth in Section 113 of the
adopted International Building Code, entitled “MEANS OF APPEALS.”
16. Section R113.4 Violation penalties is hereby amended to read as follows:
R113.4 Violation penalties. Any person who violates a provision of this code or fails
to comply with any of the requirements thereof or who erects, constructs, alters or
repairs a building or structure in violation of the approved construction documents or
directive of the building official, or of a permit or certificate issued under the provisions
of this code, commits a civil infraction and is subject to the provisions contained in §
1-15 of the City Code. Each day that a violation continues shall be deemed a separate
offense.
17. A new Section R113.5 Work commencing before permit issuance is hereby added
to read as follows:
R113.5 Work commencing before permit issuance. In addition to penalties set forth
in R113.4, any person or firm who, before obtaining the necessary permit(s),
commences any construction of, or work on, a building, structure, electrical, gas,
mechanical or plumbing system that is not otherwise exempted from obtaining a permit,
may be subject to a stop work order and a work without a permit fee in addition to the
required permit fee as established by the building official.
18. SECTION R202 DEFINITIONS is hereby amended to modify, or add, in alphabetical
order, the following definitions:
BASEMENT. That portion of a building located partly or completely below grade,
wherein the underside of the floor system immediately above is 72 inches (1829 mm)
or more above the surface of an approved permanent basement floor system.
CITY shall mean the municipal corporation of Fort Collins, Colorado, including its
physical location and boundaries.
CRAWLSPACE. That portion of a building that is conditioned or non-conditioned
space located partly or completely below grade (excluding the under-floor space
beneath below-grade structural floor systems), wherein the underside of the adjacent
finished floor above is less than 72 inches (1829 mm) above the bottom surface of such
8
crawlspace.
DOWN DIRECTIONAL LUMINAIRE. Down directional luminaire lighting directs
light straight down from the fixture.
DWELLING. Shall mean a building used exclusively for residential occupancy and
for permitted accessory uses, including single-family dwellings, two-family dwellings
and multi-family dwellings. The term dwelling shall not include hotels, motels,
homeless shelters, seasonal overflow shelters tents or other structures designed or used
primarily for temporary occupancy. Any dwelling shall be deemed to be a principal
building.
DWELLING UNIT. Shall mean one or more rooms and a single kitchen and at least
one bathroom, designed, occupied or intended for occupancy as separate quarters for
the exclusive use of a single family for living, cooking and sanitary purposes, located
in a single-family, two-family or multi-family dwelling or mixed-use building.
FLOOR AREA. The area included within the surrounding exterior walls of a building
or portion thereof, exclusive of vent shafts and courts. The floor area of a building, or
portion thereof, not provided with surrounding exterior walls shall be the usable area
under the horizontal projection of the roof or floor above.
FULLY SHIELDED LUMINAIRE. A light fixture that has a solid barrier (cap) at
the top of the fixture in which the lamp (bulb) is located. The fixture is angled so the
lamp is not visible below the barrier (no light visible below the horizontal angle).
ROOM, SLEEPING (BEDROOM). A habitable space within a dwelling or other
housing unit designed primarily for the purpose of sleeping. The presence of a bed, cot,
mattress, convertible sofa or other similar furnishing used for sleeping purposes is
indicia for determining that such space or room qualifies as a sleeping room. The
presence of closets and similar storage facilities is not considered a relevant factor in
determining whether or not a room is a sleeping room.
SITE. A parcel of land bounded by a property line or a designated portion of a public
right-of-way.
TOWNHOUSE: A single-family dwelling unit constructed in a group of two or more
attached individual units, each of which is separated from the other from the foundation
to the roof and is located entirely on a separately recorded and platted parcel of land
(site) bounded by property lines that is deeded exclusively for such single-family
dwelling.
VISITABILITY: A measure of a residence’s ease of access for persons with
disabilities.
19. Section 301.1.3 Engineered Design is hereby amended to read as follows:
9
R301.1.3 Engineered design. When a building of otherwise conventional light-frame
construction contains structural elements not conforming to this code, these elements
shall be designed in accordance with accepted engineering practice. The extent of such
design need only demonstrate compliance of nonconventional elements with other
applicable provisions and shall be compatible with the performance of the conventional
framed system. Engineered design in accordance with the Building Code enacted by
the City, is permitted for all buildings, structures, and portions thereof, included in the
scope of this code.
20. Table R301.2 Climatic and Geographic Design criteria, the table is amended to read
as follows. The thermal design parameters in Table R301.2 shall be used for mechanical
load calculations and designs.
10
21. Section R302.2 Townhouses is hereby amended to read as follows:
R302.2 Townhouses. Townhouses shall be provided with a fire-suppression system in
accordance with Section P2904 of this code, NFPA 13D, or other approved equivalent
sprinkler system. Walls separating townhouse units shall be constructed in accordance
with section R302.2.1 or R302.2.2.
22. Section R302.2.3 Continuity is hereby amended to read as follows:
R302.2.3 Continuity. The fire-resistance-rated common wall or assembly separating
townhouses units along property lines shall be continuous from the foundation to the
underside of the roof sheathing, deck or slab. The fire-resistance rating shall extend the
full length of the wall or assembly, including wall extensions through and separating
attached and/or enclosed accessory structures or spaces. The fire-resistance-rating shall
be maintained within concealed spaces of projecting elements such as, roof overhangs,
canopies, marquees and similar projections. The fire-resistant rated adjoining walls
shall extend to the outer edge of horizontal projecting elements such as balconies that
extend more than 24 inches beyond the exterior wall.
23. Section R302.3 Two-family dwellings is hereby amended to read as follows:
R302.3 Two-family dwellings. Two-family dwellings shall be provided with a fire-
suppression system as per P2904 at a minimum. Dwelling units in two-family dwellings
shall be separated from each other by wall and/or floor assemblies having not less than
a one-hour fire-resistance rating when tested in accordance with ASTM E119 or UL
263 or Section 703.2.2 of the International Building Code. Such separation shall be
provided regardless of whether a lot line exists between the two dwelling units or not.
Fire-resistance-rated floor/ceiling and wall assemblies shall extend to and be tight
against the exterior wall, and wall assemblies shall extend from the foundation to the
underside of the roof sheathing.
Exceptions:
1. A fire-resistance rating of 1/2 hour shall be permitted in buildings equipped
throughout with an automatic sprinkler system installed in accordance with
Section P2904.
2. Wall assemblies need not extend through attic spaces where the ceiling is
protected by not less than 5/8-inch (15.9 mm) Type X gypsum board, an
attic draft stop constructed as specified in Section R302.12.1 is provided
above and along the wall assembly separating the dwellings and the
structural framing supporting the ceiling is protected by not less than 1/2-
inch (12.7 mm) gypsum board or equivalent.
24. Section R308.4.7 Glazing adjacent to the bottom stair landing is hereby amended to
read as follows (Figure R308.4.7 is retained):
R308.4.7 Glazing adjacent to stair landings. Glazing adjacent to stair landings where
the glazing is less than 36 inches (914 mm) above the landing and within a 60-inch
(1524 mm) horizontal arc less than 180 degrees (3.14 rad) from the top or bottom tread
nosing shall be considered a hazardous location. (See Figure R308.4.7.)
Exception: Where the glazing is protected by a guard complying with Section
R312 and the plane of the glass is more than 18 inches (457 mm) from the guard.
25. Section R310.1 Emergency escape and rescue opening required is hereby amended
to read as follows:
R310.1 Emergency escape and rescue opening required Basements, habitable attics,
habitable lofts and mezzanines, and every sleeping room shall have not less than one
operable emergency escape and rescue opening. Where basements contain one or more
sleeping rooms, an emergency escape and rescue opening shall be required in each
sleeping room. Emergency escape and rescue openings shall open directly into a public
way, or to a yard or court having a minimum width of 36 inches (914 mm) that opens
to a public way.
Exceptions:
1. Storm shelters and basements used only to house mechanical equipment not
exceeding a total floor area of 200 square feet (18.58 m2).
2. A yard shall not be required to open directly into a public way where the yard
opens to an unobstructed path from the yard to the public way. Such path
shall have a width of not less than 36 inches (914 mm).
26. Section R310.1.1 Operational constraints and opening control devices is amended
to read as follows:
R310.1.1 Operational constraints and opening control devices. Emergency escape
and rescue openings shall be operational from the inside of the room without the use
of keys, tools or special knowledge.
27. Section R310.2.3 Maximum height from floor is amended to read as follows:
R310.2.3 Maximum height from floor. Emergency escape and rescue openings shall
have the bottom of the clear opening not greater than 44 inches (1118 mm) above the
floor. Emergency escape and rescue window openings that are located more than 72
inches (1829 mm) above the finished grade shall have a sill height of not less than 24
inches (609 mm) measured from the finished interior side floor.
28. Section R311.7.5.1 Risers is hereby amended to read as follows:
R311.7.5.1 Risers. The riser height shall be not more than 7 3/4 inches (196 mm). The
minimum riser height shall be not less than 4 inches (102 mm). The riser height shall
be measured vertically between leading edges of the adjacent treads. The greatest riser
height within any flight of stairs shall not exceed the smallest by more than 3/8 inch
(9.5 mm). Risers shall be vertical or sloped from the underside of the nosing of the
tread above at an angle not more than 30 degrees (0.51 rad) from the vertical. At open
risers, openings located more than 30 inches (762 mm), as measured vertically, to the
floor or grade below shall not permit the passage of a 4-inch-diameter (102 mm)
sphere.
29. Section R313.2 One- and two-family dwellings automatic sprinkler systems is
amended to read as follows:
R313.2 Two-family dwellings automatic fire systems. An automatic residential fire
sprinkler system shall be installed in two-family dwellings.
Exception: An automatic sprinkler system shall not be required for additions or
alterations to existing buildings that are not already provided with a sprinkler
system.
30. Section R314.2.2 Alterations, repairs and additions is amended by deleting
exception #2.
31. Section R314.4 Interconnection is amended to add an exception to read as follows:
R314.4 Interconnection. Where more than one smoke alarm is required to be installed
within an individual dwelling unit in accordance with Section R314.3, the alarm
devices shall be interconnected in such a manner that the actuation of one alarm will
activate all of the alarms in the individual dwelling unit. Physical interconnection of
smoke alarms shall not be required where listed wireless alarms are installed and all
alarms sound upon activation of one alarm.
Exception: Interconnection of smoke alarms in existing areas shall not be required
where install would require the removal of interior wall or ceiling finishes, unless
there is an attic, crawl space, or basement available to could provide access for
interconnection without the removal if interior finishes.
32. Section R315.2.2 Alterations, repairs and additions is hereby amended to read as
follows:
R315.2.2 Alterations, repairs and additions. Where alterations, repairs or additions
requiring a permit occur, or where one or more sleeping rooms are added or created in
existing dwellings, the individual dwelling unit shall be equipped with carbon
monoxide alarms located as required for new dwellings.
33. Section R320.1 Scope is hereby amended to read as follows:
R320.1 Scope. Where there are four or more dwelling units or sleeping units in a single
structure, the applicable provisions of C.R.S. § 9-5-101 et. seq., and the provisions of
Chapter 11 of the adopted International Building Code for Group R-3 shall apply.
Nothing in this Section shall abrogate or otherwise modify an owner’s duties or
responsibilities under the Americans with Disabilities Act or any other federal law or
regulation regarding accessibility.
34. A new Section R320.3 Visitability is hereby added to read as follows:
R320.3 Visitability. A new dwelling unit with habitable space on the first story shall
designate at least one bathroom group or half bath on the first story that must be
designed and constructed to meet the visitability requirements of this section.
R320.3.1 Bathrooms within dwelling units. A bathroom group or half bath
designated for visitability must have a minimum clear opening of 30 inches.
R320.3.2 Wall reinforcement. A bathroom group or half bath designated for
visitability must have reinforced walls that meet the following standards:
1. Lateral two-inch by six-inch or larger nominal wood blocking must be installed
flush with stud edges of bathroom walls; and
2. The centerline of the blocking must be 34 inches from and parallel to the interior
floor level.
Exception:
Blocking is not required in the portion of the wall located directly behind
the lavatory.
R320.3.3 Lighting and environmental controls. Light switches, receptacles and
other environmental controls located in a bathroom or a half bath designated for
visitability must be no higher than 48 inches above the interior floor level. Receptacles
shall be a minimum of 15 inches above the interior floor level.
R320.3.4 Visitability routes within the dwelling unit. A bathroom group or half bath
designated for visitability must be visitable by a route through the living room, dining
room, and kitchen that provides a minimum clear width of 32 inches, and any interior
doors on the route must have lever handles.
35. SECTION R322 FLOOD-RESISTANT CONSTRUCTION is hereby deleted in its
entirety and amended to read as follows:
SECTION R322
FLOOD-RESISTANT CONSTRUCTION
R322.1 General. Buildings and structures constructed in whole or in part in flood
hazard areas shall be designed and constructed in accordance with the provisions of the
City Code, Chapter 10, Flood Prevention and Protection. In riverine flood hazard areas
where design flood elevations are specified but floodways have not been designated,
the applicant shall demonstrate that the cumulative effect of the proposed buildings and
structures on design flood elevations, including fill, when combined with all other
existing and anticipated development, will not increase the design flood elevation more
than one foot at any point within the City.
36. A new SECTION R331 RESOURCE EFFICIENCY is hereby added to read as
follows:
SECTION R331 RESOURCE EFFICIENCY
R331.1 Construction waste management. For remodels and additions over 2,500
square feet, and for all new buildings, a construction waste management plan
acceptable to the building official is required at the time of application for a building
permit. The construction waste management plan shall be implemented and
conspicuously posted on the construction site. All concrete, asphalt, masonry, wood,
metals, and cardboard shall be recycled. All mixed construction and demolition
materials (as defined in § 12-16 of the City Code) shall be delivered to any facility
identified in and disposed of in accordance with § 12-22(c) of the City Code.
Compliance shall be certified by inspection and documentation and signed final
construction waste management plans. Substantive changes to the plan shall be subject
to prior approval by the building official. All roofing permits are required to submit a
final waste management plan and documentation.
