HomeMy WebLinkAboutBuilding Review Board - Minutes - 06/27/19960
BUILDING REVIEW BOARD
REGULAR MEETING
June 27, 1996
1:00 PM
Council Liaison: Ann Azari II Staff Liaison: Felix Lee
Chairperson: Mike Sutton 490-2161(w) 484-1849(h)
The regular meeting of the Building Review Board was held on Thursday, June 27 1996, in the
Council Chambers of the Fort Collins Municipal Building. The following members were present:
Sutton, Cornell, Hansch, Meleski, Cotterman. Board members absent: Brown, Froseth.
Staff members present: Felix Lee, Building & Zoning
Jennifer Nuckols, Building & Zoning
The meeting was called to order by Chairman Sutton.
The minutes were approved with corrections.
PRESENTATION BY LINDA DEVOCELLE FROM NATURAL RESOURCES ON
PROPOSED WOOD BURNING AND RADON ORDINANCES,
Wood Burning
Linda Devocelle of the Natural Resources Department came before the Board with a slide
presentation overview of the proposed wood burning and radon ordinances.
Linda introduced Brian Woodruff, also of the Natural Resources Department and stated that Dr.
Janet Johnson, a health physicist, from Shepard and Miller would be joining the meeting shortly
and would be able to answer some of the questions that may be raised concerning the radon
issue.
Linda went through the slides and explained the steps that are to be taken in presenting the issues
to Boards and Commissions, Chamber of Commerce and social groups, and possibly several
public meetings. It is planned to go to a council study session on July 23rd, and to go for a first
vote on August 20th.
Attached are copies of the slides used at the presentation.
Building Review Board
June 27, 1996
Page 2
Linda reviewed the Air Quality Action Plan that the City initially passed in 1994, which was
recently updated. She explained that the plan lays out a 20 year plan for air quality in Fort
Collins and that it looks at four sources of air pollution: automobiles, commerce and industry,
wood burning and indoor air pollution. "The goal of the air quality plan is to continually
improve Fort Collin's air quality", stated Linda.
Linda reviewed the proposed ordinances, why they are being proposed, the goal of the air quality
action plan, public opinions on wood burning and wood smoke pollution. She provided statistics
on the. number of wood burning fireplaces in Fort Collins as well as statistics on the number of
freestanding wood stoves and fireplace inserts. Also provided were figures on what it could cost
to remove an existing fireplace, decommission an existing fireplace, remove and remodel and/or
replace an existing wood burning fireplace with gas. She further discussed implementation of
the proposed code and how it would be carried out.
Board member Cotterman questioned who the "staff' is that has been working on the proposed
ordinance. Linda Devocelle stated that "staff' are members of the Natural Resources
Department who are in the air quality unit and Mike Gebo from Building Inspection. Cotterman
asked who is on the committee. Linda replied that Bill Ekard, Margaret Phillips, Mike Gebo and
herself are on the committee.
Sutton questioned why now we need an ordinance if we are already getting better air quality as
use of wood is presently dropping?
Linda stated that there are still approximately 15,000 wood burning fireplaces and 5,000 to
6,000 freestanding wood stoves and/or wood stove inserts which are "dirty burning" and they are
not seeing a turnover on those units.
Meleski questioned that when a person wants to sell their house and it is recognized that there is
a wood burning unit in the home, what is their next step? Linda stated that the implementation
part of the ordinance is still being worked out but the committee's suggested method of
implementation is that if a person has a wood burning unit, they would have to have an
independent parry come in and verify as to whether that unit were certified. She stated that it has
been discussed to set up training for home inspectors because many people currently have home
inspections and the inspector would then perform an inspection and contact the Building
Inspection Department and verify whether it is a certified unit.
Sutton asked if there had been any input from the real estate community?
Linda responded that they will be meeting with the Board of Realtors to discuss the situation.
Cotterman asked if there are any numbers on homes where wood burning is the sole source of
heat?
Building Review Board
June 27, 1996
Page 3
Linda replied that they had no solid statistics on that but that it is a small portion that are used
solely for heating, and that she would later provide that number for the Board.
Cotterman stated that any restrictions would impose a great hardship on low income households.
Linda agreed that it would be hardship on those who use wood burning solely for heating
because if they did not have a certified unit and wanted to continue to do such, their unit would
need to be upgraded.
Sutton stated that this can only be controlled at the point of sale and that there may be a
demographic that may not be doing a lot of buying and selling of homes. He continued that if
someone is selling their house, it will affect the buyer, not the seller. Linda agreed as to that
point but stated that there have not been any final decisions made on the ordinance.
Meleski asked if the ordinance would affect historic housing? Linda replied that they have not
looked at that, as have they not looked at multi family units.
Sutton questioned if there is any kind of estimate on where these 15,000 wood burning units are -
upper end, lower end, multi family? How many of them change hands in a particular year?
Linda replied that the real estate community has stated there to be a turnover of about 2500
homes a year.
Cotterman questioned the level of wood smoke pollution in comparison with smoke from
automobiles? Linda replied that automobiles are the major source of air pollution in Fort
Collins, followed by commerce and industry, and wood burning, third. She stated that the
committee wants to continually look at pollutant contributors. Wood smoke contributes about
10% of the carbon monoxide, auto pollution about 90%, but wood burning fits into the whole
picture of air pollution in Fort Collins. Cotterman stated that for 10% of the total, there are a lot
of restrictions being put on those 10% and we're letting the other 90% go without any major
changes in the building code. He questioned if there is another City body that is looking at
putting restrictions on the automobile user? Linda replied that the City Plan is looking at the use
of the automobile.
