HomeMy WebLinkAbout03/14/2018 - Landmark Preservation Commission - Agenda - Work SessionMeg Dunn, Chair Conference Room A
Alexandra Wallace, Vice Chair 281 N. College Ave.
Michael Bello Fort Collins, Colorado
Katie Dorn
Bud Frick After 5:00 p.m., please use the
North College entrance and ring
the doorbell for assistance.
Kristin Gensmer
Per Hogestad
Kevin Murray
Mollie Simpson
Fort Collins is a Certified Local Government (CLG) authorized by the National Park Service and History Colorado based on its
compliance with federal and state historic preservation standards. CLG standing requires Fort Collins to maintain a Landmark
Preservation Commission composed of members of which a minimum of 40% meet federal standards for professional experience
from preservation-related disciplines, including, but not limited to, historic architecture, architectural history, archaeology, and urban
planning. For more information, see Article III, Division 19 of the Fort Collins Municipal Code.
The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make
special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224-6001) for assistance.
An audio recording of the meeting is available upon request.
Work Session
March 14, 2018
5:30 PM
• CALL TO ORDER
• ROLL CALL
• REVIEW OF ITEMS FOR CONSIDERATION AT THE NEXT REGULAR MEETING TO BE HELD
ON WEDNESDAY, MARCH 21, 2017 AT 5:30 P.M. IN CITY COUNCIL CHAMBERS
DISCUSSION
1. 225 MAPLE STREET - CONCEPTUAL DESIGN REVIEW
2. 225 SOUTH LOOMIS AVENUE DETERMINATION OF ELIGIBILITY APPEAL
3. 221 EAST MOUNTAIN - CONCEPTUAL DEVELOPMENT REVIEW
4. OASIS ON OLIVE - DEVELOPMENT REVIEW
• I. POLICY AND LEGISLATION
1. Discussion of the Downtown Plan
2. Overview of Phase 2 Sign Code Update
• II. BOARD TOPICS
1. LPC Work Plan - Progress and Priorities
• OTHER BUSINESS
• ADJOURNMENT
Landmark
Preservation
Commission
Roll Call – Work Session
Landmark Preservation Commission
Date: 3/14/18
Bello
Dorn
Dunn excused
Frick
Gensmer excused
Hogestad
Murray
Simpson
Wallace
DATE:
STAFF:
March 14, 2018
Karen McWilliams, Historic Preservation Planner
WORK SESSION ITEM
Landmark Preservation
Commission
SUBJECT FOR DISCUSSION
Discussion of the Downtown Plan
EXECUTIVE SUMMARY
The purpose of this item is to discuss potential changes to the Downtown Plan, based on strategies
recommended in the recently adopted Downtown Plan and Old Town Neighborhoods Plan, and in direction
provided through the Historic Preservation code review project.
GENERAL DIRECTION SOUGHT AND SPECIFIC QUESTIONS TO BE ANSWERED
At this Work Session, the LPC will be discussing potential changes to the Downtown Plan. The project objective is
to provide greater predictability in the Land Use Code regulations by clarifying standards that apply to new infill
and redevelopment projects. The Commission’s comments will be used by staff to help develop tailored solutions
that best meet community needs and support Council’s policies.
BACKGROUND / DISCUSSION
City staff is developing a series of amendments to the Land Use Code to implement policies on three interrelated
Land Use Code amendment projects that together address the compatibility of new construction with our existing
built environment. Those efforts include improved Historic Preservation Adjacency Standards (part of the current
Historic Preservation code review project), amendments to design standards for Downtown, and the NCB
(Neighborhood Conservation Buffer) transition areas at the interface between Downtown the Old Town
Neighborhoods. These strategies were recommended in the recently adopted Downtown Plan and Old Town
Neighborhoods Plan, and in direction provided through the Historic Preservation code review project.
Proposed code changes would provide form- and performance-based metrics that augment existing design
standards. The new standards need to promote compatibility, clarity, and predictability, yet allow for creative
building forms and site design options.
ATTACHMENTS
1. Downtown Plan Presentation (PDF)
1.1
Packet Pg. 2
Code Update Process For:
Downtown
Neighborhood Conservation Buffer (NCB)
1.1.a
Packet Pg. 3
Attachment: Downtown Plan Presentation
The Fort Collins
Old Town
Neighborhoods
Plan
The 2017 Fort Collins
Downtown Plan
1.1.a
Packet Pg. 4
Attachment: Downtown Plan Presentation
Policy UD 3a: Context Sensitive Building Design. Clarify City requirements for the
design character of new buildings to be context sensitive, drawing on existing patterns,
terms of typology, building proportions and massing in the surrounding area.
Action Item:
UD 3a (1): Develop Land Use Code regulations that set specific design metrics on which to base design
compatibility within its context.
Principle UD 3: Promote high-quality building design and materials.