R331.1.1 Building demolitions. Buildings or portions of buildings that are removed
shall be processed in such a way as to safely remove all asbestos and lead paint
contaminants. For all demolitions, excluding non-structural demolitions under 1000
square feet a demolition waste management plan acceptable to the building official is
required at the time of application for a demolition permit. All metals, asphalt, concrete,
and masonry that are free of asbestos and lead paint shall be recycled, and where
possible, all remaining materials, such as doors, windows, cabinets, fixtures, and wood,
shall be recycled. All mixed construction and demolition materials (as defined in § 12-
16 of the City Code) shall be delivered to any facility identified in and disposed of in
accordance with § 12-22(c) of the City Code. Compliance shall be certified by
inspection, documentation, and signed final demolition waste management plans.
Substantive changes to the plan shall be subject to prior approval by the building
official.
R331.2 Exterior lighting. All exterior lighting fixtures shall be down directional and
fully shielded luminaires and shall have a nominal correlated color temperature (CCT)
of no greater than 3000 Kelvin.
R331.3 Operations and maintenance. In new buildings, operation and maintenance
information addressing all installed systems shall be provided to the building owner.
R331.4 Electrical Vehicle Ready. All new single family dwellings with an attached
garage or carport shall be provided one continuous 40-amp, 208/240-Volt dedicated
branch circuit for electric vehicle supply equipment that is terminated at a receptacle or
electric vehicle supply equipment.
Exception: In cases where a transformer upgrade is required.
37. Section R401.1 Application is hereby amended to read as follows:
R401.1 Application. The provisions of this chapter shall control the design and
construction of the foundation and foundation spaces for all buildings. In addition to
the provisions of this chapter, the design and construction of foundations in areas prone
to flooding shall meet the provisions of Section R322. All foundations shall be designed
by a qualified professional licensed in the State of Colorado. Such designs shall be
performed in accordance with accepted and approved engineering practices, including
considerations for soil load-bearing capacities, surface and subsurface water
conditions, adequate foundation and floor drainage, adequate ventilation of enclosed
interior foundation spaces, and foundation waterproofing and damp-proofing. Final
engineer’s reports, indicating their acceptance of the above requirements, shall be
submitted to the building official prior to the issuance of the Certificate of Occupancy.
Wood foundations shall be designed and installed in accordance with AWC PWF.
Exceptions:
1. Foundations for non-habitable detached accessory buildings.
2. The provisions of this chapter shall be permitted to be used for wood
foundations only in the following situations: a. In buildings that have no more than two floors and a roof.
b. When interior basement and foundation walls are constructed at
intervals not exceeding 50 feet (15 240 mm).
Wood foundations in Seismic Design Category D0, D1 or D2 shall be designed
in accordance with accepted engineering practice.
38. A new Section R401.5 Placement of Backfill is hereby added to read as follows:
R401.5 Placement of Backfill. The excavation outside the foundation, including utility
trenches and excavation ramp, shall be backfilled with soil that is substantially free of
organic material, construction debris and cobbles, boulders, and solid soil masses larger
than 6 inches (152 mm) diameter; or of frozen soil. The backfill shall be placed in lifts
and compacted as set forth in the engineering documents. The backfill shall be placed
in a manner that does not damage the foundation or the waterproofing or damp-proofing
material. Excavation ramps shall be backfilled in such a manner that the ramp does not
become a conduit for surface water to flow toward the foundation. Where excavations
include more than one structure, a specially engineered drainage system may be
required by the building official.
39. Section R405.1 Concrete or masonry foundations is hereby amended to read as
follows (Table R405.1 is retained in its entirety):
R405.1 Concrete or masonry foundations. Drains consisting of piping conforming
with ASTM Designation D2729- 89 shall be provided adjacent to the lowest concrete
or masonry foundations that retain earth and enclose spaces that are partially or entirely
located below grade. Unless perimeter drains are designed to daylight, they shall
terminate in sump pits with an electrical power source permanently installed within 36
inches (914 mm) of the sump opening. Piping for sump pumps shall discharge at least
60 inches (1524 mm) away from foundations, or as otherwise approved by the building
official. Drains shall be installed in bedding materials that are of such size and installed
in such manner to allow ground water to seep into the perimeter drain. Filter fabric or
other measures to restrict the passage of fines shall be used to further protect the
perimeter drain from blockage.
Exception:
A drainage system is not required where it has been determined by the engineer
of record that the foundation is installed on well-drained ground or sand gravel
mixture soils according to the Unified Soil Classification System, Group I Soils,
as detailed in Table R405.1.
40. A new Section R405.3 Landscape irrigation is added to read as follows:
R405.3 Landscape irrigation. Landscape irrigation systems, other than drip systems,
shall be installed such that the ground surface within 60 inches (1524 mm), measured
perpendicular from the foundation, is not irrigated.
41. Section R408.2 Openings for under-floor ventilation is hereby amended to read as
follows:
R408.2 Underfloor ventilation. Underfloor ventilation shall be provided per Section
R408.3 except where high groundwater conditions exist that would require a vented
under-floor space (“cold crawl”), ventilation openings through foundation or exterior
walls surrounding the under-floor space shall be provided in accordance with this
section. The minimum net area of ventilation openings shall be not less than 1 square
foot (0.0929 m2) for each 150 square feet (14 m2) of under-floor area. One ventilation
opening shall be within 3 feet (915 mm) of each external corner of the under-floor
space. Ventilation openings shall be covered for their height and width with any of the
following materials provided that the least dimension of the covering shall not exceed
1/4 inch (6.4 mm), and operational louvers are permitted:
1. Perforated sheet metal plates not less than 0.070 inch (1.8 mm) thick.
2. Expanded sheet metal plates not less than 0.047 inch (1.2 mm) thick.
3. Cast-iron grill or grating.
4. Extruded load-bearing brick vents.
5. Hardware cloth of 0.035 inch (0.89 mm) wire or heavier.
6. Corrosion-resistant wire mesh, with the least dimension being 1/8 inch (3.2 mm)
thick.
Exceptions:
1. The total area of ventilation openings shall be permitted to be reduced to
1/1,500 of the under-floor area where the ground surface is covered with
an approved Class I vapor retarder material.
2. Where the ground surface is covered with an approved Class 1 vapor
retarder material, ventilation openings are not required to be within 3
feet (915 mm) of each external corner of the underfloor space provided
that the openings are placed to provide cross ventilation of the space.
42. A new Section R408.3.1 Spaces under below-grade floors is hereby added to read as
follows:
R408.3.1 Spaces under below-grade floors. Mechanical ventilation systems for
spaces under below-grade floors shall be designed by a professional engineer and
installed in accordance with such designs or a mechanical ventilation system for spaces
under below-grade floors shall be provided with an active, fan assisted submembrane
depressurization system installed per IRC APPENDIX AF, RADON CONTROL
METHODS. In addition, the space above the soil-gas-retarder and below the floor shall
be provided with continuously operated mechanical exhaust ventilation at a rate equal
to 1 cubic foot per minute for each 50 square feet of under floor area and either
mechanical supply air at the same rate, or an air pathway (such as a duct or transfer
grille) to the common area that is not located in rooms containing open combustion fuel
burning appliances.
43. Section R702.7 Vapor retarders is hereby amended to read as follows:
R702.7 Vapor retarders. Vapor retarder materials shall be classified in accordance
with Table R702.7(1). A vapor retarder may be provided on the interior side of frame
walls of the class indicated in Table R702.7(2), including compliance with Table
R702.7(3) or R702.7(4) where applicable. Class I vapor retarders are not allowed on basement
foundation walls or any concrete or masonry below grade wall. An approved design using
accepted engineering practice for hygrothermal analysis shall be permitted as an
alternative. The climate zone shall be determined in accordance with IECC Section
R301.1.
Exceptions:
1. Construction where accumulation, condensation or freezing of moisture will
not damage the materials.
2. A vapor retarder shall not be required in Climate Zones 1, 2 and 3.
44. TABLE R702.7(2) VAPOR RETARDER OPTIONS is amended to read as follows:
TABLE R702.7(2) VAPOR RETARDER OPTIONS
CLIMATE ZONE VAPOR RETARDER CLASS
CLASS Ia CLASS IIa CLASS IIIa
Marine 4, 5, 6, 7, 8 Permittedb Permittedc Permitted
a. Vapor retarders with vapor permeance greater than 1 perm when measured by ASTM E96 water method (Procedure B) shall be
allowed on the interior side of any frame wall.
b. Use of a Class I interior vapor retarder in frame walls with a Class I vapor retarder on the exterior side shall require an approved
design.
c. Where a Class II vapor retarder is used in combination with foam plastic insulating sheathing installed as continuous insulation on
the exterior side of frame walls, the continuous insulation shall comply with Table R702.7(4) and the Class II vapor retarder shall
have a vapor permeance greater than 1 perm when measured by ASTM E96 water method (Procedure B).
45. A new Section R703.11.3 Vinyl siding and soffits on new buildings is hereby added
to read as follows:
Section R703.11.3 Vinyl siding and soffits on new buildings. Vinyl siding and soffits
on new buildings shall be installed over one-hour fire-rated assemblies listed for
exterior fire exposure, in both the vertical and horizontal plane.
46. A new Section R703.13.2 Insulated vinyl siding and soffits on new buildings is
hereby added to read as follows:
Section R703.13.2 Insulated vinyl siding and soffits on new buildings. Insulated
vinyl siding and soffits on new buildings shall be installed over one-hour fire-rated
assemblies listed for exterior fire exposure, in both the vertical and horizontal plane.
47. Section R703.14.1.1 Installation is hereby amended to read as follows:
Section R703.14.1.1 Installation. Polypropylene siding on new buildings shall be
installed over one-hour fire-rated assemblies listed for exterior fire exposure, in both
the vertical and horizontal plane. Polypropylene siding shall be installed over and
attached to wood structural panel sheathing with minimum thickness of 7/16 inch (11.1
mm), or other substrate, composed of wood or wood-based material and fasteners
having equivalent withdrawal resistance.
48. Section R902.1 Roofing Covering Materials is hereby deleted in its entirety and
replaced with the following:
R902.1 Roofing covering materials. Except as otherwise allowed, roofs shall be
covered with materials listed as Class A and with materials as set forth in Sections
R904 and R905. Classes A, B and C roofing required to be listed by this section must
be tested in accordance with UL 790 or ASTM E 108. Roof assemblies with coverings
of brick, masonry, slate, clay or concrete roof tile, exposed concrete roof deck, ferrous
or copper shingles or sheets, and metal sheets and shingles, shall be considered Class
A roof coverings.
Exception: Any Class B or Class C roof covering may be applied on any new
construction that is added to an existing building, provided the roof extremities of such
existing building and new construction are located a minimum distance of 5 feet (1.524
m) from the nearest adjacent property line and are a minimum distance of 10 feet (3.048
m) from another building.
49. In Section R905.1.2 Ice barriers is retained in its entirety, and a new Exception #2 is
hereby added to read as follows:
. . .
Exceptions:
1. Detached accessory structures not containing conditioned floor area.
2. Re-roofing where the existing roof covering has not been removed.
50. Section R905.2.1 Sheathing requirements is hereby amended to read as follows:
R905.2.1 Sheathing requirements. Asphalt shingles shall be fastened to solidly
sheathed decks. Gaps in the solid decking shall not exceed 1/8 inch.
51. A new Section R905.2.4.2 Impact resistance of asphalt shingles is hereby added to
read as follows:
R905.2.4.2 Impact resistance of asphalt shingles. Asphalt shingles shall be Class 4
impact resistant and be tested in accordance with UL 2218 and installed in accordance
with the manufacturer’s installation instructions.
Exceptions:
1. When existing asphalt shingles are less than class 4 impact resistant, and the
owner wishes to replace the existing asphalt shingles with tiles of a similar
color or tile, and there are no class 4 impact resistance shingles available
that are similar color or style of the existing asphalt shingles, the building
official may approve alternate materials that are less than class 4 impact
resistant; however, the building official will impose the highest class of
impact resistance that are available that match the color or style of the
existing asphalt shingles. If no impact resistant materials are available, the
building official may approve non-impact resistant materials if the alternate
materials meet all other applicable requirements of this code.
2. When the owner is repairing or adding to existing asphalt singles that are
less than class 4 impact resistant, the owner may use the same or similar
materials as the current existing asphalt shingles, even if that same or similar
material is not impact resistant.
52. Section R908.1 General is hereby amended to read as follows:
R908.1 General. Materials and methods of application used for recovering or replacing
an existing roof covering shall comply with the requirements of Chapter 9.
Exceptions:
1. Reroofing shall not be required to meet the minimum design slope
requirement of one-quarter unit vertical in 12 units horizontal (2-percent
slope) in Section R905 for roofs that provide positive roof drainage.
2. For roofs that provide positive drainage, recovering or replacing an existing
roof covering shall not require the secondary (emergency overflow) drains
or scuppers of Section R903.4.1 to be added to an existing roof.
3. Any existing roof covering system may be replaced with a roof covering of
the same materials and classification, provided the replacement roof
covering has a minimum rating of Class C.
53. Section R1004.1 General is hereby amended to read as follows:
R1004.1 General. Factory-built fireplaces shall be listed and labeled and shall be
installed in accordance with the conditions of the listing. Factory-built fireplaces shall
be tested in accordance with UL 127. Solid fuel fireplaces, fireplace stoves and solid-
fuel-type room heaters also shall comply with §5-110 of the City Code and must be
installed with a spark arrestor.
54. Section R1004.4 Unvented Gas log Heaters is here by deleted in its entirety.
55. Chapter 11 [RE] ENERGY EFFICIENCY is hereby deleted in its entirety and all
provisions for ENERGY EFFICIENCY shall comply with the currently adopted
International Energy Conservation Code, IECC--RESIDENTIAL PROVISIONS and
its local amendments because the language of this chapter is duplicated within the IECC
RESIDENTIAL PROVISIONS.
56. A new SECTION M1309 TESTING AND VERIFICATION is hereby added to read
as follows:
SECTION M1309 TESTING AND VERIFICATION.
M1309.1 General. Installed heating, cooling and ventilation systems shall be
performance-tested and adjusted per the Residential New Construction Mechanical
Systems Testing Guide as currently adopted by the City of Fort Collins and to operate
within design specifications, in accordance with ANSI/ACCA QI 5-2010 HVAC
Quality Installation Specification. Documentation of results must be submitted to the
building official prior to the issuance of the certificate of occupancy.
57. Section M1401.3 Equipment and appliance sizing is hereby deleted in its entirety
and replaced with the following:
M1401.3 Heating and cooling system design. The design of new heating and cooling
systems shall meet the requirements of this section. Design documents shall be
submitted to the building official at the time of application for a building permit.