Linda questioned the Board on how they felt about the non permitted units? Sutton replied that
going in at the point of sale is about the only place to catch non approved units but feels that it
would be a decent approach. Stated that he agrees with Cotterman that wood smoke is the 3rd
largest cause of pollution but we are having a positive trend. He questioned if there is any way
to increase this trend without imposing another ordinance, also what is the City's role and what
kind of expense will there be on the City? Linda replied that they don't have a dollar amount on
that and that there will"be some staff time spent on training of home inspectors.
Cotterman stated that there are currently wood burning restrictions in the code and that in time
Building Review Board
June 27, 1996
Page 4
the current codes will decrease wood smoke output. He stated that he feels it is too much to ask
for new restrictions.
Brian Woodruff of the Natural Resources addressed the Board. Brian stated that the
air quality plan contains the goal to continually improve the air quality, it also has the objective
to reduce the number of uncertified wood stoves in Fort Collins, and the air quality plan directs
them to try to reduce the number of unconverted units by either decommissioning them or
upgrading them. That is what is prompting the committee to look at the ordinance approach.
They have already tried incentives and have not seen turnovers.
Sutton asked if the fuel side has ever been looked at - tax the fuel and make it more expensive?
Brian stated that they have not looked at it.
Meleski stated that he does not consider the wood burning issue a major problem and we
continue with the current program but that he does agree with the idea of taxation on the fuel
(wood).
Lee stated that from a staff perspective, in terms of impact, specifically the non permitted,
illegal units, that he supports the action to require verification for illegal units at the point of sale
because of the safety issue involved and that it would not impact staff greatly.
Sutton stated that he agreed with Lee.
Radon
Linda stated that the Air Quality Advisory Board is recommending that all new construction be
tested at the point of sale and that those test results be provided to the buyer. She explained that
Colorado is in what the EPA calls a Zone I radon area - our radon levels tend to be above
4 piC/L of air - the level at which the EPA recommends residents consider taking action. She
stated that in Fort Collins, the levels tend to be between 4 and 10 on average.
Linda continued the slide presentation, showing a city survey of radon levels on different levels
of a home. She discussed the health risks of radon and went over statistics done on miners. She
also stated that Larimer County is presently requiring radon testing and that the test is being tied
into the issuance of the Certificate of Occupancy. Linda explained the procedure and the system
used to perform the radon testing. She showed a slide of a passive system and how it works.
She further showed slides on test costs on single family, multi -family and non-residential for
passive system installation.
Linda stated that the implementation is not meant to put an additional burden on Building
Inspection. The testing would be completed prior to issuance of a certificate of occupancy by a
third party . The test results would be provided to the home buyer. In the instance of a spec
0
Building Review Board
June 27, 1996
Page 5
home, the test would be done similar to an existing home transaction and the buyer would get the
test results prior to finalizing the contract. She stated that implementation is still being worked
out.
Linda stated that staff supports testing if a valid way to test can be found and continue to have a
program that raises public awareness. She stated that they also support installation of a passive
system.
Meleski questioned whether testing would be on new or existing construction. Linda stated that
it would be on new construction. The committee is looking at new homes because they are a
good place to start. To install on existing homes would be a major expense to a lot of people.
Sutton stated that mitigation would be much more expensive in an existing home than to be
added as part of new construction. He also explained how readings may be incorrect as the test
may not be done properly because home owners are wanting to move in quickly. A passing
reading could be obtained but not be correct. He questioned what kind of testing will be done?
Linda replied that it would be a short term 48 - 72 hour test or a continuous monitor type test
which does a continuous printout, that can be done in a shorter period of time. Sutton stated that
cost shown by Linda seemed to be low for mitigation by about 10%.
Sutton questioned Dr. Johnson about the risks of radon. She replied that in uranium miners,
radon causes lung cancer and can therefore cause cancer in homes. She stated that indoor levels
of radon can increase ones chance of getting lung cancer. She also explained how testing on
radon is done under proper conditions.
Meleski stated that severe areas should be pinpointed, and the only way to do that is to require
existing houses to be tested. Dr. Johnson stated that radon levels can change on a house by
house basis. Sutton stated that generally one can say southwest part of the City is more likely to
have a problem then the northeast. Houses side by side can be completely different - if it is
going to succeed, testing needs to happen on every housing transaction.
Linda stated that the City is the process of completing a radon indoor potential mapping study,
that looks at geology and soil permeability in several locations throughout the community.
Meleski recommend everyone test their homes.
Linda stated that of all who have called her requesting information about radon or tests, none
have complained about testing being a problem. She said they are all very concerned about
radon.
Cornell stated that the City Water Utilities had a water meter installation program and maybe a
similar program could be set up for radon testing. Sutton stated that there should be a cut-off
0 •
Building Review Board
June 27, 1996
Page 6
date for the volunteer program and then the ordinance would kick -in and then people would
have to pay for the testing and installation of mitigation systems on their own.
Meleski asked about recommending implementation? Linda stated that staff recommends testing
and that they believe radon is a health problem and people should install passive systems to
impact air quality. She stated that they would like to see testing done in new homes. Meleski
asked when staff is going to decide on exactly what is to be done? Linda replied that the EPA
states we are in a Zone I radon level, and if we want to impact air quality, then why not just put
in a system up front. Sutton asked what the ordinance would say? Linda stated that they are not
through with their public outreach on the issue. In about six weeks they will be done with
public outreach and may have at that point decided to test each individual home and leave it up
to the individual to do it.
Meleski asked if Staff will come back to the Building Review Board to present their findings?
Linda stated yes.
Sutton stated that the requirement to have radon mitigation should be an individual decision, not
a legislative decision. Dr. Johnson asked if it is any different that other safety issues in a house,
ie electrical. Sutton stated yes. He continued that one cannot safeguard themselves in every
aspect of their life - there should be some sort of limit on what you are told to do, each
household is different - there should be personal responsibility in this issue.
Cornell asked if there is any data to support death by radon of non smoking people in their
homes rather than just statistics on miners. She stated that nonsmoking miners have died of
radon. Dr. Johnson stated that the National Academy of Sciences is reviewing all of the indoor
air studies.