1.1.a
Packet Pg. 5
Attachment: Downtown Plan Presentation
Neighborhood Character
& Compatibility
Land Use
& Transition Areas
NCC-1: Preserve character of the
neighborhoods
NCC-2: Protect historic resources within the
neighborhoods
NCC-3: Support compatible building design
for new construction and remodels
LUT-2: Improve transitions between
neighborhoods/ Downtown/CSU
1.1.a
Packet Pg. 6
Attachment: Downtown Plan Presentation
Code Update Objectives
• Retain and enhance our sense of place
• Strengthen compatibility and transition standards
• Promote individual subdistrict character
• Increase clarity and predictability; Simplify standards when possible
• Strengthen graphic representation
• Strengthen standards geared towards pedestrians
1.1.a
Packet Pg. 7
Attachment: Downtown Plan Presentation
The pedestrian
experience is
paramount
throughout
Downtown
1.1.a
Packet Pg. 8
Attachment: Downtown Plan Presentation
Organizing Structure for
the Downtown (D) Code:
• Character Subdistricts
• Street Character Type
• Building Form
• Site Requirements
1.1.a
Packet Pg. 9
Attachment: Downtown Plan Presentation
Mountain Ave
Laporte Ave
Maple St
Cherry St
Laurel St
Mulberry St
Myrtle St
Riverside Ave
Poudre River
Magnolia St
Mason St
College Ave
Howes St
Meldrum St
Sherwood St
Lemay Ave
Whitcomb St
Olive St
Oak St
Old Town
Square
Canyon Ave
Linden St
Vine Dr
Lincoln Ave
N
CSU
CC
NC�
��L
�
��L
NC�
CC�
�
NCL
NC�
NC�
��L
CC�
CC�
�L
�C
CL
L�N
���
NC�
C�
T
�
��N
NC�
�
�
�
NC�
NC�
1.1.a
Packet Pg. 10
Attachment: Downtown Plan Presentation
Mountain Ave
Laporte Ave
Maple St
Cherry St
Laurel St
Mulberry St
Myrtle St
Riverside Ave
Poudre River
Magnolia St
Mason St
College Ave
Howes St
Meldrum St
Sherwood St
Lemay Ave
Whitcomb St
Olive St
Oak St
Old Town
Square
Canyon Ave
Linden St
Vine Dr
Lincoln Ave
N
CSU
��L
�
��L
NC�
�
NCL
NC�
NC�
��L
�L
�C
L�N
NC�
C�
��N
NC�
�
�
NC�
NC�
�
1.1.a
Packet Pg. 11
Attachment: Downtown Plan Presentation
Campus North Subdistrict
Canyon
Avenue
Subdistrict
Civic Subdistrict
North Mason
Subdistrict
Historic
Core
Subdistrict
River Subdistrict
Innovation Subdistrict
Poudre River Corridor
Entryway Corridor
Subdistrict Regulation Promote Subdistrict Defining Character Traits
1.1.a
Packet Pg. 12
Attachment: Downtown Plan Presentation
N
Jefferson
College
Willow
Linden
Lincoln
R-D-R Standard:
4.17(d)(3)(c) Character and Image. New buildings shall be designed to demonstrate compatibility with the historical
agricultural/industrial characteristics of the District in order to promote visual cohesiveness and emphasize positive
historical attributes. Such characteristics include simple rectilinear building shapes, simple rooflines, juxtaposed
building masses that directly express interior volumes/functions, visible structural components and joinery, details
formed by brickwork, sandstone, sills, lintels, headers and foundations and details formed by joinery of structural
materials.
1.1.a
Packet Pg. 13
Attachment: Downtown Plan Presentation
Street Character Type
Storefront
Mixed Use
Parkway
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 14
Attachment: Downtown Plan Presentation
• 0-5’ Setback
• Ground floor commercial
facing street
• High building detail/
transparency facing street
Street Character Type
Storefront
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 15
Attachment: Downtown Plan Presentation
• 5-10’ Setback
• Setback can be landscaped
or paved
• No ground floor use
requirement
Street Character Type
Mixed Use
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 16
Attachment: Downtown Plan Presentation
• 10’+ Setback
• Landscaped setback
• No ground floor use
requirement
Street Character Type
Parkway
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 17
Attachment: Downtown Plan Presentation
I. Building Requirements per Street Character Type:
The following building criteria are dictated by the site’s Street Character Type(s):
STREET CHARACTER TYPE
Storefront Mixed Use Parkway
Minimum Setback 0’ 5’ 10’
Min. Alley, Sidelot and Rear Lot
Setbacks
0’ Sidelot
5’ Alley
0’ Rear Yard
0’ Sidelot
5’ Alley
5’ Rear Yard
10’ Sidelot
5’ Alley
5’ Rear Yard
Required Street Frontage Build-To
Range (as measured from the setback)
90% at 0 to 5’
Alt. to provide open space...
75% at 5 to 10’
Alt. to provide open space...
50% at 10 to 20’
Alt. to provide open space...
Primary Entrance Location
For parcels with multiple street frontage types, the primary entrance must face a Storefront Street if
present, otherwise a Mixed-Use Street. The primary entrance may face a Parkway Street only when
other street frontage types are not present.
Garage Entry Location & Utility/Service
Locations
Garage entries and utility or services locations shall be located in alleys. If no alley is present, they
may be located on a Parkway Street If a Parkway Street is not present, they may be located on a
Miked-Use Street. Garage entries and utility or service locations are not allowed on Storefront
street frontages without Planning Director approval.
