Loading...
HomeMy WebLinkAbout1/9/2020 - Zoning Board Of Appeals - Agenda - Jan 2020 AgendaRalph Shields, Chair Shelley LaMastra, Vice Chair John McCoy Taylor Meyer Ian Shuff Butch Stockover Council Liaison: Ross Cunniff Staff Liaison: Noah Beals LOCATION: City Council Chambers 300 LaPorte Avenue Fort Collins, CO 80521 The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224-6001) for assistance. REGULAR MEETING JANUARY 9, 2020 8:30 AM • CALL TO ORDER and ROLL CALL • APPROVAL OF MINUTES FROM PREVIOUS MEETING • CITIZEN PARTICIPATION (Items Not on the Agenda) • APPEALS FOR VARIANCE TO THE LAND USE CODE 1. APPEAL ZBA190049 Address: 710 W. Mulberry Street Owner/Petitioner: Jesse Struckhoff Zoning District: N-C-M Code Section: 4.8(E)(3) Project Description: The variance request is to allow an attached carport to encroach 14.5 feet into the required 15 foot rear- yard setback. 2. APPEAL ZBA190050 Address: 224 W. Harmony Road Owner: Moreland Properties LLC Petitioner: Mark Bruder, Schlosser Signs Zoning District: C-G Code Section: 3.8.7.2 (G) Table (G)(2) Project Description: This is a variance request to install a 12 foot tall free-standing sign encroaching 11 feet into the required 15 foot setback from the public right-of-way. ZONING BOARD OF APPEALS AGENDA Zoning Board of Appeals Page 2 January 9, 2020 3. APPEAL ZBA190051 Address: 1418 West Oak Street Owner: Barbara Hoehn Petitioner: Jeff Gains, HighCraft Builders Zoning District: N-C-L Code Section: 4.7(D)(2)(a)3.; 4.7(F)(1)(e), Project Description: This is a request to build an accessory structure that will include both a garage and habitable space and requires two variances. The first variance is to allow an additional 503 sq ft of floor area to the lot when the maximum floor area allowance is 4,525 sq ft. The second variance is to allow a 2-story accessory structure when only a 1 1/2 story is permitted. Code requires 40% of the floor area of the "2nd story" should have a ceiling height of less than 5 feet. This proposal would have 0% under 5 feet. 4. APPEAL ZBA190052 Address: 132 Bryan Avenue Owner: Holly E Field Trust Petitioner: Holly Field Zoning District: N-C-L Code Section: 4.7(E)(2) Project Description: The variance request is to allow a covered porch to encroach 2 feet into the required 15 foot front yard setback. • OTHER BUSINESS • ADJOURNMENT Ralph Shields, Chair Shelley La Mastra, Vice Chair Bob Long John McCoy Taylor Meyer Ian Shuff Butch Stockover Council Liaison: Ross Cunniff Staff Liaison: Noah Beals LOCATION: City Council Chambers 300 LaPorte Avenue Fort Collins, CO 80521 The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224-6001) for assistance. REGULAR MEETING DECEMBER 12, 2019 8:30 AM • CALL TO ORDER and ROLL CALL • APPROVAL OF MINUTES FROM PREVIOUS MEETING Stockover made a motion, seconded by Shuff, to approve the November 14, 2019 Minutes. The motion was adopted unanimously with Long abstaining. • CITIZEN PARTICIPATION (Items Not on the Agenda) • APPEALS FOR VARIANCE TO THE LAND USE CODE 1. APPEAL ZBA190046 – APPROVED Address: 515 Cowan Street Owner/Petitioner: Allison Shaw & Arjanus De Bruijn Zoning District: C-L Code Section: 3.8.3 Project Description: The variance is to store bicycles in an accessory building as part of a home occupation. Home occupations are required to operate from the primary building, not an accessory building. Staff Presentation: Beals showed slides relevant to the appeal and discussed the variance request, noting just north of this property are some commercial properties operating in structures that were originally residential. This proposal is for the owner to still live in the primary structure and have the bikes for their business stored in the garage, separate from the house. There is also a trailer stored on the property for hauling the bicycles to other locations. Bike rental customers do not come to this property, they are rented from other locations, this site is only for storage. The main purpose of the standards is to reduce the impact of a business in a residential neighborhood. Home occupation specifies that the owner must reside on the property and that is the case in this variance. ZONING BOARD OF APPEALS MEETING MINUTES Zoning Board of Appeals Page 2 December 12, 2019 Applicant Presentation: Allison Shaw, 515 Cowan Street, addressed the board. This business is not much of a business, they just started this endeavor last spring, they have not made any money and they are not quitting their regular jobs. This is a fun activity for them, they also offer free rides to the public periodically. The applicants are hoping to be able to store their approximately 20 bicycles in the trailer and garage. If they are not granted the variance they will be storing the bikes in their basement, which is challenging because of their toddler. Ms. Shaw does not think this is abnormal behavior for residents to store bikes in a garage or to have a trailer, a lot of their neighbors do as well. Once the bikes are stored they are not visible. They bought their house a couple of years ago, and there is no indication on the house that this is also a business. Audience Participation: Beals did receive one phone call from a neighbor regarding this variance request. The neighbor owns one of the businesses to the north of this property. Their concern was that the owners were running the whole house as a business and wanted to know if this property would be charged utilities as a business. Beals clarified this is a still a home and as a home occupation they would still be charged residential rates for utilities. Vice Chair LaMastra asked if they are storing the bicycles in the garage and in the trailer. Ms. Shaw confirmed this is the case. LaMastra inquired if there is a limit to how much this storage can expand, are there a certain number of trailers that are too many, and do they cap the number of bikes that can be stored on the property. Beals confirmed this board can put conditions on the motion to limit the expansion. Home occupations in general are not supposed to take more than 50% of the primary structure. Vice Chair LaMastra asked if they are parking vehicles in the garage as well. Ms. Shaw confirmed the same. They are filling the trailer with bicycles first and then using the garage as overflow. Board discussion regarding the trailer versus the garage, they are both entities other than the primary residence. Board Discussion: Long brought up previous variances they have seen that are similar to this one – constructing and selling banjo’s, retail knitting sales out of a garage, etc. This is not the applicant’s primary business, other communities wouldn’t even require a variance for this. Long supports the code but also supports a board that understands this is reasonable, especially adjacent to other businesses. Long supports the variance. Meyer said that it may not appear as a business today, but this could grow. Would this be a different discussion if there were 100 bikes versus 20 bikes? Long stated they would have to find different circumstances if that were the case, it would not be sustainable to keep the business there, the owner would need to hire staff and the business would expand elsewhere. Boardmember Shuff made a motion, seconded by Long, to approve ZBA190046 under section 2.10.2(H), on the criteria that the variance is not detrimental to the public good, the C-L zone district allows for a mix of uses, on the same block face other residential structures have been converted to nonresidential uses, the bicycles will be stored completely within the garage or trailer, and the use of the garage does not exceed 50% of floor area of the primary structure. Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way, when considered in the context of the neighborhood, and will continue to advance the purpose of the Land Use Code as contained in Section 1.2.2. Yeas: Stockover, Meyer, Long, Shields, Shuff, McCoy, LaMastra. Nays: none. THE MOTION CARRIED, THE ITEM WAS APPROVED. 2. APPEAL ZBA190047 – APPROVED Address: 1736 Concord Drive Owner/Petitioner: Devin A. Martinez Zoning District: R-L Code Section: 4.4(D)(2)(c) Project Description: The variance is for a proposed accessory building to encroach 5 feet into the required 15 foot rear- yard setback. Zoning Board of Appeals Page 3 December 12, 2019 Staff Presentation: Beals showed slides relevant to the appeal and discussed the variance request, noting this is a corner lot. The primary structure faces west and the abutting property to the east faces south. The shared property line is a side setback for the property on the east, and for the subject property it is a rear setback. In this zone district, when it was approved, there were different side setbacks than typical in the R-L district. The side setbacks are currently 7 feet, and the rear setbacks remain the standard 15 feet. The placement of the proposed structure would be on the northeast side of the property, meeting the 7 foot setback of the north property line, but encroaching 5 feet into the 15 foot rear property setback. The structure itself is one story in height and would be about 12 feet in length that would be encroaching into the setback. Applicant Presentation: Devin Martinez, 1736 Concord Drive, addressed the board. This is not a hardship, not something they have to do. However, their house is not very big, they’ve completed an addition once already. They do not move because they love the neighborhood and their neighbors. The house does not have a basement, just a crawl space. They’d like this as a livable space, some place for the kids to hang out and probably include a murphy bed for family visits. Mr. Martinez has been in real estate his entire career, they will ensure the structure is done correctly and it will add to the value of the property and neighborhood. They have considered the neighbors and they have hired a landscape architect. Chair Shields requested elevations to review. Mr. Martinez explained they do have elevations, but unfortunately he did not bring them. Vice Chair LaMastra asked if there would be a restroom in the accessory structure. Mr. Martinez explained the space would be insulated and conditioned, but no restroom. Discussion regarding the eave height and wall height. Mr. Martinez doesn’t know, doesn’t want the building to be obtrusive, but would prefer higher or vaulted ceilings for market value. It would not be taller than the closest portion of the primary structure. Beals confirmed there are limits that will be put in place during the permitting process. Audience Participation: (none) Board Discussion: Shuff stated the nature of the corner lot makes the rear yard setback greater than a typical lot, he considers this a reasonable request. Chair Shields agreed, they see these requests often. The applicant is still maintaining a 10 foot setback which should be sufficient. LaMastra stated this works well, also the landscape plan illustrates plenty of evergreens surrounding the accessory building. There is to some degree a level of hardship on this type of lot. Boardmember Shuff made a motion, seconded by Meyer, to approve ZBA190047 under section 2.10.2(H), in that the variance is not detrimental to the public good, the abutting neighbor has a 7 foot setback from the shared property line, the width of the encroachment is 12 feet, the accessory structure is one story. Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way, when considered in the context of the neighborhood, and will continue to advance the purpose of the Land Use Code as contained in Section 1.2.2. As a board they feel the nature of the corner lot of the side yard versus rear yard setback is considered. Yeas: Stockover, Meyer, Long, Shields, Shuff, McCoy, LaMastra. Nays: none. THE MOTION CARRIED, THE ITEM WAS APPROVED. 3. APPEAL ZBA190048 – APPROVED Address: 821 W. Mountain Avenue Owner: Jim & Jane Grant Petitioner: Jeff Gaines, High Craft Builders Zoning District: N-C-L Code Section: 4.7(E)(4); 4.7(F)(2)(b)2. Project Description: The variance is to modify an existing garage. The proposed modifications will increase the wall height to 14.75 feet of an existing building that encroaches into the 5 foot required side-yard setback by 3.5 Zoning Board of Appeals Page 4 December 12, 2019 feet. Additionally, the proposal increases the eave height to 14.75 feet, the required eave height is 10 feet. Staff Presentation: Beals showed slides relevant to the appeal and discussed the variance request, noting there is an existing primary building and existing garage already on the property. The request is to modify the current garage, taking the roof and rotating it so the gable ends faces towards the side property lines and not towards the alley and the house. The variance request is required because when the structure was originally built it was about 1.5 feet from the property line. The original house on the property was scraped in 2007 and rebuilt, but the original garage was not scraped, just remodeled so it still did not meet the setback. Code also limits the eave height that faces the side lot line which is different now that the roof is being rotated and artistic elements are being added. The building will still be used as a garage. There is a wall that would be expanded along the south end, but only to add a pergola. Since it’s not a carport that does not count towards the floor area. The outside walls of the structure do not change in footprint size or location. The accessory structure does abut another accessory structure, therefore the impact may be minimal. Vice Chair LaMastra inquired if the existing garage currently meets the eave height requirement. Beals confirmed it does currently meet the eave height requirement, just not the setback requirement. Applicant Presentation: Jeff Gaines, 429 S. Howes Street with High Craft Builders, addressed the board. The homeowners purchased this property over the summer and approached High Craft Builders about expanding the garage. At that time, Jeff approached the city zoning department and learned there had already been a variance on