Loading...
HomeMy WebLinkAbout04/08/2015 - Landmark Preservation Commission - Agenda - Regular MeetingLandmark Preservation Commission Page 1 April 8, 2015 Ron Sladek, Chair Doug Ernest, Vice Chair City Council Chambers Maren Bzdek City Hall West Meg Dunn 300 Laporte Avenue Kristin Gensmer Fort Collins, Colorado Per Hogestad Dave Lingle Cablecast on City Cable Channel 14 Alexandra Wallace on the Comcast cable system Belinda Zink Laurie Kadrich Karen McWilliams Josh Weinberg Gino Campana Staff Liaison, CDNS Director Preservation Planner Preservation Planner Council Liaison The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224- 6001) for assistance. Regular Meeting April 8, 2015  CALL TO ORDER  ROLL CALL  PUBLIC COMMENT ON ITEMS NOT ON THE AGENDA  DISCUSSION AGENDA 1. CONSIDERATION AND APPROVAL OF THE MINUTES OF THE MARCH 11, 2015 REGULAR MEETING. The purpose of this item is to approve the minutes from the March 11, 2015 regular meeting of the Landmark Preservation Commission. 2. 320 WALNUT STREET, PROPOSED SHADE STRUCTURE PROJECT DESCRIPTION: Final Design Review of Proposed Rooftop Shade Structure APPLICANT: Pete Turner, Illegal Pete’s INC; Tim Politis, One Line Studio LLC Landmark Preservation Commission City of Fort Collins Page 2 3. 508 REMINGTON STREET - CONCEPTUAL AND FINAL DESIGN REVIEW PROJECT DESCRIPTION: The 508 Remington Street property was designated as a Fort Collins Landmark on November 18, 2014, under Standard C, Design/Construction. The applicant has identified changes to earlier plans, which he would like to present to the Commission. As the property is designated, the Commission has Final Design Review authority on any exterior alterations to the building and site. APPLICANT: James MacDowell  OTHER BUSINESS  ADJOURNMENT Agenda Item 1 Item # 1 Page 1 AGENDA ITEM SUMMARY April 8, 2015 Landmark Preservation Commission STAFF Gretchen Schiager, Administrative Assistant SUBJECT CONSIDERATION AND APPROVAL OF THE MINUTES OF THE MARCH 11, 2015 REGULAR MEETING. EXECUTIVE SUMMARY The purpose of this item is to approve the minutes from the March 11, 2015 regular meeting of the Landmark Preservation Commission. ATTACHMENTS 1. Draft LPC March 11, 2015 Minutes (PDF) 1 Packet Pg. 3 Ron Sladek, Chair Doug Ernest, Vice Chair City Council Chambers Maren Bzdek City Hall West Meg Dunn 300 Laporte Avenue Kristin Gensmer Fort Collins, Colorado Per Hogestad Dave Lingle Cablecast on City Cable Channel 14 Alexandra Wallace on the Comcast cable system Belinda Zink Laurie Kadrich Karen McWilliams Josh Weinberg Gino Campana Staff Liaison, CDNS Director Preservation Planner Preservation Planner Council Liaison The City of Fort Collins will make reasonable accommodations for access to City services, programs, and activities and will make special communication arrangements for persons with disabilities. Please call 221-6515 (TDD 224- 6001) for assistance. Regular Meeting March 11, 2015 Minutes • CALL TO ORDER Chair Sladek called the meeting to order at 5:32 p.m. He welcomed a large group of Historic Preservation graduate students from C.S.U. and invited them to ask questions about the process at the end of the meeting. • ROLL CALL PRESENT: Dunn, Zink, Hogestad, Wallace, Gensmer, Lingle, Ernest, Sladek ABSENT: Bzdek (excused) STAFF: McWilliams, Schiager • PUBLIC COMMENT ON ITEMS NOT ON THE AGENDA None. • DISCUSSION AGENDA Landmark Preservation Commission Landmark Preservation Commission Page 1 December 10, 2014 1.a Packet Pg. 4 Attachment: Draft LPC March 11, 2015 Minutes (3060 : Minutes of March 11, 2015) 1. CONSIDERATION AND APPROVAL OF THE MINUTES OF THE FEBRUARY 11, 2015 REGULAR MEETING. The purpose of this item is to approve the minutes from the February 11, 2015 regular meeting of the Landmark Preservation Commission. Mr. Ernest moved that the Landmark Preservation Commission approve the minutes of the February 11, 2015 meeting. Ms. Gensmer seconded. Motion passed 8-0. 2. CONSIDERATION AND APPROVAL OF THE MINUTES OF THE FEBRUARY 25, 2015 REGULAR MEETING. The purpose of this item is to approve the minutes from the February 25, 2015 regular meeting of the Landmark Preservation Commission. Mr. Lingle pointed out that in the Applicant Presentation section of Item #3, there was a reference to Loveland & Daub, which should be changed to Wattle & Daub. Mr. Ernest moved that the Landmark Preservation Commission approve the minutes of the February 25, 2015 meeting with the correction as stated. Ms. Dunn seconded. Motion passed 8-0. [Timestamp: 5:36 p.m.] 3. REMINGTON - LAUREL MINI ROUNDABOUT PROJECT DESCRIPTION: The Engineering Department will be providing Information to the Commission on the Remington Greenway Pilot Project, a portion of which goes through the Laurel School National Register District. Part of this project involves construction of a mini-roundabout at the intersection of Remington and Laurel Streets. APPLICANT: Tim Kemp, Civil Engineer III and Project Manager, City of Fort Collins Staff Report Ms. McWilliams presented the staff report. Applicant Presentation Mr. Kemp gave the Applicant presentation. Public Input None Commission Questions and Discussion A Member inquired about the art, its placement, and whether it would be possible to include a reference to the Historic District. The Applicant said that the art would be at the sidewalk street level with no vertical elements. It would consist of a painted stone in the rain garden area that would reflect at night, and the same treatment would be used at the roundabout. He further stated he would follow up on the question of referencing the Historic District. In response to a question from the Commission, the Applicant explained that a rain garden is a new component to the stormwater regulations, which redirects stormwater through a swale to promote its absorption back into the ground. Sometimes these are planted. A Member asked whether the excavation for the swale would impact previously undisturbed soils. The Applicant believed this section of Remington had been part of a full depth reconstruction completed on most of Remington just 5-7 years ago. There was a question about the project’s relationship to traffic, to which the Applicant responded that the volume of traffic in that area is consistent, and the roundabout was just to handle the existing traffic. Safety and comfort of bicyclists are also being addressed. City of Fort Collins Page 2 1.a Packet Pg. 5 Attachment: Draft LPC March 11, 2015 Minutes (3060 : Minutes of March 11, 2015) A Member asked for clarification on the Commission’s role in the process. Ms. McWilliams noted that this presentation was informational only and was brought to the Commission due to its interest in the Historic District. There is no Federal grant funding involved, and there is no Commission review or need for comments. A Member mentioned that roundabouts typically have a lot of signage that can appear visually cluttered. The point was made that the Commission had previously seen the Linden Street streetscape improvements, and that didn’t have any controversy. The Applicant volunteered that a mini-roundabout doesn’t have as many signs as a typical roundabout. There was questioning about whether the bus stops were new locations, and if they were sheltered. The Applicant said they were adding five concrete bus pads which would include a sign and bench, but will likely not be sheltered since this is a residential area. A Member asked for clarification about the size of the mini-roundabout. The Applicant explained that it would be built within the existing pavement area. It will be about 4” higher than the surrounding pavement, and the widest point would be almost 50’ wide, which is where pedestrians would cross. Chair Sladek thanked Mr. Kemp for his presentation. [Timestamp: 5:57 p.m.] 4. DETERMINATION OF ELIGIBILITY FOR DESIGNATION AS A FORT COLLINS LANDMARK, 408- 410 LINDEN STREET, PURSUANT TO CHAPTER 14 OF THE MUNICIPAL CODE PROJECT DESCRIPTION: This is a request to determine the eligibility of the property at 408-410 Linden Street to qualify as a Fort Collins Landmark, pursuant to Chapter 14 of the Municipal Code APPLICANT: Kim Szidon, Ranch-way Feeds Staff Report Ms. McWilliams presented the staff report. Applicant Presentation None Public Input None Commission Questions and Discussion A Member commented that the Commission was correct in 2002 when they noted that the building had suffered a loss of its architectural integrity. Several other Members agreed, specifically mentioning changes in context and setting. Chair Sladek listed four elements of integrity that have been diminished, including setting, design, feeling and association. Another Member noted that the association with Wilcox was not substantial enough to landmark this property. There was also an error pointed out in the Larimer County Assessor section of the inventory form where it says East Oak Street instead of Linden Street. Ms. McWilliams said they would correct that. Commission Deliberation Ms. Gensmer moved that the Landmark Preservation Commission finds that the building at 408-410 Linden Street does not qualify for individual designation as a Fort Collins Landmark pursuant to Sections 14-1 and 14-5 of the Municipal Code, based upon the findings of the February 2015 survey report by Jason Marmor of RETROSPECT that support the building’s lack of association and integrity. Mr. Lingle seconded. Motion passed 8-0. [Timestamp: 6:07 p.m.] 5. 