HomeMy WebLinkAbout05/08/2025 - Land Use Review Commission - AGENDA - Regular MeetingLAND USE REVIEW COMMISSION
REGULAR MEETING City Council Chambers – 300 Laporte Ave, Fort Collins, CO 80521
5/8/25 – LURC SUMMARY AGENDA 1
1. CALL TO ORDER
2. ROLL CALL
3. APPROVAL OF MINUTES
Approval of April 10, 2025, Minutes.
4. PUBLIC PARTICIPATION
Public Participation for items not included in the agenda.
5. VARIANCE REQUESTS
a. APPEAL ZBA250008 - WITHDRAWN
Address: 1616 S Whitcomb St
Owner: Israel Broner
Petitioner: Todd Young, Architect
Zoning District: R-L
Code Section: 2.1.4
Project Description:
This is a request to exceed the maximum allowable floor area for a 2,689 square foot
proposed detached house. The total allowable floor area for the site is 2,387 square
feet. The actual floor area for the proposed house is 2,200 square feet, of which 489
square feet of the floor area features ceiling height above 14 feet. Because such
area is counted towards the total floor area at 200%, the request is to therefore
exceed the maximum allowable floor area by 302 square feet.
Additional items are included on Page 2 of the Agenda.
Participation in the Land Use Review Commission Meeting on Thursday, May 8, will only
be available IN PERSON in accordance with Section 2-73 of the Municipal Code.
The meeting will begin at 8:30am in City Council Chambers, 300 Laporte Avenue
Documents to Share: If residents wish to share a document or presentation, City Staff needs
to receive those materials via email by 24 hours before the meeting. Please email any
documents to nbeals@fcgov.com.
Individuals uncomfortable with public participation are encouraged to participate by emailing
general public comments 24 hours prior to the meeting to nbeals@fcgov.com
the Commission receives your comments. If you have specific comments on any of the
discussion items scheduled, please make that clear in the subject line of the email and send 24
hours prior to the meeting.
If you need assistance during the meeting, please email kkatsimpalis@fcgov.com.
LAND USE REVIEW COMMISSION
REGULAR MEETING City Council Chambers – 300 Laporte Ave, Fort Collins, CO 80521
5/8/25 – LURC SUMMARY AGENDA 2
b. APPEAL ZBA250009
Address: 519 W Mountain Ave
Owner/Petitioner: Christopher and Ellen Kelly
Zoning District: OT-B
Code Section: 2.1.6
Project Description:
This is a request to increase the finished square footage in an existing detached
house from 2,593 square feet to 2,826 square feet by enclosing an existing 234
square foot porch. The maximum allowable floor area in the OT-B Zone District is
2,400 square feet.
c. APPEAL ZBA2500010
Address: 2000 Mathews St
Owner: Poudre Fire Authority
Petitioner: Marie Hashaw, DaVinci Sign Systems, Inc.
Zoning District: R-L
Code Section: 5.16.2 (B)
Project Description:
This is a variance request to allow for a 5-foot-tall wall sign. The maximum allowable
height for a wall sign in the Residential Sign District is 1.5 feet. The request is to
therefore exceed the maximum allowable height for a wall sign by 3.5 feet.
d. APPEAL ZBA2500011
Address: 1300 E Laurel St
Owner/Petitioner: Corey Neuroth
Zoning District: CCR
Code Section: 3.1.7, 3.1.8, 3.1.9
Project Description:
There are two requests associated with this variance:
1. A request for a proposed 2,400 square foot detached accessory building (garage)
to replace four existing detached accessory structures. The maximum allowable
square footage for a detached accessory building for this lot is 800 square feet.
2. A request for a proposed addition (attached garage w/habitable space above) to
encroach 9 feet into the required front setback at its closest point to the property line.
The minimum required front setback for this property in the CCR zone district is 15
feet.
6. OTHER BUSINESS
-Election of Chair and Vice-Chair
7. ADJOURNMENT
4/10/25 – LURC MINUTES – DRAFT 1
Land Use Review Commission
REGULAR MEETING
Thursday, April 10, 2025 – 8:30 AM
City Council Chambers, City Hall – 300 Laporte Ave, Fort Collins, CO 80521
1. CALL TO ORDER: 8:30 AM
2. ROLL CALL
Board Members Present – Gupta, Vogel, Lawton, San Filippo, Floyd, Coffman
Board Members Absent – Carron
Staff Members Present – Noah Beals, Kory Katsimpalis, Brad Yatabe
Guest(s) – NONE
3. APPROVAL OF MINUTES
San Filippo made a motion, seconded by Coffman, to approve the March 13, 2025, Minutes as
written. The motion passed by all members present.
4. PUBLIC PARTICIPATION
-NONE-
5. VARIANCE REQUESTS
a. APPEAL ZBA250005
Address: 227 S Sherwood St
Owner: Mary E Daniel / James A Kelly
Petitioner: Jenny Murphy, J. Reiko Design + Co
Zoning District: OT-B
Code Section: 2.1.6
Project Description:
This is a request for a proposed 613 square foot residential addition to extend 8.5 inches into the
required 5-foot side setback. The south wall of the proposed addition will align with a portion of the
existing south wall of the house that is currently 4 feet 3 inches from the property line. The minimum
required interior side setback in the OT-B Zone District is 5 feet.
Staff Presentation:
Beals presented slides relevant to the appeal and discussed the variance request, noting that the property is
located near the corner of W Olive St and S Sherwood St. The request is to build an addition to the rear of the
existing structure. Beals presented plans representing existing conditions that include a deck at the rear of the
primary structure, and plans describing the proposed addition that would occur in the location of the deck.
The existing structure is already encroaching into the side setback by less than a foot, and the proposed
addition would align with the existing structure. The proposed addition would be one story in height and would
be similar in height to the existing structure. There is a second story on a small portion of the existing structure.
Beals presented side-view elevations of the proposed addition, noting the wall of the proposed addition that
would match the encroachment of the existing structure. The small second story portion is attic/storage space.
4/10/25 – LURC MINUTES – DRAFT 2
Vice-Chair Lawton clarified that the variance request only concerns the setback encroachment of the side wall
and does not include any increase in square footage. Beals confirmed all other elements comply with code.
Applicant Presentation:
Applicant Mary E Daniel, owner, 227 S Sherwood St, and Applicant representative Jenny Murphy, J. Reiko
Design + Co, addressed the Commission and offered comment. Murphy stated it is important to point out that
existing access to the basement level occurs along the wall that is in question, and if the variance was not
granted access to the basement would have to be abandoned and/or gained from the exterior of the residence.
The intent with the proposed plan is to match the existing design as much as possible.
Daniel noted a letter of support that was received from their neighbor, who is in full support of the variance.
This letter was provided to Commission members for consideration.
Public Comment:
-NONE-
Commission Discussion:
Vice-Chair Lawton sees no problem with the variance application, noting it is a continuation of existing
conditions. Lawton was unaware of the basement access and appreciated it being called out.
Commission member Coffman sees the variance as nominal and inconsequential, noting emergency access to
the lot is achievable from the north side of the lot and from the alley. Coffman is in support of the variance.
Commission member Vogel is in support of the variance, noting support offered by neighbors.
Commission member San Filippo believes the addition is well thought out and designed. San Filippo reported
that he had visited the site and feels that it is in keeping with surrounding properties along S Sherwood St. He
is in support of the variance request.
Commission member Coffman made a motion, seconded by member Vogel to APPROVE ZBA250005,
granting the requested variance to Land Use Code Section 2.1.6 to allow the proposed addition to
extend 8.5 inches into the required 5-foot side setback as shown in the hearing materials.