this property around 2007 when the house was built for the increase in square footage. It was clear it would not be reasonable to ask for another floor area variance. After discussing with the homeowners it became clear their goal was to give the building more presence in the backyard to create a nice backdrop for the house. They want the garage to be a playful structure that felt more like a cottage in the backyard even though it would remain a 2-car garage. The grade drops off about 4 feet from the house back so the existing building sits low relative to the house. The view from the house looks down onto the ridge of the accessory building, so the owners want to increase the roof height and change the direction of the gable. There is no change to the footprint or volume of the garage. On the building height variance, the limit for an accessory building without habitable space is 10 feet, so the increased height is a triangular area of about 4 feet 9 inches above the 10 foot mark. The homeowners are considering bringing water service out to the building, which would change it to an accessory building with habitable space, and the starting height would be 13 feet. Then the difference would only be 1 foot, 9 inches. Another benefit of rotating the gable would be the southern exposure towards the alley since the homeowners are considering adding solar panels in the future. There are other garages currently in the alley that are larger and do not meet the accessory building requirements. LaMastra asked why the homeowners want the water service. Mr. Gaines confirmed it would be hose access for watering the landscape. Audience Participation: (none) Board Discussion: Shuff stated the eave height is still low on the north and south ends. If they did bring water service to this building, the variance is only for 1 foot 9 inches. This is a fairly common zoning request and more of a design element in moving the gable orientation. He acknowledges the close lot line, but does not have a problem with the variance. McCoy stated the drawings look like a house and inquired if they can build a separate habitable space in this zoning district. Beals clarified they could have habitable space, he would have to calculate if the lot size was sufficient for an additional dwelling unit. However, all of the floor plans regarding this structure reflect a garage. His understanding is that the owners just want to change the look of the structure. Nothing they have seen indicates habitable space. McCoy asked if there are utilities in the alley for water and sewer. Mr. Gaines responded the sewer access is located on Mountain Avenue, based on where the sewer comes out of the house basement it might even be impossible to have a connection to this garage. All of the elements that make this appear like a house are purely ornamental. The volume remains for a garage, there is no loft space inside. LaMastra agreed with McCoy’s statement, the structure appears to be a house, even has a chimney. Zoning Board of Appeals Page 5 December 12, 2019 Chair Shields stated he would approve the variance, especially based on the context of the alley. Boardmember Long made a motion, seconded by LaMastra, to approve ZBA190048 for the following reasons: the variance is not detrimental to the public good, the increase eave height is 14.5 feet in width of the building and tappers to zero feet, the overall wall increase is 40 square feet, and the proposed changes do not include a window on the west side. Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way, when considered in the context of the neighborhood, and will continue to advance the purpose of the Land Use Code as contained in Section 1.2.2. Yeas: Stockover, Meyer, Long, Shields, Shuff, McCoy, LaMastra. Nays: none. THE MOTION CARRIED, THE ITEM WAS APPROVED. • OTHER BUSINESS • ADJOURNMENT Ralph Shields, Chairperson Noah Beals, Senior City Planner-Zoning Agenda Item 1 Item # 1 - Page 1 STAFF REPORT January 9, 2020 STAFF Noah Beals, Senior City Planner/Zoning PROJECT ZBA190049 PROJECT DESCRIPTION Address: 710 W Mulberry Street Petitioner/Owner: Jesse Struckhoff Zoning District: N-C-M Code Section: 4.8(E)(3) Variance Request: The variance request is to allow an attached carport to encroach 14.5 feet into the required 15 foot rear-yard setback. COMMENTS: 1. UBackground:U The property was annexed into the City in 1887 as part of the Loomis annexation. The original plat did not include two separate parcels that fronted onto Mulberry. It is assumed these two parcels were created at or near the time the primary building was built in 1910. In general, the purposes of setbacks, but not limited to, are to preserve neighborhood character, provide safe passage for first responders and create separation for privacy. For this property the 15 foot rear setback is the north property line. The abutting property to the north along the shared property line has a 5 foot side setback. 2. UApplicant’s statement of justification:U See petitioner’s letter. 3. UStaff Conclusion and Findings:U Under Section 2.10.2(H), staff recommends denial and finds that: • The 14.5 feet of encroachment more than doubles a nonconformity on the property and creates a perceived 0 foot setback. • Insufficient evidence has been provided in establishing a unique hardship to the property as there is covered parking already on the site. • Insufficient evidence has been provided in showing how the proposal supports the standards in a way equally well or better than a proposal that complies with the standards. 4. URecommendation: Staff recommends denial of APPEAL ZBA190049. JFort —OtyoC Collins tl Application Request for Variance from the Land Use Code The Zoning Board of Appeals has been granted the authority to approve variances from the requirements of Articles 3 and 4 of the Land Use Code. The Zoning Board of Appeals shail not authorize any use in a zoning district other than those uses which are specificaily permitted in the zoning district. The Board may grant variances where it finds that the modification of the standard would not be detrimental to the public good. Additionally, the variance request must meet at least one of the following justification reasons: (1) by reason of exceptional physical conditions or other extraordinary and exceptional situations unique to the property, including, but not limited to physical conditions such as exceptional narrowness, shallowness, or topography, the strict application of the code requirements would result in unusual and exceptional practical difficulties or undue hardship upon the occupant/applicant of the property, provided that such difficulties or hardship are not caused by an act or omission of the occupant/applicant (i.e. not self-imposed); (2) the proposal will promote the general purpose of the standard for which the variance is requested equally well or better than would a proposal which complies with the standard for which the variance is requested; (3) the proposal will not diverge from the Land Use Code standards except in a