CONSTRUCTION DEBRIS ORDINANCE
Lee explained that in the preceding months packet, was a draft of an ordinance that is a revision
to the current debris containment requirements on construction sites. He stated that there is an
increase in the number of calls complaining about construction trash. The ordinance is being
looked at to revise current language to include what kind of containers are required, and what
action can be taken if a person fails to contain their trash. He stated that there have been
meetings with neighborhoods and trash haulers and had the item tentatively on the agenda for
August but it will not be on the agenda for council in August.
Meleski asked what kind of containers will be required? Lee stated that a lot of sites are using a
sturdy wire with 6 - 8 inch openings so trash can still get though. Cornell commented on the
covering. He asked if one could separate blowable from nonblowable materials? Lee stated that
that would be one choice. A cover could be used any time construction ceased for 8 hours.
Building Review Board
June 27, 1996
Page 7
Meleski asked what will happen whenever there is a transgression? Lee stated that the Building
Department is really indirectly related to the issue. Currently the Streets Department enforces
construction debris compliance by issuing a citation. He explained that what would happen
under the proposed language, is the Building Inspection staff would have authority to write a
stop work order. Cotterman questioned what the black fabric perimeters are around a lot of the
construction sites? Lee explained that those black fabric containment walls are for erosion
control. Cotterman questioned if that fence could be worked into trash control?
Sutton stated that something needs to be prescribed but that he has a problem with telling how it
needs to be contained as long as the way it is being contained is working. If it isn't working,
then it would be okay to do something about it. Sutton questioned what would happen when a
large winds blows lumber and roofing materials around? Lee replied that that would not be
considered construction debris, but airborne damage. This issue concerns the true debris - scraps
that are left lying around - discarded, not ejected from the site.
Cornell stated that this problem has been handled by many good contractors and feels that they
delegate the responsibility to the subcontractors. He stated that whose responsibility it is has
always been an issue. Sutton stated that they are talking about additional cost to enforce the
issue, but that it wouldn't take many times for contractors to get "bit" before the word gets
around and then the problem would diminish fairly rapidly. He stated that enforcement would
come from regular inspections and complaints.
Lee reinforced that there is no connection to the Building Department at this point. All that that
department can do is call and inform the Streets Department.
Meleski stated to do what ever is necessary to take care of the problem.
There were no other comments on the issue.
OTHER BUSINESS
Harry Cornell was recognized and thanked for his eight years of service to the Building Review
Board.
The meeting was adjourned
Mike Sutton, Chairman
Felix Lee ector of ulmg & Zoning
PROPOSED ORDINANCES
Wood Smoke
Radon
AQAB Proposed Ordinances
■ Change -out all non -certified, high polluting
wood stoves and fireplaces at point of sale
(PGS)
■ Conduct a radon test in all new
constructions at POS with test results
provided to buyer
Air Oualitv Action Plan
"Continually improve Fort Collins Air
Quality
■ "Reduce area -wide wood smoke emissions"
■ "Reduce the number of non -certified wood
stoves and conventional fireplaces"
■ 'Increase percentage of residences... taking
action to reduce exposure to LAP"
NEXT STEPS
■ Presentations to Boards, Chamber, Social
Groups
■ Article in Coloradcan
■ Public meetings
■ Council Study Session - July 23
■ First Vote - August 20
WHY?
■ Radon (Rn) point of sale
— residents have a right to know risks
— may drive voluntary installation of Rn mitigation
systans
— education and awareness
■ Wood Smoke point of sale
— turnover of high -polluting units more quickly
WOOD SMOKE POLLUTION
■ Opinions about wood smoke
- 93%say about right or don't notice wood it
- 4% too much
- 4% don't know
■ Those concerned
— 14% enviromnental concerns
- 8% health/allergies
— 5% smells/looks bad
I
WOOD SMOKE POLLUTION
■ Carbon monoxide - 8-10%
- CommerceQndustry & Autos
■ PM10 - 2-3%
■ 50% less CO since 1985
- state and federal regulations
- changing attitudes
- wood FP to gas conversions
- City voluntary programs
WOOD STOVES
as Freestanding WS and Fireplace Inserts
as 5,000 in Fort Collins
- majority, older, high -polluting units
- used more often & for longer periods
- turnover is slow
- some wood to natural gas changeovers
- non-use increasing
COSTS
as Wood Stoves -Freestanding
- $150 - remove and destroy
- $0 - 200 - decommission and turn into
heirloom
- $300 - $3,000 - remove and remodel
- $975 - $3,100 - replace with certified unit
FIREPLACES
■ 14,000 Woodbuming FPs in Fort Collins
- high -polluting, no emissions controls
- changeover to gas incressing
- 2,000 - 4,000 gas logs sold annually
- new homes installing gas fireplaces
- increasing non-use
- used infrequently, mostly aesthetic
WOODBURNING UNITS
M
se
40
30
111890
90
at99a
19
H99fi
e
Man Oat
untt Danz uat
0n1
U.
COSTS CONT'D
■ Fireplaces & Wood Stove Inserts
- $750 - $2,500 - gas logs
- $1,400 - $3,000 - gas insert
- $1,500 - $3,000 - woodbuming insert
2
IMPLEMENTATION
■ Change out of all high -polluting units
— Realtor, buyer, seller
— Home inspector
— Documentation presented at closing
■ Non -permitted units
— City Building Department
STAFF
■ Still analyzing data
■ Non -permitted units
— Wood smoke pollution on the decline
— ZILCH prioritize Wood Stove turnover
— Increase use of Complaint Line
— Least "big brother" approach
— approximately 1/2 stoves non -permitted
— will increase turnover
CITY SURVEY DATA
]nd Ut 9au
Floor floor
COMMITTEE POSITION
■ Complete wood smoke survey to provide
most current data
• Improve existing programs -ZILCH, current
codes, Complaint Line, education
■ Identify non -permitted units, require they
meet current standards
■ Iarimer/Colorado - Zone 1 radon area
■ Testing - only way to determine level
■ Fort Collins - average 4 and 10 piC/L
— Year-round level may be lower
■ Radon causes lung cancer
— Accepted by leading health agencies both
public and private
Options Under Discussion
■ Testing in all new construction
■ Installation of passive radon system
■ Testing in all homes ... new and existing
stock
3
L
LARIMER COUNTY TESTING
■ Tests in all new subdivisions
■ Test results sent to county Bldg. Dept.