M1401.3.1 Equipment and appliance sizing. Heating and cooling equipment and
appliances shall be sized in accordance with ACCA Manual S, based on design
building loads calculated in accordance with ACCA Manual J, or other equivalent
methodology approved by the building official, using thermal design parameters in
Table R301.2 as amended. The total equipment or appliance output capacity shall be
between the following limits, as applicable for the equipment type:
1. 95% and 115% of calculated system cooling load, for air conditioners and heat
pumps;
2. 95% and 125% of calculated system cooling load, for heat pumps with winter
heating dominated requirements;
3. 100% and 140% of calculated system heating load, for warm air systems, unless
dictated by the cooling equipment selection; and
4. 100% and 115% of calculated system heating load, for heating boilers.
When there is no equipment available to satisfy these applicable capacity limits, the
next largest nominal piece of equipment that is available may be used.
M1401.3.2 Room loads. Room-by-room design heating and cooling loads shall be
calculated.
M1401.3.3 Matched components. Air-conditioning, Heating and Refrigeration
Institute (AHRI) matched evaporators, condensing units and air handlers shall be
required.
58. A new Section, M1402.4 Total Electric Heating is hereby added to read as follows:
M1402.4 Total Electric Heating. Primary indoor central heating systems utilizing
only electric heat shall utilize a ground source heat pump system(s) or cold climate heat
pump system(s) specifically designed to heat in cold climates and at the Winter
Outdoor, Design Dry-Bulb temp defined in IECC Section C301.5. The heat pump
system shall not be gas or propane fuel fired. Electric resistance strip heat shall only
serve as emergency back-up heat or supplemental heat at outdoor temperatures below
15o F as necessary.
59. Section, M1414.1 General is hereby amended to read as follows:
M1414.1 General. Fireplace stoves shall be listed, labeled and installed in accordance
with the terms of the listing. Fireplace stoves shall be tested in accordance with UL
737. Wood burning appliances shall meet the latest emission standards as required by
the State of Colorado and Federal Regulation 40 CFR Part 60, Subpart AAA.
60. A new Section M1501.2 Indoor depressurization is hereby added to read as follows:
M1501.2 Indoor depressurization. Ducted exhaust systems shall not induce or create
a negative pressure sufficient to cause back-drafting of naturally vented, open
combustion-chamber or fuel-burning appliances, nor create negative pressure in excess
of negative 3 Pa. in the immediate proximity of combustion chambers of such
appliances.
61. Section M1502.4.2 Duct installation is amended to read as follows:
M1502.4.2 Duct installation. Exhaust ducts shall be supported at intervals not to
exceed 12 feet (3658 mm) and shall be secured in place. The insert end of the duct shall
extend into the adjoining duct or fitting in the direction of airflow. Exhaust duct joints
shall be sealed in accordance with Section M1601.4.1 and shall be mechanically
fastened. Ducts shall not be joined with screws or similar fasteners. Where dryer
exhaust ducts are enclosed in wall or ceiling cavities, such cavities shall allow the
installation of the duct without deformation.
62. Section M1505.4 Whole-house mechanical ventilation system is hereby deleted in
its entirety and replaced with the following:
M1505.4 Whole-dwelling unit mechanical ventilation system. For new dwellings, a
mechanical exhaust system, supply system, or combination thereof shall be installed
for each dwelling unit to provide whole-dwelling unit ventilation. Such system shall
comply with Sections M1505.4.1 through M1505.4.4. System design documents must
be submitted to the building official at the time of application for a building permit.
63. Section M1601.1 Duct design is hereby amended to read as follows:
M1601.1 Duct design. Duct systems serving heating, cooling and ventilation
equipment in new buildings, or new duct systems in additions, shall be designed and
fabricated in accordance with the provisions of this section and ACCA Manual D or
other approved methods.
64. In Section M1601.1.1 Above-ground duct systems, Items 7 through 7.6 are hereby
deleted in their entirety.
65. A new Section M1601.4.11 Construction debris and contamination is hereby added
to read as follows:
M1601.4.11 Construction debris and contamination. Mechanical air-handling
systems and their related ducts shall be protected from the entrance of dirt, debris, and
dust during the construction and installation process. Prior to passing final inspection or
issuance of a certificate of occupancy, such systems shall be substantially free of
construction-related contaminants.
66. Section M1602.2 Return Air Openings is hereby amended to read as follows:
M1602.2 Return Air Openings. A return air path shall be provided in all habitable
rooms by means of ducts or transfer grills. Return air openings for heating, ventilation
and air conditioning systems shall comply with all of the following:
1. Openings shall not be located less than 10 feet (3048 mm) measured in any
direction from an open combustion chamber or draft hood of another appliance
located in the same room or space.
2. The amount of return air taken from any room or space shall be not greater than
the flow rate of supply air delivered to such room or space.
3. Return and transfer openings shall be sized in accordance with the appliance or
equipment manufacturer’s installation instructions, Manual D or the design of
the registered design professional.
4. Return air shall not be taken from a closet, bathroom, toilet room, kitchen,
garage, mechanical room, boiler room, furnace room or unconditioned attic.
Exceptions:
1. Taking return air from a kitchen is not prohibited where such return air
openings serve the kitchen only, and are located not less than 10 feet
(3048 mm) from the cooking appliances.
2. Dedicated forced-air systems serving only the garage shall not be
prohibited from obtaining return air from the garage.
5. For other than dedicated HVAC systems, return air shall not be taken from
indoor swimming pool enclosures and associated deck areas except where the
air in such spaces is dehumidified.
6. Taking return air from an unconditioned crawl space shall not be accomplished
through a direct connection to the return side of a forced-air furnace. Transfer
openings in the crawl space enclosure shall not be prohibited.
7. Return air from one dwelling unit shall not be discharged into another dwelling
unit.
67. Section G2404.3 (301.3) Listed and labeled is hereby amended to read as follows:
G2404.3 (301.3) Listed and labeled. Appliances regulated by this code shall be listed
and labeled for the application in which they are used unless otherwise approved in
accordance with Section R104.11.
68. Section G2406.2 (303.3) Prohibited locations is hereby amended by only deleting the
exceptions in Items #3 and #4.
69. Section G2407.11 (304.11) Combustion air ducts is hereby amended by only adding
a new Item #9 to read as follows:
9. All combustion air openings or ducts shall be readily identifiable with an approved
label or by other means warning persons that obstruction of such openings or ducts may
cause fuel-burning equipment to release combustion products and dangerous levels of
carbon monoxide into the building.
70. Section G2415.12 (404.12) Minimum burial depth is hereby amended to read as
follows:
G2415.12 (404.12) Minimum burial depth. Underground piping systems shall be
installed a minimum depth of 18 inches below grade.
71. Section G2415.12.1 (404.12.1) Individual outside appliance is hereby deleted in its
entirety.
72. Section G2417.4.1 (406.4.1) Test pressure is hereby deleted in its entirety and
replaced with the following:
G2417.4.1 (406.4.1) Test pressure. The test pressure to be used for non-welded pipe
shall be 10 psi minimum.
73. Section G2425.8 (501.8) Appliances not required to be vented is hereby amended to
read as follows:
G2425.8 (501.8) Appliances not required to be vented. The following appliances
shall not be required to be vented:
1. Electric ranges.
2. Electric built-in domestic cooking units listed and marked for optional venting.
3. Hot plates and laundry stoves.
4. Type 1 clothes dryers (Type 1 clothes dryers shall be exhausted in accordance
with the requirements of Section G2439).
5. Refrigerators.
6. Counter appliances.
74. Section G2427.6.5 (503.6.5) Minimum height is hereby amended to read as follows:
G2427.6.5 (503.6.6) Minimum height. A Type B or L gas vent shall terminate not less
than 5 feet (1524 mm) in vertical height above the highest connected appliance draft
hood or flue collar. A Type B-W gas vent shall terminate at least 12 feet (3658 mm) in
vertical height above the bottom of the wall furnace. All gas vents shall terminate a
minimum of 22 inches (559 mm) above the surface or grade directly below.
75. SECTION G2445 (621) UNVENTED ROOM HEATERS is hereby deleted in its
entirety.
76. A new Section G2447.6 (623.8) Gas cooking appliances is hereby added to read as
follows:
G2447.6 Gas cooking appliances. Gas cooking appliances shall be supplied with an
exhaust system vented to the outside in accordance with section M1503. Ducts serving
gas appliance exhaust systems shall not terminate in an attic or crawl space or areas
inside the building, shall not induce or create negative pressure in excess of negative 3
Pa, nor shall they adversely affect gravity-vented appliances.
77. A new Section G2451.3 (630.3) Combustion and ventilation air is hereby added to
read as follows:
G2451.3 (630.3) Combustion and ventilation air. Where infrared heaters are
installed, natural or mechanical means shall provide outdoor ventilation air at a rate of
not less than 4 cfm per 1,000 Btu/h (0.38 m3/min/kW) of the aggregate input rating of
all such heaters installed in the space. Outdoor exhaust openings for removing flue
products shall terminate above the level of the heaters.
78. Section P2503.5.1 Rough Plumbing is hereby amended to read as follows:
P2503.5.1 Rough plumbing. DWV systems shall be tested on completion of the rough
piping installation by water, by air, or by a vacuum, without evidence of leakage. The
test shall be applied to the drainage system in its entirety or in sections after rough-in
piping has been installed, as follows:
1. Water test. Each section shall be filled with water to a point not less than 10
feet (3048 mm) above the highest fitting connection in that section, or to the
highest point in the completed system. Water shall be held in the section under
test for a period of 15 minutes. The system shall prove leak free by visual
inspection.
2. Air test. The portion under test shall be maintained at a gauge pressure of 5
pounds per square inch (psi) (34 kPa) or 10 inches of mercury column (34 kPa).
This pressure shall be held without introduction of additional air for a period of
15 minutes.
3. Vacuum test. The portion under test shall be evacuated of air by a vacuum-type
pump to achieve a uniform gauge pressure of -5 pounds per square inch or a
negative 10 inches of mercury column (-34 kPa). This pressure shall be held
without the removal of additional air for a period of 15 minutes.
79. Section P2903.2 Maximum flow and water consumption is hereby amended to read
as follows:
P2903.2 Maximum flow and water consumption. The maximum water consumption
flow rates and quantities for all plumbing fixtures and fixture fittings shall be in
accordance with Table P2903.2, and shall be Environmental Protection Agency (EPA)
WaterSense® labeled fixtures, except for fixture types that are not labeled under the
WaterSense® program.
80. TABLE P2903.2 MAXIMUM FLOW RATES AND CONSUMPTION FOR
PLUMBING FIXTURES AND FIXTURE FITTINGSb is hereby deleted in its
entirety and amended to read as follows:
TABLE P2903.2
MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING
FIXTURES AND FIXTURE FITTINGSb
For SI: 1 gallon per minute = 3.785 L/m, 1 pound per square inch = 6.895 kPa.
a. A hand-held shower spray shall be considered to be a shower head.
b. Consumption tolerances shall be determined from referenced standards.
c. In existing buildings not increasing the building size, a 1.28 gpf maximum water closet is allowed.
81. APPENDIX AE MANUFACTURED HOUSING USED AS DWELLINGS is
hereby adopted in its entirety.
82. APPENDIX AF RADON CONTROL METHODS is hereby adopted in its entirety,
with the following amendments:
Section AF101.1 General is hereby amended to read as follows:
AF101.1 General. Radon-resistant construction is required for all new dwellings
constructed under this code as prescribed in this Appendix.
Section AF103.1 General is hereby amended is read as follows:
AF103.1 General. The following construction techniques are intended to resist radon
entry and prepare the building for post-construction radon mitigation.
Section AF103.2 Subfloor preparation is hereby amended to read as follows:
AF103.2 Subfloor preparation. A layer of gas-permeable material may be placed
under all concrete slabs and other floor systems that directly contact the ground and are
within the walls of the living spaces of the building, to facilitate future installation of a
PLUMBING FIXTURE OR
FIXTURE FITTING
MAXIMUM FLOW RATE OR QUANTITY
Lavatory faucet 1.5 gpm at 60 psi
Shower heada 1.8 gpm at 80 psi
Sink faucet 1.8 gpm at 60 psi
Water closet 1.1 gallons per flushing cycle, with minimum
MaP threshold of 600 grams. Dual flush
gallons per flushing cycle: Average of three
flushes (two reduced flushes and one full
flush).c
subslab depressurization system, if needed. Each radon reduction vent pipe riser shall
serve no more than 4,000 square feet of uninterrupted under slab/floor area. The gas-
permeable layer shall consist of one of the following:
1. A uniform layer of clean aggregate, not less than 4 inches (102 mm) thick. The
aggregate shall consist of material that will pass through a 2-inch (51 mm) sieve
and be retained by a 1/4-inch (6.4 mm) sieve.
2. A uniform layer of sand (native or fill), not less than 4 inches (102 mm) thick,
overlain by a layer or strips of geotextile drainage matting designed to allow
the lateral flow of soil gases.
3. Other materials, systems or floor designs with demonstrated capability to permit
depressurization across the entire subfloor area.
Section AF103.3 Soil-gas-retarder is hereby deleted in its entirety and replaced with
the following:
AF103.3 Soil-gas-retarder. The soil in crawl spaces shall be covered with a
continuous layer of a minimum 6-mil (0.15 mm) polyethylene or 3 mil (0.75 mm)
cross-laminated polyethylene soil-gas-retarder. The ground cover shall be lapped not
less than 12 inches at joints and sealed or taped. The edges of the ground cover shall
extend a minimum of 12 inches (152 mm) up onto all foundation walls enclosing the
under-floor space and be sealed to the wall and any footing pads. 6-mil polyethylene
also shall be sealed and mechanically fastened to the wall. An interior perimeter drain
tile loop shall be connected to a plumbing tee or other approved connection as per
AF103.5.3.
Section AF103.5 Passive submembrane depressurization system is hereby amended
to read as follows:
AF103.5 Passive submembrane depressurization system. In buildings with crawl
space foundations, the following components of a passive submembrane
depressurization system shall be installed during construction.
Section AF103.5.1 Ventilation is hereby deleted in its entirety.