nominal. Inconsequential way when considered in the context of the neighborhood. This application is only for a variance to the Land Use Code. Building Code requirements will be determined and reviewed by the Building Department separately. When a building or sign permit Is required for any work for which a variance has been granted, the permit must be obtained within 6 months of the date that the variance was granted. However, for good cause shown by the applicant, the Zoning Board of Appeals may consider a one-time 6 month extension if reasonable and necessary under the facts and circumstances of the case. An extension request must be submitted before 6 months from the date that the variance was granted has lapsed. Petitioner or Petitioner’s Representative must be present at the meeting Location: 300 LaPorte Ave, Council Chambers, Fort Collins, CO 80524 Date: Second Thursday of the month Time: 8:30 a.m. Variance Address 710 W Mulberry St. Petitioner's Name, If not the Owner City Fort Collins, CO Petitioner's Relationship to the Owner is Zip Code 180521 Petitioner's Address Owner's Name iJesse Struckhoff Petitioner's Phone # I Code Section(s) Set Back Petitioner's Email Zoning District lOld Town West Additional Representative's Name Justification(s) 1. Hardship Representative's Address Justification(s) |2. Equal to or better than Representative's Phone # I Justification(s) 3. Nominal and inconsequential Representative's Email Reasoning If not enough room, additional written information may be submitted Hardship: Current driveway and shop are within 2 feet of the property line. Set back of 15 feet does not exist. Equal to or better than: Will provide covered parking and and aesthetic barrier. Provide barrier to neighbor's structures. Nominal impact: Due to lot size (1/2 lot), current code set backs would prohibit this type of imorovement. This structure will be on the backside of house and not visible from Mulberry. Date 12-3-19 Signature _ Dear FC Zoning Department, Thank you in advance for taking the time to review my variance request. The purpose for my request is to see zoning approval to build a carport of the north end of my property. The lot on which my house was build was a divided lot. The front of my house faces Mulberry. There is a garage on the mulberry side that is shared via common wall with my neighbor to the east. In addition, the driveway off of mulberry is shared. Therefore, the primary ingress and egress from my home is from the north in which I have a concrete driveway on the north end of house which continues to the west end along the alley. As part of a larger home renovation I plan to begin in spring 2020, I would like to add a car port along the north side of my house. The car part will effectively cover 30 ft. of the driveway and create sheltered parking and outside area. The challenge is the property line to the north is only 1’8” from the edge of the driveway. Therefore, if I add a carport, the support posts would be approx. 2 ft. from the fence line. However, this would be in line with an existing shop structure that is connected to the shared garage. Due to the unique split lot situation, I do not have an alternative location in which to locate the car port. Aesthetically, the car port would not be seen from the front facing (Mulberry) side. Allowing this variance would make the driveway much more usable with no impact to adjoining properties. As a side note, the adjoining property already has several outbuildings directly against the fence. I have reviewed the concept with the building department and discussed the requirement to use fire rated materials due to lot line proximity. Again, Thank you for reviewing the variance request and please let me know if I can provide additional information. Thank you, Jesse Struckhoff 710 W Mulberry St., Fort Collins, CO 80521 jessestruckhoff@gmail.com 710 W. Mulberry Car Port Proposal - Setback Variance : ^ ' "~h- 1 Neighbors sheds Existing 6 fence. :f Existing garage Existing garage with common wall shared with neighbor to the east Proposed Car Port ' -T* liv Specs: • Property Sq Ft is 4,356 • House Sq Ft is 1788 (main level and'bso^) c3 r 2 £ •T 0 < i Agenda Item 2 Item # 2 - Page 1 STAFF REPORT January 9, 2020 STAFF Noah Beals, Senior City Planner/Zoning PROJECT ZBA190050 PROJECT DESCRIPTION Address: 224 W. Harmony Road Owner: Moreland Properties LLC Petitioner: Mark Bruder, Schlosser Signs Zoning District: C-G Code Section: 3.8.7.2 (G) Table (G)(2) Variance Request: This is a variance request to install a 12 foot tall free-standing sign encroaching 11 feet into the required 15 foot setback from the public right-of-way. COMMENTS: 1. UBackground:U The property recently redeveloped from a vacant warehouse to a car dealership. The redevelopment included many site changes including parking layout, building expansion and landscaping. In between the time of approval and construction of the dealership there were alterations to the approved plan. In general sign standards are to reduce both sign clutter and driver distractions. The overall height of a sign is permitted to increase as it is setback further from the public right-of-way. 2. UApplicant’s statement of justification:U See petitioner’s letter. 3. UStaff Conclusion and Findings:U Under Section 2.10.2(H), staff recommends denial and finds that: • This is a new sign and not a relocation of an existing sign. • Insufficient evidence has been provided to determine if the proposal is not detrimental to the public good. • Insufficient evidence has been provided in establishing a unique hardship to the property that would prevent a design to be in compliance with the standard. It appears the base of the sign can be reduced in height. • Insufficient evidence has been provided in showing how the proposal supports the standards in a way equally well or better than a proposal that complies with the standards. 4. URecommendation: Staff recommends denial of APPEAL ZBA190050. 2-STORY METAL BUILDING W/ ADD-ONS APPROX. 