The Commission finds that the variance would not be detrimental to the public good; and the variance
will not diverge from Section 2.1.6 except in a nominal and inconsequential way when considered in
the context of the neighborhood and will continue to advance the purposes of the Land Use Code
contained in Section 1.2.2 because: the encroachment is less than 1 foot; the proposed addition aligns
with the existing structure; the proposed addition is one story; and the abutting property to the south
is separated by a 6-foot-tall fence.
This decision is based upon the agenda materials, information presented during this hearing, and
Commission discussion. The Commission hereby adopts the information, analysis, findings and
conclusions regarding this variance contained in the hearing staff report
Yeas: Gupta, Vogel, Lawton, San Filippo, Floyd, Coffman
Nays:
Absent: Carron
4/10/25 – LURC MINUTES – DRAFT 3
b. APPEAL ZBA250006
Address: 321 W Mulberry St
Owner: SJY Community Investments, LLC
Petitioner: Aswad Allen
Zoning District: OT-C
Code Section: 2.1.6
Project Description:
This is a request for a proposed 288 square foot accessory building (shed) to be placed approximately
5 feet from the rear property line. The minimum required rear setback for the OT-C Zone District is 15
feet. The request is to encroach the minimum rear setback by 10 feet.
Staff Presentation:
Beals presented slides relevant to the appeal and discussed the variance request, noting that the property is
located along W Mulberry St, just E of S Meldrum St. The variance request seeks to build a shed in the rear of
the property. The property does abut an alley on the east property line. The proposed shed will have a vehicle
access drive from the rear alley. The request is to encroach into the rear setback by 10 feet and maintain a
proposed 5-foot setback to the rear property line.
Presenting aerial view of the property, Beals explained that the abutting property is a parking lot owned by
Colorado State University. The applicant has provided a letter of support from the University. Beals explained
even if there were a house on the abutting property to the south, that house would face S Meldrum St and
would be enjoying a 5-foot setback from that same property line.
Beals presented site plans describing the placement of the proposed shed and vehicle driveway. Additionally,
street views of the property were shown, with Beals noting that the original garage has been turned into
additional living space. The original driveway off of W Mulberry St is still extant, Beal does not believe that
driveway will be abandoned or removed.
Vice-Chair Lawton asked if there were any easements. Beals confirmed that no easements are present.
Lawton confirmed that vehicular access to the proposed structure would now be taken from the alley.
Commission member San Filippo asked Beals if the removal of the original driveway should be considered as
a condition of approval that the Commission might grant, or is that more of an issue for the Building Dept?
Beals responded that staff have not recommended that condition; it may be less of a Building Dept concern
and more of an Engineering Dept item. It is probably considered a non-confirming driveway given how close it
is to the alley. Regarding this variance request, there is no impact or associated staff recommendation.
Commission member Floyd asked Beals what zoning is applied to the CSU property? Beals answered that it
may be the same (OT-C), however, the city has no jurisdiction over CSU property so it may not technically be
zoned.
Applicant Presentation:
Petitioner rep Jevard Hitch, on behalf of Aswad Allen, SJY Community Investments, LLC, addressed the
Commission and offered comment. Hitch stated that the way this house is situated necessitates access from
the rear, and in order to maintain the yard as usable space, the shed needs to be placed 5 feet from the rear
property line.
Vice-Chair Lawton asked about turning the garage into habitable space and asked if this was a part of the
larger plan to build the shed/garage building. Hitch noted these were separate decisions, as the homeowners
realized a lack of storage space that necessitated the construction of a new shed
4/10/25 – LURC MINUTES – DRAFT 4
Commission member San Filippo asked if this home is currently undergoing a full renovation? Hitch responded
that the overall renovations are about 90% completed, and the shed is one of the last pieces needed for
completion.
San Filippo asked for the overall height of the shed. Hitch indicated the shed would measure 12 ft x 24 ft x 8 ft.
Beals confirm that the shed is a conforming with other standards based on size and measurements.
Public Comment:
-NONE-
Commission Discussion:
Commission member Coffman sees no problem with the variance request. When considering that the property
abuts a parking lot the effect is nominal and inconsequential. Placing the shed further from the house
maintains a usable yard area. From a public safety perspective, reducing access points from W Mulberry St
increases safety and mitigates potential traffic risks.
Commission member San Filippo mentioned another mitigating factor which is an apparent 10-15-foot grass
area between the fence on the rear of the applicant’s property line and the asphalt surface of the parking lot.
Commission member Vogel feels the proposal would increase area safety, noting that backing out of the drive
to access W Mulberry St is not as safe. Rear access to the property is much safer.
Vice-Chair Lawton is in agreement with the previous comments of the Commission. Lawton does maintain
some concern that the existing driveway could continue to be used for vehicular parking, but if staff and
Engineering have not it tagged as a concern, it is not a problem with approval of the variance request.
Commission member Coffman made a motion, seconded by member Vogel to APPROVE ZBA250006,
granting the requested variance to Land Use Code Section 2.1.6 to allow the proposed detached
accessory structure to be placed 10 feet into the required 15-foot rear setback as shown in the hearing
materials.
The Commission finds that the variance would not be detrimental to the public good; and will not
diverge from Section 2.1.6 except in a nominal and inconsequential way when considered in the
context of the neighborhood and will continue to advance the purposes of the Land Use Code
contained in Section 1.2.2 because: the south property line abuts a parking lot; the proposed structure
is one-story; and the proposed 5-foot setback maintains space for emergency access around the
structure.
This decision is based upon the agenda materials, information presented during this hearing, and
Commission discussion. The Commission hereby adopts the information, analysis, findings and
conclusions regarding this variance contained in the hearing staff report.
Yeas: Gupta, Vogel, Lawton, San Filippo, Floyd, Coffman
Nays:
Absent: Carron
4/10/25 – LURC MINUTES – DRAFT 5
c. APPEAL ZBA250007
Address: 523 E Magnolia St
Owner: Mark Cassalia / Liesel Hans
Petitioner: Keira Harkin, Old Town Desings, Inc.
Zoning District: OT-B
Code Section: 2.1.6
Project Description:
There are two requests associated with this variance application:
1) A request to exceed the maximum allowable floor area for a proposed 2,429 square foot house
with a 430 square foot attached garage. The maximum allowable floor area for a detached
house in the OT-B Zone District is 2,400 square feet. The request is to exceed the maximum
allowable floor area by 459 square feet.
2) A request to encroach the front setback by 4 feet 2 inches for a covered porch and 1 foot 11
inches for the front of the building wall. The covered front porch at the front of the house is
proposed to be 10 feet 10.25 inches from the property line, and the front wall of the house is
proposed to be 13 feet 1 inch from the property line. The minimum required front setback in the
OT-B Zone District is 15 feet.
Staff Presentation:
Beals presented slides relevant to the appeal and discussed the variance request, noting that the property is
located on Smith St near E Magnolia. This is a fairly recent subdivision of lots in the area. The lot that was
created faces E Magnolia St and abuts the alley to the west
As seen in aerial views of the property, the lot size is different for the area and is shallow. This makes meeting
the required front and rear setbacks more difficult and is the impetus for pursuing the current variance
requests.
The first variance request is a front setback encroachment; the proposal meets the rear setback requirement of
15 feet, but this results in an encroachment of the front setback. This is a single request, but encroachment
occurs in two areas: the covered front porch and a portion of the front wall. Both create a setback of less than
15 feet.
Along E Magnolia, there are a number of structures that also encroach into the front setback. Other homes that
face off of Smith St now are required to meet a 9-foot front setback rather than the previous 15-foot setback.