A new Section AF103.13 Provisions for future depressurization fan installation is
hereby added to read as follows:
AF103.13 Provisions for future depressurization fan installation. Permanent
provisions shall be made for the future installation of an in-line fan to be connected to
every radon vent pipe. Such designated fan locations shall be outside of the conditioned
envelope of the building, such as in the attic, garage and similar locations, excluding
crawl spaces and other interior under-floor spaces. Designated locations shall
accommodate an unobstructed permanent cylindrical space with the following
minimum dimensions: 12 inches (305 mm) measured radially around the radon vent
pipe along a vertical distance of 30 inches (760 mm). Designated fan locations shall be
permanently accessible for servicing and maintenance. An electrical receptacle outlet
shall be provided within 4 feet (1.219 m) of and within sight from designated fan
locations and installed so as to not be covered by insulation. A light fixture shall be
installed in the area of future fan location.
Section AF104.1 Testing is hereby amended by deleting only Item #11 (the
Exception is retained):
83. APPENDIX AH PATIO COVERS is adopted in its entirety.
84. APPENDIX AM HOME DAY-CARE R-3 OCCUPANCIES is adopted in its
entirety.
85. APPENDIX AQ TINY HOUSES is adopted in its entirety.
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
____________________________________
Mayor
ATTEST:
_____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
____________________________________
Mayor
ATTEST:
_____________________________
City Clerk
ORDINANCE NO. 024, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 2 OF THE CODE OF THE
CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE 2018
INTERNATIONAL EXISTING BUILDING CODE AND ADOPTING THE 2021
INTERNATIONAL EXISTING BUILDING CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code, to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes ought to be adopted and that any counterpart International
codes previously adopted should be repealed, both to align the publication years of the codes and
because the 2021 publications contain improvements in construction code regulation; and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resources Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interests of the health,
safety and welfare of the City and its residents that the 2021 International Existing Building Code
be adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in the newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Existing Building
Code (“IEBC”) and hereby adopts the 2021 IEBC as amended by this Ordinance.
Section 3. That Section 5-32 of the Code of the City of Fort Collins is hereby amended
to read as follows:
Sec. 5-32. – Adoption of standards.
Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-16-202
and Article II, Section 7 of the Charter, the City Council has adopted the 2021 International
Existing Building Code, published by the International Code Council, as amended by the
City, which shall have the same force and effect as though set forth in full herein. The
subject matter of the 2021 International Existing Building Code includes comprehensive
provisions and standards regulating and controlling the repair, alteration, change of
occupancy, addition to and relocation of existing buildings for the purposes of protecting
public health, safety and general welfare.
Section 4. That Section 5-33 of the Code of the City of Fort Collins is hereby repealed
and re-enacted to read as follows:
Sec. 5-33. - Amendments and deletions to the 2021 International Existing Building Code.
The 2021 INTERNATIONAL EXISTING BUILDING CODE adopted herein is hereby
amended in the following respects:
1. Section 101.1 Title is hereby amended to read as follows:
101.1 Title. These regulations shall be known as the Existing Building Code of the City of
Fort Collins, hereinafter referred to as “this code.”
2. Section 103.1 Creation of agency is hereby deleted in its entirety and replaced with the
following:
103.1 Entity charged with code administration shall be as determined in accordance
with Section 103 of the adopted International Building Code, entitled “Code
Administration.”
3. Section 104.10.1 Flood hazard areas is hereby deleted in its entirety and replaced with
the following:
104.10.1 Flood hazard areas. For existing buildings or structures regulated under the
scope of this code that are in whole or in part located in flood hazard areas, construction
documents shall be submitted as established in accordance with the Code of the City,
Chapter 10, entitled “Flood Prevention and Protection.”
4. Section 105.3.2 Time limitation of application is hereby amended to read as follows:
105.3.2 Time limitation of application. An application for a permit for any proposed
work shall be deemed to have been abandoned 180 days after the date of filing, unless such
application has been pursued in good faith or a permit has been issued; except that the code
official is authorized to grant one or more extensions of time for additional periods not
exceeding 180 days each. The extension shall be requested in writing and justifiable cause
demonstrated.
6. Section 108.1 Payment of Fees is hereby deleted in its entirety and replaced with the
following:
108.1 Payment of fees. All items relating to fees shall be as specified in Section 109 of
the adopted International Building Code, entitled “Fees.”
7. Section 108.4 Work commencing before permit issuance is hereby deleted in its entirety
and replaced with the following:
108.4 Work commencing before permit issuance. Requirements shall be as determined
in accordance with Section 109.2 of the adopted International Building Code, as amended.
8. Section 112 MEANS OF APPEALS is hereby deleted in its entirety and replaced with
the following:
SECTION 112 MEANS OF APPEALS
Requirements shall be as determined in accordance with Section 113 of the adopted
International Building Code, as amended.
9. Section 113.4 Violation Penalties, is hereby deleted in its entirety and replaced with the
following:
113.4 Violation penalties. Requirements shall be as determined in accordance with
Section 114.4 of the adopted International Building Code, as amended.
10. Section 703.1 Fire Protection-General is hereby amended to read as follows:
703.1 General. Alterations shall be done in a manner that maintains the level of fire
protection required.
11. Section 708.1 Minimum requirements is hereby deleted in its entirety and replaced with
the following:
708.1 Minimum requirements. The scope of work in Level 1 alterations shall conform
to the energy requirements of the International Energy Conservation Code, as amended.
Existing building area not affected by the alteration is not required to comply with the
energy requirements of the International Energy Conservation Code except where the
space undergoes a change of occupancy that would result in an increase in demand for
either fossil fuel or electrical energy per International Energy Conservation Code Sections
C505 or R505.
12. Section 809.1 Minimum requirements is hereby deleted in its entirety and replaced with
the following:
809.1 Minimum requirements. The scope of work in Level 2 alterations shall conform
to the energy requirements of the International Energy Conservation Code, as amended.
Existing building area not affected by the alteration is not required to comply with the
energy requirements of the International Energy Conservation Code except where the
space undergoes a change of occupancy that would result in an increase in demand for
either fossil fuel or electrical energy per International Energy Conservation Code Sections
C505 or R505.
13. Section 907.1 Minimum requirements is hereby deleted in its entirety and replaced with
the following:
907.1 Minimum requirements. The scope of work in Level 3 alterations shall conform
to the energy requirements of the International Energy Conservation Code, as amended.
Existing building area not affected by the alteration is not required to comply with the
energy requirements of the International Energy Conservation Code except where the
space undergoes a change of occupancy that would result in an increase in demand for
either fossil fuel or electrical energy per International Energy Conservation Code Sections
C505 or R505.
14. Section 1103.3 Flood hazard areas is hereby deleted in its entirety and replaced with the
following:
1103.3 Flood hazard areas. For buildings or structures regulated under the scope of this
code that are in whole or in part located in flood hazard areas, construction documents
shall be submitted as established in accordance with Chapter 10 of the City Code, entitled
“Flood Prevention and Protection.”
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
ORDINANCE NO. 025, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 2 OF THE CODE OF THE
CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE 2018
INTERNATIONAL SWIMMING POOL AND SPA CODE AND ADOPTING THE 2021
INTERNATIONAL SWIMMING POOL AND SPA CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code, to the extent as adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both in order to align the publication years of the
codes and because the 2021 publications contain improvements in construction code regulation;
and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the 2021 International Swimming Pool and Spa
Code be adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Swimming Pool and
Spa Code (“ISPSC”) and hereby adopts 2021 ISPSC as amended by this Ordinance.
Section 3. That a new Section 5-34 of the Code of the City of Fort Collins is hereby
amended, to read as follows:
Sec. 5-34. – Adoption of standards.
Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-16-202
and Article II, Section 7 of the Charter, the City Council has adopted the 2021 International
Swimming Pool and Spa Code , published by the International Code Council, as amended
by the City, which shall have the same force and effect as though set forth in full herein.
The subject matter of the 2021 International Swimming Pool and Spa Code adopted
herein includes comprehensive provisions and standards regulating and controlling the
construction, alteration, movement, renovation, replacement, repair and maintenance of
aquatic recreation facilities, pools and spas for the purpose of protecting public health,
safety and general welfare.
Section 4. That Section 5-35 of the Code of the City of Fort Collins is hereby repealed
and re-enacted to read as follows:
The 2021 International Swimming Pool and Spa Code is hereby amended to read as
follows:
Sec. 5-35. Amendments and deletions to the 2021 International Swimming Pool and
Spa Code.
1. Section 101.1 Title is hereby amended as follows:
101.1 Title. These regulations shall be known as the Swimming Pool and Spa Code of
the City of Fort Collins, hereinafter referred to as “this code.”
2. Sections 102 thru 114 in Chapter One are hereby deleted in their entirety as these
sections shall be as determined in accordance with applicable and corresponding
Chapter One sections of the adopted International Building Code, as amended.
3. SECTION 304 FLOOD HAZARD AREAS is deleted in its entirety and replaced
with the following:
SECTION 304 FLOOD HAZARD AREAS
304.1 Flood hazard areas. For buildings or structures regulated under the scope of this
code that are in whole or in part located in flood hazard areas, construction documents
shall be submitted as established in accordance with the Code of the City, Chapter 10,
entitled “FLOOD PREVENTION AND PROTECTION.”
304.2 GFCI protection. Electrical equipment installed below the design flood
elevation shall be supplied by branch circuits that have ground-fault circuit interrupter
protection for personnel.
4. Section 403.1 Maximum bather load is hereby amended to read as follows:
403.1 Maximum bather load. The maximum bather occupant load shall be per the
International Building Code, SECTION 1004 OCCUPANT LOAD, as adopted.
5. Section 410.1 Toilet Facilities is hereby amended to read as follows:
410.1 Toilet facilities. Class A, B and C pools shall be provided with toilet facilities
having the required number of plumbing fixtures in accordance with the International
Building Code or the International Plumbing Code, to the extent adopted by the
Colorado Plumbing Code.
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
____________________________________
Mayor
ATTEST:
_____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
____________________________________
Mayor
ATTEST:
_____________________________
City Clerk
- 1 -
ORDINANCE NO. 026, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE II, DIVISION 3 OF THE CODE OF THE
CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE 2006
INTERNATIONAL PROPERTY MAINTENANCE CODE AND ADOPTING THE 2021
INTERNATIONAL PROPERTY MAINTENANCE CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both to align the publication years of the codes and
because the 2021 publications contain improvements in construction code regulation; and
WHEREAS, the International Property Maintenance Code constitutes minimum
requirements and standards for premises, structures, equipment and facilities for light, ventilation,
space, heating, sanitation, protection from the elements, life safety, safety from fire and other
hazards, and for safe and sanitary maintenance of such structures; and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the 2021 International Property Maintenance
Code be adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
- 2 -
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 20, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2006 International Property
Maintenance Code (“IPMC”) and hereby adopts the 2021 IPMC as amended by this Ordinance.
Section 3. That Section 5-46 of the Code of the City of Fort Collins is hereby amended to
read as follows:
Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-16-202
and Article II, Section 7 of the Charter, the City Council has adopted the 2021 International
Property Maintenance Code, published by the International Code Council, as amended by
the City, which shall have the same force and effect as if set forth in full herein. The subject
matter of the codes adopted herein includes minimum requirements and standards for
premises, structures, equipment and facilities for light, ventilation, space, heating,
sanitation, protection from the elements, life safety, safety from fire and other hazards, and
for safe and sanitary maintenance; the responsibility of owners, operators and occupants;
the occupancy of existing structures and premises, and for administration, enforcement and
penalties. As provided in the 2021 International Property Maintenance Code, Appendices
are not adopted except as expressly set forth in Section 5-47.
Section 4. That Section 5-47 of the Code of the City of Fort Collins is hereby repealed
and re-enacted to read as follows:
Sec. 5-47. – Amendments and deletions to the 2021 International Property
Maintenance Code.
The 2021 International Property Maintenance Code adopted in Section 5-46 is hereby
amended to read as follows:
1. Section 101.1 Title is hereby amended to read as follows:
- 3 -
101.1 Title. These regulations shall be known as the International Property
Maintenance Code of the City of Fort Collins, hereinafter referred to as “this code.”
2. Section 101.2 Scope is hereby amended to read as follows:
101.2 Scope. Except as otherwise specified, the provisions of this code shall apply to
all existing residential and nonresidential structures and all existing premises and
constitute minimum requirements and standards for premises, structures, equipment
and facilities for light, ventilation, space, heating, sanitation, protection from the
elements, a reasonable level of safety from fire and other hazards, and for a reasonable
level of sanitary maintenance; the responsibility of owners, an owner’s authorized
agent, operators and occupants; the occupancy of existing structures and premises, and
for administration, enforcement and penalties.
3. Section 102.2 Maintenance is hereby amended to read as follows:
102.2 Maintenance. Equipment, systems, devices and safeguards required by this code
or a previous regulation or code under which the structure or premises was constructed,
altered or repaired shall be maintained in good working condition. An owner, owner’s
authorized agent, operator or occupant shall not cause any service, facility, equipment
or utility that is required under this section to be removed from, shut off from or
discontinued for any occupied dwelling, except for such temporary interruption as
necessary while repairs or alterations are in progress. The requirements of this code are
not intended to provide the basis for removal or abrogation of fire protection and safety
systems and devices in existing structures. Except as otherwise specified herein, the
owner or the owner’s authorized agent shall be responsible for the maintenance of
buildings, structures and premises.
4. Section 102.3 Application of other codes is hereby amended to read as follows:
102.3 Application of other codes. Repairs, additions or alterations to a structure, or
changes of occupancy, shall be done in accordance with the procedures and provisions
of the International Building Code, International Existing Building Code, International
Energy Conservation Code, International Fire Code, International Fuel Gas Code,
International Mechanical Code, International Residential Code, the International
Plumbing Code to the extent adopted by the Colorado Plumbing Code, NFPA 70 and
all other applicable City codes. Nothing in this code shall be construed to cancel,
modify or set aside any provision of the City’s Land Use Code.
5. SECTION 103 CODE COMPLIANCE AGENCY is hereby deleted in its entirety,
and replaced with the following:
SECTION 103
CODE ADMINISTRATION
- 4 -
103.1 Entity charged with code administration shall be as determined in accordance
with Section 103 of the adopted International Building Code, entitled “CODE
ADMINISTRATION.”
6. SECTION 104 FEES is hereby deleted in its entirety, and replaced with the following:
SECTION 104 FEES
104.1 Fees. All items relating to fees shall be as specified in Section 109 of the
adopted International Building Code, entitled “FEES.”