Lower-Story Building Materials
The Lower Stories, defined as the lower portion of the building
until the first upper-story step-back of a minimum of 3 feet, must
be constructed of masonry units (brick, stone, CMU, etc.) or
metal panel units on street facing facades.
Ground-Floor Transparency 60% 40% 25%
Ground Floor Use Requirements
Maximum 25% Street-facing
linear frontage for residential
living space uses
None
II. Site Requirements per Street Frontage Type:
The following streetscaping criteria are dictated by the site’s Street Frontage Type(s):
1.1.a
Packet Pg. 18
Attachment: Downtown Plan Presentation
I. Building Requirements per Street Character Type:
The following building criteria are dictated by the site’s Street Character Type(s):
STREET CHARACTER TYPE
Storefront Mixed Use Parkway
Minimum Setback 0’ 5’ 10’
Min. Alley, Sidelot and Rear Lot
Setbacks
0’ Sidelot
5’ Alley
0’ Rear Yard
0’ Sidelot
5’ Alley
5’ Rear Yard
10’ Sidelot
5’ Alley
5’ Rear Yard
Required Street Frontage Build-To
Range (as measured from the setback)
90% at 0 to 5’
Alt. to provide open space...
75% at 5 to 10’
Alt. to provide open space...
50% at 10 to 20’
Alt. to provide open space...
Primary Entrance Location
For parcels with multiple street frontage types, the primary entrance must face a Storefront Street if
present, otherwise a Mixed-Use Street. The primary entrance may face a Parkway Street only when
other street frontage types are not present.
Garage Entry Location & Utility/Service
Locations
Garage entries and utility or services locations shall be located in alleys. If no alley is present, they
may be located on a Parkway Street If a Parkway Street is not present, they may be located on a
Miked-Use Street. Garage entries and utility or service locations are not allowed on Storefront
street frontages without Planning Director approval.
Lower-Story Building Materials
The Lower Stories, defined as the lower portion of the building
until the first upper-story step-back of a minimum of 3 feet, must
be constructed of masonry units (brick, stone, CMU, etc.) or
metal panel units on street facing facades.
Ground-Floor Transparency 60% 40% 25%
Ground Floor Use Requirements
Maximum 25% Street-facing
linear frontage for residential
living space uses
None
II. Site Requirements per Street Frontage Type:
The following streetscaping criteria are dictated by the site’s Street Frontage Type(s):
1.1.a
Packet Pg. 19
Attachment: Downtown Plan Presentation
Required Build-To Zone
Min. Setback Based on
Street Frontage Type
Building Footprint
Length of Building In
Build-To Zone
Total Block Frontage (Feet)
KEY
Property Line
Build-To Line
Min. Setback
Total Block Frontage (Feet)
Length of Building in Build-To Zone (Feet)
( ) X 100 = Build-To Percentage 1.1.a
Packet Pg. 20
Attachment: Downtown Plan Presentation
I. Building Requirements per Street Character Type:
The following building criteria are dictated by the site’s Street Character Type(s):
STREET CHARACTER TYPE
Storefront Mixed Use Parkway
Minimum Setback 0’ 5’ 10’
Min. Alley, Sidelot and Rear Lot
Setbacks
0’ Sidelot
5’ Alley
0’ Rear Yard
0’ Sidelot
5’ Alley
5’ Rear Yard
10’ Sidelot
5’ Alley
5’ Rear Yard
Required Street Frontage Build-To
Range (as measured from the setback)
90% at 0 to 5’
Alt. to provide open space...
75% at 5 to 10’
Alt. to provide open space...
50% at 10 to 20’
Alt. to provide open space...
Primary Entrance Location
For parcels with multiple street frontage types, the primary entrance must face a Storefront Street if
present, otherwise a Mixed-Use Street. The primary entrance may face a Parkway Street only when
other street frontage types are not present.
Garage Entry Location & Utility/Service
Locations
Garage entries and utility or services locations shall be located in alleys. If no alley is present, they
may be located on a Parkway Street If a Parkway Street is not present, they may be located on a
Miked-Use Street. Garage entries and utility or service locations are not allowed on Storefront
street frontages without Planning Director approval.
Lower-Story Building Materials
The Lower Stories, defined as the lower portion of the building
until the first upper-story step-back of a minimum of 3 feet, must
be constructed of masonry units (brick, stone, CMU, etc.) or
metal panel units on street facing facades.
Ground-Floor Transparency 60% 40% 25%
Ground Floor Use Requirements
Maximum 25% Street-facing
linear frontage for residential
living space uses
None
II. Site Requirements per Street Frontage Type:
The following streetscaping criteria are dictated by the site’s Street Frontage Type(s):
1.1.a
Packet Pg. 21
Attachment: Downtown Plan Presentation
Min. 3' Upper Floor Stepback at
Building Material Change* KEY
Lower-Story Building Material Requirement
*Note other Upper Story Stepbacks may be required
1.1.a
Packet Pg. 22
Attachment: Downtown Plan Presentation
I. Building Requirements per Street Character Type:
The following building criteria are dictated by the site’s Street Character Type(s):
STREET CHARACTER TYPE
Storefront Mixed Use Parkway
Minimum Setback 0’ 5’ 10’
Min. Alley, Sidelot and Rear Lot
Setbacks
0’ Sidelot
5’ Alley
0’ Rear Yard
0’ Sidelot
5’ Alley
5’ Rear Yard
10’ Sidelot
5’ Alley
5’ Rear Yard
Required Street Frontage Build-To
Range (as measured from the setback)
90% at 0 to 5’
Alt. to provide open space...