The second request is to increase floor area for a primary structure. The maximum allowable floor area for a
primary house in this district is 2,400 square feet. Because the garage is attached, it is required to be counted
as a portion of the primary structure. If the garage were to be detached, it would be required to be a minimum
of 5 feet away from the primary structure, resulting in an encroachment of the rear setback. If the garage were
to be detached, the result would be a need for a variance for an additional 29 square feet for the primary
structure.
Renderings of the proposed structure describe the covered porch as open on three sides, as well as the front
wall of the primary structure that encroaches into the front setback.
The property line for this lot is not at the back of the sidewalk, so there is a bit of additional distance remaining
from the property line to the back of the sidewalk.
Lawton asked Beals to return to the image of the plat, to clarify the boundaries of the new subdivision. Beals
explained that the back fence is now the new side property line. Beals notes that when a property is re-platted,
it becomes one property with portions of three original lots making up the new subdivision.
4/10/25 – LURC MINUTES – DRAFT 6
Applicant Presentation:
Applicant representative Keira Harkin, Old Town Desings, Inc., and property owner Mark Cassalia, 405 Smith
St, addressed the Commission and offered comment. Harkin stated that due to the nature of the lot being
shallow, it is difficult to fit the planned home on the lot while being wholly compliant with code standards. They
spent a lot of time considering how the home could be positioned on the lot, and felt the current design is a
reasonable request in order to allow the home that is needed for the applicant’s family while minimizing
impacts on the neighborhood.
Cassalia noted they have been working with the city for more than 2 years on this project and has additionally
worked with Historic Preservation regarding 501 E Magnolia St. Cassalia feels the home matches the context
of the neighborhood and is happy with the current design.
Public Comment:
-NONE-
Commission Discussion:
Commission member Coffman stated that regarding setbacks, this is very much in line with the area. No other
homes meet the 15-foot setback. Regarding floor area, this is almost the “textbook” example of nominal
change, as it would not need a variance if it were detached. This is of public benefit, as it adds housing density
to a desirable area. Coffman is in support of the variance.
Commission member San Filippo agrees with Coffman; San Filippo feels this is a well thought out plan.
Setbacks are in line with others in the neighborhood. Alley access to the garage prevents blocking of the alley.
San Filippo In support of the variance request.
Vice-Chair Lawton is giving consideration based in part on the property across the alley that has previously
gained LURC approval. The proposal is a good use of space and meets the city’s goals of increased density
and additional housing. The garage could be compliant just to match a rule but wouldn’t make much sense and
would look strange.
Commission member Vogel is in agreement and appreciates that neighbor support has been provided.
Commission member Coffman made a motion, seconded by member Vogel to APPROVE ZBA250007,
granting the requested variances to Land Use Code Section 2.1.6 to allow the proposed house with
attached garage to exceed the maximum allowable floor area by 459 square feet; and to allow the front
building wall to encroach into the front setback by 1 foot 11 inches and covered front porch to
encroach into the front setback by 4 feet 2 inches; all as shown in the hearing materials.
The Commission finds that the variances would not be detrimental to the public good; and the setback
variance will not diverge from Section 2.1.6 except in a nominal and inconsequential way when
considered in the context of the neighborhood and will continue to advance the purposes of the Land
Use Code contained in Section 1.2.2 because the Magnolia Street block face has varying building
setbacks that are less than 15 feet; and regarding the floor area variance, by reason of exceptional
physical condition of the property, namely the shallow and unique lot shape, the strict application of
the code would result in unusual and exceptional practical difficulties or undue hardship not caused
by the property owner regarding placement of a compliant detached structure.
This decision is based upon the agenda materials, information presented during this hearing, and
Commission discussion. The Commission hereby adopts the information, analysis, findings and
conclusions regarding these variances contained in the hearing staff report.
Yeas: Gupta, Vogel, Lawton, San Filippo, Floyd, Coffman
Nays:
Absent: Carron
4/10/25 – LURC MINUTES – DRAFT 7
6. OTHER BUSINESS
Beals offered welcome to our two new Commission members and expressed gratitude at their willingness
to assist the Community. Beals also noted that next month’s meeting will include the election of Officers.
Vice-Chair Lawton welcomed the return of Brad Yatabe as our supporting City Attorney.
Yatabe urged consideration of the Commission regarding holding elections at the beginning or end of the
hearing. Yatabe also reiterated that a vote to abstain will be counted as an affirmative vote. Regarding
minutes, under Robert’s Rules, a commission member is allowed to participate in voting for the Minutes
regardless of their previous participation. It is considered an administrative vote that relies on the accuracy
of those staff who produce the Minutes.
Yatabe also noted that site visits are fine to make to gather information ahead of hearings and urged
members to state at the beginning of discussion that a site visit has been made, report their observations
and note the time of day the visit was made. That allows Commission members and applicants to have full
awareness of observations and have a chance to confirm or refute observations made.
Commission member San Filippo noted that he is fond of making site visits and confirms Yatabe’s
suggestions that best practice would be to make a report of his site visit observations prior to applicant
presentations.
-Beals suggests we update the meeting script to prompt disclosure of site visits.
-Lawton will send revisions to the script to administrative staff for correction and additions.
-San Filippo notes he wears his volunteer badge to identify himself when performing site visits.
7. ADJOURNMENT
The Meeting was adjourned at 9:18 AM.
Agenda Item 2
Item # 2 - Page 1
STAFF REPORT May 8, 2025
STAFF
Noah Beals, Senior City Planner/Zoning
PROJECT
ZBA250009
PROJECT DESCRIPTION
Address: 519 W Mountain Ave
Owner/Petitioner: Christopher and Ellen Kelly
Zoning District: OT-B
Code Section: 2.1.6
Variance Request:
This is a request to increase the finished square footage in an existing detached house from 2,593 square feet
to 2, 826 square feet by enclosing an existing 234 square foot porch. The maximum allowable floor area in the
OT-B Zone District is 2,400 square feet.
COMMENTS:
1. Background:
The property is part of the original town Plat of 1873. The primary building was constructed in 1898. There
have been significant alterations since then with the lates occurring in 2016.
The property fronts onto W Mountain Ave. It is located midblock. However, an alley exists that runs north-
south, and the property’s east side abuts the alley.
The 2016 addition created a porch on the back of the house. This porch is enclosed on two sides and has a
roof that matches the design of the rest of the house. Additionally, there is a detached structure that is
approximately 5ft away from one of the open sides of the porch. The proximity of the accessory structure
gives the appearance the porch being enclosed on three sides.
The Land Use Code limits the size of the primary structures based on the floor area. The existing structure
is over the maximum size already by 193 sf. The prosed design enclosing the porch on two sides for
habitable space will increase the floor area by an additional 234 sf.
2. Applicant’s statement of justification: See petitioner’s letter.
3. Staff Conclusion and Findings:
Under Section 2.10.4(H), staff recommends approval and finds that:
• The variance is not detrimental to the public good.
• The proposed floor area is an existing porch that is enclosed by two walls and an abutting
accessory structure.
• The additional floor area is in the rear half of the along the alley.
• Visual impact of the increased floor area is limited.
Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way,
when considered in the context of the neighborhood, and will continue to advance the purpose of the Land
Use Code contained in Section 1.2.2
4. Recommendation:
Staff recommends approval of APPEAL ZBA250009.
Written Statement - separate document
April 3, 2025
Address: 519 West Mountain Avenue
Owners: Ellen Kelly and Chris Kelly
Variance request: Under Article 2 section 2.1.6 of the Fort Collins Land Use Code Floor
area is limited to 2,400 sf. This request is to allow for an Exception to increase the existing
finished square feet of 2,592 sf to 2,826 sf by means of building two walls and enclosing an
existing porch.