7. Section 105.1 General is hereby deleted in its entirety and replaced with the following:
105.1 General. The Community Development and Neighborhood Services
Department (CDNS) is charged with the administration and enforcement of this
code. The code official, appointed by the City Manager, is charged with the direct
overall administration and enforcement of this code and, in the performance of said
duties, may delegate the necessary authority to the appropriate technical,
administrative, and compliance staff under the supervision the code official.
8. Section 105.2 Inspections is hereby amended to read as follows:
105.2 Inspections. The code official shall make all of the required inspections, or shall
accept reports of inspection by approved agencies or individuals. Reports of such
inspections shall be in writing and be certified by a responsible officer of such approved
agency or by the responsible individual. The code official is authorized to engage such
expert opinion as deemed necessary to report on unusual technical issues that arise,
subject to the approval of the appointing authority. Whenever necessary to make an
inspection to enforce any of the provisions of this code, or whenever the code official
has probable cause to believe that there exists in any building or upon any premises any
condition or violation which makes such building or premises unsafe, dangerous, unfit
for occupancy, or unlawful, the code official may enter such building or premises at all
reasonable times to inspect it or to perform any duty imposed upon the code official by
this code. If such building or premises is occupied, the code official shall present proper
credentials and request entry. If such building or premises is unoccupied, the code
official shall first make a reasonable effort to locate the owner or other persons having
charge or control of the building or premises and request entry. If such entry is refused,
or, if after reasonable efforts to contact the owner or occupant, the owner or occupant
cannot be found or fails to respond or consent to the request, the code official may seek
an inspection warrant from the Municipal Judge to secure entry for inspection or
abatement.
9. Section 105.3 Right of entry is hereby deleted in its entirety and replaced with the
following:
105.3 Right of entry. When the code official has obtained a warrant or other remedy
provided by law to secure entry, no owner or occupant or any other persons having
- 5 -
charge, care or control of any building or premises shall fail or neglect, after proper
request is made as herein provided, to promptly permit entry therein by the code official
for the purpose of inspection, examination or abatement pursuant to this code. Any
such failure to permit entry upon request pursuant to a valid inspection warrant shall
be a misdemeanor punishable by the provisions set forth in City Code §1-15.
10. SECTIONS 107 MEANS OF APPEAL and SECTION 108 BOARD OF
APPEALS, are hereby deleted in their entirety and replaced with the following:
SECTION 107 MEANS OF APPEAL
107.1 Means of Appeal. Appeals of decisions, determinations and interpretations of
this code shall be made pursuant to the applicable provisions of Section 113 of the
adopted International Building Code, entitled “MEANS OF APPEALS.”
11. Section 109.3 Prosecution of violation is hereby amended to read as follows:
109.3 Prosecution of violation. Any person failing to comply with a notice of
violation or order served in accordance with Section 111.4 commits a civil infraction
and is subject to the provisions contained in § 1-15(f) of the City Code. Each day that
a violation continues shall be deemed a separate offense. If the notice of violation is
not complied with, the code official shall institute the appropriate proceeding at law or
in equity to restrain, correct or abate such violation, or to require the removal or
termination of the unlawful occupancy of the structure in violation of the provisions of
this code or of the order or direction made pursuant thereto. Any action taken by the
authority having jurisdiction on such premises shall be charged against the real estate
upon which the structure is located and shall be a lien upon such real estate.
12. Section 109.4 Violation penalties is hereby amended to read as follows:
109.4 Violation penalties. Any person who violates a provision of this code, or fails
to comply therewith, or with any of the requirements thereof, commits a civil infraction
and is subject to §1-15 of the City Code. Each day that a violation continues after due
notice has been served shall be deemed a separate offense.
13. Section 111.4.1 Form is hereby amended to read as follows:
111.4.1 Form. Such notice shall be in accordance with all of the following:
1. General. The code official and any officer, as the term officer is defined in City
Code §19-63, are authorized to give written notice to any owner or occupant
whose building or property is in violation of the provisions of this code. Such
notice may be personally served upon such person or, if not personally served,
shall be deposited in the United States mail, addressed to the owner of record
at the address on the assessment roll of the Larimer County Assessor or at such
other, more recent address as may be available to the City.
- 6 -
2. Notice. The notice shall include a description of the real estate sufficient for
identification, include a statement of the violation or violations and why the
notice is being issued, and state that if the violation is not corrected on or before
the date and time stipulated in the notice, a citation may issue and the correction
or demolition may be done by the City and any costs of abatement, repair or
demolition, including the cost of inspection, the cost of any grading or sloping
necessary to protect the public safety, and other incidental costs in connection
therewith, and an amount not to exceed one hundred percent of the costs for
carrying charges and costs of administration, will be charged against the
property, in addition to any other penalty and costs or orders that may be
imposed. The notice shall also state that if the owner desires a hearing before
the Building Review Commission to contest the declaration and order of
vacation, condemnation, repair, removal or demolition, such owner shall
request a hearing, in writing, to the code official within ten days of mailing of
the notice. The notice shall further state that failure to timely file a request for
such hearing shall be a waiver of the right to contest the declaration, assessment
or order at any later date.
3. Abatement. If the building or property has not been brought into compliance
with this code within the time period set forth in the notice and, if the owner
has not requested a hearing before the Building Review Commission to contest
said declaration or any other code official's orders as provided in Subparagraph
#1 above, the demolition or abatement may be performed by City personnel or
by private contractors, as the code official shall determine. In the event of such
demolition and abatement by the city, the cost, including inspection, demolition
and any other incidental costs in connection therewith, and an amount not to
exceed one hundred percent of the costs for carrying charges and
administration, shall be assessed against the building or property.
4. Assessment. Any cost assessment shall be a lien in the several amounts assessed
against each property until paid and shall have priority over all other liens,
except general taxes and prior special assessment liens. If any such assessment
is not paid within thirty days after it has been certified by the code official and
billed by the City to the owner by deposit in the United States mail addressed
to the owner of record at the address as shown on the tax rolls or such other,
more recent address as may be available to the City, and any agents,
representatives or occupants as may be known, the Financial Officer, or their
designee is hereby authorized to certify to the County Treasurer the list of
delinquent assessments, giving the name of the owner as it appears of record,
the number of the lot and block and the amount of the assessment plus a ten-
percent penalty. The certification is to be the same in substance and in form as
required for the certification of other taxes. The County Treasurer, upon receipt
of such certified list, is hereby authorized to place it upon the tax list for the
current year and to collect the assessment in the same manner as general
property taxes are collected, together with any charges as may by law be made
by the county treasurer and all laws of the state for the assessment and collection
of general taxes, including the laws for the sale of property for taxes, and the
- 7 -
redemption thereof shall apply to and have full force and effect for the
collection of all such assessments. Notwithstanding the foregoing, if the
offending building or property is not subject to taxation, the City may elect
alternative means to collect the amounts due pursuant to this code, including
the commencement of an action at law or in equity and, after judgment, pursue
such remedies as are provided by law.
14. A new Section 111.10 Responsibilities and obligations is hereby added to read as
follows:
111.10 Responsibilities and obligations. Every owner and occupant shall be subject
to the responsibilities and obligations set forth in this code as follows:
1. Every owner remains liable for violations of duties imposed by this code even
though an obligation is imposed on the occupants of the building and even
though the owner has by agreement imposed on the occupant or property
manager the duty of furnishing required equipment or of complying with this
code. Nothing herein shall be construed as limiting or interfering with in any
way the right of any persons to establish by written contract specific
responsibilities of owners, property managers and occupants for the purpose of
leasing or renting a building or premises. Every owner or agent, in addition to
being responsible for maintaining the building in a sound structural condition,
shall be responsible for keeping that part of the building or premises which the
owner occupies or controls in a safe condition, including the shared or public
areas in a building containing two or more dwelling units.
2. An owner shall not permit another person to occupy premises which are not in
a sanitary and safe condition, and which do not comply with the requirements
of this code.
3. Occupants of a dwelling unit, rooming unit or housekeeping unit are
responsible for keeping in a clean, sanitary and safe condition that part of the
dwelling unit, rooming unit, housekeeping unit or premises which they occupy
and control.
4. Every occupant shall, when required by this code, the City Code or the Health
Officer, furnish and maintain approved devices, equipment or facilities
necessary to keep the premises safe and sanitary.
15. Section 112.5 Cost of emergency repairs is hereby amended to read as follows:
112.5 Costs of emergency repairs. For the purposes of this section, the code official
shall employ, or cause to be employed, the necessary labor and procure materials to
perform the work required as expeditiously as possible. Costs incurred in the
performance of emergency work shall be paid by the jurisdiction. The legal counsel of
the jurisdiction shall institute appropriate action, including a lien upon the property
pursuant to section 111.4.1, against the owner of the premises or owner’s authorized
agent where the unsafe structure is or was located for the recovery of such costs.
16. A new Section 113.5 Historical is added to read as follows:
- 8 -
113.5 Historical. For any site, structure, or object 50 years of age or older and subject
to any of the processes contained in Chapter 14 of the City Code that in the code
official's judgment is so old, dilapidated or has become so out of repair as to be
dangerous, unsanitary or otherwise unfit for human habitation or occupancy, the code
official shall order the owner to repair the site, structure, or object to make it safe and
sanitary unless the owner has complied with all applicable requirements of Chapter 14
or the building official has determined that such site, structure, or object is an imminent
danger.
17. Section 201.3 Terms defined in other codes is hereby amended to read as follows:
201.3 Terms defined in other codes. Where terms are not defined in this code and are defined
in the City Code, the Land Use Code and any other code adopted by reference in the
City Code, including the International Building Code, International Existing Building
Code, International Fire Code, International Fuel Gas Code, International Mechanical
Code, the International Plumbing Code to the extent adopted by the Colorado
Plumbing Code, International Residential Code, or NFPA 70, such terms shall have
the meanings ascribed to them as stated in those codes.
Exception: When used within this code, the terms unsafe and dangerous shall have
only the meanings ascribed to them in this code and shall not have the meanings
ascribed to them by the International Existing Building Code.
18. SECTION 202 GENERAL DEFINITIONS is hereby amended to modify, or add, in
alphabetical order, the following definitions:
ABANDONED. Any building or premises covered under this code that is unoccupied
or vacant and in such a state of disrepair, lack of maintenance, or neglect as to pose a
public nuisance.
ADDITION. An extension or increase in floor area, number of stories, or height of a
building or structure.
ALTERATION. Any construction or renovation to an existing structure other than
repair or addition.
CODE OFFICIAL. The official who is charged with the administration and
enforcement of this code and any duly authorized representatives. The term code
official is interchangeable with the term building official.
EXCAVATION or FOUNDATION, ABANDONED or EXPOSED. Any outdoor
open hole, pit, foundation or other excavation, or depression, deeper than twenty-four
inches below the surrounding ground elevation other than a well, whether excavated
by human activity or created by natural forces, including any excavation or foundation
intended for a building, pool, pond or other decorative or recreational feature and not
backfilled within one hundred eighty days of such excavation or foundation work, or
- 9 -
when there is no valid active building permit for such work, as well and any other type
of excavation that poses a health or safety hazard or otherwise poses a public nuisance,
except approved temporary retention ponds and detention ponds and other water
features such as pools, ponds, and similar approved excavations designed for
recreational or aesthetic purposes that are maintained in a condition that does not pose
a health or safety hazard and is not a public nuisance.
FLOOD HAZARD AREA. All references to “flood hazard” and “areas prone to
flooding” in this code and appendices adopted therewith shall be as specified in the
Code of the City, “Chapter 10, Flood Prevention and Protection.
GRADE PLANE. A reference plane representing the average of the finished ground
level adjoining the building at all exterior walls. Where the finished ground level slopes
away from the exterior walls, the reference plane shall be established by the lowest
points within the area between the building and the lot line or, where the lot line is more
than 6 feet (1829 mm) from the building between the structure and a point 6 feet (1829
mm) from the building.
GOOD CONDITION. A condition that is fully functional, operational and
substantially free from decay, deterioration, damage or other defects and capable of
performing the tasks for which designed and in the manner intended without risk of
injury or damage to persons or adjoining property resulting from detachment or failure
of such elements or components thereof.
HAZARDOUS. Whatever is dangerous to human life or is detrimental to the public
health as determined by the Health Officer, the Poudre Fire Authority Fire Chief, or the
code official.
HEALTH OFFICER. The legally designated head of the Larimer County Department
of Health and Environment or such person’s authorized agent.
HISTORIC BUILDING is a building or structure that has been designated by official
action of the legally constituted authority of the City Council as having special
historical, architectural or geographical significance. For purposes of this code, this
term also shall include buildings or structures listed in the State Register of Historic
Properties as published by the History Colorado or the National Register of Historic
Places as published by the United States Department of the Interior.
IMMINENT DANGER. An existing condition that is reasonably likely to cause
immediate serious or life-threatening injury or death.
LIMIT STATE. A condition beyond which a structure or member becomes unfit for
service and is judged to be no longer useful for its intended function (serviceability
limit state) or to be unsafe (strength limit state).
OWNER. Any person whose name appears on the tax bill for the property or who,
alone or jointly or severally with others, has legal title to any dwelling or dwelling unit,
- 10 -
with or without actual possession thereof, or has charge, care or control of any dwelling
or dwelling unit as owner, executor, executrix, administrator, trustee, guardian of the
estate of the owner, mortgagee or assignee of rents. Owner shall not include, except for
vacant structures or premises as provided for in state law, any person, group of persons,
company, association or corporation who holds only a security interest or easement on
the real property upon which the dwelling or dwelling unit is situated.
PRIMARY FUNCTIONS. A major activity for which the facility is intended. Areas
that contain a primary function include, but are not limited to, the customer service
lobby of a bank, the dining area of a cafeteria, the meeting rooms in a conference center,
as well as offices and other work areas in which the activities of the public
accommodation or other private entity using the facility are carried out. Mechanical
rooms, boiler rooms, supply storage rooms, employee lounges or locker rooms, and
janitorial closets are not areas containing a primary function. Entrances, corridors and
restrooms are considered areas containing a primary function.
PROPERTY MANAGER. Any person, group of persons, company, firm or
corporation charged with the care and control of a building, structure or premises who
performs services with respect to such building, structure or premises under a contract
with the owner thereof or who otherwise acts as representative of an owner with respect
to such building, structure or premises.