31,553 S.F. FINISHED FLOOR = 5045.9 S S S S S S W W W W W W W W W W S S S S S S S S W W W W W W W W W W W W W S S S S S E E E E G G G E E E E E E E E E OIL AND SAND INTERCEPTOR (SEE DETAIL SHEET C-15) 6" - 90° BEND 6" WET TAP W/ TB FIRELINE W W W W S S S S S S S S S S S S S M S S S S S S W W W W W W W W 59' 158 LF ~ 6" DIP 100 LF ~ 6" PVC CURB CORP STOP STOP 175 LF~TYPE ~ 1 1/2" TYPE 'K' COPPER 1-1/2" METER 19 LF ~ 6" DIP This unofficial copy was downloaded on Oct-09-2019 from the City of Fort Collins Public Records Website: http:/citydocs.fcgov.com For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA This unofficial copy was downloaded on Oct-09-2019 from the City of Fort Collins Public Records Website: http:/citydocs.fcgov.com For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA Right-of-Way Property Line This unofficial copy was downloaded on Oct-09-2019 from the City of Fort Collins Public Records Website: http:/citydocs.fcgov.com For additional information or an official copy, please contact Engineering Office 281 North College Fort Collins, CO 80521 USA Agenda Item 3 Item # 3 - Page 1 STAFF REPORT January 9, 2020 STAFF Noah Beals, Senior City Planner/Zoning PROJECT ZBA190051 PROJECT DESCRIPTION Address: 1418 West Oak Street Owner: Barbara Hoehn Petitioner: Jeff Gains, HighCraft Builders Zoning District: N-C-L Code Section: 4.7(D)(2)(a)3.; 4.7(F)(1)(e) Variance Request: This is a request to build an accessory structure that will include both a garage and habitable space and requires two variances. The first variance is to allow an additional 503 sq ft of floor area to the lot when the maximum floor area allowance is 4,525 sq ft. The second variance is to allow a 2-story accessory structure when only a 1 1/2 story is permitted. Code requires 40% of the floor area of the "2nd story" should have a ceiling height of less than 5 feet. This proposal would have 0% under 5 feet. COMMENTS: 1. UBackground:U The property annexed into the City in 1907 as part of the Scott Sherwood Addition. The primary structure was built later in 1924. A garage was built the following year in 1925. This garage existed on site until 2019, after it had deteriorated and was demolished. Since 1925, the N-C-L zone district has been established and design standard created. The purpose of the standards, in general but not limited to, are to preserve the character of the neighborhood, limit looming structures, and reduce building impacts on adjoining neighbors. 2. UApplicant’s statement of justification:U See petitioner’s letter. 3. UStaff Conclusion and Findings:U Under Section 2.10.2(H), staff recommends approval for an additional 503 square feet and finds that: • The variance is not detrimental to the public good. • An accessory building existed on the property up to last year. • The new accessory building will be meet the required setbacks. Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way, when considered in the context of the neighborhood, and will continue to advance the purpose of the Land Use Code as contained in Section 1.2.2 Further, staff recommends denial of variance from the definition of half-story and finds: • The demolished nonconforming structure was a one-story structure. • Insufficient evidence has been provided in establishing a unique hardship to the property. • Insufficient evidence has been provided in showing how the proposal supports the standards in way equally well or better than a proposal that complies with the standard. 4. URecommendation: Staff recommends approval for one request and denial of the other of APPEAL ZBA190051. 1418 West Oak St. Variance Request Explanation This variance request seeks the following modifications to Fort Collins NCL district standards for a proposed accessory building with habitable space: ● Exceeding the lot maximum FAR: Per LUC 4.7(D)(3), 4,275 square feet are allowable on this 14,250 square foot lot. The existing two story principal building is 4,428 square feet. The floor area of the proposed accessory is 600 square feet, resulting in an excess floor area of 503 square feet on the lot (after 250 square foot detached accessory reduction). ● Exceeding the one and one-half (1.5) story height limitation for accessory buildings: Per LUC 4.7(F)(1)(e), and several other references in the NCL requirements, accessory buildings are limited to 1.5 stories in height. The LUC defines a half story as follows: “Story, half shall mean a space under a sloping roof which has the line of intersection of the roof and wall face not more than three (3) feet above the floor level, and in which space the possible floor area with head room of five (5) feet or less occupies at least forty (40) percent of the total floor area of the story directly beneath.” The proposed structure has an intersection of roof and wall face at 7’-5 3/4” above floor level, and useable upper floor area of 360 square feet, excluding the stairway, which equates to 60 percent of the area of the story beneath. Likewise, unusable stairway space (90 square feet) and outdoor roof deck space (150 square feet) together constitute 40 percent of the area of the story beneath. Project Description: The homeowner would like to build a new, detached garage in the rear portion of the property to replace the property’s original 1925 garage. A 210 square foot carport attached to the garage was demolished in 1980, and the 465 square foot garage was demolished in 2019. Plans developed for this replacement structure provide for a two car garage space, as well as an interior stairway accessing a small art studio space and adjoining roof deck at the upper level. While the LUC allows space with ceiling height under 7’-6” to be added above accessory buildings without contributing to FAR, the LUC generally assumes that the design will incorporate some form of a high slope roof with dormers. In this case, the homeowner wishes to create a space of this type above the garage, equivalent to what might generally be allowed by the code, but to do so in a way that compliments and ties in with the property’s unique 1924 Mediterranean Revival home. This home consists of a stuccoed, two story volume, with a low slope hipped roof. The proposed accessory design features a similar straightforward form, with a low slope hipped roof set above a short upper floor. As described, the proposed useable area of 360 square feet for this upper floor is equivalent to the ratio of high ceiling space allowed by the LUC half story standard. A 90 square foot indoor stairway adds both to this upper floor space and to the first floor area. While this stair access could be placed on the outside of the building and not contribute to its floor area or interior size, doing so would create a safety issue for the aging homeowner and would be incongruent with the simplicity of the building and goal of the LUC to shield upper level entrance accesses from neighboring properties. Justification Criteria 1 – By reason of exceptional physical condition or situation unique to the property, the strict application of the code requirements would result in undue hardship: Strict application of the lot FAR standard would preclude construction of a new detached accessory building on this lot due to the size of the 1924 principal building in relation to current code standards. Justification Criteria 2 - The proposal will promote the general purpose of the standard for which the variance is requested equally well or better than would a proposal which complies with the standard for which the variance is requested: The general purpose of the half story requirement for an accessory building is to limit its height and massing to a scale that is appropriate for rear lot density, prevents looming over neighboring yards, and establishes a clear subordinance to the principal building. Unusually large lot size, resulting openness of the rear half of the lot, generous proposed setbacks, proposed building form, and size of the principal building all contribute to this proposal promoting the general purpose of the 1.5 story standard: ● This