430 N. COLLEGE, POWER PLANT/ENGINES & ENERGY LAB - CONCEPTUAL AND FINAL REVIEW OF HOPPER DESIGN PROJECT DESCRIPTION: The purpose of this item is to review the proposed design for the hopper, and either approve, approve with conditions, or deny, the application. APPLICANT: Jeff Jensen, JPL Development City of Fort Collins Page 3 1.a Packet Pg. 6 Attachment: Draft LPC March 11, 2015 Minutes (3060 : Minutes of March 11, 2015) Staff Report Ms. McWilliams presented the staff report. Mr. Hogestad recused himself at 6:10 p.m. due to a conflict of interest already on record. Applicant Presentation Mr. Jensen gave a brief presentation. Public Input None Commission Questions and Discussion Members discussed the proposed use of the hopper as a greenhouse. Members mentioned that since the hopper wouldn’t really look like a coal hopper, and would not function as one, it would not create a false sense of historical development. Some Members were conflicted about allowing the hopper at all, while others were more concerned about whether the windows should be allowed since they weren’t on the original hopper. There was discussion about whether the windows could be placed on the back side of the hopper rather than the street side. The Applicant said that wouldn’t make much sense since there is little sun exposure on the north and east sides. Members pointed out that the building had already been changed significantly and had lost much of its original historic character. The Commission referred to the minutes from past meetings of the LPC where there had been discussion about a proposal to reconstruct the smokestacks and the coal hopper, but not the conveyor system. Some said the greenhouse seemed to be in line with the other changes that had been approved previously, further commenting that if they were going to allow the hopper, it didn’t matter if it had windows in it. Given what the LPC had already approved in 2012, some Members expressed a need to be consistent. Members were particularly concerned that the windows appeared to be blue in the rendering. The Applicant assured the Commission that the windows would be clear translucent. Chair Sladek asked if everyone was ready for final review, and the Members indicated they were. Commission Deliberation Mr. Ernest moved that the Landmark Preservation Commission approve the final review of the proposed greenhouse for the coal hopper at 430 North College Avenue, Power Plant/Engines & Energy Lab, upon the condition that the greenhouse has clear translucent glazing in its glass, finding that it is in compliance with Section 14-48 of the Municipal Code and the Secretary of Interior Standards. Ms. Wallace seconded. Motion passed 7-0. Mr. Hogestad rejoined the Commission at 6:46 p.m. [Timestamp: 6:46 p.m.] 6. 301 SOUTH LOOMIS AVENUE - STATE TAX CREDIT PART 2 PROJECT DESCRIPTION: Final Review — Part 2 State Tax Credit Review for Roofing of the David E. Watrous House and Garage, 301 South Loomis Avenue APPLICANT: Chester Daniel Staff Report Ms. McWilliams presented the staff report. Applicant Presentation Mr. Daniel introduced himself and was available for questions, but did not give a presentation. Public Input None City of Fort Collins Page 4 1.a Packet Pg. 7 Attachment: Draft LPC March 11, 2015 Minutes (3060 : Minutes of March 11, 2015) Commission Questions and Discussion Ms. Dunn asked whether the project timeline complied with the guidelines. Ms. McWilliams indicated that the project timing met the criteria. Commission Deliberation Mr. Lingle moved that the Landmark Preservation Commission, acting as a reviewing entity under CRS Section 39-22-514, grants Part 2 State Tax Credit for Historic Preservation approval of the rehabilitation and restoration work on the David E. Watrous House and Garage at 301 South Loomis Avenue. Ms. Dunn seconded. Motion passed 8-0. • OTHER BUSINESS None • ADJOURNMENT Chair Sladek adjourned the meeting at 6:56 p.m. After adjournment, the Commission entertained questions from the students in the audience, which are not part of the meeting record. Minutes respectfully submitted by Gretchen Schiager. City of Fort Collins Page 5 1.a Packet Pg. 8 Attachment: Draft LPC March 11, 2015 Minutes (3060 : Minutes of March 11, 2015) Agenda Item 2 Item # 2 Page 1 STAFF REPORT April 8, 2015 Landmark Preservation Commission PROJECT NAME 320 WALNUT STREET, PROPOSED SHADE STRUCTURE STAFF Josh Weinberg, City Planner PROJECT INFORMATION PROJECT DESCRIPTION: Final Design Review of Proposed Rooftop Shade Structure APPLICANT: Pete Turner, Illegal Pete’s INC; Tim Politis, One Line Studio LLC EXECUTIVE SUMMARY BACKGROUND: The building at 320 Walnut Street, formerly the Goodwill Building and now housing Illegal Pete’s, is located within the National, State, and local Historic Old Town District. This simple one story blonde brick façade building was likely constructed as an automotive garage. In 1933, it was the Fort Collins Rubber Company, followed in 1935 by the Farr-King Implement Company. In the late 1940s, it became the Montgomery Ward Farm Store and Warehouse, a use it fulfilled until circa 1965, when it became Goodwill Industries. Building permits exist for unspecified remodeling work in 1924 and 1929. In 1936, when it was the Farr-King Implement Company, the building’s rear door was enlarged to 12’ x 12’, housing an overhead wood door. A new chimney was built in 1938, and another, unspecified, remodel occurred in 1948. A final “front facing remodel” took place in 1959. At some point in its history, the garage bay openings on either side of the central door were turned into storefront windows. Illegal Pete’s restaurant recently rehabilitated the building, including, most notably, the addition of a rooftop addition; a new storefront system with rollup doors, which references the historic garage doors once present on the façade; and rehabilitation of historic masonry elements and wood windows. This work was approved by the Commission on April 7, 2014. The property owner is now returning with plans to complete the rehabilitation project by installing a shade structure over the building’s rooftop patio, which is just south of the recently constructed rooftop addition. PROJECT DESCRIPTION: The applicant has provided the following description of the proposed project: “To complement the previously approved rooftop addition and patio, we are proposing a shade structure to enhance the existing building uses and allow for more comfortable use of the rooftop during periods of peak sunlight. The proposed shade structure will help to activate the rooftop patio during daytime hours, and can promote activity along the surrounding public ways including Walnut Street and Seckner Alley, overall enhancing the vitality of the surrounding district. The design of the roof top shade structure is intended to be minimal. Design features that contribute to this goal include: 2 Packet Pg. 9 Agenda Item 2 Item # 2 Page 2  The proposed structure is setback 11’-10”from the primary façade and continues for a distance of 18’-9 1/2” perpendicular to Walnut Street. The setback is intended to allow the shade structure to serve a ‘background role’ that is secondary to the primary street façade.  A single span beam extends nearly 50’-0” parallel to the Walnut Street façade, serving to frame the historic structure below.  The proposed structure is to be painted dark bronze to match the existing rooftop structure beyond. The dark bronze color contrasts the light golden brick color of the historic structure below. Visually, the light brick color becomes foreground while the dark colored roof top structure recedes into the background; thus, maintaining the original hierarchy and primacy of the original street level façade.  The vertical supports align with the existing brick pilasters, maintaining the original structural pattern and rhythm. Furthermore, the existing brick pilasters serve to partially conceal the new vertical steel supports from view.  The vertical supports extend down from the existing top of parapet by a distance of 4’-0” to 6’-0.” As a result, the vertical supports are above the line of sight when viewed down Seckner Alley.  