■.Testing tied to certificate of occupancy
■ Some voluntary installation of radon
systems occurring
■ Installation of radon systems in three
subdivisions
IMPLEMENTATION OPTION
is Testing
- Builder apprises buyer prior to construction
u Buyer makes decision about an system up front
- Builder arranges for Rn test prior to CO
- Test results provided to buyer
- Spec home
n Buyer gets test results prior to finalizing contract
u Buyer can request mitigation
COMMITTEE POSITION
is Radon is a health risk
■ Favor testing and education
is Some support for installation of passive Rn
system
is Testing may drive voluntary installation of
systems
■ Focus on single family homes first
COSTS
■ Testing
- $I00-S200
Single Family
- $100 X number of units
Multi Family
- Sl00-$500
Non -Residential
■ Passive Radon System
- S400-S800
W/Basement
- $40041,000
Basement/Crawl
- $300-S400
To activate (fen)
IMPLEMENTATION CONT'D
■ Installation of Rn system
- Full passive system capable of activation
- Test conducted by buyer after taking
possession of property or, test provided by
builder prior to CO
- Test results provided to City within 60 days
following occupancy
- Penalty for not complying
POSITION CONTINUED...
is Need better quality control among testers,
labs and mitigators
- Currently no registered or certified Rn
providers
is Existing housing stock
- Do not adopt mandatory program
- Continue to work with real estate community
- Focus on education and voluntary testing
Ell
STAFF
as Support testing
— Develop valid testing & reporting procedure
— Minimal impact on building department
— Raise awareness.
— Maintains personal choice.
■ Support installation of full Passive System
— USEPA guidelines adopted into Code - 1999
— Allow time for builders to become competent
Building Review Board
April 26, 1996
Page 4
Cotterman told him to come back with a solid application and proof he had taken the C-2 test.
Kulenski withdrew his application.
Other Business
Meleski discussed the Model Energy Code. He said it was Alot good. He told the Board about a
house tested and the values Doug Schwartz gave the Board
t�fi�F-1-9$i�kiandboolr and sairl.iha c1n a 1�QQ�R N,�me t thv P , lA t,r an additional eSnn
d
adjaGent
Lee had stated in earlier. pmsen"efts the FspaF hanier would quixed to d 't i at
d. Lee
responded that the specific details were not yet resolved and would be clarified before
implementation.
Six Month Calendar
Lee addressed the Six Month Calendar for City Council and said the calendars will be included in
their packets on a regular basis.
Minutes
Cotterman asked that the minutes be more detailed. Others agreed.
The meeting was adjourned.
Fo R— r
w�E12Co � SAJI JCS WtIEJ -b ASangE �r c,�Al-(-I A23=
'./aAbb�7-,o.J�_I✓c
� MR. �EC£SKl v)A..tT�� 1T' as -r4l- I.�Go2D 1 t A`r KAR
LEH 1-�AD STA"�E-b To BARiZ1ER
T6 $�-
\\ N
To7-Ac_.t.l� 5>=A�E� I+J o�D+c-� To ME�=i- A cat= t cR-Nl
\I APo� ,�JARRIER- �AT�'J�• EL�SKI `�TAT'eb TtkAT
Tt{E Jz>a a� 45n)L-`1 ICE QJtR�S -r IAT 1 F-
So rJ TS �� �..A�P>=b 1eJ o�-•DE12- To �E�s.T 74tS--FA-r,��. I
SCot,.,ce caF -Sv,.,-r••5 LS }"7\EQvt12-gip tT' W,c..C.- AAr> A-.) ADv�T,a.JAc,
Soo (nn , a . + nn� To Tr� E G=ST of A lll. 111
Building Review Board
April 26, 1996
Page 3
Board member Froseth moved to approve Means for a Class D license and certificate if he supplied
the Board and/or Lee a copy of his transcripts or diploma with proof of his construction management
classes. Board member Cornell seconded the vote.
Discussion:
Meleski said he felt Means was capable, but he needed more completed projects.
Sutton said letters from contractors may have helped his case. Sutton added Means professionalism
showed promise.
Call for the Vote
Yeas: Froseth, Cornell
The motion failed.
Al Kulenski, Class C-2
r'(DnbJ .
Nays: Meleski, Brown, Umseh; Cotterman
Lee reviewed his file. Kulenski has been licensed with the City of Fort Collins, Class D, since 1983.
The information the Board received was the original information from 1983 along with a current
resume. Lee said with the project verifications he had, do not meet the criteria for a Class C-2
license.
Kulenski appeared before the Board. He said he came to the Board to explain why he needed a C-2
license. He reviewed his background. He said he worked for Everett Companies for eight years and
Storck Development seven years. He said Mr. Storck is getting out of the business and34uleaeki 4
He said he has closed over 300 homes, and currently is doing 160 patio homes at
the Village at Southridge. Kulenski said the company is getting ready to do 4-plexes and 6-piexes
and that was the reason he needed a C-2 license.
Meleski stated Kulenski had no multi -family references.
Kulenski said he would like to get additional references and appear before the Board at a later date.
He added 36 patio homes he closed in 1994 had 0 lot lines and were similar to multi -family units.
