Loading...
HomeMy WebLinkAbout05/10/2018 - Zoning Board Of Appeals - Summary Agenda - Regular MeetingHeidi Shuff, Chair Ralph Shields, Vice Chair Daphne Bear Bob Long Cody Snowdon Butch Stockover Karen Szelei-Jackson Council Liaison: Ken Summers Staff Liaison: Noah Beals LOCATION: City Council Chambers 300 LaPorte Avenue Fort Collins, CO 80521 The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224-6001) for assistance. REGULAR MEETING MAY 10, 2018 8:30 AM • CALL TO ORDER and ROLL CALL • CITIZEN PARTICIPATION (Items Not on the Agenda) • APPROVAL OF MINUTES FROM PREVIOUS MEETING • APPEALS FOR VARIANCE TO THE LAND USE CODE 1. APPEAL ZBA180012 Address: 101 E. Stuart Street Petitioner: Malvin Lee, Mr. Lee’s Barber Shop Owners: 105 E. Stuart LLC Zoning District: C-G Code Section: 3.8.7.1(D)(3) and 3.8.7.1(I) Project Description: This is a variance request is to increase the sign allowance for the property. The total allowable sign area is 80 square feet; the request is for an additional 130.35 square feet. The request includes an increase the sign height to 7.5 feet; the maximum height allowed is 7 feet. 2. APPEAL ZBA180014 Address: 312 Wayne Street Petitioner: Al Kulenski Building Owner: Susan Vaughan and Victor Lomax Zoning District: N-C-L Code Section: 4.7(E)(4) Project Description: This is a request to construct a 14 feet x 28 feet carport on the north side of the lot encroaching 4 feet-3 inches into the 5 feet side yard setback. ZONING BOARD OF APPEALS AGENDA Zoning Board of Appeals Page 2 May 10, 2018 3. APPEAL ZBA180015 Address: 1027 Fossil Creek Drive Petitioner: City of Fort Collins Park Planning and Development Department Owners: Lixin Lu and Zhiming Liu Zoning District: U-E Code Section: 3.8.11(C) Project Description: This request is to construct a 5-foot tall, green-dowel, 3-rail western fence to replace the existing fence on the west lot line along the Fossil Creek Trail (which will be constructed in the summer of 2018). The maximum height for a fence in this area is 4 feet. 4. APPEAL ZBA180016 Address: 520 E. Laurel Street Petitioner/Owner: Sharon Kay Wilson Zoning District: N-C-M Code Section: 4.8(E)(3) and 4.8(E)(4) Project Description: This request is to construct 2 buildings on the rear of the lot. Building "A" (12' x 16') would encroach 13 feet into the required 15 feet rear setback. Building "B" (14’ x 16') would encroach 13 feet into the required 15 feet rear setback and 3 feet into the required 5 feet east side setback. • OTHER BUSINESS • ADJOURNMENT Wednesday, February 21, 2018 To whom it may concern: The purpose of this letter is to gain approval for my current signage on the building I am renting. Located at 101 E. Stuart St, Fort Collins, CO, 80525. My name is Malvin Lee, the owner/operator of Mr. Lee’s Barbershop. While I now understand that I should have gotten permission from the city before applying such signage. My goal is to gain approval and continue on operating with the current artwork on said building. The artwork says, “Mr. Lee’s Barbershop”, with a barber pole. In no way is the art disrespectful or causing any harm to anyone. As a matter of fact, my business has grown from such. At this point my clients recognize and find my location because of the sign. What I would like to point out is that, I am providing a service that the community needs. There is absolutely no place in the city that everyone is welcome. Any race, creed or gender can come to my business and be treated fairly. Not to mention get services other places turn them away for. I have been a part of the Fort Collins community for 9 years now. Firstly, inside a place where I was limited in growth as well as expression of my culture and career. Now that I have been given the opportunity to grow and provide even more service to the community. My goal is to raise awareness of the barber culture and make anyone feel welcome to visit my Barbershop. Malvin Lee Page 1 of 1 Park Planning & Development Department 215 N Mason St PO Box 580 Fort Collins, CO 80522 970-416-2192 fcgov.com/parkplanning Memorandum To: Zoning Board of Appeals Date: April 10, 2018; for May 5, 2018 Hearing RE: Application Request for Variance from Land Use Code Sec 3.8.11 to allow construction of a 5’ maximum height, green dowel, 3‐rail western fence to replace existing fence in current location on westerly lot line. By: Greg Oakes, Park Planning & Development Department On Behalf of: Lixin Lu and Zhiming Liu; 1027 Fossil Creek Drive, Fort Collins CO 80526 Reasoning & Justification: The City is currently constructing the Long View Trail – Fossil Creek Dr. to 57th St. in Loveland which will be completed by September 2018. The 10’ wide paved trail