The proposed through-bolts at the vertical supports are designed to have a minimal impact to the existing brick structure. In the event that the roof top shade structure were removed, the holes would be patched and repaired. The structural integrity would not be impacted.  Moreover, the new addition is differentiated from the older structure by use of contemporary building materials including the use of contemporary steel members to contrast the older structure.  While essential to the function of the restaurant, the design of the new rooftop shade structure minimizes its impact to the existing building.” Please reference the enclosed packet from the applicant for elevations, photographs, and narrative regarding the proposal. The applicant’s narrative contains a project description and specific responses to many of the provisions outlined in the Secretary of the Interior’s Standards for Rehabilitation. Review Criteria: The applicant is seeking Final Design Approval at this time. Alterations to properties in Fort Collins Landmark Districts are reviewed for compliance with Municipal Code Section 14-48, “Approval of Proposed Work,” the Secretary of the Interior’s standards for Rehabilitation, and the Old Town Historic District Design Standards. While the Design Standards to not provide specific guidance for design of rooftop shade structures, the most applicable sections of the document are found on pages 59-63 and 73-74. The Old Town Historic District Design Standards can be referenced here: http://www.fcgov.com/historicpreservation/pdf/old-town-design-guidelines.pdf. Sec. 14-48. Approval of proposed work. In determining the decision to be made concerning the issuance of a report of acceptability, the Commission shall consider the following criteria: (1) The effect of the proposed work upon the general historical and/or architectural character of the landmark or landmark district; (2) The architectural style, arrangement, texture and materials of existing and proposed improvements, and their relation to the sites, structures and objects in the district; (3) The effects of the proposed work in creating, changing or destroying the exterior characteristics of the site, structure or object upon which such work is to be done; (4) The effect of the proposed work upon the protection, enhancement, perpetuation and use of the landmark or landmark district; (5) The extent to which the proposed work meets the standards of the city and the United States Secretary of the Interior then in effect for the preservation, reconstruction, restoration or rehabilitation of historic resources. Secretary of the Interior’s Standards for Rehabilitation Rehabilitation is defined as the act or process of making possible a compatible use for a property through repair, alterations, and additions while preserving those portions or features which convey its historical, cultural, or 2 Packet Pg. 10 Agenda Item 2 Item # 2 Page 3 architectural values.  Rehabilitation Standard 1. A property will be used as it was historically or be given a new use that requires minimal change to its distinctive materials, features, spaces, and spatial relationships;  Rehabilitation Standard 2. The historic character of a property will be retained and preserved. The removal of distinctive materials or alteration of features, spaces, and spatial relationships that characterize a property will be avoided.  Rehabilitation Standard 3. Each property will be recognized as a physical record of its time, place, and use. Changes that create a false sense of historical development, such as adding conjectural features or elements from other historic properties, will not be undertaken.  Rehabilitation Standard 4. Changes to a property that have acquired historic significance in their own right will be retained and preserved.  Rehabilitation Standard 5. Distinctive materials, features, finishes, and construction techniques or examples of craftsmanship that characterize a property will be preserved.  Rehabilitation Standard 6. Deteriorated historic features will be repaired rather than replaced. Where the severity of deterioration requires replacement of a distinctive feature, the new feature will match the old in design, color, texture, and, where possible, materials. Replacement of missing features will be substantiated by documentary and physical evidence.  Rehabilitation Standard 7. Chemical or physical treatments, if appropriate, will be undertaken using the gentlest means possible. Treatments that cause damage to historic materials will not be used.  Rehabilitation Standard 8. Archeological resources will be protected and preserved in place. If such resources must be disturbed, mitigation measures will be undertaken.  Rehabilitation Standard 9. New additions, exterior alterations, or related new construction will not destroy historic materials, features, and spatial relationships that characterize the property. The new work shall be differentiated from the old and will be compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment.  Rehabilitation Standard 10. New additions and adjacent or related new construction will be undertaken in such a manner that, if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired. Commission Action: This is a request for a Final Design Review of the proposal to add a shade structure to the roof of the building at 320 Walnut Street. If the Commission desires, it may adopt a motion stating the proposed design complies with applicable standards for rehabilitation projects within the Old Town Historic District, with or without conditions. The Commission can also adopt a motion stating why the proposed design does not comply with applicable standards for rehabilitation projects within the Old Town Historic District. ATTACHMENTS 1. 15-0317_Landmark Submittal (PDF) 2. 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (PDF) 3. Weeks & Associates - Shade Structure Summary (PDF) 2 Packet Pg. 11 Linden Street Old Firehouse Alley Seckner Alley Walnut Street Walnut Street Entry Demising Wall Existing Rooftop Addition Existing Rooftop Patio 50.0’ 180.1’ 320 Walnut Street Existing Use: Restaurant | Bar To Be Determined Zone: D Zone: D Zone: D Zone: D Zone: D Zone: D 0’ 100’ N Orientation Plan | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 Alley Entry Indicates Image Number and View Vantage Point. Images can be found on the proceeding pages. 1 3 4 2 Proposed Rooftop Sunshade 1 2.a Packet Pg. 12 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Existing Photos | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 2.a Packet Pg. 13 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Image 1 | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 View from Walnut looking north. The proposed dark bronze shade structure recedes into the background matching the existing rooftop structure beyond. In contrast, the historic brick façade is drawn to the foreground with its light colored golden brick pattern. When viewed from street level, the historic facade maintains its hierarchical signifi cance and distinct character. Proposed EXISTING ROOFTOP STRUCTURE PROPOSED SUNSHADE STRUCTURE EXISTING STOREFRONT AND ENTRANCE 2.a Packet Pg. 14 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Image 2 | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 View from Walnut looking northwest. The existing historic building is characterized by brickwork with entrances and storefronts in a dark bronze color. To accent the historic facade and minimize the presence of the shade structure, we propose to set the structure back approximately 12’ from the front facade. Proposed EXISTING ROOFTOP STRUCTURE PROPOSED SUNSHADE STRUCTURE EXISTING STOREFRONT AND ENTRANCE 2.a Packet Pg. 15 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Image 3 | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 View from Walnut Street looking southeast. Note that the proposed addition is stepped back from the street. Trees in the ROW further serve to conceal the new structure. Proposed EXISTING STOREFRONT AND ENTRANCE PROPOSED SUNSHADE STRUCTURE 2.a Packet Pg. 16 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Image 4 | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 View from Seckner Alley looking south. Note that the proposed structure does not continue to the ground, rather it continues approximately 4’6” from the top of the existing parapet, partially concealed by the existing brick pilasters. Proposed PROPOSED SUNSHADE STRUCTURE EXISTING MASONRY WALL STRUCTURE BOLTED TO EXISTING WALL 2.a Packet Pg. 17 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Partial Roof Plan | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 