RENTAL DWELLING UNIT. One or more rooms occupied or intended to be
occupied as a unit exclusively for residential purposes that is leased, rented or sublet
for compensation (including money or services or the sharing of expenses) and that is
located in a boarding house or a single-family, two-family or multi-family dwelling.
RENTAL HOUSING. Any building or mobile home or portion thereof, including the
lot, tract or parcel of land on which the same is located, containing any dwelling unit,
or guest room which is leased, rented or sublet to a family or person(s) for
compensation.
REPAIR. The restoration to good condition of any part of an existing building for the
purpose of its maintenance.
SUBSTANDARD. Condition(s) that through neglect, deterioration, or damage no
longer meet the minimum requirements of the currently adopted code as it relates to
the specific condition(s) identified. Even though such condition(s) may not be found
dangerous at the time of their discovery, such condition(s), if not corrected, may pose
a risk to the health and safety of the public, the occupants or property thereof pursuant
to Section 111.1.5.
SUBSTANTIAL DAMAGE. For the purpose of determining compliance with the
flood provisions of this code, damage of any origin sustained by a structure whereby
the cost of restoring the structure to its before-damaged condition would equal or
exceed fifty percent of the market value of the structure before the damage occurred.
- 11 -
SUBSTANTIAL IMPROVEMENT. For the purpose of determining compliance
with the flood provisions of this code or the City Code, any repair, alteration, addition,
or improvement of a building or structure, the cost of which equals or exceeds fifty
(50) percent of the market value of the structure before the improvement or repair is
started. If the structure has sustained substantial damage, any repairs are considered
substantial improvement regardless of the actual repair work performed. The term does
not, however, include either: (1) any project for improvement of a building required to
correct existing health, sanitary, or safety code violations identified by the code official
and that is the minimum necessary to assure safe living conditions; or (2) any alteration
of a historic structure, provided that the alteration will not preclude the structure’s
continued designation as a historic structure.
SUBSTANTIAL STRUCTURAL DAMAGE. A condition where: (1) in any story,
the vertical elements of the lateral-force resisting system, in any direction and taken as
a whole, have suffered damage such that the lateral load-carrying capacity has been
reduced by more than twenty percent from its pre-damaged condition; or (2) the vertical
load-carrying components supporting more than thirty percent of the structure’s floor
or roof area have suffered a reduction in vertical load-carrying capacity to below
seventy-five percent of the Building Code’s required strength levels calculated by either
the strength or allowable stress method.
SUBSTANTIALLY PLUMB. A wall or other vertical member shall be considered
substantially plumb when a plumb line passing through the center of gravity does not
fall outside the middle one-third (1/3) of the base.
TECHNICALLY INFEASIBLE. An alteration of a building or a facility that has little
likelihood of being accomplished because the existing structural conditions require the
removal or alteration of a load-bearing member that is an essential part of the structural
frame, or because other existing physical or site constraints prohibit modification or
addition of elements, spaces or features which are in full and strict compliance with the
minimum requirements for new construction and which are necessary to provide
accessibility.
VACANT. The state of premises or a structure thereon being indefinitely uninhabited
or unoccupied by lawfully authorized tenants, owners, and other persons.
19. Section 302.2 Grading and drainage is hereby amended to read as follows:
302.2 Grading and drainage. Premises shall be graded and maintained to prevent the
erosion of soil and to prevent the accumulation of stagnant water thereon, or within any
structure located thereon. Drainage of paved areas, yards and courts, and other open
areas on the premises shall not be discharged in a manner that creates a public nuisance.
Abandoned or unprotected excavations shall be considered a nuisance and shall be
filled to the original or adjoining site elevation.
Exception: Approved retention areas and reservoirs and temporary retention ponds,
detention ponds, channels and other water features such as pools, ponds, and similar
- 12 -
approved excavations designed for recreational or aesthetic purposes that are
maintained in a condition that does not pose a health or safety hazard, or a public
nuisance.
20. A new Section 302.3.1 Walkway surfaces is hereby added to read as follows:
302.3.1 Walkway surfaces. Walkways shall be stable, slip resistant, flush, and even to
the extent possible. Where walkways cannot be made flush and even, they shall
conform to the following requirements:
1. Adjoining walkway surfaces shall be made flush and level, to the extent
practicable.
2. Changes in levels up to ½” (6mm) may be vertical and without edge treatment.
3. Changes in levels greater than ½” and less than 4” shall be considered a trip
hazard and shall be transitioned by means of a ramp that complies with the
International Building Code or the International Residential code, whichever
applies.
21. Section 302.5 Rodent harborage is hereby amended to read as follows:
302.5 Rodent harborage. Structures and exterior property shall be kept free from
rodent harborage and infestation. Where rodents are found, they shall be promptly
eliminated by approved means or processes that will not be injurious to human health.
After pest elimination, proper precautions shall be taken to eliminate rodent harborage
and prevent reinfestation. The owner of any building or structure shall be responsible
for pest elimination within the structure prior to renting or leasing such. The owner(s)
of any building or structure shall be responsible for pest elimination in the public or
shared areas of the structure and exterior premises.
22. Section 304.14 Insect screens is hereby amended to read as follows:
304.14 Insect screens. During the period from April 1 to November 1, every door,
window and other outside opening required for ventilation of habitable rooms, food
preparation areas, food service areas or any areas where products to be included or
utilized in food for human consumption are processed, manufactured, packaged or
stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per
inch (16 mesh per 25 mm), and every screen door used for insect control shall have a
self-closing device in sound working condition.
Exception: Screens shall not be required for owner-occupied dwelling units where
no rooms are leased or rented.
23. A new Section 304.20 Area wells is hereby added to read as follows:
304.20 Area wells. All area wells, stair wells, light wells and any other bulkhead
enclosures attached to any building shall be protected with guards conforming to this
section around the entire opening, or be provided with an equivalent barrier, when such
- 13 -
wells are located less than thirty-six (36) inches (194 mm) from the nearest intended
walking surface and are deeper than thirty-six inches below the surrounding ground
level, with the side walls of such well having a slope steeper than two horizontal to one
vertical.
Exceptions:
1. The access side of stairways need not be barricaded.
2. Area wells provided for emergency escape and rescue windows may be
protected with approved grates or covers that are releasable or removable
from the inside without the use of a key, tool or force greater than that which
is required for normal operation of the escape and rescue opening.
3. Covers and grates may be used over stairways and other openings used
exclusively for services access or for admitting light or ventilation.
24. A new Section 305.4.1 Public stairways is hereby added to read as follows:
305.4.1 Public stairways. Public stairways used for egress routes in areas serving
more than one rental dwelling unit or guestroom shall be maintained in good condition.
25. Section 309.2 Owner is hereby amended to read as follows:
309.2 Owner. The owner of any structure shall be responsible for pest elimination
within the structure prior to renting or leasing the structure. The owner(s) shall be
responsible for pest elimination in the public or shared areas of the structure and
exterior premises.
26. Section 309.3 Single Occupant is hereby deleted in its entirety.
27. Section 404.2 Minimum room widths, is hereby deleted in its entirety.
28. Section 404.3 Minimum ceiling heights is hereby deleted in its entirety.
29. Section 404.4 Bedroom and living room requirements is hereby deleted in its
entirety.
30. Section 404.4.1 Room area is hereby deleted in its entirety.
31. Section 404.5 Overcrowding is hereby deleted in its entirety.
32. Section 404.5.1 Sleeping area is hereby deleted in its entirety.
33. Section 404.5.2 Combined spaces is hereby deleted in its entirety.
34. Section 404.6 Efficiency unit is hereby deleted in its entirety.
35. Section 602.2 Residential occupancies is hereby amended to read as follows:
- 14 -
602.2 Residential occupancies. Dwellings shall be provided with heating facilities
capable of maintaining a room temperature of 68°F (20°C) in all habitable rooms,
bathrooms and toilet rooms based on the winter outdoor design temperature indicated
in Table R301.2 in the International Residential Code. Cooking appliances shall not
be used, nor shall portable unvented fuel-burning space heaters be used, as a means to
provide required heating. The installation of one or more portable space heaters shall
not be used to achieve compliance with this section.
Exception: In areas where the average monthly temperature is above 30°F (-1°C),
a minimum temperature of 65°F (18°C) shall be maintained.
36. Section 602.3 Heat supply is hereby amended to read as follows:
602.3 Heat supply. Every owner and operator of any building who rents, leases or lets
one or more dwelling units or sleeping units on terms, either expressed or implied, to
furnish heat to the occupants thereof shall supply heat during the period from
September 15 to May 15 to maintain a minimum temperature of 68°F (20°C) in all
habitable rooms, bathrooms and toilet rooms.
Exceptions:
1. When the outdoor temperature is below the winter outdoor design
temperature for the locality, maintenance of the minimum room temperature
shall not be required provided that the heating system is operating at its full
design capacity. The winter outdoor design temperature indicated in Table
R301.2 in the International Residential Code.
2. In areas where the average monthly temperature is above 30°F (-1°C), a
minimum temperature of 65°F (18°C) shall be maintained.
37. Section 602.4 Occupiable work spaces is hereby amended to read as follows:
602.4 Occupiable work spaces. Indoor occupiable work spaces shall be supplied with
heat during the period from September 15 to May 15 to maintain a minimum
temperature of 65°F (18°C) during the period the spaces are occupied.
Exceptions:
1. Processing, storage and operation areas that require cooling or special
temperature conditions.
2. Areas in which persons are primarily engaged in vigorous physical activities.
38. Section 605.2 Receptacles is hereby amended to read as follows:
605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two
separate and remote receptacle outlets. Every laundry area shall contain not less than
one grounding-type receptacle or a receptacle with a ground fault circuit interrupter.
Every bathroom shall contain not less than one receptacle. Any new bathroom
receptacle outlet shall have ground fault circuit interrupter protection. All receptacle
- 15 -
outlets shall have the appropriate faceplate cover for the location. Receptacle outlets
installed in kitchens, bathrooms, garages, unfinished basements, exterior locations
and/or any receptacles that are installed within 6 ft from the top inside edge of the bowl
of a sink or outside edge of a bathtub or shower shall have ground fault circuit
interrupter protection.
39. Section 606.1 General is hereby amended to read as follows:
606.1 General. Elevators, dumbwaiters and escalators shall be maintained in
compliance with ASME A17.1. The most current certification of inspection shall be on
display at all times within the elevator or attached to the escalator or dumbwaiter, be
available for public inspection in the office of the building operator or be posted in a
publicly conspicuous location approved by the code official. The inspection and tests
shall be performed at not less than the periodic intervals listed in ASME A17.1, as
specified by the State of Colorado’s Conveyance Regulations at 7 CCR 1101-8.
40. Section 702.4, Emergency escape and rescue openings, is hereby amended to read
as follows:
702.4 Emergency escape and rescue openings. Required emergency escape and
rescue openings shall be maintained in accordance with the code in effect at the time
of construction, and the following:
1. Required emergency escape and rescue openings shall be operational from the
inside of the room without the use of keys or tools.
2. Bars, grilles, grates or similar devices are permitted to be placed over
emergency escape and rescue openings provided the minimum net clear
opening size complies with the code that was in effect at the time of
construction and the unit is equipped with smoke alarms installed in accordance
with Chapter 9 of the International Fire Code, as adopted. Such devices shall
be releasable or removable from the inside without the use of a key, tool or
force greater than that which is required for normal operation of the escape and
rescue opening.
3. The minimum net clear opening size shall comply with the Building Code that
was in effect at the time of construction or shall provide a minimum net clear
opening of no less than 720 square inches, whichever is greater, and shall not
have a sill height greater than forty-eight inches as measured above the interior
floor level of the room in which such opening is located.
41. APPENDIX A BOARDING STANDARD is hereby adopted in its entirety.
Section 4. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
- 16 -
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
____________________________________
Mayor
ATTEST:
_____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_______________________________
City Clerk
ORDINANCE NO. 027, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE IV OF THE CODE OF THE
CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE
2018 INTERNATIONAL MECHANICAL CODE AND ADOPTING THE
2021 INTERNATIONAL MECHANICAL CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both in order to align the publication years of the
codes and because the 2021 publications contain improvements in construction code regulation;
and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received from the Water Commission,
Energy Board, Commission on Disability, Natural Resource Advisory Board, Poudre Fire
Authority Board, Building Review Commission, Affordable Housing Board, and Air Quality
Advisory Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the 2021 International Mechanical Code be
adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
- 2 -
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Mechanical Code
(“IMC”) and hereby adopts 2021 IMC as amended by this Ordinance.
Section 3. That Section 5-106 of the Code of the City of Fort Collins is hereby
amended to read as follows:
Sec. 5-106. – Adoption of standards.
Pursuant to the power and authority conferred on the City Council by C.R.S. § 31-16-202
and Article II, Section 7 of the Charter, the City Council has adopted the 2021
International Mechanical Code, published by the International Code Council, as amended
by the City, which shall have the same force and effect as though set forth in full herein.
The subject matter of the 2021 International Mechanical Code adopted herein includes
comprehensive provisions and standards regulating and controlling the design,
construction, installation, quality of materials, location, operation and maintenance of
heating, ventilating, cooling and refrigeration systems, incinerators, miscellaneous heat-
producing appliances for the purposes of protecting public health, safety and general
welfare. None of the 2021 International Mechanical Code Appendices are adopted.
Section 4. That Section 5-107 of the Code of the City of Fort Collins is hereby repealed
and re-enacted to read as follows:
Sec. 5-107. - Amendments and deletions to the 2021 International Mechanical Code.
The 2021 International Mechanical Code adopted in § 5-106 is hereby amended to
read as follows:
1. Section 101.1 Title is hereby amended to read as follows:
101.1 Title. These regulations shall be known as the Mechanical Code of the City of
Fort Collins, hereinafter referred to as “this code.”
2. Section 102.8 Referenced codes and standards is amended to read as follows:
- 3 -
Section 102.8 reference codes and standards. The codes and standards referenced
herein shall be those that are listed in Section 101.4 of the adopted International
Building Code, entitled “Referenced Codes,” and shall be considered as part of the
requirements of this code to the prescribed extent of each such reference and as further
regulated in Sections 102.8.1 and 102.8.2.
Exception: Where enforcement of a code provision would violate the conditions
of the listing of the equipment or appliance, the conditions of the listing and the
manufacturer’s installation instructions shall apply.