75% at 5 to 10’
Alt. to provide open space...
50% at 10 to 20’
Alt. to provide open space...
Primary Entrance Location
For parcels with multiple street frontage types, the primary entrance must face a Storefront Street if
present, otherwise a Mixed-Use Street. The primary entrance may face a Parkway Street only when
other street frontage types are not present.
Garage Entry Location & Utility/Service
Locations
Garage entries and utility or services locations shall be located in alleys. If no alley is present, they
may be located on a Parkway Street If a Parkway Street is not present, they may be located on a
Miked-Use Street. Garage entries and utility or service locations are not allowed on Storefront
street frontages without Planning Director approval.
Lower-Story Building Materials
The Lower Stories, defined as the lower portion of the building
until the first upper-story step-back of a minimum of 3 feet, must
be constructed of masonry units (brick, stone, CMU, etc.) or
metal panel units on street facing facades.
Ground-Floor Transparency 60% 40% 25%
Ground Floor Use Requirements
Maximum 25% Street-facing
linear frontage for residential
living space uses
None
II. Site Requirements per Street Frontage Type:
The following streetscaping criteria are dictated by the site’s Street Frontage Type(s):
1.1.a
Packet Pg. 23
Attachment: Downtown Plan Presentation
2'
7' Zone of Transparency (Feet)
Total Street-Facing Frontage (Feet) x Zone of Transparency (Feet)
Total Transparent Window Area Provided in Zone of Transparency (SF)
( ) X 100 = Ground Floor
Transparency
Percentage
Total Street-Facing Frontage (Feet)
Zone of
Transparency
(Feet)
1.1.a
Packet Pg. 24
Attachment: Downtown Plan Presentation
Ground-Floor Transparency
Approximately 60%
Total Street-Facing Frontage
2'
7'
123 N College Ave.
Zone of
Transparency
1.1.a
Packet Pg. 25
Attachment: Downtown Plan Presentation
Ground-Floor Transparency
Approximately 31%
Total Street-Facing Frontage
2'
7'
103 W Mountain Ave.
Zone of
Transparency
1.1.a
Packet Pg. 26
Attachment: Downtown Plan Presentation
Current Max. Height
(Stories)
2.5
3
4
5
6
9
12
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 27
Attachment: Downtown Plan Presentation
Proposed Max. Height
(Stories)
3
4
5
6
12
Considering incentives
to allow an additional
story such as:
• Structured parking
• Public open space/Nature
in the City
• Building mass mitigation
• Green building techniques
• Affordable units
College
Laurel
Lincoln
Vine
Mountain
1.1.a
Packet Pg. 28
Attachment: Downtown Plan Presentation
MAXIMUM HEIGHT ALLOWANCE (per zoning map)
3 Stories 4 Stories 5 Stories 6 Stories 12 Stories
Maximum Floor Plate Sizes None Required
Floor plates above the
6th story shall not
exceed 15,000 SF.
Upper-Story Stepbacks:
5th-Story Stepback None.
Buildings with 5 or more stories must have a 10’ stepback above
the 4th story, measured from the street-facing setback, and must
comply with the Contextual Heights Stepback requirements
(below).
Contextual Heights
Stepback
None.
Where a parcel
with a maximum of
4-stories in height is
located immediately
across the street
from a block with a
3-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 5-stories in
height is located
immediately across
the street from a
block with a 3- or
4-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 6-stories in
height is located
immediately across
the street from a
block with a 3-, 4-
or 5-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
MAXIMUM HEIGHT ALLOWANCE (per zoning map)
3 Stories 4 Stories 5 Stories 6 Stories 12 Stories
Maximum Floor Plate Sizes None Required
Floor plates above the
6th story shall not
exceed 15,000 SF.
Upper-Story Stepbacks:
5th-Story Stepback None.
Buildings with 5 or more stories must have a 10’ stepback above
the 4th story, measured from the street-facing setback, and must
comply with the Contextual Heights Stepback requirements
(below).
Contextual Heights
Stepback
None.
Where a parcel
with a maximum of
4-stories in height is
located immediately
across the street
from a block with a
3-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 5-stories in
height is located
immediately across
the street from a
block with a 3- or
4-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 6-stories in
height is located
immediately across
the street from a
block with a 3-, 4-
or 5-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
5th-Story Stepback
KEY
Property Line
5th-Story Stepback
Min. Setback
1.1.a
Packet Pg. 31
Attachment: Downtown Plan Presentation
MAXIMUM HEIGHT ALLOWANCE (per zoning map)
3 Stories 4 Stories 5 Stories 6 Stories 12 Stories
Maximum Floor Plate Sizes None Required
Floor plates above the
6th story shall not
exceed 15,000 SF.
Upper-Story Stepbacks:
5th-Story Stepback None.
Buildings with 5 or more stories must have a 10’ stepback above
the 4th story, measured from the street-facing setback, and must
comply with the Contextual Heights Stepback requirements
(below).