Seckner Alley Walnut Street 2.a Packet Pg. 18 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) Partial Structural Plan | 320 Walnut Street | One Line Studio & Xan Creative | 17 March 2015 Structural framing plan prepared by Weeks and Associates Seckner Alley Walnut Street 2.a Packet Pg. 19 Attachment: 15-0317_Landmark Submittal (3046 : 320 Walnut Street, Proposed Shade Structure) 1ine studio 6900 East Belleview Avenue, Suite 350|Greenwood Village, CO 80111|p: 303.437.7712|e: politis.onelinestudio@gmail.com 1 One Line Studio LLC 6900 East Belleview Ave. Suite 350 Greenwood Village, CO 80111 30 March 2015 Landmark Commission City of Fort Collins Project: 320 Walnut Street, Fort Collins, Colorado – Proposed Shade Structure Dear members of the Landmark Commission and city staff, We greatly appreciate the opportunity to continue working with the Landmark Commission following our experience nearly a year ago. Since the Landmark Commission’s approval of the design submittal for 320 Walnut Street in 2014, the building has been improved and we now have an active district destination that maintains the original character of the brick building and compliments the existing urban fabric included in the historic district of old town Fort Collins. Last spring, when we began the Landmark review process we initially proposed a shade structure for the rooftop patio. During the Concept review meeting with the Landmark Commission, the proposed shade structure was received favorably, however more detail was requested. Following the initial meeting we realized that due to the project schedule, we were unable to provide the necessary details in a timely manner. In a follow up conversation with Josh Weinberg, we elected to take the shade structure out of the final submittal, with the understanding that it would be submitted at a later time. Since then, we have worked through the structural design with Weeks and Associates in Fort Collins and have come to a solution that will provide shade to the rooftop patio while maintaining the unique historic character of the original building below. Our project goals remain unchanged; preserving the built environment and the character built upon generations of development is essential to establishing a sense of place. As a sustainable practice, the reuse and adaptation of historical elements equates to being respectful of the local environment, being part of a community and being a good neighbor. At 320 Walnut Street, the proposed design aims to:  Maintain the original character of the brick building.  Preserve the existing prominence and contributing character of the 1st floor exterior façade on Walnut Street. Sequentially, all new structures should take a tributary and/or background role in terms of visual presence.  Establish an active district destination by providing shade to a rooftop patio that compliments the existing structure and promotes a dynamic, urban environment that will support the use of this historic structure and the surrounding district. 2.b Packet Pg. 20 Attachment: 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (3046 : 320 Walnut Street, Proposed 1ine studio 6900 East Belleview Avenue, Suite 350|Greenwood Village, CO 80111|p: 303.437.7712|e: politis.onelinestudio@gmail.com 2 We have prepared a project description describing the design and included a narrative outlining compliance with the Secretary of the Interior’s Standards for Rehabilitation. Additionally, we have included a stamped letter from Weeks and Associates describing the proposed structural addition in detail. We appreciate the opportunity to submit improvements to 320 Walnut Street for your review and request your approval to proceed with the proposed design. Respectfully, Tim Politis, AIA, LEED AP One Line Studio LLC Project Description: To complement the previously approved rooftop addition and patio, we are proposing a shade structure to enhance the existing building uses and allow for more comfortable use of the rooftop during periods of peak sunlight. The proposed shade structure will help to activate the rooftop patio during daytime hours, and can promote activity along the surrounding public ways including Walnut Street and Seckner Alley, overall enhancing the vitality of the surrounding district. The design of the roof top shade structure is intended to be minimal. Design features that contribute to this goal include:  The proposed structure is setback 11’-10”from the primary façade and continues for a distance of 18’-9 1/2” perpendicular to Walnut Street. The setback is intended to allow the shade structure to serve a ‘background role’ that is secondary to the primary street façade.  A single span beam extends nearly 50’-0” parallel to the Walnut Street façade, serving to frame the historic structure below.  The proposed structure is to be painted dark bronze to match the existing rooftop structure beyond. The dark bronze color contrasts the light golden brick color of the historic structure below. Visually, the light brick color becomes foreground while the dark colored roof top structure recedes into the background; thus, maintaining the original hierarchy and primacy of the original street level façade.  The vertical supports align with the existing brick pilasters, maintaining the original structural pattern and rhythm. Furthermore, the existing brick pilasters serve to partially conceal the new vertical steel supports from view.  The vertical supports extend down from the existing top of parapet by a distance of 4’-0” to 6’-0.” As a result, the vertical supports are above the line of sight when viewed down Seckner Alley.  The proposed through-bolts at the vertical supports are designed to have a minimal impact to the existing brick structure. In the event that the roof top shade structure were removed, the holes would be patched and repaired. The structural integrity would not be impacted. 2.b Packet Pg. 21 Attachment: 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (3046 : 320 Walnut Street, Proposed 1ine studio 6900 East Belleview Avenue, Suite 350|Greenwood Village, CO 80111|p: 303.437.7712|e: politis.onelinestudio@gmail.com 3  Moreover, the new addition is differentiated from the older structure by use of contemporary building materials including the use of contemporary steel members to contrast the older structure. While essential to the function of the proposed restaurant, the design of the new rooftop shade structure minimizes its impact to the existing building. The following criteria and responses are referenced from the Secretary of the Interior’s Standards for Rehabilitation: 1. A property will be used as it was historically or be given a new use that requires minimal change to its distinctive materials, features, spaces, and spatial relationships. Response: The proposed design maintains the existing brick features, spatial relationships and features of the original design. As part of the existing improvements, openings that had previously been covered have been restored. The proposed roof top shade structure is setback from the street by nearly 11’-10” and takes a background role in regard to visual hierarchy. This is further enhanced by the proposed colors. The proposed dark bronze shade structure recedes into the background matching the existing rooftop structure beyond. In contrast, the historic brick façade is drawn to the foreground with its light colored golden brick pattern. When viewed from street level, the historic facade maintains its hierarchical significance and distinct character. 2. The historic character of a property will be retained and preserved. The removal of distinctive materials or alteration of features, spaces, and spatial relationships that characterize a property will be avoided. Response: The proposed design preserves the existing materials and maintains existing relationships. 3. Each property will be recognized as a physical record of its time, place, and use. Changes that create a false sense of historical development, such as adding conjectural features or elements from other historic properties, will not be undertaken. Response: The new rooftop shade structure is to match the previously approved rooftop addition in color and appearance. The previously approved rooftop addition uses contemporary materials such as standing seam metal panels to contrast the older structure using a dark bronze tone in lieu of the light golden color of the historic façade. The proposed shade structure will use contemporary steel members and will be painted to match the dark bronze color. The proposed design does not create a false sense of historical development; rather, it builds upon the character of the existing building. 