will be located partially in the Right‐of‐Way (ROW) on the east side of Shields St. until entering City of Fort Collins (COFC) Natural Areas Property. The Lu’s property is located in a UE zoning district, and was annexed in 2006 as part of the Southwest Enclave Annex Phase Three. All of the properties adjacent to the trail on Shields St. are large‐lot rural estate lots with livestock facilities and use. Due to limited ROW in this area the paved trail will be offset from the north property lines approximately 10 feet. Hardship: The Long View Trail is expected to increase bicycle and pedestrian traffic significantly (potentially 200+ users/day) adjacent to the westerly property line. A 5’ tall fence is requested to deter livestock and trail user conflicts. The 5’ height would prevent large livestock, such as horses or goats, from reaching trail users. It would also limit landowner’s liability from trespass by trail users and potentially dangerous interactions between livestock and trail users. Nominal & Inconsequential: The westerly side of Shields St. ROW is lined with existing livestock fencing on each property between Fossil Creek Drive and COFC Natural Areas Property. The proposed 3‐rail western fence will replace existing 4’ high, t‐post, woven wire and barbed wire fence on this property and will maintain the character of the existing neighborhood. Equal to or Better Than: The proposed fence will contain livestock and will present a more secure barrier between livestock and trail users. Fossil Creek Drive Lu Pasture View Looking Northeast From Shields St. May 10, 2018 1027 Fossil Creek Drive Planning & Zoning Board of Appeals Variance Request Existing 4’ Livestock Fence 4 Strand Wire Fence w/ T-Posts (Red Dashed Line) Long View Trail May 10, 2018 1027 Fossil Creek Drive Planning & Zoning Board of Appeals Variance Request Lu Pasture Shields Street Lu Pasture Existing 4’ Livestock Fence 4 Strand Wire Fence w/ T-Posts (Red Dashed Line) Existing 4’ Livestock Fence 4 Strand Wire Fence w/ T-Posts (Red Dashed Line) Long View Trail Long View Trail View Looking South From Trail From: Sharon K Wilson skw@centurylink.net Subject: Date: April 10, 2018 at 2:36 PM To: 5.0 PORTLAND SERIES PRODUCT GUIDE 16’ FRONT/ BACK SIZES (D) = SHED DEPTH | (W) = SHED WIDTH | (mH) = MAX ROOF HEIGHT | (H) = SIDE WALL HEIGHT 12 7 5’-0 1/2” BOT 18x36 WINDOW 3’-6 1/2” BOT 36x36 WINDOW 1’-6 1/2” BOT 60x30 WINDOW 6’-6 1/2” TOP WINDOW 0.2-Sig-Product-Guide-Cutaway.jpg 2,316x3,015 pixels 0 SH ED '" 3--- 14-....... 5-- ----1=::::;;;i�2 8--------------�-'--e 15------+...f WOOD FRAMED FLOOR OR CONCRETE SLAB STANDARD FEATURES: 1) GALVALUME OR PAINTED CORRUGATED METAL ROOF 2) PLYWOOD ROOF SHEATHING 3) 2x RAFTERS AND BLOCKING 4) CUSTOM MANUFACTURED ALUMINUM FLASHING AND TRIM 5) SIMPSON STRONG-TIE® TIE-DOWNS AT ALL RAFTER CONNECTIONS 6) ZIP SYSTEM® WALL SHEATHING WITH INTERGRATED WATER-RESISTIVE BARRIER 7) FIBER CEMENT SIDING 8) FIR AND ENGINEERED WOOD WALL FRAMING 9) ROOFING FELT (BY INSTALLER OR CUSTOMER) OPTIONAL ADD-ONS: 10) ENERGY EFFICIENT LOW-E OPERABLE WINDOWS 11) PRESSURE TREATED WOOD FRAMED FLOOR ON PIERS (AVAILABLE ON SELECT MODELS) 3/23/18, 12:41 PM SIGNATURE SERIES PRODUCT GUIDE 4 :;....-e:aa1111111....,.---�12 LIFESTYLE PACKAGE: 11) SEAMLESS DRYWALL INTERIOR 12) RECYCLED DENIM ROOF INSULATION - R-21 (2x6 RAFTERS) - R-30 (2x8 AND 2x10 RAFTERS) 13) RECYCLED DENIM WALL INSULATION - R-13 14) 3" INTERIOR RECESSED LIGHT FIXTURES - LED (600 LUMENS) 15) ELECTRICAL PACKAGE - EXTERIOR MOUNTED JUNCTION BOX WITH 15 AND 20 AMP BREAKERS 4 - DUPLEX WALL OUTLET, DUPLEX GFCI OUTLET AND EXTERIOR DUPLEX OUTLET - LIGHT SWITCHES - EXTERIOR LIGHT FIXTURE(S) 16) FINISHED FLOORING OPTIONS - ENGINEERED WOOD - CORK 0.2 https:// qi krg2ve4526wc3c3ntlhj 1 e-wpengi ne. netdna-ssl. com/ ... contenVu ploads/2 01 5/02/0 .2-Sig-Prod uct-Guide-Cutaway. j pg Page 1 of 4 MILGARD FIXED WINDOW SIZE VARIES, SEE PLANS 1/2" ZIP-SYSTEM™ WALL SHEATHING WITH IMPREGNATED MOISTURE BARRIER ICC ESR-1474 3/4" PLYWOOD ROOF SHEATHING 2x ROOF RAFTER, SEE 1/S102 5/16" HARDIPANEL FIBER CEMENT EXTERIOR SIDING ICC ESR-2290 1/4" HARDIESOFFIT FIBER CEMENT SOFFIT ICC ESR-2273 26 GA ALUMINUM FLASHING GALVALUME 26 GA COR MTL ROOF ICC ESR-2385 26 GA ALUMINUM FLASHING CONCRETE FOUNDATION, SEE 1/S-100 ROOF UNDERLAYMENT ICC ESR-1306 P.T. STRANDGUARD (ZB TREATED) TIMBERSTRAND LSL SILL PLATE ICC ESR#1387, SECTION 5.5 SEE 1/A-300 FOR MORE INFORMATION R-21 RECYCLED DENIM INSULATION 1/2" GYPSUM BOARD AIR-IMPERMIABLE CLOSED CELL SPRAY FOAM TO FILL ENTIRE CAVITY 1/2" GYPSUM BOARD 5/8" TYPE 'X' GYPSUM BOARD 5/8" TYPE 'X' GYPSUM BOARD STUDIOSHED | 720.336.2071 | LOUISVILLE SUMMIT SERIES1-HOUR FIRE RATING DETAIL CO