Plan: Enclose an existing porch by constructing two walls. The house will be reconfigured to
fix a non conforming bedroom and create a hall way to improve flow through the house. The
enclosed porch will be used as a dining room off the main Kitchen. The existing dining room
will be used to expand an existing bedroom and create a closet. A hallway will be created to
improve the flow through the property.
Discussion:
The property improvements are the culmination of three major development projects, 1898
original construction, 1950s 1st addition and 2017 2nd addition. Early in the 20th century a
detached garage also was built.
The master bedroom is a non conforming 138 SF bedroom that is bifurcated by a staircase
and does not have a closet. The design of the house does not allow for uninterrupted flow
through the house. The project will fix design flaws, but will not create additional rooms or
functionality.
Hardship:
Without the Exception the house is a two bedroom house with poor circulation. The 1898
design creates a unique design issue for the bedroom and flow through. If not for the
recently implemented Land Use Code Standards these issues were easily addressable
based on the size of the lot and improvements made in 2017.
Equally Well or Better Than:
This proposed solution solves a problem created by the design of the 1898 house. The only
viable alternative to this plan would be to demolish the house and build a compliant
efficient 2400 SF house. This proposal is better then demolition because the community
would lose a classic Queen Ann Victorian. We have considered both alternatives our
preference is to renovate the house.
Nominal and inconsequential:
Given the size of the lot, The city approved subdivision of the 11,000 lot and the nature of
the 500 block of Mountain avenue the request is nominal and inconsequential as follows;
- The two walls will be constructed on an existing porch constructed in 2017 addition and
sits on top of a basement. The square footage is part of the existing structure.
- The porch that will be enclosed is on the back of the house and can't be seen from
Mountain avenue. The porch is not easily visible from the neighbors and will not be any
more visible after it is enclosed.
- The property is under developed. The lot is 11,000 sf. On March 19, 2002 the city approved
the subdivision of the property into two lots. The subdivision has not been recorded. If
recorded the two lots will qualify for 4,800 SF of building area above ground. The total SF
above ground for this request is 2,826 sf.
- There is not historic impact for this space.
- The back half of the property will have less than 33% of the total square footage.
• The house will remain consistent with the neighborhood after the two walls are
constructed. 3 of the 12 properties in the 500 block of Mountain Avenue are larger than the
3436 sf living area (above grade living space and basement) of the property. The majority of
the homes in the 500 block of Mountain Avenue have been constructed, or have gone
through major renovation in the past 20 years.
- This porch was always planned to be enclosed. When it was constructed in 2017 the roof
was insulated and finished with Beetle kill wood. The space has roughed in gas, electric
and venting for heating.
Agenda Item 3
Item # 3 - Page 1
STAFF REPORT May 8, 2025
STAFF
Noah Beals, Senior City Planner/Zoning
PROJECT
ZBA250010
PROJECT DESCRIPTION
Address: 2000 Mathews St
Owner: Poudre Fire Authority
Petitioner: Marie Hashaw, DaVinci Sign Systems, Inc
Zoning District: R-L
Code Section: 5.16.2 (B)
Variance Request:
This is a request to allow for a 5-foot-tall wall sign. The maximum allowable height for a wall sign in the
Residential Sign District is 1.5 feet. The request is to therefore exceed the maximum allowable height for a wall
sign by 3.5 feet.
COMMENTS:
1. Background:
The property is a part of the 1957 South College Avenue Consolidated Annexation. The City was the
property owner at the time the existing building was originally constructed in 1976. It has seen alterations
and upgrades since then.
R-L zone is designed to be predominately residential uses, therefore non-residential uses are subject to the
residential sign district standards. These sign standards are to limit the impact of signs and ensure they are
proportionate to residential uses in the area.
The property is surrounded by public right of way and a city park, specifically Spring Park. The closest
residential building is 171ft away to the northwest. However, the view between this residential building and
the proposed sign location is blocked by mature evergreen trees.
The proposed sign is designed to be 3.5ft taller than the allowed 1.5ft maximum. This sign is planned to be
on the west side of the building above the engine bay doors. View of the proposed sign is limited and is
best seen from the Spring Park Drive that leads from College Avenue straight to front of the building.
2. Applicant’s statement of justification: See petitioner’s letter.
3. Staff Conclusion and Findings:
Under Section 2.10.4(H), staff recommends approval and finds that:
• The variance is not detrimental to the public good
• The sign is on the west side of the building that faces College Ave.
• There are mature evergreen trees limiting the view of the sign to the north.
• The property does not abut a residential property.
Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential way,
when considered in the context of the neighborhood, and will continue to advance the purpose of the Land
Use Code contained in Section 1.2.2
4. Recommendation:
Staff recommends approval of APPEAL ZBA250010