2.b Packet Pg. 22 Attachment: 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (3046 : 320 Walnut Street, Proposed 1ine studio 6900 East Belleview Avenue, Suite 350|Greenwood Village, CO 80111|p: 303.437.7712|e: politis.onelinestudio@gmail.com 4 4. Changes to a property that have acquired historic significance in their own right will be retained and preserved. Response: Noted. The proposed shade structure will not be impacting the existing building features. 5. Distinctive materials, features, finishes, and construction techniques or examples of craftsmanship that characterize a property will be preserved. Response: The evident craft most pronounced in the existing structure’s brick detailing, is to be maintained as is. The proposed roof top shade structure is meant to be minimal in nature, framing the character and features of the prominent street level façade below. 6. Deteriorated historic features will be repaired rather than replaced. Where the severity of deterioration requires replacement of a distinctive feature, the new feature will match the old in design, color, texture, and, where possible, materials. Replacement of missing features will be substantiated by documentary and physical evidence. Response: Noted. At this time, we do not anticipate that the proposed shade structure will impact any of the existing building features. 7. Chemical or physical treatments, if appropriate, will be undertaken using the gentlest means possible. Treatments that cause damage to historic materials will not be used. Response: Noted. 8. Archeological resources will be protected and preserved in place. If such resources must be disturbed, mitigation measures will be undertaken. Response: Not applicable. 9. New additions, exterior alterations, or related new construction will not destroy historic materials, features, and spatial relationships that characterize the property. The new work shall be differentiated from the old and will be compatible with the historic materials, features, size, scale and proportion, and massing to protect the integrity of the property and its environment. Response: To activate the building and the surrounding public ways, a rooftop addition and patio is desired. In consideration of the design criteria, the contemporary addition will be set back from the primary façade on Walnut. The goal is to minimize visibility of the new structure from Walnut Street and the surrounding alleys. Moreover, the new addition is differentiated from the older structure by use of contemporary building materials including the use of contemporary steel members, the subtle coloring of the shading material and the proposed dark bronze paint color to contrast the older structure. As a special note, the new structure is intended to extend from the top of the existing parapet down the existing walls for a length of up to 6 feet. This places the structure above one’s eye level when walking along Seckner Alley. Furthermore, the new vertical structure is positioned in the corner pocket of the existing brick pilasters. Together, these proposed 2.b Packet Pg. 23 Attachment: 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (3046 : 320 Walnut Street, Proposed 1ine studio 6900 East Belleview Avenue, Suite 350|Greenwood Village, CO 80111|p: 303.437.7712|e: politis.onelinestudio@gmail.com 5 design features minimize the presence of the structure to maintain the distinguished character of the original brick building. 10. New additions and adjacent or related new construction will be undertaken in a such a manner that, if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired. Response: Noted. Being set back from the parapet and concealed from view, should the proposed roof top shade structure be removed, the essential form and integrity of the historic property and its environment would be unimpaired. 2.b Packet Pg. 24 Attachment: 15-0330_320 Walnut Street - Landmark Commission Submittal - Proposed Shade Structure (3046 : 320 Walnut Street, Proposed 2.c Packet Pg. 25 Attachment: Weeks & Associates - Shade Structure Summary (3046 : 320 Walnut Street, Proposed Shade Structure) Agenda Item 3 Item # 3 Page 1 STAFF REPORT April 8, 2015 Landmark Preservation Commission PROJECT NAME 508 REMINGTON STREET - CONCEPTUAL AND FINAL DESIGN REVIEW STAFF Karen McWilliams, Historic Preservation Planner PROJECT INFORMATION PROJECT DESCRIPTION: The 508 Remington Street property was designated as a Fort Collins Landmark on November 18, 2014, under Standard C, Design/Construction. The applicant has identified changes to earlier plans, which he would like to present to the Commission. As the property is designated, the Commission has Final Design Review authority on any exterior alterations to the building and site. APPLICANT: James MacDowell OWNER: James MacDowell EXECUTIVE SUMMARY AUTHORITY: The 508 Remington Street property was designated as a Fort Collins Landmark on November 18, 2014, with Council’s adoption of Ordinance No. 162, 2014. The property was recognized for its high degree of integrity combined with its significance to the community under Standard C, Design/Construction. The nomination notes the building’s “…architectural merits as an exceptionally detailed, well-preserved example of a Queen Anne style residence, with especially noteworthy [and] very intricate, brickwork.” PROJECT: Prior to the property’s designation, the Commission held a Preliminary State Tax Credit review at its August 27, 2014 Work Session, at which time it heard detailed information on the proposed rehabilitation of the building. The work is well underway. The owner, James MacDowell, has identified the following changes he would like to discuss with the Commission. As the property is now designated, the Commission has Final Design Review authority on any exterior alterations to the building and site. Once the project is completed, the owner will be submitting an application for State Tax Credits for both the exterior and interior work. Interior alterations may be reviewed by the Commission for compliance with the Secretary of the Interior Standards for potential State Tax Credit funding. Changes to earlier plans:  Proposal: reverse direction of basement entry stair  Proposal: close off W exterior doorway on addition  Proposal: add E entry door and deck on addition  Proposal: convert wood-burning fireplace to gas (interior)  Proposal: continue privacy fence on north lot line COMMISSION ACTION and REVIEW CRITERIA: If the Commission finds that sufficient information has been presented, it may adopt a motion to consider the request as a Final Design Review. The applicable criteria for 3 Packet Pg. 26 Agenda Item 3 Item # 3 Page 2 Design Reviews of designated landmark properties is Municipal Code Section 14-48, “Approval of Proposed Work,” which includes the Secretary of the Interior’s Standards for Rehabilitation. The Commission would then review each change to the exterior of the building, and determine if all, some, or none of the alterations meet the Standards in Section 14-48, and should adopt a motion to this effect. The proposed change to the interior of the building does not require Commission action; however, as the item is likely to come before the Commission later, as part of a State Tax Credit application, it would be very beneficial to the applicant to have a discussion regarding its meeting, or not meeting, the Secretary of the Interior’s Standards for Rehabilitation. Sec. 14-48. Approval of proposed work. In determining the decision to be made concerning the issuance of a report of acceptability, the Commission shall consider the following criteria: (1) The effect of the proposed work upon the general historical and/or architectural character of the landmark or landmark district; (2) The architectural style, arrangement, texture and materials of existing and proposed improvements, and their relation to the sites, structures and objects in the district; (3) The effects of the proposed work in creating, changing or destroying the exterior characteristics of the site, structure or object upon which such work is to be done; (4) The effect of the proposed work upon the protection, enhancement, perpetuation and use of the landmark or landmark district; (5) The extent to which the proposed work meets the standards of the city and the United States Secretary of the Interior then in effect for the preservation, reconstruction, restoration or rehabilitation of historic resources. The Secretary of the Interior’s Standards for Rehabilitation: 1. A property shall be used for its historic purpose or be placed in a new use that requires minimal change to the defining characteristics of the building and its site and environment. 