He told the Board he would take the test and get additional references.
NAD �oLD 1j t5 OPERA'r'low� MAP -le- TZoA14 _� OA ES /✓jR .
• WIL(�
ti15K.1 3F_ TILE GEJE!?_AL_ 'F'tEC.D
1
to
11
SIX MONTH PLANNING CALENDAR
June - December 1996
MEETING
MEETING
AGENDA ITEMS
DATE
TYPE
June 25
Study
Budget
Electric Utility Governance
June 27
Thurs.
Joint City/County Meeting (City Hosts - CIC) 5:30 p.m.
July 2
Regular
New Bridges Additional Funding
Add Cap Expan Fees - Affordable Housing Rebate Program
City Plan - Structure Plan
- Master Street Plan Adoption
- Street Width Standards
July 9
Adjourned
Interim Evaluations City Mgr, City Atty, Municipal Judge
July 16
Regular
Neighborhood Parkland Fees
Fort Fund Disbursements
Street Oversizing Fees
CDC Appropriation Ord & Contract for Services
Civic Center Master Plan
July 18
Thursday
Regional Cities Elected Officials 6:00 p.m. (Location
TBA)
July 23
Study
CIP Update
Wood Smoke and Radon
City Plan - Principles and Policies
July 30
Fifth Tuesday
NO MEETING SCHEDULED
August 6
Regular
August 13
Study
City Plan - Implementation
August 20
Regular
Wood Smoke and Radon
City Plan - Principles and Policies
August 27
Study
CIP Update
Natural Area Plan Implementation
September 3
Regular
Redistricting for 1997 Election
Adoption of Mail Ballot Plan
Set Budget Hearings
September 10
Study
Budget
September 17
Regular
Parks and Rec Policy Plan
Public Hearing on 1997 Budget
September 24
Study
Budget
CIP Update
City Plan - Comprehensive Plan
September 26
Thursday
Joint City/County Meeting (5:30 p.m., County Hosts)
October 1
Regular
Public Hearing on 1997 Budget
and Environmental Services 0le�cmd~
Natural Resources Department
DATE: June 18,1996
TO: Building Review Board
FROM: Linda Devocelle, Environmental Education Specialist, NRoa,__
SUBJECT: Wood Smoke and Radon Ordinances - Summary
BRIEF DESCRIMON OF ISSUE:
The Air Quality Advisory Board has proposed two new air quality ordinances, one requires
change -out or upgrade of high polluting wood stoves and fireplaces at point of sale, the other
requires radon testing in all new constructions at point of sale. This update provides a status
report on development of the ordinances. Ultimately, we will bring the ordinances to City
Council for a vote. We have scheduled a Council Study Session for July 23 and a first vote on
August 20. We would appreciate your thoughts and comments regarding these issues, and if you
see fit, a recommendation to City Council. Staff has not formulated a position on either
ordinance yet, but will do so prior to the July 23 Study Session. We are just beginning our public
outreach efforts.
DETAILED DESCRIPTION OF ISSUE:
Two committee have met regularly since February to assist with development of the ordinances.
In researching and developing the ordinances, several important issues have arisen. A summary
follows. For complete details, refer attachments.
Wood Smoke Ordinance
AQAB Proposal...
Adopt an ordinance requiring that fireplaces and wood stoves be upgraded to
low polluting units at point of sale.
Issues: Although the AQAB is recommending change -out of both wood stoves and fireplaces at
point of sale, the preliminary findings of the committees do not totally support this proposal.
Data from 1990, 1994 and 1996 woodburning surveys show a consistent downward trend in
wood smoke pollution. In 1994, 90% of residents surveyed said that wood smoke in their
neighborhoods was about right or they didn't notice it. Results from the current 1996 survey
show that 93% of residents are not bothered by wood smoke.
We also know that overall wood smoke pollution has decreased by 50% since 1985 due to
fireplace conversions to gas, non-use of woodburning units, state and local laws, changing
attitudes about woodburning, and an aggressive local program including education, ZILCH (the
281 N. College Ave. • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6600 • FAX (970) 221-6378
City's zero interest loan program for wood -to -gas fireplace conversions and upgrading or
dismantling of non -certified wood stoves), and a wood smoke complaint line. We dd know from
current and past surveys that non-use of wood stoves and fireplaces is on the increase, and that a
small number of homeowners are choosing gas -heating stoves to replace old wood stoves
In looking at data from our wood smoke complaint record, wood smoke pollution is primarily a
localized (neighborhood) problem, and over 95% of the complaints relate to wood stoves. There
are an estimated 2,000 to 4,000 gas logs sold in Fort Collins each year, and most new homes are
installing gas fireplaces. Wood stove turnover, on the other hand, is slow.
Finally, the woodburning ordinance may hit homeowners hardest at the low end of the income
scale because low income homeowners may own the majority of high -polluting wood stoves
and/or conventional fireplaces.
Summary of Current Committee Position
In general, the committee agrees that in order to develop a wood smoke ordinance, it is necessary
to have good data regarding wood smoke emissions. We have just completed a wood smoke
survey and will have the results available for your meeting. It is important to know numbers
and types of high -polluting units and how quickly, or slowly, they are being changed to low -
polluting units. It is also important to take a look at existing programs--ZILCK the wood smoke
complaint line, education, and state and local laws, to determine if they can be enhanced to
achieve better results that might in turn make an ordinance less urgent. In lieu of focusing on all
wood stoves and/or fireplaces at point of sale, the City might instead focus on non -permitted
wood stoves and conventional fireplaces. Currently, when the City finds a non -permitted
woodburning unit, it is inspected for proper installation and to determine if it is certified and/or
meets current state and local laws. If the unit meets state and local laws, but is not properly
installed, the owner must fix the installation problem before a permit can be issued. If the unit is
properly installed, but does not meet state and local laws regarding woodburning appliances, the
City asks the owner not to use the unit. The City could strengthen this part of code by tgquirine
that non -permitted units be dismantled or upgraded to meet state and local standards at point of
sale.