3. Section 103 Code Compliance Agency is hereby deleted in its entirety and replaced
with the following:
SECTION 103 – CODE ADMINISTRATION
103.1 Entity charged with code administration shall be as determined in accordance
with Section 103 of the adopted International Building Code, entitled “CODE
ADMINISTRATION.”
4. Section 106.1.1 Annual permit and Section 106.1.2 Annual permit records are
deleted in their entirety.
5. Section 108.3 Testing is hereby deleted in its entirety and replaced with the following:
108.3 Testing. Installed heating, cooling and ventilation systems shall be performance-
tested by an approved agency and adjusted to operate within design specifications, in
accordance with ANSI/ACCA QI 5-2010 HVAC Quality Installation Specification.
Documentation of results shall be submitted to the building official prior to approval.
Exception: Buildings subject to commissioning requirements in SECTION C408 of
the 2021 International Energy Conservation Code, as amended.
6. Section 109 Fees is hereby deleted in its entirety and replaced with the following:
SECTION 109 FEES
109.1 Fees. All items relating to fees shall be as specified in Section 109 of the adopted
International Building Code, entitled “FEES.”
7. SECTION 114 MEANS OF APPEAL is hereby deleted in its entirety and replaced
with the following:
SECTION 114
MEANS OF APPEALS
114.1 General. Appeals of decisions, determinations and interpretations of this code
shall be made pursuant to the applicable provisions of Section 113 of the adopted
International Building Code, entitled “MEANS OF APPEALS.”
- 4 -
8. Section 115.4 Violation Penalties is hereby deleted in its entirety and replaced with
the following:
115.4 Violation penalties. All items related to violation penalties shall be made
pursuant to the applicable provisions of Section 114.4 of the adopted International
Building Code.
9. A new Section 115.4.1 Work Commencing before permit issuance is hereby added
to read as follows:
115.4.1 Work commencing before permit issuance. All items related to work
commencing before permit issuance shall be made pursuant to the applicable provisions
of Section 109.2 of the adopted International Building Code.
10. SECTION 202 GENERAL DEFINITIONS is hereby amended to add the following
definitions in alphabetical sequence as follows:
MULTIFAMILY. Any building housing group R-1, R-2 or R-4 occupancies.
WHOLE-DWELLING UNIT MECHANICAL VENTILATION SYSTEM. An
exhaust system, supply system, or combination thereof that is designed to mechanically
exchange indoor air for outdoor air when operating continuously or through a
programmed intermittent schedule to satisfy the whole-dwelling ventilation rate.
11. Section 403.3.2 Group R-2, R-3 and R-4 occupancies, three stories and less is
hereby amended to read as follows:
403.3.2 Group R-2, R-3 and R-4 occupancies, three stories and less. The design of
local exhaust systems for outdoor air in Group R-2, R-3 and R-4 occupancies shall
comply with Sections 403.3.2.1 through 403.3.2.7.
12. Section 403.3.2.1 Outdoor air for dwelling units is amended to read as follows:
403.3.2.1 Outdoor air for dwelling units. An outdoor air ventilation system consisting
of a mechanical exhaust system, supply system or combination thereof shall be installed
for each dwelling unit. Local exhaust or supply systems, including outdoor air ducts
connected to the return side of an air handler, are permitted to serve as such system.
The outdoor air ventilation system shall be designed to provide the required rate of
outdoor air continuously during the period the building is occupied, and the system
design documents shall be submitted, as required by the building official, at the time of
application for a building permit. The minimum continuous outdoor airflow rate shall
be determined in accordance with Equation 4-9.
QOA= 0.01Afloor + 7.5(Nbr + 1) (Equation 4-9)
where:
QOA = outdoor airflow rate, cfm
Afloor = floor area, ft2
- 5 -
Nbr = number of bedrooms; not to be less than one
Exceptions:
1. The outdoor air ventilation system is not required to operate continuously
where the system has controls that enable operation for not less than 1
hour of each 4-hour period. The average outdoor airflow rate over the
4-hour period shall be not less than that prescribed by Equation 4-9.
2. The minimum mechanical ventilation rate determined in accordance with
Equation 4-9 shall be reduced by 30 percent provided that both of the
following conditions apply:
2.1. A ducted system supplies ventilation air directly to each bedroom and
to one or more of the following rooms:
2.1.1. Living room.
2.1.2. Dining room.
2.1.3. Kitchen.
2.2. The whole-house ventilation system is a balanced ventilation system.
13. A new Section 403.3.2.6 Sound ratings for fans i s added to read as follows:
403.3.2.6 Sound ratings for fans. Whole-dwelling unit ventilation fans shall be rated
for sound at maximum of 1.5 sones, in accordance with the procedures of the Home
Ventilating. Institute (HVI 915, Procedure for Loudness Rating of Residential Fan
Products). Heating, ventilating and air conditioning air handlers and remote-mounted
fans need not meet sound requirements.
14. A new Section 403.3.2.7 Performance verification is hereby added to read as follows:
403.3.2.7 Performance verification. Performance of installed mechanical ventilation
systems shall be verified in accordance with The City of Fort Collins Residential New
Construction Mechanical Systems Testing Guide as part of the Multifamily Residential
Mechanical Systems Performance Report provided to the building official.
15. Section 504.1 Installation is hereby amended to read as follows:
504.1 Installation. Clothes dryers shall be exhausted in accordance with the
manufacturer's instructions. Dryer exhaust systems shall be independent of all other
systems and shall convey the moisture and any products of combustion to the outside
of the building. Dryer exhaust duct terminations shall not be located within 36 inches
(914 mm) of exterior openings into conditioned spaces, crawl spaces, and attic spaces.
16. Section 506.3.11 Grease duct enclosures is hereby amended to read as follows.
506.3.11 Grease duct enclosures. A commercial kitchen grease duct serving a Type I
hood that penetrates a ceiling, wall, floor or any concealed space shall be enclosed from
the point of penetration to the outlet terminal. In-line exhaust fans not located outdoors
shall be enclosed as required for grease ducts. A duct shall penetrate exterior walls only
at locations where unprotected openings are permitted by the International Building
Code. The duct enclosure shall serve a single grease duct and shall not contain other
- 6 -
ducts, piping or wiring systems. Duct enclosures shall be a shaft enclosure in
accordance with Section 506.3.11.1, a field-applied enclosure assembly in accordance
with Section 506.3.11.2 or a factory-built enclosure assembly in accordance with
Section 506.3.11.3. Duct enclosures shall have a fire-resistance rating of not less than
that of the assembly penetrated and not less than 1 hour. Fire dampers and smoke
dampers shall not be installed in grease ducts.
17. Section 512.1 General is hereby amended to read as follows:
512.1 General. Where a subslab soil exhaust system is provided, the duct for such
system shall conform to the requirements of the 2021 International Residential Code,
Appendix AF, entitled “Radon Control Methods,” as adopted.
18. Section 601.5 Return air openings is hereby amended to read as follows:
601.5 Return air openings. Return air openings for heating, ventilation and air-
conditioning systems shall comply with all of the following:
1. Openings shall not be located less than 10 feet (3048 mm) measured in any
direction from an open combustion chamber or draft hood of another appliance
located in the same room or space.
2. Return air shall not be taken from a hazardous or insanitary location or a
refrigeration room as defined in this code.
3. The amount of return air taken from any room or space shall be not greater than
the flow rate of supply air delivered to such room or space.
4. Return and transfer openings shall be sized in accordance with the appliance or
equipment manufacturer’s installation instructions, ACCA Manual D or the
design of the registered design professional.
5. Return air taken from one dwelling unit shall not be discharged into another
dwelling unit.
6. Taking return air from a crawl space shall not be accomplished through a direct
connection to the return side of a forced air furnace. Transfer openings in the
crawl space enclosure shall not be prohibited.
7. Return air shall not be taken from a closet, bathroom, toilet room, kitchen,
garage, boiler room, furnace room or unconditioned attic.
8. Return air shall not be taken from indoor swimming pool enclosures and
associated deck areas.
Exceptions:
1. Where the air from such spaces is dehumidified in accordance with
Section 403.2.1, Item 2.
2. Dedicated HVAC systems serving only such spaces.
9. Return air for a dwelling shall be taken from inside the dwelling. Dilution of
return air with outdoor air is permitted. A return air path shall be provided in
all habitable rooms by means of ducts or transfer grills.
Exceptions:
- 7 -
1. Taking return air from a kitchen is not prohibited where such return air
openings serve the kitchen and are located not less than 10 feet (3048 mm)
from the cooking appliances.
2. Taking return air from a kitchen is not prohibited in a dwelling unit where
the kitchen and living spaces are in a single room and the cooking appliance
is electric and located not less than 5 feet (1524 mm) in any direction from
the return air intake opening.
3. Dedicated forced air systems serving only the garage shall not be prohibited
from obtaining return air from the garage.
19. Section 602.3 Stud cavity and joist space plenums is hereby deleted in its entirety and
replaced with the following:
602.3 Stud cavity and joist space plenums. Building framing cavities shall not be
used as ducts or plenums.
20. A new Section 603.18.3 Construction debris and contamination is hereby added to
read as follows:
603.18.3 Construction debris and contamination. Mechanical air-handling systems
and their related ducts shall be protected from the entrance of dirt, debris, and dust
during the construction and installation process. Prior to passing final inspection or
issuance of a Certificate of Occupancy, such systems shall be substantially free of
construction-related contaminants.
21. Section 801.19 Multistory prohibited is hereby amended to read as follows:
801.19 Multistory prohibited. Common venting systems for appliances located on
more than one floor level shall be prohibited, except engineered systems where all of
the appliances served by the common vent are located in rooms or spaces that are
accessed only from the outdoors. The appliance enclosures shall not communicate with
the occupiable areas of the building.
22. A new Section 903.1.1 Solid fuel fireplaces and appliances is added to read as
follows:
903.1.1 Solid fuel fireplaces and appliances. Solid fuel fireplaces, fireplace stoves
and solid-fuel-type room heaters shall comply with Section 5-110 of the City Code.
23. Section 903.3 Unvented gas logs heaters is deleted in its entirety.
24. A new Section 918.1.2 Total Electric Heating is added to read as follows:
918.1.2 Total Electric Heating. Primary indoor central heating systems utilizing only
electric heat shall utilize a ground source heat pump system(s) or cold climate heat
pump system(s) specifically designed to heat in cold climates and at the Winter
Outdoor, Design Dry-Bulb temp defined in IECC Section C301.5. The heat pump
- 8 -
system shall not be gas or propane fuel fired. Electric resistance strip heat shall serve
only as emergency backup heat or supplemental heat at outdoor temperatures below
15oF as necessary.
Exceptions:
1. Where the heating load is less than or equal to 6.0 Btu/h/ft2 at design
temperature, electric resistance heating shall be permitted.
2. Where conduit w/ pull string sized to accommodate future heating electrical
requirements is installed.
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
____________________________
City Clerk
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
- 1 -
ORDINANCE NO. 028, 2022
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE IV OF THE CODE OF THE
CITY OF FORT COLLINS FOR THE PURPOSE OF REPEALING THE
2018 INTERNATIONAL FUEL GAS CODE AND ADOPTING THE
2021 INTERNATIONAL FUEL GAS CODE, WITH AMENDMENTS
WHEREAS, since 1924, the City has reviewed, amended and adopted the latest nationally
recognized building standards available for the times; and
WHEREAS, upon recommendation of City staff, the City Council has determined that it is
in the best interests of the City to align nine interconnected basic construction codes under one
publication year; and
WHEREAS, the nine interconnected basic construction codes are the International
Building Code, International Residential Code, International Mechanical Code, International
Fuel Gas Code, International Energy Conservation Code, International Property Maintenance
Code, International Swimming Pool and Spa Code, International Existing Building Code, and the
International Plumbing Code to the extent adopted by the Colorado Plumbing Code; and
WHEREAS, the City Council has determined that the 2021 publication year of the nine
interconnected basic construction codes should be adopted and that any counterpart International
codes previously adopted should be repealed, both in order to align the publication years of the
codes and because the 2021 publications contain improvements in construction code regulation;
and
WHEREAS, City staff has conducted a significant public outreach program, working with
the regulated construction industry and building professionals; and
WHEREAS, the adoption of the nine interconnected basic construction codes has been
presented to community groups and feedback has been received by the Water Commission, Energy
Board, Commission on Disability, Natural Resources Advisory Board, Poudre Fire Authority
Board, Building Review Commission, Affordable Housing Board, and Air Quality Advisory
Board; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the 2021 International Fuel Gas Code be
adopted, with local amendments as set forth in this Ordinance; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall be
published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
- 2 -
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the 2021
International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. The City Council hereby repeals the 2018 International Fuel Gas Code
(“IFGC”) and hereby adopts the 2021 International Fuel Gas Code as amended by this Ordinance.
Section 3. That Section 5-111 of the Code of the City of Fort Collins is hereby
amended as follows:
Sec. 5-111. - Adoption of standards for fuel gas piping, equipment and accessories.
Pursuant to the power and authority conferred on the City Council by C.R.S. §31-16-202
and Article II, Section 7 of the Charter, has adopted the 2021 International Fuel Gas Code,
published by the International Code Council, which shall have the same force and effect as
though set forth in full herein except as amended pursuant to §5-112 of the City Code. The
subject matter of the 2021 International Fuel Gas Code adopted herein includes
comprehensive regulations governing the design, installation, maintenance, alteration and
inspection of fuel gas piping systems, fuel gas utilization equipment and related accessories
for the purposes of protecting public health, safety and general welfare. None of the 2021
International Fuel Gas Code Appendices are hereby adopted.
Section 4. That Section 5-112 of the Code of the City of Fort Collins is hereby repealed
and re-enacted to read as follows:
Sec. 5-112. - Amendments and deletions to the 2021 International Fuel Gas Code.
The 2021 International Fuel Gas Code adopted in § 5-111 is hereby amended as follows:
1. Section 101.1 Title is hereby amended to read as follows:
101.1 Title. These regulations shall be known as the Fuel Gas Code of the City of Fort
Collins, hereinafter referred to as “this code.”
2. Section 102.8 Referenced codes and standards is hereby amended to read as follows:
- 3 -
Section 102.8 Referenced codes and standards. The codes and standards referenced
in this code shall be those that are listed in Section 101.4 of the adopted International
Building Code, entitled “Referenced codes,” and such codes and standards shall be
considered as part of the requirements of this code to the prescribed extent of each such
reference and as further regulated in Sections 102.8.1 and 102.8.2.