$SSOLFDWLRQ5HTXHVW
IRU9DULDQFHIURPWKH/DQG8VH&RGH
7KH/DQG8VH5HYLHZ&RPPLVVLRQ KDVEHHQJUDQWHGWKHDXWKRULW\WR DSSURYHYDULDQFHV IURPWKHUHTXLUHPHQWV
RI$UWLFOHVDQGRIWKH/DQG8VH&RGH7KH/DQG8VH5HYLHZ&RPPLVVLRQVKDOOQRWDXWKRUL]HDQ\XVHLQ D]RQLQJ
GLVWULFWRWKHUWKDQWKRVH XVHVZKLFKDUHVSHFLILFDOO\ SHUPLWWHGLQ WKH]RQLQJGLVWULFW7KH&RPPLVVLRQ PD\JUDQW
YDULDQFHVZKHUHLW ILQGVWKDWWKHPRGLILFDWLRQRIWKHVWDQGDUGZRXOGQRWEHGHWULPHQWDOWRWKHSXEOLF JRRG
$GGLWLRQDOO\WKHYDULDQFHUHTXHVWPXVWPHHWDWOHDVWRQHRIWKHIROORZLQJMXVWLILFDWLRQUHDVRQV
E\UHDVRQRIH[FHSWLRQDOSK\VLFDOFRQGLWLRQVRU RWKHUH[WUDRUGLQDU\DQGH[FHSWLRQDOVLWXDWLRQVXQLTXHWR
WKH SURSHUW\LQFOXGLQJEXWQRWOLPLWHGWR SK\VLFDOFRQGLWLRQVVXFK DV H[FHSWLRQDO QDUURZQHVV
VKDOORZQHVV RU WRSRJUDSK\WKHVWULFWDSSOLFDWLRQRIWKHFRGHUHTXLUHPHQWVZRXOG UHVXOW LQ XQXVXDODQG
H[FHSWLRQDO SUDFWLFDO GLIILFXOWLHV RUXQGXHKDUGVKLS XSRQWKHRFFXSDQWDSSOLFDQWRIWKHSURSHUW\SURYLGHG
WKDWVXFK GLIILFXOWLHV RU KDUGVKLS DUHQRWFDXVHGE\DQDFW RU RPLVVLRQRIWKHRFFXSDQWDSSOLFDQWLHQRW
VHOILPSRVHG
WKHSURSRVDO ZLOOSURPRWH WKHJHQHUDO SXUSRVH RIWKHVWDQGDUGIRU ZKLFKWKHYDULDQFH LVUHTXHVWHG
HTXDOO\ ZHOORU EHWWHUWKDQ ZRXOG DSURSRVDO ZKLFKFRPSOLHV ZLWKWKHVWDQGDUGIRU ZKLFKWKHYDULDQFH LV
UHTXHVWHG
WKHSURSRVDO ZLOOQRWGLYHUJHIURPWKH/DQG8VH&RGHVWDQGDUGVH[FHSWLQ DQRPLQDO LQFRQVHTXHQWLDO
ZD\ZKHQFRQVLGHUHGLQ WKHFRQWH[WRIWKHQHLJKERUKRRG
7KLVDSSOLFDWLRQLVRQO\IRUDYDULDQFHWRWKH/DQG8VH&RGH%XLOGLQJ&RGHUHTXLUHPHQWVZLOOEHGHWHUPLQHG
DQGUHYLHZHGE\WKH%XLOGLQJ'HSDUWPHQWVHSDUDWHO\ :KHQDEXLOGLQJRUVLJQSHUPLWLVUHTXLUHGIRUDQ\ZRUN
IRUZKLFKDYDULDQFHKDVEHHQJUDQWHGWKHSHUPLWPXVWEHREWDLQHGZLWKLQPRQWKVRIWKHGDWHWKDWWKH
YDULDQFHZDVJUDQWHG
+RZHYHUIRUJRRGFDXVHVKRZQE\WKHDSSOLFDQWWKH/DQG8VH5HYLHZ&RPPLVVLRQ PD\FRQVLGHUDRQHWLPHPRQWK
H[WHQVLRQLIUHDVRQDEOHDQGQHFHVVDU\XQGHUWKHIDFWVDQGFLUFXPVWDQFHVRIWKHFDVH$Q H[WHQVLRQUHTXHVWPXVWEH
VXEPLWWHGEHIRUHPRQWKVIURPWKHGDWHWKDWWKHYDULDQFHZDVJUDQWHGKDVODSVHG
3HWLWLRQHURU3HWLWLRQHU¶V5HSUHVHQWDWLYH PXVWEHSUHVHQWDWWKHPHHWLQJ
/RFDWLRQ/D3RUWH$YH&LW\+DOO&RXQFLO&KDPEHUV
LQVWUXFWLRQVZLOOEHHPDLOHGWR WKHDSSOLFDQWWKH)ULGD\RU0RQGD\SULRUWRWKHKHDULQJ
'DWH6HFRQG7KXUVGD\RIWKHPRQWK7LPH DP
Variance Address Petitioner’s Name,
if not the Owner
City Petitioner’s Relationship
to the Owner is
Zip Code Petitioner’s Address
Owner’s Name Petitioner’s Phone #
Code Section(s)Petitioner’s Email
Zoning District Additional
Representative’s Name
Justification(s)Representative’s Address
Justification(s)Representative’s Phone #
Justification(s)Representative’s Email
Reasoning
Date ___________________________________ Signature __________________________________________
tZ/ddE^ddDEdyW>/E/E'd,Z^KE&KZd,sZ/EZYh^dZYh/Zs/
^WZdKhDEd͘
______________
%XLOGLQ RGHH XLUHPHQWVZLOOEHGHWHUPLQHG
QG HYLHZHGE WKH%XLOGLQ H DUWPHQWVHSDUDWHO
2000 Mathews St DaVinci Sign Systems, Inc.
Contractor
80525 4496 Bents Dr, Windsor, CO
Poudre Fire Authority 970-203-9292
3.8.7.2 (B)marie@davincisign.com
RL
04/07/25
3. Nominal and inconsequential
dditional Justification
dditional Justification
April 7, 2025
City of Fort Collins
281 N College Ave
Fort Collins, CO 80524
To Whom It May Concern:
Re: Sign Variance Request for Poudre Fire Authority, 2000 Mathews St
DaVinci Sign Systems and Poudre Fire Authority are requesting a variance for a wall sign that
exceeds allowed wall height in this district.
The site is zoned RL and is in the Residential Sign District. Section 3.8.7.2 (B) of the Land Use
Code states that a wall sign in the Residential Sign District shall not exceed 1.5 feet in height.
Based on the size of the elevation and the distance the sign is away from vehicular traffic, we
feel a sign of this size (5 feet) is necessary and fits the overall architecture and scale of the
elevation. Were the sign not within the Residential Sign District, it could have a height of 7 feet.
The proposed sign will not diverge from the Land Use Code standards except in a nominal,
inconsequential way considering the orientation of the building to any residential lot. The
nearest residential unit is 200 feet away and the sign does not face it directly. Only the letters
illuminate and they are small at 2¾”.
Thank you for your consideration. Please let me know if you have any questions or comments.
You may reach me at 970-203-9292. Thank you.
Sincerely,
Marie Hashaw
328'5(),5(67$7,21
0$7+(:667
)257&2//,16&2
'DWH
'DWH
[
[
%B7JODJ"QQSPWBM ā ā ā
Ă Ă Ă
ă ă ă
ą ą ą
Ć Ć Ć
,$16(1(6$&-9$/$6(.
12&2675(9,6,21
+
+
00,1&+(6
3/$&(0(175(1'(5,1*6&$/(µ ·µ
5(027(:,5('127($&&(6672%$&.6,'(
2)6,*1,65(48,5(')255(027(:,5(',167$//$7,21
$µ&257(167((/%$&.(53$1(/&87726+$3(
%µ67((/',$021'3/$7(:$7(5-(7&87,1)285
6(3$5$7(6+$3(6$1'3,102817('72&257(1%$&.(5
:,7+µ352-(&7,21
&µ'((3$/80,180&216758&7('5(9(56(3$1
&+$11(//2*23$,17('%/$&.&23<72%(5287('
$1'386+7+58µ&/($5$&5</,&:,7+6(&21'
685)$&(',))86(5),/0$1'),567685)$&(
75$16/8&(17:+,7(),/002817(':,7+µ
352-(&7,21)520%$&.',$021'3/$7(6+$3(
,17(51$//<,//80,1$7(':,7+./('·6
'
(
µ'((3$/80,180)$%5,&$7('5(9(56(3$1180(5$/
3$,17('%/$&.02817(':,7+µ352-(&7,21
)520%$&.',$021'3/$7(6+$3(,17(51$//<
,//80,1$7(':,7+:+,7(./('·6
µ$/80,180&,5&/(%$&.(53$1(/3$,17('
$33529('&2/2502817(':,7+µ352-(&7,21
)520%$&.&257(13$1(/
,620(75,&9,(:
,//80,1$7('1,*+77,0(5(1'(5,1*
6,*163(&,),&$7,216
/2*26,*1 0$18)$&785($1',167$// µ ·µ"
:+,7(/('·6
%
·
µ
·
µ
·µ
·
µ
3
·
µ
3
&
(
$
'
328'5(),5(67$7,21
0$7+(:667
)257&2//,16&2
'DWH
'DWH
[
[
%B7JODJ"QQSPWBM ā ā ā
Ă Ă Ă
ă ă ă
ą ą ą
Ć Ć Ć
,$16(1(6$&-9$/$6(.
12&2675(9,6,21
·
µ
·µ
·
µ
·µ
&257(1%$&.3$1(/ 02817,1*%5$&.(7 ',$021'3/$7( 02817,1*
53&/2*2)250$1'180(5$/
%$&./$<(5 0,'/$<(5
723/$<(5
·
µ
·
µ
/2*25(7851,1
&,5&/(6+$3(
µ$&5</,&:
386+7+58·µ
µ67((/$1*/(02817,1*%5$&.(7
$77$&+('72&08:,7+&21&5(7(
$1&+256
µ;µ67((/$1*/(:(/'('72%$&.