Radon Ordinance
Ordinance proposed by AQAB ...
Adopt an ordinance to require testing of all new constructions at point of sale,
with test results provided to the buyer.
Issues
The only way to determine your radon level is to test. Once you have tested, you can fix the
problem. Testing alone will not improve air quality nor guarantee that homeowners will fix a
radon problem where it exists. Although the County currently requires testing of homes in all
new subdivisions prior to certificate of occupancy, test results are often invalid because they are
not done under proper, closed -house conditions, and not all testers are properly qualified (trained)
to test.
•
USEPA has identified Larimer County a Zone 1 radon area, which means levels tend to be above
the USEPA action level of 4 picocuries per liter of air (pCi/L). The City has been working with
the real estate community for the past year to increase testing at point of sale and has worked
directly with private citizens to increase testing in existing homes. Data from private radon
testers and a City of Fort Collins radon survey indicate that basement levels in Fort Collins
residences, conducted under closed -house conditions, average between 4 and 10 pCi/L. The
average, year-round concentration to which most people are exposed under normal living
conditions is lower.
Most major health organizations, the USEPA, the Colorado Department of Public Health and
Environment, and the Larimer County Health Department agree radon causes thousands of
preventable lung cancer deaths each year and that radon is the second leading cause of lung
cancer next to smoking. Larimer County currently requires testing in all new subdivisions in the
County and installation of radon mitigation systems in three subdivisions along the foothills due to
reports by the State Geologist predicting high radon levels in those areas. No other Front Range
communities have requirements or ordinances regarding radon.
Current Committee Position
In general, the committee agrees that radon is a health risk, and most favor the Board's
recommendation, but believes the best line of attack is education. There is some support for
mandatory installation of passive radon mitigation systems, which directly affects air quality in
new homes and eliminates the difficulty of obtaining an accurate test prior to issuance of
certificate of occupancy.
Some committee members believe that testing in new homes MdU cause the building community to
voluntarily install radon mitigation systems. This seems to be happening to some small degree in
the County. The committee also believes we should focus on single family residences to begin
with and eventually look at multi -family (apartments, condos, duplexes, etc.)and non-residential
new construction later.
In dealing with existing housing stock, the committee generally feels education is the best
approach. There is limited support for requirine that radon information be provided to
homeowners at point of sale, however, it is expected that at some point the Colorado Real Estate
Commission will add a paragraph to the buyer's contract calling out radon and recommending
testing. It is unclear when this might happen. The action has the potential to raise the radon issue
to a new level of importance and might, over time, adequately address existing stock.
The committee would like to see better quality control among testers, labs, and mitigators. There
is currently no licensing or certification for those businesses providing radon services.
SUMMARY
Overview of issues
-vPhase One of the process is ongoing and includes formation of a committee to discuss and
examine various options and issues surrounding the ordinances.
4Phase Two, underway, entails extensive public outreach to city boards and commissions, the
realty, home inspection and building communities, interested businesses and organizations, and
the general public. All comments and suggestions from Phase Two will be taken into
consideration before making a recommendation to Council.
-OPhase Three is a presentation at a Council Study Session (scheduled for July 23).
-0Phase Four will be a Council vote (scheduled for August 20).
Committee Members
Margaret Phillips --Member, NE Neighborhood Association, Mike Gebo--City Building
Department, Bill Eckert--AQAB/Friendly Fire, and Linda Devocelle--Staff. NOTE: We invited
members of the real estate community and private citizens to participate on the committee. We
received response from only two private citizens and no responses from the real estate
community. We believe public outreach outlined in Phase Two will address this missing link on
our committee.
Ongoing Outreach
Throughout Phase One of the project, we sent minutes of meetings to the presidents of 31
neighborhood associations, and to all major fireplace and wood stove retailers. We also provided
information about development of the ordinances to some 900 members of the real estate
community including realtors, title and mortgage companies, home inspectors, and radon testers.
An article regarding the ordinance appeared in the winter edition of Environmental News, which
is mailed to 3,000 + groups and individuals.
Findings
In discussing the ordinances, the committees addressed a number of issues. These were
developed into "findings" —known and unknown facts relating directly to the issue of woodburning
pollution in Fort Collins. Following is a summary of those findings.
Wood Smoke Data: From 1990 and 1994 surveys, we estimate there are approximately
20,000 woodburning devices in Fort Collins--15,000 fireplaces and 5,000 wood stoves.
Woodbuming contributes 8% to 10% of our winter carbon monoxide pollution (Denver data),
and according to a 1994 LaPorte air quality study, woodburning is responsible for 2.4% of our
PM10. Wood smoke pollution also contributes to visibility degradation, which is caused mostly
by PM 2.5. Wood stoves produce approximately 50% more pollution per stick of wood than do
fireplaces mainly because of design, i.e., closed doors, which produce an oxygen -starved
environment and thus, a less -effective combustion process.
We also know that wood smoke pollution has decreased by 50% since 1985 due to fireplace
conversions to gas, non-use of woodburning units, state and local laws, changing attitudes about
woodburning, and an aggressive local program including education, ZILCH (the City's zero
4
•
interest loan program for wood -to -gas fireplace conversions and upgrading or dismantling of non -
certified wood stoves), and a wood smoke complaint line..
Fireplace and Wood Stoves: Most fireplaces in Fort Collins are conventional masonry
and zero clearance units, which carry no certification, and fireplace inserts. Since 1991, fireplace
inserts have had to meet the strictest wood stove (USEPA Phase II) standards, unless they have
been declared exempt. Most wood stoves are woodburning units, although there is a recent
upswing in interest in gas -heating stoves. Currently, only those woodburning units that meet state
and local standards can be sold and used in the AIR Program Area, which includes Fort Collins.