Exception: Where enforcement of a code provision would violate the conditions
of the listing of the equipment or appliance, the conditions of the listing and the
manufacturer's installation instructions shall apply.
3. SECTION 103 (IFGC) CODE COMPLIANCE AGENCY is hereby deleted in its
entirety and replaced with the following:
SECTION 103 – CODE ADMINISTRATION
103.1 Entity charged with code administration. The entity charged with code
administration shall be as determined in accordance with Section 103 of the adopted
International Building Code, entitled “CODE ADMINISTRATION.”
4. Section 106.1.1 Annual permit and Section 106.1.2 Annual permit records are
hereby deleted in their entirety.
5. SECTION 109 (IFGC) FEES is hereby deleted in its entirety and replaced with the
following:
SECTION 109 FEES
109.1 Fees. All items relating to fees shall be as specified in Section 109 of the adopted
International Building Code, entitled “FEES.”
6. SECTION 113 (IFGC) MEANS OF APPEAL is hereby deleted in its entirety and
replaced with the following:
SECTION 113 MEANS OF APPEAL.
113.1 General. Appeals of decisions, determinations and interpretations of this code
shall be made pursuant to the applicable provisions of Section 113 of the adopted
International Building Code, entitled “MEANS OF APPEALS.”
7. SECTION 114 (IFGC) BOARD OF APPEALS is hereby deleted in its entirety.
8. Section 115.4 Violation penalties is hereby deleted in its entirety and replaced with
the following:
- 4 -
115.4 Violation penalties. All items related to violation penalties shall be made
pursuant to the applicable provisions of Section 114.4 of the adopted International
Building Code.
9. A new Section 115.4.1 Work commencing before permit issuance is hereby added
to read as follows:
115.4.1 Work commencing before permit issuance. All items related to work
commencing before permit issuance shall be made pursuant to the applicable
provisions of Section 109.2 of the adopted International Building Code.
10. Section 301.3 Listed and labeled is hereby amended to read as follows:
301.3 Listed and labeled. Appliances regulated by this code shall be listed and labeled
for the application in which they are used unless otherwise approved in accordance
with Section 105.
11. Section 303.3 Prohibited locations is hereby amended as follows:
303.3 Prohibited locations. Appliances shall not be located in sleeping rooms,
bathrooms, toilet rooms, storage closets or surgical rooms, or in a space that opens
only into such rooms or spaces, except where the installation complies with one of the
following:
1. The appliance is a direct-vent appliance installed in accordance with the
conditions of the listing and the manufacturer’s instructions.
2. Vented room heaters, wall furnaces, vented decorative appliances, vented gas
fireplaces, vented gas fireplace heaters and decorative appliances for
installation in vented solid fuel-burning fireplaces are installed in rooms that
meet the required volume criteria of Section 304.5.
3. The appliance is installed in a room or space that opens only into a bedroom or
bathroom, and such room or space is used for no other purpose and is provided
with a solid weather-stripped door equipped with an approved self-closing
device. Combustion air shall be taken directly from the outdoors in accordance
with Section 304.6.
4. A clothes dryer is installed in a residential bathroom or toilet room having a
permanent opening with an area of not less than 100 square inches (0.06 m2)
that communicates with a space outside of a sleeping room, bathroom, toilet
room or storage closet.
12. Section 304.11 Combustion air ducts is hereby amended to read as follows:
304.11 Combustion air ducts. Combustion air ducts shall comply with all of the
following:
- 5 -
1. Ducts shall be constructed of galvanized steel complying with Chapter 6 of the
International Mechanical Code or of a material having equivalent corrosion
resistance, strength and rigidity.
Exception: Where the installation of galvanized steel ducts is not practical
due to existing finish materials within dwellings units that are undergoing
alteration or reconstruction, unobstructed stud and joist spaces shall not be
prohibited from conveying combustion air, provided that not more than one
required fireblock is removed.
2. Ducts shall terminate in an unobstructed space allowing free movement of
combustion air to the appliances.
3. Ducts shall serve a single enclosure.
4. Ducts shall not serve both upper and lower combustion air openings where both
such openings are used. The separation between ducts serving upper and lower
combustion air openings shall be maintained to the source of combustion air.
5. Ducts shall not be screened where terminating in an attic space.
6. Horizontal upper combustion air ducts shall not slope downward toward the
source of combustion air.
7. The remaining space surrounding a chimney liner, gas vent, special gas vent or
plastic piping installed within a masonry, metal or factory-built chimney shall
not be used to supply combustion air.
Exception: Direct-vent gas-fired appliances designed for installation in a
solid fuel-burning fireplace where installed in accordance with the
manufacturer’s instructions.
8. Combustion air intake openings located on the exterior of a building shall have
the lowest side of such openings located not less than 12 inches (305 mm)
vertically from the adjoining finished ground level.
9. All combustion air openings or ducts shall be readily identifiable with an
approved label or by other means warning persons that obstruction of such
openings or ducts may cause fuel-burning equipment to release combustion
products and dangerous levels of carbon monoxide into the building.
13. Section 305.1 General is hereby amended to read as follows:
305.1 General. Equipment and appliances shall be installed as required by the terms
of their approval, in accordance with the conditions of listing, the manufacturer’s
instructions and this code. Manufacturers’ installation instructions shall be available
on the job site at the time of inspection. Where a code provision is less restrictive than
the conditions of the listing of the equipment or appliance or the manufacturer’s
installation instructions, the conditions of the listing and the manufacturer’s
installation instructions shall apply.
14. Section 404.12 Minimum burial depth is hereby amended to read as follows:
- 6 -
404.12 Minimum burial depth. Underground piping systems shall be installed a
minimum depth of 18 inches (457 mm) below grade.
15. Section 404.12.1 Individual outdoor appliances is hereby deleted in its entirety.
16. Section 406.4.1 Test pressure is hereby deleted in its entirety and replaced with the
following:
406.4.1 Test pressure. The test pressure to be used for non-welded pipe shall be 10 psi
minimum.
17. Section 501.8 Appliances not required to be vented is hereby amended to read as
follows:
501.8 Appliances not required to be vented. The following appliances shall not be
required to be vented:
1. Electrical ranges.
2. Built-in domestic cooking units listed and marked for optional venting.
3. Hot plates and laundry stoves.
4. Type 1 clothes dryers (Type 1 clothes dryers shall be exhausted in accordance with
the requirements of Section 614).
5. A single booster-type automatic instantaneous water heater, where designed and
used solely for the sanitizing rinse requirements of a dishwashing machine,
provided that the heater is installed in a commercial kitchen having a mechanical
exhaust system. Where installed in this manner, the draft hood, if required, shall be
in place and unaltered and the draft hood outlet shall be not less than 36 inches
(914 mm) vertically and 6 inches (152 mm) horizontally from any surface other
than the heater.
6. Refrigerators.
7. Counter appliances.
8. Direct-fired makeup air heaters.
9. Specialized appliances of limited input such as laboratory burners and gas lights.
Where the appliances listed in Items 5 through 9 are installed so that the aggregate
input rating exceeds 20 British thermal units (Btu) per hour per cubic foot (207 watts
per m3) of volume of the room or space in which such appliances are installed, one or
more shall be provided with venting systems or other approved means for conveying
the vent gases to the outdoor atmosphere so that the aggregate input rating of the
remaining unvented appliances does not exceed 20 Btu per hour per cubic foot (207
watts per m3). Where the room or space in which the appliance is installed is directly
connected to another room or space by a doorway, archway or other opening of
comparable size that cannot be closed, the volume of such adjacent room or space shall
be permitted to be included in the calculations.
18. Section 503.6.6 Minimum height is hereby amended to read as follows:
- 7 -
503.6.6 Minimum height. A Type B or L gas vent shall terminate not less than 5 feet
(1524 mm) in vertical height above the highest connected appliance draft hood or flue
collar. A Type B-W gas vent shall terminate not less than 12 feet (3658 mm) in vertical
height above the bottom of the wall furnace. All gas vents shall terminate a minimum
of 22 inches (559 mm) above the surface or grade directly below.
19. Section 621 (IFGC) UNVENTED ROOM HEATERS is hereby deleted in its
entirety.
20. A new Section 623.3.1 Kitchens with gas cooking is hereby added to read as follows:
623.3.1 Kitchens with gas cooking. Gas cooking appliances in residential kitchens
shall be supplied with an exhaust system vented to the outside. Ducts serving kitchen
exhaust systems shall not terminate in an attic or crawl space or areas inside the
building and shall not induce or create a negative pressure in excess of negative 3 Pa
or adversely affect gravity-vented appliances.
21. Section 630.3 (IFGS) Combustion and ventilation air is hereby amended to read as
follows:
630.3 (IFGS) Combustion and ventilation air. Where infrared heaters are installed,
natural or mechanical means shall provide outdoor ventilation air at a rate of not less
than 4 cfm per 1,000 Btu/h (0.38 m3/min/kW) of the aggregate input rating of all such
heaters installed in the space. Exhaust openings for removing flue products shall be
above the level of the heaters.
Section 5. The City Attorney and the City Clerk are authorized to modify the formatting
and to make such other amendments to this Ordinance as necessary to facilitate publication in the
Fort Collins Municipal Code; provided, however, that such modifications and amendments shall
not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
______________________________
City Clerk
8
Passed and adopted on final reading on this 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_____________________________
City Clerk
ORDINANCE NO. 029, 2021
OF THE COUNCIL OF THE CITY OF FORT COLLINS
AMENDING CHAPTER 5, ARTICLE V, DIVISION 1 OF THE
CODE OF THE CITY OF FORT COLLINS FOR THE PURPOSE
OF AMENDING THE COLORADO PLUMBING CODE
WHEREAS, on March 22, 2011, the City Council adopted Ordinance No. 035, 2011,
adopting the Colorado Plumbing Code (the “CPC”) as published at 3 Colorado Code of
Regulations 720-1, and codified the CPC at Section 5-125 of the Code of the City of Fort Collins,
with local amendments thereto; and
WHEREAS, the CPC applies to and constitutes minimum requirements and standards
governing the inspection, installation, alteration, and repair of the plumbing fixtures, appliances,
and systems throughout the City to protect the health, safety and welfare of the City and its
residents; and
WHEREAS, the City Council has determined that it is in the best interest of the health,
safety and welfare of the City and its residents that the CPC be amended to update the requirements
pertaining to maximum flow and water consumption; and
WHEREAS, pursuant to the City Charter, Article II, Section 7, City Council may enact
any ordinance which adopts a code by reference in whole or in part provided that before adoption
of such ordinance the Council hold a public hearing thereon and that notice of the hearing shall
be published twice in a newspaper of general circulation published in the City, with one of such
publications occurring at least eight (8) days preceding the hearing and the other publication
occurring at least fifteen (15) days preceding the hearing; and
WHEREAS, in compliance with City Charter, Article II, Section 7, the City Clerk
published in the Fort Collins Coloradoan such notice of hearing concerning adoption of the
2021 International Codes on January 30, 2022, and February 6, 2022; and
WHEREAS, attached as Exhibit “A” and incorporated herein by reference is the Notice of
Public Hearing dated January 24, 2022, that was so published and which the Council hereby finds
meets the requirements of Article II, Section 7 of the City Charter.
NOW, THEREFORE, BE IT ORDAINED BY THE COUNCIL OF THE CITY OF FORT
COLLINS as follows:
Section 1. That the City Council hereby makes and adopts the determinations and
findings contained in the recitals set forth above.
Section 2. That Section 5-126 of the Code of the City of Fort Collins is hereby
amended to read as follows:
Sec. 5-126. - Amendments and deletions to the Colorado Plumbing Code.
The Colorado Plumbing Code as adopted is hereby amended in the following respects:
1. Section 604 and TABLE 604.4 of the International Plumbing Code, as adopted by
the Colorado Plumbing Code, are hereby amended to read as follows:
604.4 Maximum flow and water consumption. The maximum water consumption
flow rates and quantities for all plumbing fixtures and fixture fittings shall be in
accordance with Table 604.4 and such fixtures and fittings shall be Environmental
Protection Agency (EPA) WaterSense® labeled fixtures, excluding fixtures and fixture
fittings that are not labeled under the WaterSense® program.
TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS
Plumbing Fixture or Fixture Fitting Maximum Flow Rate of Quantityb
Lavatory faucet, private 0.5 gallon per minute at 60 psi for non-residential
occupancy
1.5 gallons per minute at 60 psi for R and I
Lavatory, faucet public (metering) 0.25 gallon per metering cycle
minimum 10 second cycle setting for water run time Shower head a (includes handheld) 1.8 gallons per minute at 80 psi
2.0 gallons per minute at 80 psi for I and E occupancies
Sink faucet 1.8 gallons per minute at 60 psi
Urinal 0.5 gallons per flushing cycle
Residential Water closet 1.1 gallons per flushing cycle, with minimum MaP (solid-
waste removal performance threshold) of 600 grams. Dual
Flush gallons per flushing cycle: Average of three flushes
(two reduced flushes and one full flush)
Commercial Water Closet 1.28 gallons per flushing cycle, with minimum MaP (solid-
waste removal performance threshold) of 600 grams. Dual
Flush gallons per flushing cycle: Average of three flushes
(two reduced flushes and one full flush)
Pre-rinse Spray Valves (food service) Must meet federal Department of Energy WaterSense®
criteria per 10 CFR 431, subpart O.
Bar sinks (food service) 2.2 gallon per minute at 60 psi
For SI: 1 gallon = 3.785 L, 1 gallon per minute = 3.785 L/m,
1 pound per square inch = 6.895 kPa.
a. A hand-held shower spray is a shower head.
b. Consumption tolerances shall be determined from referenced standards.
Section 3. The City Attorney and the City Clerk are authorized to modify the
formatting and to make such other amendments to this Ordinance as necessary to facilitate
publication in the Fort Collins Municipal Code; provided, however, that such modifications and
amendments shall not change the substance of the Code provisions.
Introduced, considered favorably on first reading, and ordered published this 15th day of
February, A.D. 2022, and to be presented for final passage on the 5th day of April, A.D. 2022
__________________________________
Mayor
ATTEST:
_______________________________
City Clerk
Passed and adopted on final reading on the 5th day of April, A.D. 2022.
__________________________________
Mayor
ATTEST:
_______________________________
City Clerk