2. The historic character of a property shall be retained and preserved. The removal of historic materials or alteration of features and spaces that characterize a property shall be avoided. 3. Each property shall be recognized as a physical record of its time, place, and use. Changes that create a false sense of historical development, such as adding conjectural features or architectural elements from other buildings, shall not be undertaken. 4. Most properties change over time; those changes that have acquired historic significance in their own right shall be retained and preserved. 5. Distinctive features, finishes, and construction techniques or examples of craftsmanship that characterize a property shall be preserved. 6. Deteriorated historic features shall be repaired rather than replaced. Where the severity of deterioration requires replacement of a distinctive feature, the new feature shall match the old in design, color, texture, and other visual qualities and, where possible, materials. Replacement of missing features shall be substantiated by documentary, physical, or pictorial evidence. 7. Chemical or physical treatments, such as sandblasting, that cause damage to historic materials shall not be used. The surface cleaning of structures, if appropriate, shall be undertaken using the gentlest means possible. 3 Packet Pg. 27 Agenda Item 3 Item # 3 Page 3 8. Significant archeological resources affected by a project shall be protected and preserved. If such resources must be disturbed, mitigation measures shall be undertaken. 9. New additions, exterior alterations, or related new construction shall not destroy historic materials that characterize the property. The new work shall be differentiated from the old and shall be compatible with the massing, size, scale, and architectural features to protect the historic integrity of the property and its environment. 10. New additions and adjacent or related new construction shall be undertaken in such a manner that if removed in the future, the essential form and integrity of the historic property and its environment would be unimpaired. ATTACHMENTS 1. 508 Remington _ Proposed exterior modifications _ 2015-04-07 (PDF) 2. 508 Remington _ basement stairwell plans (PDF) 3 Packet Pg. 28 Proposal for exterior modifications; update on progress to date 508 Remington St. Fort Collins, CO 80524 April 07, 2015 3.a Packet Pg. 29 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 1 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 30 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 2 Proposal: reverse direction of basement entry stair Context: • LPC previously approved conversion of existing window well on east side of building to new basement entry stair • Prior proposal was to have the stairs exit towards the east • After further review and discussion with contractors, believe better approach will be to have stairs exit towards the west Rationales: • More natural entry path to basement unit – entry from street without having to “double back” • Improved aesthetic experience, safety and security vs. entry/exit via closed-in corner • Increased natural light to basement unit Proposal: • Have basement entry exit westward rather than eastward, with entry stairwell terminating east of westward building edge 3.a Packet Pg. 31 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 3 Picture: existing window well / site of planned basement entry stair 3.a Packet Pg. 32 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 4 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 33 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 5 Proposal: close off west exterior doorway on addition Rationales: • Create additional wall space in main floor kitchen to add storage / cabinetry • [In conjunction with adding sliding door at east end of kitchen]: Create better foot traffic flow in main floor unit, give unit direct / restricted access to back yard Proposal: • Remove entry door, replace with monolithic infill, frame, insulate, and enclose from interior as rear wall of added storage closet – Option: retain existing door (remove screen door), permanently close and weatherseal, blank out glass from interior, frame, insulate, and enclose from interior as rear wall of added storage closet • Remove stoop and handrail, clean off deteriorated concrete affixed to original foundation • Add planting in place of existing stoop to obscure visibility of former doorway 3.a Packet Pg. 34 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 6 Picture: current entry door at west elevation of addition (1 of 2) 3.a Packet Pg. 35 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 7 Picture: current entry door at west elevation of addition (2 of 2) 3.a Packet Pg. 36 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 8 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 37 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 9 Proposal: add entry door and deck on east elevation of addition Rationales: • Create better foot traffic flow in main floor unit, give unit direct / restricted access to back yard • [In conjunction with closing off existing kitchen entry door]: Create additional wall space in main floor kitchen to add storage / cabinetry Proposal: • Build a ~6’ D x 8’x W deck at east end of addition; pressure- treated pine posts, framing and balusters, composite decking and top rail; stairs descending eastward to yard on north end • Replace existing 36” W x 48” H grid/pane window with 60” W x 80” H sliding patio door with interior grid – Option: use French door instead. Note that in-swing will conflict with outswing bathroom entry door; out-swing will reduce usable deck area by ~50% and conflict with stair access 3.a Packet Pg. 38 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 10 Picture: east elevation of addition 3.a Packet Pg. 39 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 11 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 40 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 12 Proposal: convert wood-burning fireplace to gas Rationales: • Fireplace is currently unsafe to use, as firebox and flue were unprofessionally relined; lining is cracked and deteriorating • Long-term intention is to hold (triplex) property as a rental; accordingly have a strong preference to not leave a wood-burning facility in place Proposal: • Install a Fireplace Xtrordinair 31DVl direct vent gas insert with Black Metropolitan face, custom size black surround and chimney liner kit. – Note that due to dimensions of opening, there are very limited options available without widening opening and damaging tile surround • Retain all existing features, with slight trim overlap on existing tile surround – Note that due to dimensions of opening, there would be matte-black trim plates above and below insert • Exterior vent cap design to be approved by Historic / LPC 3.a Packet Pg. 41 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 13 Picture: existing fireplace 3.a Packet Pg. 42 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 14 Picture: proposed gas insert 3.a Packet Pg. 43 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 15 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 44 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 16 Proposal: continue privacy fence on north lot line Rationales: • High traffic on alley adjacent to north lot line from adjacent apartment building, with accompanying noise and trash • Bedroom windows face alley, creating both a noise and security issue Proposal: • Continue existing privacy fence on north lot line towards street • Stop short of westward building edge, turn south into building (into large low-feature area on exterior of interior stairwell) • No attachment to building • Stained cedar construction, 3.5” pickets, to match existing 3.a Packet Pg. 45 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 17 Picture: lot line, existing privacy fence 3.a Packet Pg. 46 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 18 Picture: planned terminus of privacy fence continuation 3.a Packet Pg. 47 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 19 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 48 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 20 Upstairs kitchen 3.a Packet Pg. 49 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 21 Upstairs kitchen: before 3.a Packet Pg. 50 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 22 Upstairs kitchen: comments on changes vs. original proposal • Change in layout – vs. original peninsula proposal, went with a galley design to maximize floor space (driven by lack of a true living/family room area) • Correction to cabinetry proposal – original proposal was an (erroneous) copy-paste of downstairs kitchen proposal. Upstairs kitchen lacked any true existing cabinetry to “match” – rather was simply recent 2x4 & plywood construction, with a single cabinet door with basic recent-manufacture pull. Replaced with wood cabinetry throughout, pulls TBD. 3.a Packet Pg. 51 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 23 Upstairs bedrooms 3.a Packet Pg. 52 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 24 Upstairs bathroom – picture #1 3.a Packet Pg. 53 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 25 Upstairs bathroom – picture #2 3.a Packet Pg. 54 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 26 Grounds: recovered 24” W flagstone slabs Recovered from around property, some previously in use, some buried ~6-12” deep Will be used to create walkway from front sidewalk to rear parking area 3.a Packet Pg. 55 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 27 Northeast entry stairs / deck Existing entry stairs / deck were severely deteriorated and unsafe for use. Replicating existing materials (untreated pine) would not have resulted in a durable replacement. Replaced with new entry stairs/deck; cedar frame, post, & balusters, composite decking and top rail; free-standing, not affixed to building. In-process grading work will cover forms. Ran replacement deck to currently closed-off exterior door to create option to restore exterior door in future. Railings added to code. DETERIORATED STAIRS/DECK REPLACEMENT 3.a Packet Pg. 56 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 28 Agenda Proposal: reverse direction of basement entry stair Proposal: close off W exterior doorway on addition Proposal: add E entry door and deck on addition Proposal: convert wood-burning fireplace to gas Update: progress to date Appendix: footprint; original scope of work Proposal: continue privacy fence on north lot line 3.a Packet Pg. 57 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 29 51 i REMINGTON PARKING PARKING PROPOSED BASEMENT STAIRWAY PROPOSED ENTRY DOOR INFILL PROPOSED FENCE EXTENSION PROPOSED DECK PROPOSED ENTRY DOOR PROPOSED ADDITIONAL FENCE S N W E 10' Building footprint 3.a Packet Pg. 58 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 30 Planned restorations and rehabilitations 1 of 8: Building exterior Architectural feature Item # Feature and its condition: Work/impact on feature: Expected cost Photo #(s) Building exterior 1 Painted brick, shingling and trim; cream body and purple and pink accents; significantly deteriorated in numerous areas. Touch up exterior paint where deteriorated. Match existing paint colors. $1,300 Ex-all 2 Stairs/deck at NE corner of building are recent construction with painted dimensional lumber; severely deteriorated. Replace with matching design and materials. $300 Ex-10 3 Gutters are half rounds with flat edges, fastened to the roof with wire, with a painted finish. Severely damaged, with extensive rust; detached from structure in some areas. Repair/replace gutter & downspout at NW and S sides; add new gutter & downspout at NE corner to alleviate significant seepage in basement NE corner $950 Ex-10, -13, - 14 4 Negative drainage on north side of building; contributes to seepage in basement Increase grade slope away from building on north side $250 Ex-10, 11 5 Original foundation masonry is deteriorated Tuckpoint foundation where required $600 e.g. Ex-9 6 Windows on original structure are primarily 508 Remington _ Proposed exterior modifications _ 2015-03-26 31 Planned restorations and rehabilitations 2 of 8: Building exterior Architectural feature Item # Feature and its condition: Work/impact on feature: Expected cost Photo #(s) Building exterior 7 [see previous entry] Install exterior-mount storm/screen combination windows $3,200 (same) 8 Wood frame windowed exterior doors. Carved wood-frame screen doors at front and balcony entries. Simple wood frame south screen door. Weatherstrip exterior doors (4) $100 1-3, 14, 33 (continues on next page) 9 Two-layer composite shingle over shake. Two exterior chimneys at south and east sides; interior chimney centered ~6' west of east chimney. 3" black waste vent stack on west slope of south gable. 4" white waste vent stack on east slope of east roof. 4" vent hood, painted to match body, on east wall of 1965 addition. Add three gooseneck roof vents in black finish, on east slope of south gable, for 2nd floor laundry, bath, and kitchen Add two gooseneck roof vents in black finish, on north slope of east gable roof, for 1st floor kitchen and north bath $850 Ex-4B 10 Double-wall painted brick walls on sandstone block foundation Add two vent hoods finished to match exterior body, to east of north footprint projection through north first floor brick, for first floor laundry 508 Remington _ Proposed exterior modifications _ 2015-03-26 32 Planned restorations and rehabilitations 3 of 8: Building exterior Architectural feature Item # Feature and its condition: Work/impact on feature: Expected cost Photo #(s) Building exterior 14 Single exterior electric meter and panel mounted to east wall Replace with triple meter/interrupt stack serving interior panels; use existing penetrations; affix into masonry joints. (incl. in #14) Ex-8, 9 15 Single exterior gas meter at NW corner of property. Separate 1st/2nd floor gas service; add new exterior meter at existing location (incl. in #16) Ex-10, -13, - 14 (continues on next page) 16 Original 30" opening into basement on south side; wood casement window, treated timber window well. Basement stairwell/entry at east side appears to have been cut into original sandstone foundation wall below existing window/header. Simple wood post frame, with corrugated plastic roof, covers concrete stairs. Window over basement stair opens into planned north floor shower space; currently has deteriorated frame, single plastic pane. Reconfigure basement access to support basement finish as separate living unit. Convert south window 508 Remington _ Proposed exterior modifications _ 2015-03-26 33 Planned restorations and rehabilitations 4 of 8: General interior excluding basement finish Architectural feature Item # Description of work Expected cost Photo #(s) General interior excluding basement finish 15 Electrical • Upgrade existing single family 150A service to 3x multi-family 150A service • Replace existing panel/meter with single triple - meter/interrupt stack serving interior panels • Install interior panels within each unit; reroute wiring as required • Add additional dedicated circuits and GFI outlets • Add 220v outlets at 1st/2nd floor laundry locations • Rewire 1st floor bathrooms, replace lighting/fans • Add individual-thermostat baseboard heaters in first floor bedrooms & baths for target heating $12,300 incl. City of Fort Collins Utilities service upgrade cost 1-2, 5, 8, 31 16 HVAC • Replace corroded venting • Replace basement supply runs with low profile ducting to increase head height • Add supply to 1st floor northwest bedroom • Add return from 1st floor northeast bedroom • General tuning of duct airflow to increase efficiency • Switch supply and returns for 1st floor northwest bedroom from 2nd floor system to 1st floor system • Inspect and service furnaces $1,600 B-3, 4, 5, 6 17 Plumbing • Replace old galvanized waste lines • Replace supply lines where required • Add laundry supply and waste connections in 1st floor hall closet area and 2nd floor bath; relocate 2nd floor bathroom sink • Replumb 1st floor northeast bathroom • Remove 1st floor northeast kitchen connections • Replace gas hot water heater – 50 gal (1st floor) • Add new gas hot water heater – 40 gal (2nd floor) • Replace / reroute gas lines for separated service $7,200 B-1 1-1, 5, 6, 28, 508 Remington _ Proposed exterior modifications _ 2015-03-26 34 Planned restorations and rehabilitations 5 of 8: General interior excluding basement finish (cont.) Architectural feature Item # Description of work Expected cost Photo #(s) (cont.) General interior excluding basement finish 20 Insulation • Blow in cellulose in attics to R-38 including pony walls and coffers • Blow in cellulose in ceilings / floor joists for thermal insulation and noise reduction • Frame and insulate basement walls with open-cell foam to R-15 (framing cost incl. in basement finish) • Insulate crawl space to R-19, including pre-laid french drains, vapor barrier, perimeter insulation, and batting in joists $3,800 n/a 21 Whole house attic exhaust fan • Install whole house attic exhaust fan in (2nd floor) ceiling of front entry stairwell • Convert glass above 2nd floor entry into louvered adjustable pass-through vent • Install louvered adjustable pass-through vent at top of wall to west of 1st floor main entry $2,600 1-18 2-1 22 Fireplace / chimneys • Connect damper and service 1st floor fireplace • Reline eastern exterior chimney, add interior wood stove on