We do not have good local data on the actual breakdown of different types of woodburning units,
i.e., conventional fireplace versus inserts, certified versus non -certified wood stoves. Therefore,
we depend on Denver data for current wood smoke emissions projections. We conducted a
woodburning survey the week of May 28 - June 5; preliminary results will be available by the last
week in June. The survey will allow us to identify numbers and types of units, certified and non -
certified units, fuel use, frequency of use, turnover of high -polluting units, and use and non-use
of units. We will also have data on attitudes/experiences regarding wood smoke in individual
neighborhoods. In 1994, 90% of residents surveyed said the wood smoke in their neighborhoods
was about right or they didn't notice it. In 1996, 93% were not bothered by wood smoke.
Fireplace and Wood Stove turnover and trends: There are an estimated 2,000 to
4,000 gas logs sold in Fort Collins each year, and most new homes are installing gas fireplaces.
Wood stove turnover, on the other hand, is slow, and we do not have good data on actual sales.
The May survey will provide better numbers on wood stove turnover. We do know from
previous surveys that non-use of wood stoves and fireplaces is on the increase, and that some
homeowners are choosing gas -heating stoves to replace old wood stoves.
NOTE: While non-use positively affects air quality in the short-term, it is not a permanent
solution to wood smoke pollution. A future owner may choose to use the appliance.
Options
The Committee looked at seven ordinance options including that proposed by the Board. Please
refer to the attached charts.
Implementation of a point of sale (POS) ordinance
The committee continues to discuss implementation strategies. It is anticipated that responsibility
for seeing that the ordinance is carried out will be with the realtor, seller and buyer.
RADON ORDINANCE
Committee Members
Mike Gebo--City Building Department, Phil Keamey--CSU Physics professor/radon tester/lab,
Bill Alexander --Colorado Radon Engineering, Bob Huff --Colorado Radon Control, Jan Johnson --
Health Physicist, Al Kadera and Brice Ntiller--Larimer County Building Department, Barb
Blankenship --Wheeler Realty, Dick Sherman --American Connection (realtor), Jim Evenson—
private realtor, Linda Martin--CDPHE Radiation Control Division, Gil Paben—Aspen
Construction (represents the Home Builders Association), Bill Warren, National Inspection
Services, Eric Levine—AQAB, and Linda Devocelle—staff. ,
Ongoing Outreach
Some 900 members of the real estate community have been given information about the ordinance
(as mentioned above). In addition, minutes of meetings are sent to some 20 additional groups and
individuals and an article appeared in the winter edition ofEnWronmental News.
Findings
The following findings are the result in-depth discussion regarding radon levels and risks and
qualified testers, labs, and mitigators.
Radon levels and risks: USEPA has identified Larimer County a Zone 1 radon area,
which means levels tend to be above the USEPA action level of 4 picocuries per liter of air
(pCUL). Within the scientific community, it is agreed that any level of radon has some health risk.
Lung cancer risk from radon is based on cumulative, lifetime exposure level. USEPA
recommends action at or above 4 pCi/L; some scientific bodies recommend action at levels
somewhat above 4 pCi/L. Current radon mitigation techniques can reduce radon levels below 2
pCi/L. Within Fort Collins, data from private radon testers and a City of Fort Collins radon
survey indicate that basement levels, conducted under closed -house conditions, average between
4 and 10 pCi/L. The average, year-round concentration to which most people are exposed under
normal living conditions is lower.
The proof that radon causes lung cancer is taken from evidence of an increased risk of lung
cancer in miners exposed to at least 20 pCi/L over a period of years. The Colorado Department
of Public Health and Environment estimates that 50,000 homes in Colorado exceed the 20 pCi/L
level and that approximately 666,000 have levels between 4 and 20 pCi/L. The only way to know
your level is to test.
Major health organizations agree with the premise that radon causes thousands of preventable
lung cancer deaths each year. USEPA estimates the number to be between 7,000 and 30,000,
with an average of 14,000. USEPA says that at 4 pCi/L, non-smokers have a 2 in 1,000 chance
of contracting lung cancer; smokers have a 29 in 1,000 chance. Action at superfund sites is taken
when risk is one in 1 million. USEPA and several major health organizations agree that radon is
the second leading cause of lung cancer next to smoking.
Larimer County accepts USEPA guidelines, considers radon a legitimate health risk, and
currently requires radon testing in all new subdivisions. They also require installation of radon
mitigation systems in three subdivisions along the foothills due to reports by the State Geologist
predicting high radon levels in those areas. No other Front Range communities have requirements
or ordinances regarding radon. (NOTE: The City is completing an Indoor Radon Potential
Mapping Study of the Urban Growth Area. This study will help identify areas in Fort Collins
with potential for high radon readings based on geologic setting and soil permeability.)
The Colorado Department of Public Health and Environment Radiation Control Division
supports testing and mitigation and accepts the USEPA guidelines.
Labs, testers, and mitigators: There are no licensed or certified radon professionals in
Colorado, or most other states. USEPA provides training and testing for labs, testers, and
mitigation contractors. Once they have passed the test and paid an annual fee, they are fisted with
USEPA. The state and City recommend USEPA listed professionals. The committee believes
there are very few untrained labs and mitigators in Fort Collins, however, this may not be true
regarding testers. This is because many home inspectors now offer radon testing as a part of their
service. It is unclear as to the level of expertise among these individuals. It is generally agreed
that most mitigation contractors follow protocols and install good radon mitigation systems,
however, we have no hard facts to support this belief.
The local chapter of the American Association of Radon Scientists and Technicians (AARST) is
looking at the possibility of setting up a program to "accredit" those who provide radon services.
AARST is currently working with the CDPB E Radiation Control Division. If the City were to
require installation of passive radon mitigation systems, they would establish criteria for testers,
labs, and mitigators. They would also adopt the USEPA model radon mitigation code into City
Code.