Contextual Heights
Stepback
None.
Where a parcel
with a maximum of
4-stories in height is
located immediately
across the street
from a block with a
3-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 5-stories in
height is located
immediately across
the street from a
block with a 3- or
4-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 6-stories in
height is located
immediately across
the street from a
block with a 3-, 4-
or 5-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
Contextual Height Stepback
Public Right-of-Way
Allowable Height
(Stories) of Property
Accross Street
Property Line
Property Line
1.1.a
Packet Pg. 33
Attachment: Downtown Plan Presentation
MAXIMUM HEIGHT ALLOWANCE (per zoning map)
3 Stories 4 Stories 5 Stories 6 Stories 12 Stories
Maximum Floor Plate Sizes None Required
Floor plates above the
6th story shall not
exceed 15,000 SF.
Upper-Story Stepbacks:
5th-Story Stepback None.
Buildings with 5 or more stories must have a 10’ stepback above
the 4th story, measured from the street-facing setback, and must
comply with the Contextual Heights Stepback requirements
(below).
Contextual Heights
Stepback
None.
Where a parcel
with a maximum of
4-stories in height is
located immediately
across the street
from a block with a
3-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 5-stories in
height is located
immediately across
the street from a
block with a 3- or
4-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 6-stories in
height is located
immediately across
the street from a
block with a 3-, 4-
or 5-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
Required Facade
Plane Changes
> 130' Structure Length
Max. Lower Story Wall Length
Example shows a 200’ Building
1.1.a
Packet Pg. 35
Attachment: Downtown Plan Presentation
MAXIMUM HEIGHT ALLOWANCE (per zoning map)
3 Stories 4 Stories 5 Stories 6 Stories 12 Stories
Maximum Floor Plate Sizes None Required
Floor plates above the
6th story shall not
exceed 15,000 SF.
Upper-Story Stepbacks:
5th-Story Stepback None.
Buildings with 5 or more stories must have a 10’ stepback above
the 4th story, measured from the street-facing setback, and must
comply with the Contextual Heights Stepback requirements
(below).
Contextual Heights
Stepback
None.
Where a parcel
with a maximum of
4-stories in height is
located immediately
across the street
from a block with a
3-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 5-stories in
height is located
immediately across
the street from a
block with a 3- or
4-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Where a parcel
with a maximum
of 6-stories in
height is located
immediately across
the street from a
block with a 3-, 4-
or 5-story maximum
height allowance,
the building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
Sample Imagery: 1.1.a
Packet Pg. 37
Attachment: Downtown Plan Presentation
College
Laurel
Lincoln
Vine
Mountain
NCB Standards
New standards will
respond to the current
neighborhood code
standards as well as
the new Downtown
standards
1.1.a
Packet Pg. 38
Attachment: Downtown Plan Presentation
Landscape
Setbacks
Ground Floor
Character
Roof
Form
Upper Floor
Stepbacks
Design techniques to
consider for the NCB
transition area
1.1.a
Packet Pg. 39
Attachment: Downtown Plan Presentation
The Downtown
code section will
include additional
historic preservation
considerations specific
to the Downtown
1.1.a
Packet Pg. 40
Attachment: Downtown Plan Presentation
Next Steps
1.1.a
Packet Pg. 41
Attachment: Downtown Plan Presentation
DATE:
STAFF:
March 14, 2018
Maren Bzdek, Historic Preservation Planner
WORK SESSION ITEM
Landmark Preservation
Commission
SUBJECT FOR DISCUSSION
Overview of Phase 2 Sign Code Update
EXECUTIVE SUMMARY
The purpose of this item is to provide the Landmark Preservation Commission with the opportunity to learn about
the proposed Phase 2 sign code changes and provide comments.
GENERAL DIRECTION SOUGHT AND SPECIFIC QUESTIONS TO BE ANSWERED
Noah Beals, Senior City Planner, Zoning, will provide an overview of the proposed Phase 2 comprehensive sign
code changes and ask for feedback on proposed changes that relate to new and historic signs in the Downtown
zoning district. Other changes relate to billboard signs and signs using new technology, such as electronic
messaging centers, interactive window signs, projected light signs.
BACKGROUND / DISCUSSION
Fort Collins has regulated signs since the 1970s, when rapid growth and sign proliferation and growth in
commercial marketing created impacts on the character and identity of Fort Collins. Regulations are meant to
balance business interests with community aesthetics, preserve and enhance property values, provide a level
playing field for commercial and non-commercial speech, and protect public safety. A 2015 U.S. Supreme Court
Case, Reed v. Town of Gilbert, clarified that sign codes must be “content neutral,” meaning that regulations
cannot vary standards such as size, location, and duration based on the message of the sign. Some existing City
codes are based on the type or message of the regulated sign.
The Downtown Plan (2017) calls for preservation of historic character, attractive streets, defined gateways, and
enhanced pedestrian experience and recognizes the contribution of signage to these goals. The Old Town Design
Standards provide additional requirements for signs within the district boundary.
Interim sign code changes were implemented in 2017. The Phase 2 changes will address enhanced legibility,
needs associated with implementation of the Downtown Plan, changes related to new sign technologies, and the
relationship of the standards to City goals.