6,'(2)&257(167((/3$1(/
µ7+,&.',$021'3/$7(&8772
6+$3(µ352-(&7,2102817
*$&257(167((/3$1(/&8772
6+$3(
µ7+58%2/76:,7+1876:$6+(56
µ'((3$/80,180&216758&7('
&$%,1(7:5287('$1'386+7+85
*5$3+,&6%$&.2)6+$3(72+$9(
&/($5µ32/<&$5%21$7()25+$/2
,//80,1$7,21,//80,1$7(':,7+.
:+,7(/('·6
µ'((35(9(56(3$1&+$11(//(77(5
,//80,1$7(':,7+.:+,7(/('·6
µ$/80,1803$1(/&8772&,5&/(
6+$3(µ352-(&7,2102817
0$7(5,$/6
·
µ
·µ
·
µ
Agenda Item 4
Item # 4 - Page 1
STAFF REPORT May 8, 2025
STAFF
Noah Beals, Senior City Planner/Zoning
PROJECT
ZBA250011
PROJECT DESCRIPTION
Address: 1300 E Laurel St
Owner/Petitioner: Corey Neuroth
Zoning District: CCR
Code Section: 3.1.7 and 3.1.8
Variance Request:
There are two requests associated with this variance:
1. A request for a proposed 2,400 square foot detached accessory building (garage) to replace four existing
detached accessory structures. The maximum allowable square footage for a detached accessory building for
this lot is 800 square feet.
2. A request for a proposed addition (attached garage w/habitable space above) to encroach 9 feet into the
required front setback at its closest point to the property line. The minimum required front setback for this
property in the CCR zone district is 15 feet.
COMMENTS:
1. Background:
The property is part of the 1987 Hoffman Mill annexation. Prior to annexation, the primary building and
some accessory buildings were built under the county jurisdiction in 1947.
At the time of annexation, it was zoned for commercial uses. Still today it is in the Community Commercial
Poudre Rive District which consist of mostly nonresidential uses.
The proposed design is seeking to remove four accessory structures to build a new detached accessory
structure. In the CCR zone the size of an accessory structure is limited by the size of the parcel. The
current parcel size allows a maximum of 800 sf. accessory structure. This zone district does not have a limit
on the number of accessory structures that could exists. Additionally, within this zone primary structures are
allowed to be a similar size as the proposed structure.
The parcel shape is long east to west and skinny north to south. The front lot line is not 90 degrees to the
side or rear property lines. The unique shape and size of the parcel create limitations on meeting the 15ft
setback from the front property line. Additionally, this the last house at the end of E Laurel Street that ends
abutting City Streets department facilities.
2. Applicant’s statement of justification: See petitioner’s letter.
3. Staff Conclusion and Findings:
Under Section 2.10.4(H), staff recommends approval and finds that:
• The variances are not detrimental to the public good.
• The CCR zone district allows for large size structures on small parcels
• The City Streets department facilitates are to the east of the property.
• The parcel shape is unique in size and shape compared to other parcels in the area.
Agenda Item 4
Item # 4 - Page 2
Therefore, the variance request will not diverge from the standard but in a nominal, inconsequential
way, when considered in the context of the neighborhood, and will continue to advance the purpose of
the Land Use Code contained in Section 1.2.2.
Also, the variance request may be granted due to a hardship of the lot not caused by the applicant and
a strict application of the code results in a practical difficulty upon the applicant.
4. Recommendation:
Staff recommends approval of APPEAL ZBA250011
Application Request
IRU9DULDQFHIURPWKH/DQG8VH&RGH
The /DQG8VH5HYLHZ&RPPLVVLRQ has been granted the authority to approve variances IURPWKHUHTXLUHPHQWV
RI$UWLFOHVDQGRIWKH/DQG8VH&RGH7KH/DQG8VH5HYLHZ&RPPLVVLRQVKDOOQRWDXWKRUL]HDQ\XVH LQ D]RQLQJ
GLVWULFWRWKHUWKDQWKRVH XVHVZKLFKDUHVSHFLILFDOO\ SHUPLWWHGLQ WKH ]RQLQJGLVWULFW7KH&RPPLVVLRQ PD\JUDQW
YDULDQFHVZKHUHLW ILQGVWKDWWKHPRGLILFDWLRQRIWKHVWDQGDUGwould not be detrimental to the public good
$GGLWLRQDOO\WKHYDULDQFHUHTXHVWPXVWPHHWDWOHDVWRQHRIWKHIROORZLQJMXVWLILFDWLRQUHDVRQV
E\UHDVRQRIH[FHSWLRQDOSK\VLFDOFRQGLWLRQVRU RWKHUH[WUDRUGLQDU\DQGH[FHSWLRQDOVLWXDWLRQVXQLTXHWR
WKH SURSHUW\LQFOXGLQJEXWQRWOLPLWHGWR SK\VLFDOFRQGLWLRQVVXFK DV H[FHSWLRQDO QDUURZQHVV
VKDOORZQHVV RU WRSRJUDSK\WKHVWULFWDSSOLFDWLRQRIWKHFRGHUHTXLUHPHQWVZRXOG UHVXOW LQ XQXVXDODQG
H[FHSWLRQDO SUDFWLFDO GLIILFXOWLHV RUXQGXHKDUGVKLS XSRQWKHRFFXSDQWDSSOLFDQWRIWKHSURSHUW\SURYLGHG
WKDWVXFK GLIILFXOWLHV RU hardship DUHQRWFDXVHGE\DQDFW RU RPLVVLRQRIWKHRFFXSDQWDSSOLFDQWLHQRW
VHOILPSRVHG
WKHSURSRVDO ZLOOSURPRWH WKHJHQHUDO SXUSRVH RIWKHVWDQGDUGIRU ZKLFKWKHYDULDQFH LVUHTXHVWHG
equally well or better than ZRXOG DSURSRVDO ZKLFKFRPSOLHV ZLWKWKHVWDQGDUGIRU ZKLFKWKHYDULDQFH LV
UHTXHVWHG
WKHSURSRVDO ZLOOQRWGLYHUJHIURPWKH/DQG8VH&RGHVWDQGDUGVH[FHSWLQ Dnominal, inconsequential
way ZKHQFRQVLGHUHGLQ WKHFRQWH[WRIWKHQHLJKERUKRRG
This application is only for a variance to the Land Use Code. Building Code requirements will be determined
and reviewed by the Building Department separately. When a building or sign permit is required for any work
for which a variance has been granted, the permit must be obtained within 6 months of the date that the
variance was granted.
+RZHYHUIRUJRRGFDXVHVKRZQE\WKHDSSOLFDQWWKH/DQG8VH5HYLHZ&RPPLVVLRQ PD\FRQVLGHUDRQHWLPHPRQWK
H[WHQVLRQLIUHDVRQDEOHDQGQHFHVVDU\XQGHUWKHIDFWVDQGFLUFXPVWDQFHVRIWKHFDVH$Q H[WHQVLRQUHTXHVWPXVWEH
VXEPLWWHGEHIRUHPRQWKVIURPWKHGDWHWKDWWKHYDULDQFHZDVJUDQWHGKDVODSVHG
Petitioner or Petitioner’s Representative must be present at the meeting
Location9,578$/21/<YLD=RRP
LQVWUXFWLRQVZLOOEHHPDLOHGWR WKHDSSOLFDQWWKH)ULGD\RU0RQGD\SULRUWRWKHKHDULQJ
Date6HFRQG7KXUVGD\RIWKHPRQWK7LPH DP
Variance Address Petitioner’s Name,
if not the Owner
City Petitioner’s Relationship
to the Owner is
Zip Code Petitioner’s Address
Owner’s Name Petitioner’s Phone #
Code Section(s)Petitioner’s Email
Zoning District Additional
Representative’s Name
Justification(s)Representative’s Address
Justification(s)Representative’s Phone #
Justification(s)Representative’s Email
Reasoning
Date ___________________________________ Signature __________________________________________