double-lot is unusually large for the district in having a width of 75 feet, and area of 14,250 square feet. With the existing house situated almost entirely in the front half of the lot, the rear lot density resulting from this accessory would be well below the 25 percent maximum in the NCL district at about 12 percent. ● The proposed accessory would be set back 12’ from the west side lot line, 26.5’ from the east side lot line, and 24.5’ from the alley. These generous setbacks bring eave heights within the requirements outlined in 4.7(F)(2)(b) to prevent looming. Likewise, the 21’-1” ridge height of the proposed accessory is within the 24’ limit outlined in 4.7(F)(2)(b). An illustration has been attached with this request depicting the massing of the proposed design in relation to an envelope starting at a 13’ wall height (3’ above second floor height), and continuing to a peak at 24’. In pared down form, this envelope represents the allowable massing described for this building by the half story requirement. Considering the volume carved out by the proposed roof deck and the fact that the LUC has allowance for additional raised dormers that could add to the depicted envelope, this illustration demonstrates that the proposed structure is of equivalent or lesser bulk than one meeting the half story requirement. ● The majority of upper level glazing faces the house (south elevation) and roof deck towards the lot interior (west elevation). Minimal glazing faces the west abutting lot, and the larger of these windows is located high above the stair as depicted in Building Section 1/Sheet A1.2. In general, the proposal minimizes glazing facing abutting properties in a manner consistent with a design meeting the goals of 4.7(F)(3)(c)(2). ● The principal building has a floor plate of 2,214 square feet on each story, and total area of 4,428, making it unusual for its size. As noted, the proposed accessory would have a first floor area of 600 square feet, and upper level area of 450 square feet (including stairway). A clear size hierarchy would exist between structures. Justification Criteria 3 - Proposal will not diverge from the standard except in a nominal, inconsequential way when considered in the context of the neighborhood: While the existing principal building is unusually large in floor area, it is compact in form and generally positioned within the front half of the lot. As noted, the rear of the lot would be well within density requirements, and given the large size of the lot and relatively low lot coverage that would result from both buildings, it is unlikely that the proposed increase in lot FAR would feel inconsistent with the surrounding neighborhood.                       /27   /27        5($5+$/)       :(672$.675((7 $//(< 3$7,2 1" = 20'-0" ^/dW>E E ,K,E^^KZzh/>/E't/d,/E,/d>^W ϭϰϭϴt^dK<^dZd͕&KZdK>>/E^K>KZKϴϬϱϮϭ ),567    6(&21'    %($5,1*    3($.    0$;+(,*+7            ,17(5,256,'(3523(57</,1( WZϰ͘ϳ͕&͕Ϯ͕͕ϭ͗Dys,/',dϭϯΖͲϬΗ WZϰ͘ϳ͕&͕Ϯ͕͕ϯ͗s,/',dE /EZ^dZd/KK&ϲ/E,^WZ ,ϭ&KKdK&^d<&ZKDd, /EdZ/KZ^/WZKWZz>/E͘ ϭϯΖͲϬΗнϯΖͲϲΗ;ϰϮΗͿсϭϲΖͲϲΗ>>Kt> s,/',dϭϮ&d&ZKDWZKWZdz>/E   0,1,0806,'(6(7%$&.     1/4" = 1'-0" ^Khd,>sd/KE ,K,E^^KZzh/>/E't/d,/E,/d>^W ϭϰϭϴt^dK<^dZd͕&KZdK>>/E^K>KZKϴϬϱϮϭ />>h^dZd/KE͗Dy/DhD>>Kt>s,/',dWZ>hϰ͘ϳ͕&͕Ϯ͕͕ϯ ,K,E^^KZzh/>/E't/d,/E,/d>^W ϭϰϭϴt^dK<^dZd͕&KZdK>>/E^K>KZKϴϬϱϮϭ />>h^dZd/KE͗WZKWK^^^KZzh/>/E'D^^/E't/d,/E>>Kt>h/>/E'Es>KWWZ/s/^/KEϰ͘ϳ s/t&ZKD^Khd,t^d s/t&ZKDEKZd,^d s/t&ZKD^Khd,^d s/t&ZKDEKZd,t^d                       /27   /27        5($5+$/)       :(672$.675((7 $//(< 3$7,2                                   $ ϯ ϰ ϰ                  ),567    6(&21'    %($5,1*    3($.     $  $  $ ϭϮ ϱ Ϯ                  0$;+(,*+7    ),567    6(&21'    %($5,1*    3($.     $            $   $ ϳ ϭ ϱ           $   $ ϴ            $  $  ),567  Agenda Item 4 Item # 4 - Page 1 STAFF REPORT January 9, 2020 STAFF Noah Beals, Senior City Planner/Zoning PROJECT ZBA190052 PROJECT DESCRIPTION Address: 132 Bryan Avenue Owner: Holly E Field Trust Petitioner: Holly Field Zoning District: N-C-L Code Section: 4.7(E)(2) Variance Request: The variance request is to allow a covered porch to encroach 2 feet into the required 15 foot front yard setback. COMMENTS: 1. UBackground:U The property was annexed into the City in 1924 and platted the following year. The primary structure was built later in 1955. The public sidewalk was not built on the property line. This left at least 8 feet between the back of the sidewalk and the front property line. In general, the purposes of setbacks, but not limited to, are to preserve neighborhood character, provide safe passage for first responders and create separation for privacy. For this property the 15 foot front setback is the west property line. The abutting property to the west is public right-of-way. 2. UApplicant’s statement of justification:U See petitioner’s letter. 3. UStaff Conclusion and Findings:U Under Section 2.10.2(H), staff recommends approval and finds that: • The variance is not detrimental to the public good. • The public sidewalk is further away from the front property line creating an additional setback. • The proposed structure is open on three sides. • The encroachment contains a roof and posts. Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way, when considered in the context of the neighborhood, and will continue to advance the purpose of the Land Use Code as contained in Section 1.2.2 4. URecommendation: Staff recommends approval of APPEAL ZBA190052.   6(&21'    %($5,1*    3($.     $  $  $   Ϯ               $  'EZ>EKd^͗ ͘ ^/'E/EdEd/^dKDd,y/^d/E',KD/E^dz>EK>KZ ͘ KEdZdKZdK&/>sZ/&zy/^d/E'KE/d/KE^WZ/KZdK KE^dZhd/KE ͘ D,E/>E>dZ/>/dD^^,KtE&KZZ&ZEKE>zͲ D,E/>E>dZ/>^,>>^/'EͲh/> ͘ >dZ/>KEdZdKZ/^Z^WKE^/>&KZWW>z/E'>>WW>/> Ed/KE>E>K>K^ ͘ KEhd>dZ/>t><Ͳd,ZKh',t/d,KtEZ^͕h/>ZE >dZ/>KEdZdKZ&KZZKh',Ͳ/E^dZd^ <zEKd^͗ ϭ͘ :Edh/>/E'^Ͳ ^,KtE&KZZ&ZE Ϯ͘ y/^d/E',KDͲ ^,KtE&KZZ&ZE ϯ͘ EtZZ/',Kh^Ͳ ^W>E^E>sd/KE ϰ͘ y/^d/E'Z/stzͲ ^,KtE&KZZ&ZE ϱ͘ Et>>ztz&EdKDd,y/^d/E' ϲ͘ &hdhZWsZ^KZKEZdzKtEZ͕KtEZdKsZ/&z^dz>͕ydEd E^/'Et/d,>E^WZ,/dd ϳ͘ KEZd^>KE'ZKsZWKZKh^&/>>͕^>KWEKZd,E^Khd,dK KsZ,KKZ^Ͳ ^^dZhdhZ>Zt/E'^ ϴ͘ KEZd>E/E'dϲΗKs'Z'&>KKZ ϵ͘ ydZ/KZt>>Ͳ Ϯdžϲ^dhKEϲΗKEZdhZͲ ^^dZhdhZ> Zt/E'^Ͳ WZKs/ZͲϭϵdd/E^h>d/KE͕t/d,^dhK&/E/^,KsZ W>ztKK^,d,/E'dydZ/KZE'zW͘͘&/E/^,d/EdZ/KZ ϭϬ͘ ydZ/KZKsZWKZ,t>>Ͳ Ϯdžϲ^dht>>t/d,^dhK&/E/^,KsZ W>ztKKKd,^/^ ϭϭ͘ ϰϴΗdžϴϰΗZ,KWE/E'EdZd;ϯͿ^/^K&KsZWKZ, ϭϮ͘ ϰϴΗdžϰϴΗDd>'dd>>z^/zKtEZ ϭϯ͘ DKEK>/d,/KEZd^>dWKZ,Ͳ ^^dZhdhZ>Zt/E'^ ϭϰ͘ EdZKKZKZt/EKt/E^W ϭϱ͘ Z/E,/EdKW>EdZ͕KKZ/Ed>Kd/KE/E&/> ϭϲ͘ ^tKZ<^,KtE&KZZ&ZE͕yd>Kd/KEE^dz>zKtEZ EKEdZdKZ ϭϳ͘ tKK&ZD^d/Z^Ͳ ϭϰZ/^Z^dϳ͘ϯΗdžϭϯdZ^dϭϭΗ ϭϴ͘ ϮdžϰWKEzt>>t/d,tKKWdϰϴΗ ϭϵ͘ WZKs/^KhEdd/E^h>d/KEdd,ZKKD ϮϬ͘ tKKdZ>>/^d^Khd,'Z'KKZ Ϯϭ͘ d,ZhͲt>>^hWWZͲ ydE^Khd,^hWWZ&KZZ/E,/EdKW>EdZ >Kt ϮϮ͘ WWZKy/Dd>Kd/KEK&KtE^WKhdͲ KEdZdKZdK&/>sZ/&z Ϯϯ͘ ^dZhdhZ>DͲ ^,KtE&KZZ&ZEͲ ^^dZhdhZ>Zt/E'^ Ϯϰ͘ ^dE/E'^DDd>ZKK&KsZ^EKtE/^,/>͕d,ZhZKK& WEdZd/KE^EͬKZsEd^KEEKZd,KZt^d^>KWKE>z Ϯϱ͘ tKKdZ>>/^KsZt><ͲKhd< Ϯϲ͘ >/EK&t>>>KtͲ ^,KtE&KZZ&ZE Ϯϳ͘ WsZ^z^dDKsZWDZKK&/E' Ϯϴ͘ Ϯdžϲt><ͲKhd<t>>t/d,KEZdWdϰϰΗ Ϯϵ͘ ϲ͘ϱΗ^dhKEd&h>>WZ/DdZK&^KE&>KKZ ϯϬ͘ ϰ͘ϱΗ^dhKEd&h>>WZ/DdZK&&/Z^d&>KKZͲ EKE/E'd /EdZ/KZK&KsZWKZ, ϯϭ͘ Z^^Z,d&/Z^d&>KKZt/EKt,^dKDd,y/^d/E',KD ϯϮ͘ Z,KWE/E'd^Khd,'Z'KKZKE>z ϯϯ͘ WZͲE'/EZdZh^^^Ͳ WZKs/ZͲϯϴdd/E^h>d/KEddd/^W ϯϰ͘ ^dE>KE^/E<^,KtE&KZZ&ZE ϯϱ͘ WZKs/^>dt>>&/E/^,d,/^>Kd/KE ϯϲ͘ dDWZ'>/E' ϯϳ͘ ϱϰΗdžϱϰΗKEZd^dKKWdϵϵΖͲ ϭϭͲϭͬϮΗ ϯϴ͘ ^dZhdhZ>&KhEd/KEͲ ^^dZhdhZ>Zt/E'^ ϯϵ͘ KEZd^>KED/E͘ϰΗWKZKh^&/>> ϰϬ͘ /EdZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲWZKs/Z/'/ /E^h>d/KE&ZKDdKWK&&KKd/E'dKhEZ^/K&^>͕ydEZ/'/ /E^h>d/KE,KZ/KEd>D/E͘ϰϴΗ ϰϭ͘ ydZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲ WZKs/Z/'/ /E^h>d/KEϮϰΗ>Kt'Z͕ydEZ/'//E^h>d/KE/d/KE>ϮϰΗ dϰϱΣ ϰϮ͘ ydZ/KZDd>&>^,/E'KsZZ/'//E^h>d/KEd&h>>WZ/DdZ ϰϯ͘ WK^/d/sZ/E'tz&ZKDh/>/E'D/EϭϬΖͲ ϬΗ ϰϰ͘ yWE^/KE:K/Edd&h>>WZ/DdZK&/EdZ/KZ^> ϰϱ͘ ;ϮͿϮdžϭϬZDDZ^Ͳ ydEϲΖͲ ϬΗD/E/EdZ/KZ ϰϲ͘ Z/E&/>>dtEDDZ^dydZ/KZKE>z ϰϳ͘ WZKs/tdZWZKK&DDZE&>^,/E'ddKWK&tKKDDZ^ ϰϴ͘ WZKs/KWWZ&>^,/E'WddKWK&tKKDDZ^;ϱͿdKd> ϰϵ͘ WZKs/Z>K</E'dtE,KZ/KEd>DDZ^ ϱϬ͘ ;ϯͿϮdžϲZDDZ^Yh>>z^W ϱϭ͘ ;ϭϰͿϮdžϲZDDZ^dϭϲΗK͕͘͘dd,d,ZKh',<^/K& >'ZKZ&KZEKEͲs/^/> ϱϮ͘ ϲdžϲZWK^dd,KZEZK&< ϱϯ͘ ϲdžϴZD͕dd,dKKZEZWK^dt/d,&DKhEdDd> ^dZW^ ϱϰ͘ KEZdt>>W^d/E,^/s ϱϱ͘ WZKs/tdZWZKK&DDZEdWKEzt>>WͲ &h>>WZ/DdZ ϱϲ͘ WZKs/W>ztKK/E&/>>Kd,^/^K&/Ͳ:K/^dt ϱϳ͘ ϭϭͲϳͬϴΗ/Ͳ:K/^dͲ ^^dZhdhZ>͕^dZd>zKhddEdZK&'Z' KKZ ϱϴ͘ ϮdžϲZDDZ>'Z͕dd,d,ZKh',t>>/EdK,Z ƒ          Zs/^/KE^ ^,dKEdEd^ DRAWN CHECKED DATE SHEET NO. Zh^K&KhDEd^͗ d,/^E^/'E/EKZWKZd,ZKE͕^E/E^dZhDEdK&WZK&^^/KE>^Zs/͕/^d,WZKWZdzK& <'ͮ>>E/^EKddKh^&KZEzKd,ZWZK:dt/d,KhdWZ/KZtZ/ddEhd,KZ/d/KEK&<'ͮ>> <'ͮ>> <>ZdͮŽŶƐƵůƚŝŶŐ'ƌŽƵƉ͕>> 2429 Stonecrest Drive Fort Collins, Colorado 80521 970 | 412 | 3049 tomkalert@gmail.com ϭ͘Ϯ ,K,EZZ/',Kh^ ϭϬ͘Ϭϯ͘ϭϵ D <' ^d/KE^Ed/>^ /^^h&KZWZD/dE//E' ϭϰϭϴt^dK<^dZd &KZdK>>/E^͕K>KZKϴϬϱϮϭ EK͘ z ^Z/Wd/KE d ϭ h/1/4" = >1'-/0" E'^d/KEϭ Ϯ h/1/4" = >1'-/0" E'^d/KEϮ ϯ h/1/4" = >1'-/0" E'^d/KEϯ ϰ h/1/4" = >1'-/0" E'^d/KEϰ ϱ dzW/1" = 1'-0" >&KhEd/KE/E^h>d/KEd/> ),567    6(&21'    %($5,1*    3($.     $  $  $ ϭ ϳ ϴ ϵ ϭϬ ϭϭ ϭ Ϯ ϯ                    $ ϲ ϭϯ          'EZ>EKd^͗ ͘ ^/'E/EdEd/^dKDd,y/^d/E',KD/E^dz>EK>KZ ͘ KEdZdKZdK&/>sZ/&zy/^d/E'KE/d/KE^WZ/KZdK KE^dZhd/KE ͘ D,E/>E>dZ/>/dD^^,KtE&KZZ&ZEKE>zͲ D,E/>E>dZ/>^,>>^/'EͲh/> ͘ >dZ/>KEdZdKZ/^Z^WKE^/>&KZWW>z/E'>>WW>/> Ed/KE>E>K>K^ ͘ KEhd>dZ/>t><Ͳd,ZKh',t/d,KtEZ^͕h/>ZE >dZ/>KEdZdKZ&KZZKh',Ͳ/E^dZd^ <zEKd^͗ ϭ͘ :Edh/>/E'^Ͳ ^,KtE&KZZ&ZE Ϯ͘ y/^d/E',KDͲ ^,KtE&KZZ&ZE ϯ͘ EtZZ/',Kh^Ͳ ^W>E^E>sd/KE ϰ͘ y/^d/E'Z/stzͲ ^,KtE&KZZ&ZE ϱ͘ Et>>ztz&EdKDd,y/^d/E' ϲ͘ &hdhZWsZ^KZKEZdzKtEZ͕KtEZdKsZ/&z^dz>͕ydEd E^/'Et/d,>E^WZ,/dd ϳ͘ KEZd^>KE'ZKsZWKZKh^&/>>͕^>KWEKZd,E^Khd,dK KsZ,KKZ^Ͳ ^^dZhdhZ>Zt/E'^ ϴ͘ KEZd>E/E'dϲΗKs'Z'&>KKZ ϵ͘ ydZ/KZt>>Ͳ Ϯdžϲ^dhKEϲΗKEZdhZͲ ^^dZhdhZ> Zt/E'^Ͳ WZKs/ZͲϭϵdd/E^h>d/KE͕t/d,^dhK&/E/^,KsZ W>ztKK^,d,/E'dydZ/KZE'zW͘͘&/E/^,d/EdZ/KZ ϭϬ͘ ydZ/KZKsZWKZ,t>>Ͳ Ϯdžϲ^dht>>t/d,^dhK&/E/^,KsZ W>ztKKKd,^/^ ϭϭ͘ ϰϴΗdžϴϰΗZ,KWE/E'EdZd;ϯͿ^/^K&KsZWKZ, ϭϮ͘ ϰϴΗdžϰϴΗDd>'dd>>z^/zKtEZ ϭϯ͘ DKEK>/d,/KEZd^>dWKZ,Ͳ ^^dZhdhZ>Zt/E'^ ϭϰ͘ EdZKKZKZt/EKt/E^W ϭϱ͘ Z/E,/EdKW>EdZ͕KKZ/Ed>Kd/KE/E&/> ϭϲ͘ ^tKZ<^,KtE&KZZ&ZE͕yd>Kd/KEE^dz>zKtEZ EKEdZdKZ ϭϳ͘ tKK&ZD^d/Z^Ͳ ϭϰZ/^Z^dϳ͘ϯΗdžϭϯdZ^dϭϭΗ ϭϴ͘ ϮdžϰWKEzt>>t/d,tKKWdϰϴΗ ϭϵ͘ WZKs/^KhEdd/E^h>d/KEdd,ZKKD ϮϬ͘ tKKdZ>>/^d^Khd,'Z'KKZ Ϯϭ͘ d,ZhͲt>>^hWWZͲ ydE^Khd,^hWWZ&KZZ/E,/EdKW>EdZ >Kt ϮϮ͘ WWZKy/Dd>Kd/KEK&KtE^WKhdͲ KEdZdKZdK&/>sZ/&z Ϯϯ͘ ^dZhdhZ>DͲ ^,KtE&KZZ&ZEͲ ^^dZhdhZ>Zt/E'^ Ϯϰ͘ ^dE/E'^DDd>ZKK&KsZ^EKtE/^,/>͕d,ZhZKK& WEdZd/KE^EͬKZsEd^KEEKZd,KZt^d^>KWKE>z Ϯϱ͘ tKKdZ>>/^KsZt><ͲKhd< Ϯϲ͘ >/EK&t>>>KtͲ ^,KtE&KZZ&ZE Ϯϳ͘ WsZ^z^dDKsZWDZKK&/E' Ϯϴ͘ Ϯdžϲt><ͲKhd<t>>t/d,KEZdWdϰϰΗ Ϯϵ͘ ϲ͘ϱΗ^dhKEd&h>>WZ/DdZK&^KE&>KKZ ϯϬ͘ ϰ͘ϱΗ^dhKEd&h>>WZ/DdZK&&/Z^d&>KKZͲ EKE/E'd /EdZ/KZK&KsZWKZ, ϯϭ͘ Z^^Z,d&/Z^d&>KKZt/EKt,^dKDd,y/^d/E',KD ϯϮ͘ Z,KWE/E'd^Khd,'Z'KKZKE>z ϯϯ͘ WZͲE'/EZdZh^^^Ͳ WZKs/ZͲϯϴdd/E^h>d/KEddd/^W ϯϰ͘ ^dE>KE^/E<^,KtE&KZZ&ZE ϯϱ͘ WZKs/^>dt>>&/E/^,d,/^>Kd/KE ϯϲ͘ dDWZ'>/E' ϯϳ͘ ϱϰΗdžϱϰΗKEZd^dKKWdϵϵΖͲ ϭϭͲϭͬϮΗ ϯϴ͘ ^dZhdhZ>&KhEd/KEͲ ^^dZhdhZ>Zt/E'^ ϯϵ͘ KEZd^>KED/E͘ϰΗWKZKh^&/>> ϰϬ͘ /EdZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲWZKs/Z/'/ /E^h>d/KE&ZKDdKWK&&KKd/E'dKhEZ^/K&^>͕ydEZ/'/ /E^h>d/KE,KZ/KEd>D/E͘ϰϴΗ ϰϭ͘ ydZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲ WZKs/Z/'/ /E^h>d/KEϮϰΗ>Kt'Z͕ydEZ/'//E^h>d/KE/d/KE>ϮϰΗ dϰϱΣ ϰϮ͘ ydZ/KZDd>&>^,/E'KsZZ/'//E^h>d/KEd&h>>WZ/DdZ ϰϯ͘ WK^/d/sZ/E'tz&ZKDh/>/E'D/EϭϬΖͲ ϬΗ ϰϰ͘ yWE^/KE:K/Edd&h>>WZ/DdZK&/EdZ/KZ^> ϰϱ͘ ;ϮͿϮdžϭϬZDDZ^Ͳ ydEϲΖͲ ϬΗD/E/EdZ/KZ ϰϲ͘ Z/E&/>>dtEDDZ^dydZ/KZKE>z ϰϳ͘ WZKs/tdZWZKK&DDZE&>^,/E'ddKWK&tKKDDZ^ ϰϴ͘ WZKs/KWWZ&>^,/E'WddKWK&tKKDDZ^;ϱͿdKd> ϰϵ͘ WZKs/Z>K</E'dtE,KZ/KEd>DDZ^ ϱϬ͘ ;ϯͿϮdžϲZDDZ^Yh>>z^W ϱϭ͘ ;ϭϰͿϮdžϲZDDZ^dϭϲΗK͕͘͘dd,d,ZKh',<^/K& >'ZKZ&KZEKEͲs/^/> ϱϮ͘ ϲdžϲZWK^dd,KZEZK&< ϱϯ͘ ϲdžϴZD͕dd,dKKZEZWK^dt/d,&DKhEdDd> ^dZW^ ϱϰ͘ KEZdt>>W^d/E,^/s ϱϱ͘ WZKs/tdZWZKK&DDZEdWKEzt>>WͲ &h>>WZ/DdZ ϱϲ͘ WZKs/W>ztKK/E&/>>Kd,^/^K&/Ͳ:K/^dt ϱϳ͘ ϭϭͲϳͬϴΗ/Ͳ:K/^dͲ ^^dZhdhZ>͕^dZd>zKhddEdZK&'Z' KKZ ϱϴ͘ ϮdžϲZDDZ>'Z͕dd,d,ZKh',t>>/EdK,Z Zs/^/KE^ ^,dKEdEd^ DRAWN CHECKED DATE SHEET NO. Zh^K&KhDEd^͗ d,/^E^/'E/EKZWKZd,ZKE͕^E/E^dZhDEdK&WZK&^^/KE>^Zs/͕/^d,WZKWZdzK& <'ͮ>>E/^EKddKh^&KZEzKd,ZWZK:dt/d,KhdWZ/KZtZ/ddEhd,KZ/d/KEK&<'ͮ>> <'ͮ>> <>ZdͮŽŶƐƵůƚŝŶŐ'ƌŽƵƉ͕>> 2429 Stonecrest Drive Fort Collins, Colorado 80521 970 | 412 | 3049 tomkalert@gmail.com ϭ͘ϭ ,K,EZZ/',Kh^ ϭϬ͘Ϭϯ͘ϭϵ D <' >sd/KEEWZ^Wd/s s/t^ /^^h&KZWZD/dE//E' ϭϰϭϴt^dK<^dZd &KZdK>>/E^͕K>KZKϴϬϱϮϭ EK͘ z ^Z/Wd/KE d Ϯ ^1/4" = d>1'-0" sd/KE ϭ EKZd,1/4" = 1'-0" >sd/KE ϯ ^1/Khd,4" = 1'-0" >sd/KE ϰ t^1/4" = 1'-d>0" sd/KE ϴ EKZd,^ds/t ϳ EKZd,t^ds/t ϲ ^Khd,t^ds/t ϱ ^Khd,^ds/t      $  $  $  $ ϯ ϭ ϱ Ϯ ϰ ϲ               ϭ Ϯ       ϯ ϰ                                                                          $  $  $  $ ϳ ϴ ϱ ϭϮ ϲ ϭϯ ϳ ϴ '1         ϵ ϭϬ ϭϭ (4 (4              'EZ>EKd^͗ ͘ ^/'E/EdEd/^dKDd,y/^d/E',KD/E^dz>EK>KZ ͘ KEdZdKZdK&/>sZ/&zy/^d/E'KE/d/KE^WZ/KZdK KE^dZhd/KE ͘ D,E/>E>dZ/>/dD^^,KtE&KZZ&ZEKE>zͲ D,E/>E>dZ/>^,>>^/'EͲh/> ͘ >dZ/>KEdZdKZ/^Z^WKE^/>&KZWW>z/E'>>WW>/> Ed/KE>E>K>K^ ͘ KEhd>dZ/>t><Ͳd,ZKh',t/d,KtEZ^͕h/>ZE >dZ/>KEdZdKZ&KZZKh',Ͳ/E^dZd^ <zEKd^͗ ϭ͘ :Edh/>/E'^Ͳ ^,KtE&KZZ&ZE Ϯ͘ y/^d/E',KDͲ ^,KtE&KZZ&ZE ϯ͘ EtZZ/',Kh^Ͳ ^W>E^E>sd/KE ϰ͘ y/^d/E'Z/stzͲ ^,KtE&KZZ&ZE ϱ͘ Et>>ztz&EdKDd,y/^d/E' ϲ͘ &hdhZWsZ^KZKEZdzKtEZ͕KtEZdKsZ/&z^dz>͕ydEd E^/'Et/d,>E^WZ,/dd ϳ͘ KEZd^>KE'ZKsZWKZKh^&/>>͕^>KWEKZd,E^Khd,dK KsZ,KKZ^Ͳ ^^dZhdhZ>Zt/E'^ ϴ͘ KEZd>E/E'dϲΗKs'Z'&>KKZ ϵ͘ ydZ/KZt>>Ͳ Ϯdžϲ^dhKEϲΗKEZdhZͲ ^^dZhdhZ> Zt/E'^Ͳ WZKs/ZͲϭϵdd/E^h>d/KE͕t/d,^dhK&/E/^,KsZ W>ztKK^,d,/E'dydZ/KZE'zW͘͘&/E/^,d/EdZ/KZ ϭϬ͘ ydZ/KZKsZWKZ,t>>Ͳ Ϯdžϲ^dht>>t/d,^dhK&/E/^,KsZ W>ztKKKd,^/^ ϭϭ͘ ϰϴΗdžϴϰΗZ,KWE/E'EdZd;ϯͿ^/^K&KsZWKZ, ϭϮ͘ ϰϴΗdžϰϴΗDd>'dd>>z^/zKtEZ ϭϯ͘ DKEK>/d,/KEZd^>dWKZ,Ͳ ^^dZhdhZ>Zt/E'^ ϭϰ͘ EdZKKZKZt/EKt/E^W ϭϱ͘ Z/E,/EdKW>EdZ͕KKZ/Ed>Kd/KE/E&/> ϭϲ͘ ^tKZ<^,KtE&KZZ&ZE͕yd>Kd/KEE^dz>zKtEZ EKEdZdKZ ϭϳ͘ tKK&ZD^d/Z^Ͳ ϭϰZ/^Z^dϳ͘ϯΗdžϭϯdZ^dϭϭΗ ϭϴ͘ ϮdžϰWKEzt>>t/d,tKKWdϰϴΗ ϭϵ͘ WZKs/^KhEdd/E^h>d/KEdd,ZKKD ϮϬ͘ tKKdZ>>/^d^Khd,'Z'KKZ Ϯϭ͘ d,ZhͲt>>^hWWZͲ ydE^Khd,^hWWZ&KZZ/E,/EdKW>EdZ >Kt ϮϮ͘ WWZKy/Dd>Kd/KEK&KtE^WKhdͲ KEdZdKZdK&/>sZ/&z Ϯϯ͘ ^dZhdhZ>DͲ ^,KtE&KZZ&ZEͲ ^^dZhdhZ>Zt/E'^ Ϯϰ͘ ^dE/E'^DDd>ZKK&KsZ^EKtE/^,/>͕d,ZhZKK& WEdZd/KE^EͬKZsEd^KEEKZd,KZt^d^>KWKE>z Ϯϱ͘ tKKdZ>>/^KsZt><ͲKhd< Ϯϲ͘ >/EK&t>>>KtͲ ^,KtE&KZZ&ZE Ϯϳ͘ WsZ^z^dDKsZWDZKK&/E' Ϯϴ͘ Ϯdžϲt><ͲKhd<t>>t/d,KEZdWdϰϰΗ Ϯϵ͘ ϲ͘ϱΗ^dhKEd&h>>WZ/DdZK&^KE&>KKZ ϯϬ͘ ϰ͘ϱΗ^dhKEd&h>>WZ/DdZK&&/Z^d&>KKZͲ EKE/E'd /EdZ/KZK&KsZWKZ, ϯϭ͘ Z^^Z,d&/Z^d&>KKZt/EKt,^dKDd,y/^d/E',KD ϯϮ͘ Z,KWE/E'd^Khd,'Z'KKZKE>z ϯϯ͘ WZͲE'/EZdZh^^^Ͳ WZKs/ZͲϯϴdd/E^h>d/KEddd/^W ϯϰ͘ ^dE>KE^/E<^,KtE&KZZ&ZE ϯϱ͘ WZKs/^>dt>>&/E/^,d,/^>Kd/KE ϯϲ͘ dDWZ'>/E' ϯϳ͘ ϱϰΗdžϱϰΗKEZd^dKKWdϵϵΖͲ ϭϭͲϭͬϮΗ ϯϴ͘ ^dZhdhZ>&KhEd/KEͲ ^^dZhdhZ>Zt/E'^ ϯϵ͘ KEZd^>KED/E͘ϰΗWKZKh^&/>> ϰϬ͘ /EdZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲWZKs/Z/'/ /E^h>d/KE&ZKDdKWK&&KKd/E'dKhEZ^/K&^>͕ydEZ/'/ /E^h>d/KE,KZ/KEd>D/E͘ϰϴΗ ϰϭ͘ ydZ/KZ&KhEd/KE/E^h>d/KE͗d&h>>WZ/DdZͲ WZKs/Z/'/ /E^h>d/KEϮϰΗ>Kt'Z͕ydEZ/'//E^h>d/KE/d/KE>ϮϰΗ dϰϱΣ ϰϮ͘ ydZ/KZDd>&>^,/E'KsZZ/'//E^h>d/KEd&h>>WZ/DdZ ϰϯ͘ WK^/d/sZ/E'tz&ZKDh/>/E'D/EϭϬΖͲ ϬΗ ϰϰ͘ yWE^/KE:K/Edd&h>>WZ/DdZK&/EdZ/KZ^> ϰϱ͘ ;ϮͿϮdžϭϬZDDZ^Ͳ ydEϲΖͲ ϬΗD/E/EdZ/KZ ϰϲ͘ Z/E&/>>dtEDDZ^dydZ/KZKE>z ϰϳ͘ WZKs/tdZWZKK&DDZE&>^,/E'ddKWK&tKKDDZ^ ϰϴ͘ WZKs/KWWZ&>^,/E'WddKWK&tKKDDZ^;ϱͿdKd> ϰϵ͘ WZKs/Z>K</E'dtE,KZ/KEd>DDZ^ ϱϬ͘ ;ϯͿϮdžϲZDDZ^Yh>>z^W ϱϭ͘ ;ϭϰͿϮdžϲZDDZ^dϭϲΗK͕͘͘dd,d,ZKh',<^/K& >'ZKZ&KZEKEͲs/^/> ϱϮ͘ ϲdžϲZWK^dd,KZEZK&< ϱϯ͘ ϲdžϴZD͕dd,dKKZEZWK^dt/d,&DKhEdDd> ^dZW^ ϱϰ͘ KEZdt>>W^d/E,^/s ϱϱ͘ WZKs/tdZWZKK&DDZEdWKEzt>>WͲ &h>>WZ/DdZ ϱϲ͘ WZKs/W>ztKK/E&/>>Kd,^/^K&/Ͳ:K/^dt ϱϳ͘ ϭϭͲϳͬϴΗ/Ͳ:K/^dͲ ^^dZhdhZ>͕^dZd>zKhddEdZK&'Z' KKZ ϱϴ͘ ϮdžϲZDDZ>'Z͕dd,d,ZKh',t>>/EdK,Z Zs/^/KE^ ^,dKEdEd^ DRAWN CHECKED DATE SHEET NO. Zh^K&KhDEd^͗ d,/^E^/'E/EKZWKZd,ZKE͕^E/E^dZhDEdK&WZK&^^/KE>^Zs/͕/^d,WZKWZdzK& <'ͮ>>E/^EKddKh^&KZEzKd,ZWZK:dt/d,KhdWZ/KZtZ/ddEhd,KZ/d/KEK&<'ͮ>> <'ͮ>> <>ZdͮŽŶƐƵůƚŝŶŐ'ƌŽƵƉ͕>> 2429 Stonecrest Drive Fort Collins, Colorado 80521 970 | 412 | 3049 tomkalert@gmail.com ϭ͘Ϭ ,K,EZZ/',Kh^ ϭϬ͘Ϭϯ͘ϭϵ D <' ^/dW>E͕&>KKZW>E^E ZKK&W>E /^^h&KZWZD/dE//E' ϭϰϭϴt^dK<^dZd &KZdK>>/E^͕K>KZKϴϬϱϮϭ EK͘ z ^Z/Wd/KE d ϭ ^1" /= dW>20'-0" E E Ϯ &1//4" Z^= 1'-d&0" >KKZW>E ϰ ^3//16" dW>= 1'-0" E ϯ ^1/KE&4" = 1'-0" >KKZW>E E E E 71 LF ~ 6" PVC 100 LF ~ 6" PVC 90° BEND W/ THRUST BLOCK 30 LF ~ 6" PVC DR18 6" SEWER SERVICE 6" SEWER SERVICE 115 LF ~ 6" PVC BIKE RACK (4) 15' U.E. 15' U.E. EXIST. 5' PERMANENT UTILITY ESMT. REC. NO. 20120033214 20' EMERGENCY ACCESS ESMT. 6" GV 5 LF~6" DIP 8' 3' RELOCATED PRIVATE FIRE HYDRANT EX. STORM INLET TO BE REPLACED WITH 4' Ø MANHOLE INV. OUT SW (12") = 5036.89 RELOCATE EX. "BUS STOP" SIGN EX. STORM MANHOLE INV. IN NE (12") = 5035.96 INV. IN NW (6") = 5037.3± INV. OUT SW = 5032.51 EX. SAN. MANHOLE INV. OUT N = 5031.41 EX. SAN. MANHOLE INV. IN S = 5031.18 INV. IN E = 5031.20 INV. OUT N = 5031.03 EX. SAN. MANHOLE INV. IN S = 5031.00 INV. OUT NW = 5030.90 6" SERVICE INV. = 5031.27± VEHICLE STORAGE CUSTOMER EMPLOYEE EMPLOYEE VEHICLE DISPLAY CUSTOMER 4"Ø X 30" H, PIPE BOLLARDS, FILL WITH CONC. CAP AND PAINT, TYP. INSTALL @ 6' 0.C. 4" PVC STORM DRAIN CLEANOUT 4" PVC STORM DRAIN CLEANOUT 2' WIDE CURB-CUT 2' WIDE CURB-CUT 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 4" PVC STORM DRAIN CLEANOUT 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE 20' EMERGENCY ACCESS ESMT. 20' EMERGENCY ACCESS ESMT. 15' DRAINAGE 15' DRAINAGE ESMT. ESMT. 15' DRAINAGE ESMT. 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE CONNECT TO EXIST. 8" WATERLINE WITH WET TAP 4" PVC PERFORATED UNDERDRAIN @ 0.25% SLOPE N 1434390.80 E 3116578.59 N 1434389.41 E 3117002.13 N 1433912.65 E 3116980.38 N 1433909.92 E 3116607.92 N 1434133.98 E 3116612.20 N 1434133.98 E 3116607.20 N 1434215.26 E 3116608.75 N 1434215.35 E 3116603.75 6" CLEAN-OUT N 1434336.00 E 3116767.37 6" CLEAN-OUT N 1434336.00 E 3116838.16 6" CLEAN-OUT N 1434336.00 E 3116938.16 10' (ASPHALT PARKING LOT) 20' W.L. ESMT. 15' U.E. 100' (ASPHALT PARKING LOT) (ASPHALT PARKING LOT) EXIST. GRAVEL DRIVEWAY / PARKING TO REMAIN LOT 2 EXIST. BLDG. TO REMAIN EXIST. BLDG. TO REMAIN EXIST. WALL EXIST. LOADING DOCK EXIST. FENCE EXIST. RAILROAD TRACKS EXIST. CONC. EXIST. GATE. EXIST. CONC. CURB CUT EXIST. CONC. WALK NEW MERCER DITCH CO. LARKBOROUGH SUBDIVISION TRACT G LOT 1 15' U.E. EXIST. WALK EXIST. FIRE HYDRANT LINE TO BE REMOVED TO PROPOSED BEND. Feet 0 30 60 PROPERTY LINE LOT / TRACT LINE LEGEND: S S W W EXISTING SANITARY LINE W/ MH EXISTING STORM LINE W/ MH EXISTING WATER LINE EXISTING STORM AREA INLET EXISTING FIRE HYDRANT EXISTING WATER VALVE EXISTING STORM TYPE 'R' INLET RIGHT-OF-WAY E E EXISTING ELECTRIC LINE G G EXISTING GAS LINE X X EXISTING FENCE LINE 5530 PROPOSED CONTOUR EXISTING CONTOUR S S PROPOSED SANITARY SEWER W/ MH PROPOSED STREET SIGN PROPOSED STORM SEWER W/ MH W W PROPOSED WATER LINE PROPOSED FIRE HYDRANT CTV EXISTING CATV LINE CENTERLINE EXISTING CONCRETE PROPOSED EASEMENT LINE EXISTING EASEMENT LINE PROPOSED WATER VALVE PROPOSED WATER FITTINGS 4 5 PROPOSED TYPE 'R' INLET EXISTING RIGHT-OF-WAY PROPOSED STREET LIGHT D S COM COM EXISTING COMMUNICATION LINE PROPOSED LANDSCAPE PROPOSED ASPHALT PROPOSED CONCRETE U.E. UTILITY EASEMENT ESMT. EASEMENT R.O.W. RIGHT-OF-WAY PROPOSED RED LANDSCAPE EXISTING RED CONCRETE SIDEWALK REPAIR NOTE: ANY DAMAGED CURB, GUTTER AND SIDEWALK EXISTING PRIOR TO CONSTRUCTION, AS WELL AS STREETS, SIDEWALKS, CURBS AND GUTTERS, DESTROYED, DAMAGED OR REMOVED DUE TO CONSTRUCTION OF THIS PROJECT, SHALL BE REPLACED OR RESTORED TO CITY OF FORT COLLINS STANDARDS AT THE DEVELOPER'S EXPENSE PRIOR TO THE ACCEPTANCE OF COMPLETED IMPROVEMENTS AND/OR PRIOR TO THE ISSUANCE OF THE FIRST CERTIFICATE OF OCCUPANCY. BENCHMARK: PROJECT DATUM: NAVD88 BENCHMARK #15-94, AN ALLOY CAP LOCATED ON THE RIM OF AN ELECTRIC MANHOLE ON THE NORTH SIDE OF HARMONY ROAD, APPROXIMATELY 50' EAST OF THE SOUTH 1/4 CORNER OF SECTION 35. ELEVATION = 5054.79 BENCHMARK #48-01, APPROXIMATELY 1/2 SOUTH OF HORSETOOTH ROAD, WEST OF COLLEGE AVENUE AT THE ENTRANCE OF BARNES AND NOBLE BOOKSTORE, IN THE NORTHEAST CORNER OF THEIR PARKING LOT, ON A CONCRETE CURB. ELEVATION = 5036.76 PLEASE NOTE: THIS PLAN SET IS USING NAVD88 FOR A VERTICAL DATUM. SURROUNDING DEVELOPMENTS HAVE USED NGVD29 UNADJUSTED FOR THEIR VERTICAL DATUMS. IF NGVD29 UNADJUSTED DATUM IS REQUIRED FOR ANY PURPOSE, THE FOLLOWING EQUATION SHOULD BE USED: NGVD29 UNADJUSTED = NAVD88 - 3.19' STREET CUT NOTE: LIMITS OF STREET CUT ARE APPROXIMATE. FINAL LIMITS ARE TO BE DETERMINED IN THE FIELD BY THE CITY ENGINEERING INSPECTOR. ALL REPAIRS TO BE IN ACCORDANCE WITH CITY STREET REPAIR STANDARDS. DATE SHEETS SHEET JOB NO. DSG CHK # DATE DRN REVISION DESCRIPTION ACTION CIVIL ENGINEERING 11600 WHOOPING CRANE DRIVE PARKER, CO 80134 720.260.0433 tdenning@actioncivileng.com 20 SCALE Know what's below. Call before you dig. R CITY OF FORT COLLINS, COLORADO UTILITY PLAN APPROVAL APPROVED: ____________________________________ _____________ CITY ENGINEER DATE CHECKED BY: __________________________________ ______________ WATER & WASTE WATER UTILITY DATE CHECKED BY: __________________________________ ______________ STORMWATER UTILITY DATE CHECKED BY: __________________________________ _____________ PARKS & RECREATION DATE CHECKED BY: __________________________________ _____________ TRAFFIC ENGINEER DATE CHECKED BY: __________________________________ _____________ ENVIRONMENTAL PLANNER DATE FORT COLLINS JEEP OVERALL UTILITY PLAN TWD 4/27/2018 --- TWD 16-018 C-7 NOTE: RUN NEW COMMUNICATIONS WIRE TO BUILDING PROPOSED SIGN LOCATION ORIGINAL PERMITED LOCATION Property Line Existing Right-of-Way