1.2
Packet Pg. 42
1
SIGN CODE UPDATE
Landmark Preservation Committee Meeting – March 14, 2018
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-1
Process
PRESENTATION
PURPOSES:
Share progress on
Phase 2
(permanent signs)
Receive LPC input
on Historic Sign
re-creation
Receive LPC input
on proposed
Downtown Sign
changes
2
• Public Meetings (2)
• Online Questionnaire (160+ responses)
• Coffee Talks (3)
• Worksessions with boards and commissions
• Draft Code
• Public Meeting
• Public Hearings
• Listening Sessions
• Public Meeting
• Public hearings on content-
neutral regulations
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-2
Why Regulate Signs?
Sign regulations
• Balance business interests and community aesthetics
• Balance the right to expression vs. public safety
• Preserve and enhance property values
Why update the Sign Code now?
• Confirm current sign standards are meeting City’s goals, such as
economic development
• Enhance code legibility
• Implement the recently adopted Downtown Plan
• Explore changes to accommodate new technology
4
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-3
Bottom Line
5
Potential impact to business owners:
• If the sign code is updated, existing signs can remain.
• More sign types could be available: historic signs,
secondary roofs, interactive window signs, horizontal and/or
vertical light projected signs
• Sign allowances could be increased: for taller buildings
• Revised standards: window signs, wall signs
OR
Permanent Sign Code remains the same (no options added).
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-4
Sign Options
6
SIGN TYPE LOCATION WHAT COULD CHANGE?
WHAT WILL NOT
CHANGE?
Wall Signs Downtown Specify lighting method? Revise heights based
on pedestrian environment and height of
building? Flexibility for vertical wall signs?
Other existing standards.
Projecting Signs Downtown
Increase height relative to height of building?
Flexibility for vertical projecting signs?
Other existing standards.
Window Signs Downtown
Increase/decrease coverage allowance? Address
transparent signs?
Other existing standards.
Awning Signs Downtown
Increase coverage allowance? Other existing standards.
Historic Signs Downtown New Sign Type/Process: Increase flexibility or
create new process to allow re-creation of
historic signs that contribute to the period of
significance of a historic building/district?
Other existing standards.
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-5
Sign Options
7
SIGN TYPE LOCATION? WHAT COULD CHANGE?
WHAT WILL NOT
CHANGE?
Secondary Roof Signs Downtown or
Citywide?
New Sign Type: Appropriate districts?
Maximum size? Placement on secondary
roof/canopy?
Other existing standards.
Electronic Message
Centers (EMCs)
Outside of
Downtown
Increase percent of sign face? Increase
color? Increase resolution?
Other existing standards.
Digital Billboards Outside of
Downtown
New Sign Type: Accelerate reduction of
existing billboards through incentive of up to
5 new digital billboard locations?
Could leave code as is:
prohibiting new off-premise
signs.
Interactive Window
Signs
Downtown or
Citywide?
New Sign Type: Appropriate districts?
Maximum size? Brightness?
Other existing standards.
Horizontal or Vertical
Projected Light Signs
Downtown or
Citywide?
New Sign Type: Appropriate districts?
Maximum size? Placement sidewalk or
building? Temporary or permanent? Colors?
Other existing standards.
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-6
Historic Sign Re-Creation
Context: Historic signs
add to Downtown’s
character.
Issues: Some
contemporary signs do not
complement the historic
architecture.
9
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-7
Historic Sign Re-Creation
10
There are 258 commercial
properties of historic age (over 50
years) within the Downtown Zone,
Laurel School Historic District and
Old Town Historic District
Of those, there are 107 buildings
listed on the NRHP or listed as local
landmark buildings
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-8
Historic Sign Re-Creation
11
Sign typically types found
during the periods of
significance are:
• Flush wall signs
• Painted/applied signs
• Signage integrated into
the wall brick
• Roof signs
• Projecting signs
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-9
Historic Sign Re-Creation
12
The City already has a great
program for preserving ghost
signs.
Roof signs are prohibited by
current code
Many of the larger applied
signs and projecting signs
would not meet current code
standards
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-10
13
Should standards be clarified
to allow the re-creation of
historic signs that contribute
to the period of significance
of a historic building or
district?
Should incentives be
offered?
Historic Sign Re-Creation
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-11
Historic Sign Re-Creation
14
To re-create historic signs that do not meet
current regulations we would suggest a process
to include:
• Property owner responsible to research
historic signage of building
• Property owner to demonstrate historic
significance of building following a list of
criteria
• Sign application would be reviewed by staff
and LPC against a set of criteria
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-12
Downtown Signs
Context: Downtown is a vibrant
pedestrian district with particular
historical and cultural significance.
Issue: The current sign
standards are applied city-wide
and not unique to the Downtown
area. The Old Town Design
Guidelines only apply to a portion
of Downtown.
16
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-13
Wall Signs - Size
17
Proportionality and
relationship to building?
Proportionality and
relationship to pedestrian
environment?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-14
Wall Signs - Lighting
18
Lighting and cabinet signs
consistent with Downtown
character?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-15
Projecting Signs
Proportionality and
relationship to building
Flexibility on taller buildings
for vertical signs
Should the maximum height
be calibrated to the height of
the building?