tZ/ddE^ddDEdyW>/E/E'd,Z^KE&KZd,sZ/EZYh^dZYh/Zs/
^WZdKhDEd͘
Choose One from List
dditional Justification
dditional Justification
Buildin od e uirements will be determined
nd eviewed b the Buildin e artmen separatel
1300 E Laurel St.
80524
Corey Neuroth
4/8/25
1901 Unity Court FTC. 80528
303-249-1608
Coreyneuroth@gmail.com
CCR
Please see attached Statement
City of Fort Collins Zoning Variance Request Statement
Date: 4/8/25
Applicant Name: Corey Neuroth
Property Address: 1300 E Laurel St., Fort Collins, CO 80524
Phone Number: 303-249-1608
Email: coreyneuroth@gmail.com
Variance Request Summary
We respectfully request a variance from the Fort Collins Land Use Code to allow for the following
modifications to our property:
1. Front Setback Reduction - 3.1.7
o Proposed scope of work and reason for variance: Build a new, attached, 2 car garage on
the west side of property. With additional habitable space above. The habitable space
would expand current habitable space and would not be a separate dwelling. Without
the variance, there would not be adequate room for the proposed garage and additional
habitable space..
o Current Requirement: 15’ from front of property
o Requested Reduction: Front setback reduced to 6 feet
o Justification: The existing structure on the property is already located within
approximately 8 feet of the front property line. We are requesting a minimal additional
reduction to 6 feet in order to maintain alignment with the current building footprint,
Allow for a standard sized garage, and allow functional site design improvements. This
small adjustment would not negatively impact visibility, pedestrian access, or the
aesthetics of the streetscape.
2. Accessory Unit Size Increase - 3.1.8
o Proposed Scope of work and reason for Variance: Remove existing accessory structures
that have been poorly maintained and are visually unappealing. Combine accessory
spaces into one larger detached garage unit. Reducing overall footprint and improving
quality and aesthetic appeal.
o Current Maximum Allowed: 800ft2 per unit, Multiple units allowed
o Requested Size: Up to 2,400 square feet – Detached garage
o Justification: Rather than constructing multiple smaller accessory buildings, we propose
a single, well-designed structure totaling up to 2,400 square feet. This approach reduces
visual clutter, minimizes site disruption, and maintains a cohesive architectural style. A
single building is also more energy-efficient and environmentally sustainable than
multiple smaller units, and will be designed to complement the primary residence and
overall neighborhood character.
Justification for Variance Request
• Unusual Conditions or Constraints:
The lot presents unique conditions due to the location of the existing residence and the shape of
the lot which would hinder the accessibility of multiple accessory units on the back portion of
the lot.
The current site constraints also restrict the potential for upgrades and make it difficult to fully
comply with the existing front setbacks and accessory unit size requirements.
• Impact on Neighborhood:
The requested variance will not alter the essential character of the neighborhood. The proposed
changes are in harmony with existing structures on neighboring properties and will maintain
public safety, access, and privacy.
• Public Benefit:
Constructing a single, larger accessory unit will reduce construction impacts and infrastructure
demands compared to multiple smaller structures. It will also decrease overall footprint and
construction timelines.
Attachments
• Site Plan showing proposed setback and accessory unit location
• Survey of current property
• Copy of easement agreement for property
Thank you for taking the time to review our variance request. We greatly appreciate your consideration
and the work you do to support thoughtful and sustainable development in Fort Collins. We believe our
proposed changes will enhance the functionality and character of our property while remaining aligned
with the values of the surrounding community.
Please don’t hesitate to reach out if any additional information or clarification is needed. We look
forward to working with you throughout this process.
Signature: ___________________________
Printed Name: Corey Neuroth
Date: 4/8/2025
V I C I N I T Y M A P
This is not a Legal Survey, nor is it intended to
be or replace one.
These measurements are approximate and are
for illustrative purposes only.
This work product represents only generalized
location of features, objects or boundaries and
should not be relied upon as being legally
authoritative for the precise location of any
feature, objects or boundary.
Disclaimer
S I T E P L A N
1300 E Laurel St
Fort Collins, CO 80524
Parcel ID: 87182-00-042
Lot area: 0.28 Acres
Paper Size: 11"x17"
scale 1"=20'
Graphic scale:
0 12 25 50
201'
74'
60
'
116'
172'
26'7'
56.2'
28
.
2
'
56.2'
28
.
2
'
14'
4'
24'
20
'
37'9
"
47'
19
'
29'5"
32
'
44'
24
.
5
"
6'
40'
6'
5'
6'
47'
12
'
Property line
Property line
Property line
Property line
wall line
driv
e
w
a
y
propo
s
e
d
drivew
a
y
proposed
stairs
proposed
garage
proposed
building
cover
porch
EXISTING
HOUSE
No.1300
S Fett
e
r
l
y
A
v
e
cent
e
r
l
i
n
e
con
t
>
4
9
5
4
f
t
con
t
>
4
9
5
2
f
t
con
t
>
4
9
5
0
f
t
con
t
>
4
9
4
8
f
t
cont>49
4
6
f
t
31'
8'
7'
6'
6'
15'
N 88°40'00" E 205.51'
N 88°31'45" E 74.96'
S
0
1
°
2
9
'
0
1
"
E
6
0
.
8
4
'
S 85°59'59" W 117.98'
N 69°13'
0
0
"
W
1
7
5
.
7
0
'
N 88°40'00" E 1041.80'
N
0
1
°
2
9
'
0
1
"
W
1
5
4
.
8
0
'
93
.
9
6
'
N88°40'E 280.50' (R)
S0
1
°
2
0
'
E
6
0
.
8
4
'
(
R
)
S86°07'W 117.86' (R)
N69°13'
W
1
7
5
.
7
0
'
(
R
)
(R)
BASIS OF BEARINGS
NORTH LINE OF THE SW1/4 OF THE NW1/4 OF SECTION 18
OWNER: CITY OF FORT COLLINS
NW1/4, NW1/4 OF SECTION 18
OWNER: CITY OF FORT COLLINS
LOT 1, HOFFMAN MILL SUBDIVISION
RECEPTION NO. 20190004037
OWNER: MOSE PICARD
UN-PLATTED
OWNER: ELMER SCHNEIDER
UN-PLATTED
28
.
2
'
56.2'
28
.
2
'
56.2'
22.0
'
20.0
'
22.0
'20.0
'
18.0
'22.0
'
18.0
'
22.0
'
10.4
'12.4
'
10.4
'
12.4
'
5.
8
'
6.
1
'
7.7
'
1.6
'
2.
0
'
6.
2
'
15
.
2
'
COVERED PORCH
RESIDENCE
ON FOUNDATION
GARAGE
ON SLAB
GARAGE
ON SLAB
WOOD SHED
8'x8'
PERGOLA
CONCRETE
DRIVEWAY
ADJACENT
RESIDENCE
GRAVE
L
A
C
C
E
S
S
R
O
A
D
EAST L
A
U
R
E
L
S
T
R
E
E
T
RIGHT
O
F
W
A
Y
D
O
C
U
M
E
N
T
S
WERE N
O
T
P
R
O
V
I
D
E
D
NORTHWEST 1/16TH CORNER OF SECTION 18
FOUND 2-1/2" ALUMINUM CAP ON 3/4" REBAR
MARKED "PLS 5028 - 2002"
N 88°40'00" E 1247.31'
POINT OF COMMENCEMENT/BEGINNING
PER THE DESCRIPTION
NOTE THAT THE SEPTIC TANK
AND LEACH FIELD COULD NOT BE
VISUALLY LOCATED AND MAY BE
OFFSITE OF THE PARCEL
ACCESS DOOR
7.