Options: Please refer to the attached charts.
Implementation
The committee is in the process of discussing implementation. If we require testing, the
committee recommends it be done as in the County at the time the certificate of occupancy is
issued. If we require installation of radon mitigation systems, the City would adopt the USEPA
model radon mitigation code into the City Building Code. This would not occur until the next
regular review of the Code.
7
Options for Wood Smoke Ordinance(s)
n-04. I.
A'IR ........... ........ .... .. .
WN, MOST
........
.. ...
IN.
. . . . . . . ...
11-10
..... ......... M
Positive, but need
1. Point of sale -
Remove &Destroy 4150 Sellers, buyers, and members of
wood stoves
real estate community
better data on #s of
Decommission, and turn unit
wood stoves and
into flower pot, etc.
estimate of turnover
$04200 (Unit could still be (Estimated 5,000 wood stoves in
ffiru real estate sales
put into service by future Fort Collins. UK how many are
to determine
owners) dirty -burning units)
magnitude of impact
Remove w/complete remodel
$30043,000
Replace w/certified wood
stove
$875-$3130
2. Point of sale -
Gas logs
Same as #1
Same as #1
fireplaces
$750 - $2,500
(Gas logs could later be
(estimated 15,000 fireplaces in
removed and the fireplace
Fort Collins. UK how many are
turned back to woodburning)
Gas insert
dirty -burning units)
$1,400 - $3,000
WS insert
$1,500 - $3,000
3. Do Nothing
$0
AQ Advisory Board, some Council
Current downward
members, residents bothered by
trend in wood smoke
wood smoke or who support
pollution may or may
woodburning bans, and retailers
not continue with
existing programs &
ordinances. Result
4. Restructure
$10.000 - $30,000
Fireplace owners
Positive, but limited
ZILCH
due to funds
Target wood stoves.
Ask for Additional
Funds.
5. Sales tax incentive
Unknown
City - loss of revenue
Positive, directly
related to number of
units permitted
11
0
M -4:
6. Amnesty Program
Unknown
City, fireplace owners
Positive, directly
- pay for dismantling
Related to amount of money
related to number of
of wood stoves and
allotted for each unit and
units collected
delivering to
number of units
recycling center
7. Permit Fees
Unknown
City, residents who do not own
Low impact, since
woodburning appliances
permit fees are
already low - $15
8. Clarify/upgrade
Unknown
Retailers, by placing more
Positive, but
woodburning ords
restriction on what they can
probably small, since
install/sell
spirit of ordinance is
usually followed
9. Increase use of
May take more staff time
Building department, may require
Positive in dealing
Complaint Line
more inspections
with localized
pollution in
neighborhoods, but
related to numbers of
calls and type of
response, i.e., change
in woodburning
habits vs upgrade or
dismantling of unit
10. Provide proof of
Same as #1 & #2
Owners of woodburning
Need data stated in
permit for
appliances that are not permitted,
#I to determine AQ
woodburning units at
This option will impact fewer
real estate community, sellers.
impact of this option
POS.
people than # I and #2, but
Require upgrade or
has the potential to reach a
City Building
dismantling of non-
large number of wood stoves.
Inspection estimates
permitted units that
that 50% of the
do not meet at least
wood stoves in Fort
the minimum
Collins are non -
certification
permitted. It is
possible there are
also non -permitted
fireplaces
Options for Radon Ordinance(s)
'.,,.,-MM.XIZM.V'IMffiC Y..11..M
V
1. Test in all new
Single/F
1. Bldg. Dept - More work
-No direct benefit
constructions and
$1004200
tracking
-Education tool
provide information to
2. Builders - Added cost to
-Could lead to voluntary
buyer at POS
Multi:Fem
buyer. Timing, could extend
installation by builders
$100 X Num Units
closing on house.
and/or more requests from
I Buyer - Added cost, possible
buyers for installation of Rn
Non -Residential Bldg&
delay of project,
ready systems during
$1004500
construction.
Depends on size and
configuration of interior
of building.
'2. Roughed -in system
-Slightly less than #3
1. Bldg. Dept Slight amount of
No direct air quality benefit
in all new
-This system would not
time added when inspecting
unless system was
constructions &
include a fan.
plumbing.
completed to become either
testing.
-Testing - Same as #1.
2. Builders - Added cost to
passive or active (with fan)
(Stub pipe a few feet
buyer. Possible delays due to
above floor with ability
testing.
to extend out side wall
3. Buyer - Additional cosL
or up thru interior of
Possible delay due to testing.
house thru roof)
3. Full passive system
Basement Onlv
1. Bldg. Dept
Positive affect
w/ability to activate
$400-$800
2. Builders
(fan) & testing.
Base & Crawl Space
3. Buyers
$400 - $1,000
(Residences/per unit)
To activate (fW in
For reasons listed in #2
either or both
above
$300-$400
U. Test& inform.
rat
1. Realtors -Additional staff
Same as #1
$1004200
time, possible lost sales or
Possible mitigation
stalled sales
Passive, $800 - $1,800
2. Sellers - added cost of test
With fan, $1, 100
and possible mitigation.
$2,200
Literature - 1,5004r
5. Test & Fix
Same as #4
Same as #4
Positive affect
10
0
0
M U
7:
............
n
10N.'XIN M��
No =1
WOMEN
'The committee felt this option would be marginally effective. Several such systems now installed in Fort
Collins are not properly placed and it is often impossible to determine if the right materials have been used. As a
result, a mitigation contractor is called in to complete the system, he often has to start all over. Not only is it
important to place the pipe properly to successfully draw the radon from under the home and vent it properly to
the outside, but, there are aesthetic (visual) issues to consider also.
'Italics refer to existing homes, numbers 4 and 5.
'Redlined refers to existing homes, number 6.
11