19
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-16
Window Signs – Coverage
20
How much should
window signs cover
window frontage in
Downtown?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-17
Awning – Coverage
21
Should we change our coverage allowance on awnings to
allow something like this Panera Bread location?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-18
Secondary Roof Signs
22
What is your preference for the height
of a secondary roof sign face?
What is your preference for the
location of the sign on the building
(lower floors vs upper floors)?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-19
Electronic Messaging Centers
23
What We are Looking At: Currently in
Place:
• Brightness/Glare
• Sign Face Size
• Height
• Transitions
• Static/Animation
• Timing
• Top Cap
Characteristic Current Code Possible Change
Percent of
Sign Face
50% or less of
total sign face
Increase?
Color 2 colors Increase?
Resolution 16mm pixels Increase resolution
(sharpen images)?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-20
Billboards – Two Paths
30
Path 1: Attrition
Owners remove existing billboards
voluntarily, such as through
redevelopment.
Path 2: Digital Billboards
Owners remove existing billboards in order
to construct a digital billboard.
I-25, S. College Ave., N. College
Ave., Mulberry, Downtown,
Riverside, Mason
Commercial/industrial areas on I-25
and S. College Ave.
Same as existing Need to define digital billboard design
standards
Same as existing Need to define allowable brightness
and glare standards
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-21
Billboards – Two Paths
31
Path 1: Attrition
Owners remove existing billboards
voluntarily, such as through
redevelopment.
Path 2: Digital Billboards
Owners remove existing billboards in order
to construct a digital billboard.
No change to existing sign code. Accelerates reduction of existing
billboards. Supports market demand.
Will take a long time. Digital billboards may not be contribute
to desired character.
Gradual reduction in 80 billboards Digital billboards in up to 5 locations
• Do you prefer to reduce billboards through attrition, or reduce through
conversion to digital billboard?
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-22
Digital Billboards
32
What is the appropriate size of digital billboards?
75 sf
300 sf
672 sf
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-23
Interactive Window Signs
Context: This type of
sign is not currently
allowed in the Sign Code.
Issue:
• Size
• Location
• Brightness
35
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-24
Projected Light Signs
Context: These signs are
entering the commercial
market, though are not yet
widely popular.
Issue: The Sign Code does
not currently address this
type of sign.
38
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-25
Projected Light Signs
39
Horizontal Surface
(sidewalks, parking lots, pavement)
Vertical Surface
(front, side, or rear wall of buildings)
Pedestrians Motorists and pedestrians
Allow within certain distance of
business entrance?
Allow on first story or upper
stories?
Same size and permitting as an
A-frame sign if projected on
public right-of-way.
Would need to define sign permit
requirements.
Limit the path of light from
crossing the public right-of-way
at eye level.
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-26
43
Next Steps
Coffee Talks (March 22)
Finalize Questionnaire Results (end of March)
Draft Code (April)
Public Meetings on Draft Code (May)
P&Z Commission Study Session (May-June)
Adoption Process (June-July)
Other ways to comment
Submit comments online
Schedule a Meeting | Email Noah Beals (nbeals@fcgov.com)
Sign Code Presentation Submitted at Work Session
Packet Pg. 42-27
DATE:
STAFF:
March 14, 2018
Karen McWilliams, Historic Preservation Planner
WORK SESSION ITEM
Landmark Preservation
Commission
SUBJECT FOR DISCUSSION
LPC Work Plan - Progress and Priorities
EXECUTIVE SUMMARY
City Code requires all boards and commissions to file work plans on or before September 30 for the following
year. According to the Boards and Commissions Manual, work plans should set out major projects and issues for
discussion for the following year. The LPC adopted the attached 2018 work plan at its August 16, 2017 meeting.
Beginning with the September 13, 2017 work session, consideration of pending priorities associated with the work
plan will be a regular discussion item. The regular recurrence of this discussion item is intended to provide the
Commission with the opportunity to measure ongoing progress and identify action items.
ATTACHMENTS
1. LPC 2018 Work Plan signed (PDF)
2.1
Packet Pg. 43
2.1.a
Packet Pg. 44
Attachment: LPC 2018 Work Plan signed (6582 : LPC Work Plan - Progress and Priorities)
2.1.a
Packet Pg. 45
Attachment: LPC 2018 Work Plan signed (6582 : LPC Work Plan - Progress and Priorities)
above that limit
across the street.
Where a parcel
with a maximum
of 12-stories in
height is located
immediately across
the street from a
block with a 3-,
4- 5- or 6-story
maximum height
allowance, the
building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Maximum Wall Length
For structures with a structure length over 130 feet, the maximum wall length for the base of the building
(defined as the lower portion of the building below any required upper-story stepbacks) without a Major
Facade Plane Change shall be 50 feet. A Major Facade Plane Change must be a minimum of 2 feet deep and
a minimum of 2’ wide, measured in parallel with and perpendicular to the property line.
Building Articulation
Street-facing facades shall incorporate a minimum of 3 of the following articulation techniques:
1. Minor Facade Plane Changes of a minimum of 3 inches
2. Vertical Projections
3. Horizontal Projects (awnings, cornice articulation)
4. Coordinated window composition between ground floor and all upper floors
5. Balconies or terraces
6. Material Changes
7. Fenestration Detail Requirements, including window depth and sills or lintel requirements
*Note: Development Review Process will determine if building meets this criteria.