0
'
15
.
5
'
2.8
'
2.0
'
4.
2
'
5.1
'
5.
2
'
18
.
4
'
NOTICE: According to Colorado law you must commence any legal
action based upon any defect in this survey within three years after you
first discover such defect. In no event, may any action based upon any
defect in this survey be commenced more than ten years from the date
of the certification shown hereon.
RE
V
I
S
I
O
N
:
RE
V
I
S
I
O
N
:
RE
V
I
S
I
O
N
:
RE
V
I
S
I
O
N
:
DR
A
W
N
B
Y
:
FI
E
L
D
D
A
T
E
:
PR
O
J
E
C
T
N
O
.
:
CL
I
E
N
T
:
DW
G
.
D
A
T
E
:
S
OF
HE E T
㻟㻜
㻢
㻌
㻱
㻚
㻌
㻱
㻸
㻵
㼆
㻭
㻮
㻱
㼀
㻴
㻌
㻿
㼀
㻾
㻱
㻱
㼀
㻲㻻
㻾
㼀
㻌
㻯
㻻
㻸
㻸
㻵
㻺
㻿
㻌
㻯
㻻
㻸
㻻
㻾
㻭
㻰
㻻
㻔㻥
㻣
㻜
㻕
㻌
㻞
㻟
㻞
㻙
㻥
㻠
㻤
㻞
㼏㼠
㼔
㼑
㼣
㻬
㼠
㼞
㼕
㻙
㼜
㼑
㼍
㼗
㼟
㻚
㼏
㼛
㼙
TR
I
-
P
E
A
K
S
,
L
L
C
㻯㻸
㼀
W2
3
-
1
4
5
12
-
1
2
-
2
0
2
3
12
-
1
5
-
2
0
2
3
BO
B
B
I
E
M
A
S
T
E
R
S
11
CITY OF FORT COLLINS, COUNTY OF LARIMER, STATE OF COLORADO
SITUATE IN THE NORTHWEST 1/4 OF SECTION 18, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH P.M.,
IMPROVEMENT SURVEY PLAT
㻯㻱㻾㼀㻵㻲㻵㻯㻭㼀㻵㻻㻺㻦
㻵㻌㻯㻴㻾㻵㻿㼀㻻㻼㻴㻱㻾㻌㻸㻚㻌㼀㻴㻱㼃㻘㻌㻭㻌㻰㼁㻸㼅㻌㻸㻵㻯㻱㻺㻿㻱㻰㻌㻼㻾㻻㻲㻱㻿㻿㻵㻻㻺㻭㻸㻌㻸㻭㻺㻰㻌㻿㼁㻾㼂㻱㼅㻻㻾㻌㻵㻺㻌㼀㻴㻱
㻿㼀㻭㼀㻱㻌㻻㻲㻌㻯㻻㻸㻻㻾㻭㻰㻻㻘㻌㻰㻻㻌㻴㻱㻾㻱㻮㼅㻌㻯㻱㻾㼀㻵㻲㼅㻌㼀㻴㻭㼀㻌㼀㻴㻱㻌㻿㼁㻾㼂㻱㼅㻌㻾㻱㻼㻾㻱㻿㻱㻺㼀㻱㻰㻌㻮㼅㻌㼀㻴㻵㻿
㻼㻸㻭㼀㻌㻵㻿㻌㼀㻴㻱㻌㻾㻱㻿㼁㻸㼀㻿㻌㻻㻲㻌㻭㻌㻿㼁㻾㼂㻱㼅㻌㻹㻭㻰㻱㻌㻮㼅㻌㻹㻱㻌㻻㻾㻌㼁㻺㻰㻱㻾㻌㻮㼅㻌㻰㻵㻾㻱㻯㼀㻌㻿㼁㻼㻱㻾㼂㻵㻿㻵㻻㻺㻚
㻿㼁㻾㼂㻱㼅㻻㻾㻦㻌㻯㻴㻾㻵㻿㼀㻻㻼㻴㻱㻾㻌㻸㻚㻌㼀㻴㻱㼃㻘㻌㻼㻱㻙㻼㻸㻿㻌㻔㻼㻸㻿㻏㻌㻟㻤㻢㻥㻞㻕
LEGEND
PUBLIC LAND SURVEY MONUMENT AS DESCRIBED
FOUND 1/2" REBAR WITH 1.0" PLASTIC CAP MARKED "PLS 38692"
SET 1/2" REBAR WITH 1" PLASTIC CAP MARKED "PLS 38209"
AIR CONDITIONER
ELECTRIC METER
TELECOMMUNICATIONS PEDESTAL
WATER METER
FIRE HYDRANT
GAS METER
PARCEL LINE
BOUNDARY LINE
FENCE LINE
SECTION LINE
㻸㻱㻳㻭㻸㻌㻰㻱㻿㻯㻾㻵㻼㼀㻵㻻㻺㻦
CONSIDERING THE WEST LINE OF THE SW1/4 OF THE NW1/4 OF
SECTION 18, TOWNSHIP 7 NORTH, RANGE 68 WEST OF THE 6TH P.M.,
AS BEARING DUE NORTH AND WITH ALL BEARINGS HEREIN RELATIVE
THERETO: COMMENCING AT A POINT WHICH BEARS N88°40'E 1041.80
FEET FROM THE NORTHWEST CORNER OF THE SW1/4 OF THE NW1/4
OF SAID SECTION, THENCE N88°40'E 280.50 FEET, THENCE S01°20'E
60.84 FEET, THENCE S86°07'W 117.86 FEET, THENCE N69°13'W 175.70
FEET TO THE POINT OF BEGINNING.
NOTES
- THE LEGAL DESCRIPTION FOR THIS SURVEY IS BASED ON THE DEED RECORDED AT
RECEPTION NO. 20050089747 OF THE LARIMER COUNTY RECORDS.
- THE CLIENT DID NOT REQUEST A TITLE COMMITMENT TO BE ORDERED FOR THIS
SURVEY OR REQUEST ADDITIONAL EASEMENTS/RIGHT OF WAYS TO BE SHOWN;
THEREFOR ADDITIONAL RIGHT-OF-WAYS AND EASEMENTS OF RECORD WERE NOT
RESEARCHED FOR THIS SURVEY. ANY INFORMATION REGARDING DOCUMENTS THAT
MIGHT AFFECT THE QUALITY OF TITLE TO SUBJECT PROPERTY WERE NOT
DETERMINED.
- SUBJECT PROPERTY ADDRESS IS 1300 EAST LAUREL STREET, FORT COLLINS,
COLORADO 80524.
- BEARINGS ARE BASED ON THE NORTH LINE OF THE SOUTHWEST 1/4 OF THE
NORTHWEST 1/4 OF SECTION 18 TO HAVE THE ASSUMED BEARING OF N88°40'E
BETWEEN THE NORTH 1/16TH CORNER OF SECTIONS 18 AND 13 AND THE NORTHWEST
1/16TH CORNER OF SECTION 18, SAID MONUMENTS ARE DESCRIBED AS SHOWN ON
THIS SURVEY.
- UNITS ARE SHOWN IN U.S. SURVEY FOOT
- THE TOTAL AREA CONTAINS 12,858 SQUARE FEET (0.295 ACRES) MORE OR LESS.