eastern wall of 1st floor dining room $4,700 Ex-1, 7 1-15, 21 23 Plaster walls and ceilings • Repair cracks, holes and damage in walls/ceilings • Retexture patches to match smooth finish • Box in exposed ducting adjacent to main floor fireplace, plaster to match, match base trim $7,100 1-3, 4, 17, 22, 24B, 26 24 Paint • Repaint interior walls and ceilings where required • Repaint doors and trim where paint deteriorating $3,400 1-all 2-all 25 Flooring • Restore original wood floors on 1st floor • Carpet 2nd floor bedrooms with extra thick pad for sound reduction • Carpet stairs/landing to 2nd floor for sound 508 Remington _ Proposed exterior modifications _ 2015-03-26 35 Planned restorations and rehabilitations 6 of 8: Baths excluding basement finish Architectural feature Item # Description of work Expected cost Photo #(s) Baths excluding basement finish 26 Reconfigure and rehabilitate 1st floor northeast bathroom • Close floor void opening to basement • Lower height of east space (former stairwell) floor to same height as original construction • Frame in wall separating planned closet (north) and bath (south) areas • Relocate attic hatch to north • Fir out and insulate perimeter walls with rigid insulation • Install shower over former floor void; replace Plexiglas window with acrylic block • Install new sink and faucet in prior shower location • Replace toilet with high efficiency • Install tile shower surround and flooring • Move doorway to north to provide navigable walkway to toilet and shower; add 30" pocket door • Drop ceiling, laminate walls with moisture-damage- resistant drywall; texture to match predominate plaster and lathe smooth finish $5,900 1-5 27 Rehabilitate1st floor southeast bathroom • Replace toilet with high efficiency • Remove tub and replace with shower pan and tile surround • Install shelving in space created by tub conversion to shower • Replace sink and faucet • New tile flooring $2,900 1-31 28 Reconfigure and rehabilitate 2nd floor bathroom • Relocate sink location to accommodate laundry connections; replace sink and faucet • Replace toilet with high efficiency • Take existing shower surround framing to ceiling to accommodate laundry venting chase; install shelving and cupboards adjacent to / above laundry bay • Install tile shower surround and vinyl flooring $2,100 2-9, 10, 11 SUBTOTAL: BATHS EXCLUDING BASEMENT FINISH $10,900 3.a Packet Pg. 64 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 36 Planned restorations and rehabilitations 7 of 8: Kitchens excluding basement finish Architectural feature Item # Description of work Expected cost Photo #(s) Kitchens excluding basement finish 29 Rehabilitate first floor kitchen • Extend cabinets along north and east walls – Relocate refrigerator to west wall – Add new 36" base cabinet and wall cabinet on east wall from south edge – Add new stove bay at 45° angle at northeast corner; above stove at 45° add new 30" wall bridge cabinet above built-in microwave / range hood (with venting to exterior); add new 15" wall cabinet to west of corner – Add dishwasher bay to right of existing sink – Refurbish existing built in cabinets – Fabricate doors on new cabinets to match existing; replace / add matching pulls • Add new granite tile countertops with epoxy grout and wood edging • Replace sink, add garbage disposal • Upgrade lighting • Restored wood floors (incl. in general interior) $4,100 1-28, 29 30 Rehabilitate second floor kitchen • Remove existing floor cabinets • Add new peninsula running north from south wall – Add refrigerator bay with overhead cabinet at south wall, with top of overhead cabinet meeting bottom coffer line; provides chase for peninsula electric connections – Add electric range bay to north of refrigerator bay, separated by 6" countertop / tray bay – Add 36" base cabinet to north of range bay – Add breakfast bar on west side on peninsula – Fabricate doors on new cabinets to match existing; replace / add matching pulls • Add dishwasher bay to left of sink • Add new granite tile countertops with epoxy grout and wood edging • Replace sink, add garbage disposal • Upgrade lighting • High-durability laminate plank flooring (incl. in general interior) $2,800 2-4 SUBTOTAL: KITCHENS EXCLUDING BASEMENT FINISH $6,900 3.a Packet Pg. 65 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 508 Remington _ Proposed exterior modifications _ 2015-03-26 37 Planned restorations and rehabilitations 8 of 8: Basement finish Architectural feature Item # Description of work Expected cost Photo #(s) Basement finish 31 Remove ash pit (engineer already consulted to confirm non-load-bearing) $150 B-3, 6 32 Fir out and insulate basement perimeter walls (incl. in general interior) n/a B-all 33 Sandblast and seal existing interior (foundation) walls $800 B-2 34 Frame interior walls: full bath, laundry closet off bath, hall, bedroom closet, mechanicals (existing walls otherwise sufficient) $2,800 B-4, 7 35 Kitchen base and wall cabinets and countertops $3,700 B-8 36 Electric wiring and lighting to code $2,600 B-all 37 Electric baseboard heat and water heater $3,300 B-all 38 Bathroom fan and laundry venting through CMU foundation via crawlspace $700 39 Plumb bathroom and kitchen; run new supply lines, use existing waste lines $1,900 B-7, 8 40 Plumb laundry closet, incl. trenching floor for new direct connection to 3" waste line and repouring concrete $1,200 B-7 41 Three pre-hung doors and framing $900 n/a 42 Drywall, interior trim, and painting $6,400 B-all 43 Flooring: carpet in bedroom, tile in bathroom and laundry closet, high-durability laminate plank elsewhere $3,300 n/a SUBTOTAL: BASEMENT FINISH $27,750 3.a Packet Pg. 66 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 3.b Packet Pg. 67 Attachment: 508 Remington _ basement stairwell plans (3052 : 508 Remington Street - Conceptual and Final Design Review) 3.b Packet Pg. 68 Attachment: 508 Remington _ basement stairwell plans (3052 : 508 Remington Street - Conceptual and Final Design Review) 3.b Packet Pg. 69 Attachment: 508 Remington _ basement stairwell plans (3052 : 508 Remington Street - Conceptual and Final Design Review) 3.b Packet Pg. 70 Attachment: 508 Remington _ basement stairwell plans (3052 : 508 Remington Street - Conceptual and Final Design Review) reduction • Install new high-durability laminate plank flooring on 2nd floor common areas, including over existing glued-down materials; install over leveling & sound- reducing underlayment $5,900 1-all 2-all SUBTOTAL: GENERAL INTERIOR EXCLUDING BASEMENT FINISH $56,400 3.a Packet Pg. 63 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design 31 2-4, 10, 11, 12 18 Replace water supply line from curb stop to building to correct insufficient water pressure $7,000 n/a (continues on next page) 19 Convert 1st floor northeast corner kitchen to bedroom • Remove kitchen, incl. shelving and cabinets • Close hole in south wall, restore wainscoting $800 1-1, 4 3.a Packet Pg. 62 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design well into entry stairs and door into basement living area. Add stone stairwell with grating steps and french drain, black pipe- framed metal panel roof with muted roof panel paint. Widen opening, add 36" screen door and full- length glass fiberglass entry door. Convert east basement stairwell into egress for basement bedroom, with vinyl double-hung window and treated timber window well. Rehabilitate window above basement stair with acryllic block. $6,800 Ex-2, 3, 4A, 5 Ex-7, 8 SUBTOTAL: BUILDING EXTERIOR $16,700 3.a Packet Pg. 61 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design and basement kitchen $350 Ex-10, 11 11 1965 addition: concrete masonry unit foundation enclosing a crawl space Add vent hoods for basement laundry and bath on east face of SE CMU foundation wall $350 Ex-7 13 Single pane dormer windows at east and west gables. Convert windows to louvered shutter vents to allow use of whole-house attic exhaust fan $150 Ex-1, 7 3.a Packet Pg. 60 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design one-over-one double hung, with counterweighted sashes. Counterweights attachment lines have broken in all but a few instances. Window fit has deteriorated and sealing is generally poor. Retain original windows, restore operability • Remove interior stops, clean and deburr sashes and side jambs for smooth operation • Create access panels in side jambs to access counterweight balances. • Retain hardware wherever possible, replace where missing / damaged. • Weather seal, replace / reinstall stops $1,850 Ex-1, 9, 11, 12 1-2, 8, 13, 16, 27, (S window) 2-9, 13, 16, (W window) 3.a Packet Pg. 59 Attachment: 508 Remington _ Proposed exterior modifications _ 2015-04-07 (3052 : 508 Remington Street - Conceptual and Final Design