III. Building Form:
The following criteria regulate the building’s
form: 1.1.a
Packet Pg. 36
Attachment: Downtown Plan Presentation
above that limit
across the street.
Where a parcel
with a maximum
of 12-stories in
height is located
immediately across
the street from a
block with a 3-,
4- 5- or 6-story
maximum height
allowance, the
building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Maximum Wall Length
For structures with a structure length over 130 feet, the maximum wall length for the base of the building
(defined as the lower portion of the building below any required upper-story stepbacks) without a Major
Facade Plane Change shall be 50 feet. A Major Facade Plane Change must be a minimum of 2 feet deep and
a minimum of 2’ wide, measured in parallel with and perpendicular to the property line.
Building Articulation
Street-facing facades shall incorporate a minimum of 3 of the following articulation techniques:
1. Minor Facade Plane Changes of a minimum of 3 inches
2. Vertical Projections
3. Horizontal Projects (awnings, cornice articulation)
4. Coordinated window composition between ground floor and all upper floors
5. Balconies or terraces
6. Material Changes
7. Fenestration Detail Requirements, including window depth and sills or lintel requirements
*Note: Development Review Process will determine if building meets this criteria.
III. Building Form:
The following criteria regulate the building’s
form: 1.1.a
Packet Pg. 34
Attachment: Downtown Plan Presentation
above that limit
across the street.
Where a parcel
with a maximum
of 12-stories in
height is located
immediately across
the street from a
block with a 3-,
4- 5- or 6-story
maximum height
allowance, the
building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Maximum Wall Length
For structures with a structure length over 130 feet, the maximum wall length for the base of the building
(defined as the lower portion of the building below any required upper-story stepbacks) without a Major
Facade Plane Change shall be 50 feet. A Major Facade Plane Change must be a minimum of 2 feet deep and
a minimum of 2’ wide, measured in parallel with and perpendicular to the property line.
Building Articulation
Street-facing facades shall incorporate a minimum of 3 of the following articulation techniques:
1. Minor Facade Plane Changes of a minimum of 3 inches
2. Vertical Projections
3. Horizontal Projects (awnings, cornice articulation)
4. Coordinated window composition between ground floor and all upper floors
5. Balconies or terraces
6. Material Changes
7. Fenestration Detail Requirements, including window depth and sills or lintel requirements
*Note: Development Review Process will determine if building meets this criteria.
III. Building Form:
The following criteria regulate the building’s
form: 1.1.a
Packet Pg. 32
Attachment: Downtown Plan Presentation
above that limit
across the street.
Where a parcel
with a maximum
of 12-stories in
height is located
immediately across
the street from a
block with a 3-,
4- 5- or 6-story
maximum height
allowance, the
building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Maximum Wall Length
For structures with a structure length over 130 feet, the maximum wall length for the base of the building
(defined as the lower portion of the building below any required upper-story stepbacks) without a Major
Facade Plane Change shall be 50 feet. A Major Facade Plane Change must be a minimum of 2 feet deep and
a minimum of 2’ wide, measured in parallel with and perpendicular to the property line.
Building Articulation
Street-facing facades shall incorporate a minimum of 3 of the following articulation techniques:
1. Minor Facade Plane Changes of a minimum of 3 inches
2. Vertical Projections
3. Horizontal Projects (awnings, cornice articulation)
4. Coordinated window composition between ground floor and all upper floors
5. Balconies or terraces
6. Material Changes
7. Fenestration Detail Requirements, including window depth and sills or lintel requirements
*Note: Development Review Process will determine if building meets this criteria.
III. Building Form:
The following criteria regulate the building’s
form: 1.1.a
Packet Pg. 30
Attachment: Downtown Plan Presentation
above that limit
across the street.
Where a parcel
with a maximum
of 12-stories in
height is located
immediately across
the street from a
block with a 3-,
4- 5- or 6-story
maximum height
allowance, the
building shall
stepback by 10’
from the parcel’s
ground floor
setback on all floors
above that limit
across the street.
Maximum Wall Length
For structures with a structure length over 130 feet, the maximum wall length for the base of the building
(defined as the lower portion of the building below any required upper-story stepbacks) without a Major
Facade Plane Change shall be 50 feet. A Major Facade Plane Change must be a minimum of 2 feet deep and
a minimum of 2’ wide, measured in parallel with and perpendicular to the property line.
Building Articulation
Street-facing facades shall incorporate a minimum of 3 of the following articulation techniques:
1. Minor Facade Plane Changes of a minimum of 3 inches
2. Vertical Projections
3. Horizontal Projects (awnings, cornice articulation)
4. Coordinated window composition between ground floor and all upper floors
5. Balconies or terraces
6. Material Changes
7. Fenestration Detail Requirements, including window depth and sills or lintel requirements
*Note: Development Review Process will determine if building meets this criteria.
III. Building Form:
The following criteria regulate the building’s
form: 1.1.a
Packet Pg. 29
Attachment: Downtown Plan Presentation